• Title/Summary/Keyword: lateral taper.

Search Result 32, Processing Time 0.021 seconds

Behavior of Lateral Loaded Piles with Pile shape and Length (말뚝형태 및 길이변화를 고려한 수평재하말뚝의 거동특성)

  • Hwang, Sung-Wook;Kim, Min-Kee;Kyung, Du-Hyun;Lee, Jun-Hwan
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.03a
    • /
    • pp.1125-1131
    • /
    • 2008
  • In this study, Calibration Chamber Tests for cast-in-place piles in sand were performed for measuring behavior properties of piles. These tests were examined effects of various parameters of soil conditions including the relative density($D_R$), the coefficient of earth pressure, and investigated differences between cylindrical pile and taper-shaped pile with the same volumes. The important effect factors of foundation behavior were investigated by considering embedded depth of piles and shapes of piles, and inspected details of lateral behavior of piles. These results were verified reliabilities of each methods for comparing the results estimated with tests and the results by proposed estimating solutions in the past.

  • PDF

Comparison of warm gutta-percha condensation techniques in ribbon shaped canal : weight of filled gutta-percha after canal obturation

  • Kim, Hyun-Hee;Cho, Kyung-Mo;Kim, Jin-Woo
    • Proceedings of the KACD Conference
    • /
    • 2001.11a
    • /
    • pp.573.1-573
    • /
    • 2001
  • The purpose of this study to evaluate several wann gutta-percha filling techniques using weight changes of resin blocks before and after canal filling in ribbon shaped canal. Simulated ribbon shaped root canals in 30 transparent resin blocks were instrumented to #40 using 06 taper Profile. 15 resin blocks were obturated with gutta-percha using cold lateral condensation. Warm lateral condensation using the Endotec II was then accomplished on the same 15 blocks. Another 15 resin blocks were obturated using the System B.(omitted)

  • PDF

The Eigenvalues and Their Relationships for the Rectangular Frame (4각형 골조의 고유치와 고유치 간의 관계)

  • Lee, Soo-Gon;Kim, Soon-Cheol;Song, Chang-Young;Song, Sang-Yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.9 no.3
    • /
    • pp.139-150
    • /
    • 2005
  • Finite element method is applied to the determinations of the two eigenvalues(the elastic critical load and the natural frequence of lateral vibrations) of single story-3 equal bay rectangular frame. The analysis parameters are taper parameter ${\alpha}$ for column, and beam span to column height ratio, ${\beta}$ and second moment area ratio of beam to column, ${\Upsilon}$. Support condition at the column base and sway condition at the column top are also considered in the stability analysis of frame. The changes in the coefficient of eigenvalue are represented by algebraic function of analysis parameter. The coefficients estimated by the proposed algebraic function show good agreement with those determined by finite element method, which suggest the design aid role of the proposed function. By increasing the column axial forces step by step, the corresponding frequencies are also determined, which makes one examine or confirm the relationship suggested by other studies.

A COMPARISON OF THE APICAL SEAL PRODUCED BY EASY FILLING SYSTEM AND QUICK OBTURATION SYSTEM (Easy Filling 및 Quick Obturation System을 이용한 열연화 충전법의 치근단 밀폐도 평가)

  • Shin, Jung-In;Kum, Kee-Yeon;Lee, Sung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.2
    • /
    • pp.202-211
    • /
    • 2000
  • The aim of this study was to compare the apical sealing ability of a new thermoplasticized gutta-percha filling technique, the Easy Filling and the Quick Obturation system with lateral condensation technique and Thermafil system to evaluate their clinical acceptabilities. Fifty-two extracted single-rooted teeth were instrumented to #35 using the .04 taper ProFile system. Four groups of 12 teeth were obturated by lateral condensation technique. Thermafil system and two new thermoplasticized gutta-percha techniques, the Easy Filling system and Quick Obturation system (Meta Dental co. Ltd. Korea), respectively. Four teeth served as controls. After the teeth were immersed in 2% methylene blue dye for 48 hours, they were resected horizontally at 1mm to 5mm level from the anatomical apex using a low-speed microtome. Each section was examined under a stereomicroscope at ${\times40}$ magnification and photographed. After each image was scanned, the leakage area was measured at each level using Brain 3 (Nosdia Tech., Korea) software. Leakage ratio was calculated for each group and was analyzed statistically to come up with the following results: 1. At 1mm level, the Quick Obturation system had the largest amount of apical leakage and it was statistically significant when compared with the lateral condensation group and the Thermafil group (p<0.05). 2. At 2mm and 3mm level, there were no significant difference of apical leakage among all four groups (p>0.05), and from 4mm level, no apical dye penetration was observed in all the groups. In conclusion, the apical seal produced by Easy Filling system and the Quick Obturation system was comparable to lateral condensation technique and Thermafil system except for the 1mm level. More improvement of the apical seal can be expected as the operator becomes skillful with the new techniques.

