• 제목/요약/키워드: lateral motion

검색결과 796건 처리시간 0.032초

생체전위를 이용한 중증 운동장애자들을 위한 컴퓨터 접근제어장치 설계 (Design of Computer Access Devices for Severly Motor-disability Using Bio-potentials)

  • 정성재;김명동;박찬원;김일환
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제55권11호
    • /
    • pp.502-510
    • /
    • 2006
  • In this paper, we describe implementation of a computer access device for the severly motor-disability. Many people with severe motor disabilities need an augmentative communication technology. Those who are totally paralyzed, or 'locked-in' cannot use conventional augmentative technologies, all of which require some measure of muscle control. The forehead is often the last site to suffer degradation in cases of severe disability and degenerative disease. For example, In ALS(Amyotrophic Lateral Sclerosis) and MD(Muscular dystrophy) the ocular motorneurons and ocular muscles are usually spared permitting at least gross eye movements, but not precise eye pointing. We use brain and body forehead bio-potentials in a novel way to generate multiple signals for computer control inputs. A bio-amplifier within this device separates the forehead signal into three frequency channels. The lowest channel is responsive to bio-potentials resulting from an eye motion, and second channel is the band pass derived between 0.5 and 45Hz, falling within the accepted Electroencephalographic(EEG) range. A digital processing station subdivides this region into eleven components frequency bands using FFT algorithm. The third channel is defined as an Electromyographic(EMG) signal. It responds to contractions of facial muscles and is well suited to discrete on/off switch closures, keyboard commands. These signals are transmitted to a PC that analyzes in a time series and a frequency region and discriminates user's intentions. That software graphically displays user's bio-potential signals in the real time, therefore user can see their own bio-potentials and control their physiological signals little by little after some training sessions. As a result, we confirmed the performance and availability of the developed system with experimental user's bio-potentials.

최적 타이어 힘 분배를 이용한 6WD/6WS 차량의 등판 주행 성능 향상 (Improvement of Hill Climbing Ability for 6WD/6WS Vehicle using Optimum Tire Force Distribution Method)

  • 김상호;김창준;한창수
    • 한국산학기술학회논문지
    • /
    • 제12권4호
    • /
    • pp.1523-1531
    • /
    • 2011
  • 본 다축 차량은 험지와 야전에서 높은 이동성 때문에 비포장도로를 주행해야 하는 군용차량으로 사용된다. 특히 군용차량은 군 요구 사항에 의거 기본적으로 60% 경사로에서 안정적인 등판 성능을 지녀야 한다. 따라서 본 논문은 최적 타이어 힘 분배 방법을 통한 6WD/6WS차량의 등판능력 향상을 다루었다. 경사로 등판 시 사용할 최적 타이어 힘 분배 방법을 위하여 운전자로부터, 목표로 하는 종 방향 힘과 횡 방향 힘, 요 모멘트를 계산하였고, 마찰 원이론과 목적함수에 따른 최적화 된 토크가 각 륜에 분배되었다. 알고리즘 성능을 확인하기 위해서, 트럭심 소프트웨어를 이용하여 시뮬레이션 하였고, 비교를 위하여 2대의 차량을 제안하였다. 한 대의 차량은 최적타이어 힘 분배 방법이 적용되었고, 나머지 한 대는 궤도 차량과 같은 균등 힘 분배 방법이 적용되었다. 경사로에서 등판능력은 최적 타이어 힘 분배 방법에 의해서 향상 되어졌다.

컴퓨터 디자인 기반 모노스키 버킷 사용에 따른 장애인 알파인 스키 선수의 운동학적 특성 변화 연구: 사례 연구 (Disabled Alpine Ski Athlete's Kinematic Characteristic Changes by Computer Aided Design Based Mono Ski Bucket: A Case Study)

  • 구도훈;은선덕;현보람;권효순
    • 한국운동역학회지
    • /
    • 제24권4호
    • /
    • pp.425-433
    • /
    • 2014
  • The purpose of the study was to investigate the effect of CAD (Computer Aided Design) based alpine mono-ski bucket design on disabled ski athletes' kinematic characteristics. Two national team ski athletes with LW11 disabilities (Locomotion Winter Classification) category for sit ski participated in both pre and post experiment. Both of the subjects performed 3 trials of carved turn on a ski slope under two conditions. Where, subject "A" performed pre experiment with personal bucket and post experiment with the newly developed CAD based bucket whereas, Subject "B" as control subject performed both pre and post experiment with his personal bucket. For the experiment, 24 Infrared cameras were positioned on the ski slope which covered the path of the ski turn. Also, motion capture suit with reflective markers were worn by both subjects. In the result, decrement in medial/lateral displacement of COM, anterior/posterior displacement of COM, flexion/extension angle of trunk as well as velocity losing rate of COM was observed in subject "A" when using the newly developed CAD based bucket. In contrast, no larger effect on performance was observed when using personal buckets. In conclusion, the findings obtained from the study indicated effectiveness of newly developed CAD based bucket by reducing excessive movement of hip and trunk which is an important factor to perform an effective turn.