  • PDF

Tapered Etching of Field Oxide with Various Angle using TEOS (다양한 기울기를 갖는 TEOS 필드 산화막의 경사식각)

  • 김상기;박일용;구진근;김종대
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.10
    • /
    • pp.844-850
    • /
    • 2002
  • Linearly graded profiles on the field area oxide are frequently used in power integrated circuits to reduce the surface electric field when power devices are operated in forward or reverse blocking modes. It is shown here that tapered windows can be made using the difference of etch rates between the bottom and the top layer of TEOS film. Annealed TEOS films are etched at a lower rate than the TEOS film without annealing Process. The fast etching layer results in window walls having slopes in the range of 25$^{\circ}$∼ 80$^{\circ}$ with respect to the wafer surface. Taper etching technique by annealing the TEOS film applies to high voltage LDMOS, which is compatible with CMOS process, due to the minimum changes in both of design rules and thermal budget.

A comparison of thermoplasticized injectable gutta-percha technique in ribbon-shaped canals: Adaptation to canal walls

  • Hwang, Hyun-Sook;Cho, Kyuong-Mo;Kim, Jin-Woo
    • Proceedings of the KACD Conference
    • /
    • 2001.11a
    • /
    • pp.587.1-587
    • /
    • 2001
  • The aim of this study is to compare the adaptability of thermoplasticized injectable gutta-percha technique to the canal walls in ribbon-shaped canals. Thirty resin models simulated ribbon-shaped canals were instrumented to #40 using. 06 taper Profile systems. Three groups of 10 resin models were obturated by the lateral condensation technique(LC) and the two thermoplasticized injectable gutta-percha technique; Ultrafil Endoset+Obtura II(EO) and Ultrafil Firmset(UF), respectively.(omitted)

  • PDF

Targeting a Safe Entry Point for C2 Pedicle Screw Fixation in Patients with Atlantoaxial Instability

  • Chun, Hyoung-Joon;Bak, Koang-Hum
    • Journal of Korean Neurosurgical Society
    • /
    • v.49 no.6
    • /
    • pp.351-354
    • /
    • 2011
  • Objective : This investigation was conducted to evaluate a new, safe entry point for the C2 pedicle screw, determined using the anatomical landmarks of the C2 lateral mass, the lamina, and the isthmus of the pars interarticularis. Methods : Fifteen patients underwent bilateral C1 lateral mass-C2 pedicle screw fixation, combined with posterior wiring. The C2 pedicle screw was inserted at the entry point determined using the following method : 4 mm lateral to and 4 mm inferior to the transitional point (from the superior end line of the lamina to the isthmus of the pars interarticularis). After a small hole was made with a high-speed drill, the taper was inserted with a 30 degree convergence in the cephalad direction. Other surgical procedures were performed according to Harm's description. Preoperatively, careful evaluation was performed with a cervical X-ray for C1-C2 alignment, magnetic resonance imaging for spinal cord and ligamentous structures, and a contrast-enhanced 3-dimensional computed tomogram (3-D CT) for bony anatomy and the course of the vertebral artery. A 3-D CT was checked postoperatively to evaluate screw placement Results : Bone fusion was achieved in all 15 patients (100%) without screw violation into the spinal canal, vertebral artery injury, or hardware failure. Occipital neuralgia developed in one patient, but this subsided after a C2 ganglion block. Conclusion : C2 transpedicular screw fixation can be easily and safely performed using the entry point of the present study. However, careful preoperative radiographic evaluation, regardless of methods, is mandatory.

INFLUENCE OF NICKEL-TITANIUM SPREADER ON THE SEALING ABILITY IN LATERAL CONDENSATION TECHNIQUE (측방가압충전시 Nickel-Titanium spreader의 사용유무가 근관충전효과에 마치는 영향)

  • Min, Kyung-San;Hong, Chan-Ui;Cho, Yong-Bum
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.3
    • /
    • pp.381-389
    • /
    • 2000
  • Lateral condensation with gutta-percha and sealer has been shown to provide an excellent apical seal; however, the lateral condensation technique has demonstrated less favorable apical leakage results in curved canals when compared with straight canals. Placement of endodontic spreaders to within 1 to 2mm of the root canal working length has been advocated for optimum gutta-percha obturation. Due to their stiffness, stainless-steel(SS) spreaders will often fail to achieve this position in curved canals. Newly marketed nickel-titanium(NT) spreaders may offer an advantage in this regard due to the increased flexibility of these instruments. The purpose of this study was to evaluate the effect of NT finger spreader on the sealing ability in lateral condensation technique, compared with conventional SS finger spreader. Twenty four standardized resin models simulating curved canals(30 degree) were randomly placed into 2 groups and instrumented to a #30 master apical file size with Ni-Ti Profile .04 taper series using step down technique. Each groups was obturated with standardized gutta-percha cone by standard lateral condensation technique using SS finger spreader, NT finger spreader. And then, each model was sectioned horizontally with microtome at 1, 2, 3, 4, 5mm levels from the apex. At each of 5 levels, ratio of the area of gutta-percha was obtained by calculating the area of gutta-percha to the total area of the canal. The data collected were then analyzed statistically using a t test for independent samples. The results as follows ; 1. The total mean ratio of area of gutta-percha was 89.20${\pm}$7.00(%) for SS spreader group. 92.20${\pm}$5.17(%) for NT spreader group. There was statistically significant difference between each group(p<0.05). 2. At 3mm level, the mean ratio of area of gutta-percha was 88.32${\pm}$5.41(%) for SS spreader group, 95.25${\pm}$2.60(%) for NT spreader group. There was statistically significant difference between each group(p<0.05). At 1,2,4mm levels, NT spreader group showed greater mean ratio of area of gutta-percha than SS spreader group, too. But there was no statistically significant difference. 3. At 5mm level, the mean ratio of area of gutta-percha was 91.83${\pm}$3.42(%) for SS spreader group, 87.91${\pm}$3.68(%) for NT spreader group. There was statistically significant difference between each group(p<0.05). This study concluded that the NT spreader demonstrated somewhat favorable apical sealing effect than SS spreader in prepared curved canals. The clinical use of NT spreaders may enhance our ability to create better apical seals in curved canals, but further studies in this area will help clarify some of the remaining areas with which practitioners are concerned, such as compaction forces exerted by NT spreaders.

  • PDF

Obturation efficiency of non-standardized gutta-percha cone in curved root canals prepared with 0.06 taper nickel-titanium instruments (0.06-경사도의 니켈-티타늄 기구로 형성된 레진 만곡근관에서 비표준화 GUTTA-PERCHA CONE의 근관충전 효율)

  • Lee, Eun-Ah;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.2
    • /
    • pp.79-85
    • /
    • 2005
  • The purpose of this study was to evaluate the obturation efficiency of a non-standardized gutta-percha cone in curved root canals prepared with 0.06 taper nickel-titanium instruments. Sixty simulated curved root canals in clear resin blocks were prepared with crown-down technique using 0.06 taper rotary $ProTaper^{TM}$and ProFile (Dentsply-Maillefer) until apical canal was size 30. Root canals were randomly divided into 4 groups of 15 blocks and obturated with cold-laterally compacted gutta-percha technique by using either a non-standardized size medium gutta-percha cone or an ISO-standardized size 30 one as a master cone. Gutta-percha area ratio were calculated at apical levels of 1, 3 and 5 mm using AutoCAD 2000 after cross-sectioning, and the data were analyzed with one-way and two-way ANOVAs and Duncan's multiple range test. Non-standardized size medium cone groups showed significantly higher gutta-percha area ratio than standardized cone groups at all apical levels (p < 0.01). Non-standardized cone groups used significantly less accessory cones than standardized cone groups (p < 0.01).

A COMPARISON OF THERMOPLASTICIZED INJECIABLE GUTTA-PERCHA TECHNIQUES IN RIBBON-SHAPED CANALS : ADAPTATION TO CANAL WALLS (리본 형태의 근관에서 열연화주입법의 근관벽에 대한 적합도에 관한 연구)

  • Hwang, Hyun-Sook;Cho, Kyung-Mo;Kim, Jin-Woo
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.4
    • /
    • pp.411-420
    • /
    • 2002
  • The aim of this study is to compare the adaptability of thermoplasticized injectable gutta-percha technique to the canal walls in ribbon-shaped canals. Thirty resin models simulated ribbon-shape canals were instrumented to #40 using .06 taper Profile systems. Three groups of each 10 resin models were obturated by the lateral condensation technique(LC) and the two thermoplasticized injectable gutta-percha technique; Ultrafil Endoset+Obtura II(EO) and Ultrafil Firmset(UF), respectively. After resin model were kept at room temperature for 4 days, they were resected horizontally with micro-tome at 1, 2, 3, 4 and 5mm levels from apex. At each levels. image of resected surface were taken using CCD camera under a stereomicroscope at $\times$40 magnification and stored. Ratio of the area of gutta-percha was obtained by calculating area of gutta-percha cone to the total area of canal using digitized image-ana-Iyzing program. The data were collected then analyzed statistically using One-way ANOVA. The results were as follows. 1 At 1mm levels, there was no statistically significant difference in the mean ratio of gutta-percha among the groups. 2. At 2mm level, EO showed the highest mean ratio of gutta-percha (p<0.05) and there was no significant difference between LC and UF. 3. At 3, 4, 5mm levels, EO and UF had significantly greater mean ratio of gutta-percha than LC(p<0.05) and there was no significant difference between EO and UF. In conclusion, the thermoplasticized injectable gutta-percha techniques demonstrated relatively favorable adaptability to canal walls than lateral condensation technique in ribbon-shaped canals except for 1mm level.