고관절 외전시 중둔근의 근력 및 활동전위 변화에 관한 연구 (A Myometric and Electromyographic Analysis of Hip Abductor Musculature in Healthy Right-Handed Persons)

  • 권혁철
    • The Journal of Korean Physical Therapy
    • /
    • 제2권1호
    • /
    • pp.35-46
    • /
    • 1990
  • The right hip adbuctor musculature has been reported to demonstrate 'stretch weakness' attributable to chronic elongation imposed by standing posture common to right-handed healthy persons. Kendall and associates have described the concept of 'stretch weakness'. The purpose of this study was to assess isometric hip abduction torque and surface electro-myographic activity (using MYOMED 432) in a sample of 40 healthy right-handed persons (20 male, 20 female), all of whom agreed to participate in the study, and compare side difference in the hip abductor musculature. In order to assure the statistical significance of the results, the paired t-test was applied at the .05 level of significance. The results were as follows : 1. The difference in apparent leg length of right and left legs was significant at the .05 leve1. 2. There was a significant difference between right and left pelvic height (standing position) at the .005 level measurements, and scapula height at the .05 level. 3. Power measurements and action potentials of right hip adbuctor were greater than the left hip adbuctor regardless of the range of joint motion (inner range, outer range). 4. The difference in muscle power and action potentials according to inner or outer range of both hip abductor were significant at the .05 level. 5. In supine during active left hip abduction, the appearance of action potentials in the right hip abductors is indicative of contra-lateral effect (p<.005). These results suggest : In healthy right-handed persons. the apparent leg length on the right is longer than on the left, and pelvic height is elevated on the right side. Muscle torque and muscle action potentials of the right hip adbuctor art higher than those of the hip abductor in the lengthened position. Therefore, the results in this study are contrary to Kendall's. This type of study should be carried out in many physical therapy departments.

  • PDF

선박의 크기를 고려한 두 선박의 간섭력에 관한 시뮬레이션 (Simulation of Interaction Forces between Two Ships Considering Ship's Dimension)

  • 이상도
    • 한국시뮬레이션학회논문지
    • /
    • 제26권3호
    • /
    • pp.47-54
    • /
    • 2017
  • 본 연구에서는 선박조종시뮬레이터를 이용하여 선박의 크기에 따른 두 선박의 간섭력의 운동특성을 분석하였다. 파나막스급 컨테이너선이 자선보다 크기가 작은 계류선을 근접통항하는 경우에 계류선에서 간섭력의 피크점과 운동패턴의 변화가 뚜렷하게 나타났다. 이땐 선박의 정횡 상태 전후에서 전후력과 회두모멘트가 반대방향으로 바뀌므로 계류선의 움직임에 각별한 주의가 요구된다. 반대로 파나막스급 컨테이너선이 자선보다 큰 계류선을 통과하는 경우에는 근접상황이 발생하는 초기에 통과선에서 간섭력의 피크점이 나타났고, 통과선에는 정횡 이후 약 1L(통과선의 전장)의 구간동안 지속적으로 흡인력이 발생했다. 또한, 통과선과 계류선의 선체간의 수평거리가 2B(통과선의 폭)이하로 줄어들면, 통과선의 초기에 발생하는 간섭력이 급격히 증대된다.

Wear evaluation of CAD-CAM dental ceramic materials by chewing simulation

  • Turker, Izim;Kursoglu, Pinar
    • The Journal of Advanced Prosthodontics
    • /
    • 제13권5호
    • /
    • pp.281-291
    • /
    • 2021
  • PURPOSE. To evaluate the wear of computer-aided design/computer-aided manufacturing (CAD-CAM) dental ceramic materials opposed by enamel as a function of increased chewing forces. MATERIALS AND METHODS. The enamel cusps of healthy human third molar teeth (n = 40) opposed by materials from CAD-CAM dental ceramic groups (n = 10), including Vita Enamic® (ENA), a polymer-infiltrated ceramic network (PICN); GC Cerasmart® (CERA), a resin nanoceramic; Celtra® Duo (DUO), a zirconia-reinforced lithium silicate (ZLS) ceramic; and IPS e.max ZirCAD (ZIR), a polycrystalline zirconia, were exposed to chewing simulation (1,200,000 cycles; 120 N load; 1 Hz frequency; 0.7 mm lateral and 2 mm vertical motion). The wear of both enamel cusps and materials was quantified using a 3D laser scanner, and the wear mechanisms were evaluated by scanning electron microscopy (SEM). The results were analysed using Welch ANOVA and Kruskal Wallis test (α = .05). RESULTS. ZIR showed lower volume loss (0.02 ± 0.01 mm3) than ENA, CERA and DUO (P = .001, P = .018 and P = .005, respectively). The wear of cusp/DUO [0.59 mm3 (0.50-1.63 mm3)] was higher than cusp/CERA [0.17 mm3 (0.04-0.41 mm3)] (P = .007). ZIR showed completely different wear mechanism in SEM. CONCLUSION. Composite structured materials such as PICN and ZLS ceramic exhibit more abrasive effect on opposing enamel due to their loss against wear, compared to uniform structured zirconia. The resin nano-ceramic causes the lowest enamel wear thanks to its flexible nano-ceramic microstructure. While zirconia appears to be an enamel-friendly material in wear volume loss, it can cause microstructural defects of enamel.

Development of Optimized Headland Turning Mechanism on an Agricultural Robot for Korean Garlic Farms

  • Ha, JongWoo;Lee, ChangJoo;Pal, Abhishesh;Park, GunWoo;Kim, HakJin
    • Journal of Biosystems Engineering
    • /
    • 제43권4호
    • /
    • pp.273-284
    • /
    • 2018
  • Purpose: Conventional headland turning typically requires repeated forward and backward movements to move the farming equipment to the next row. This research focuses on developing an upland agricultural robot with an optimized headland turning mechanism that enables a $180^{\circ}$ turning positioning to the next row in one steering motion designed for a two-wheel steering, four-wheel drive agricultural robot named the HADA-bot. The proposed steering mechanism allows for faster turnings at each headland compared to those of the conventional steering system. Methods: The HADA-bot was designed with 1.7-m wide wheel tracks to travel along the furrows of a garlic bed, and a look-ahead path following algorithm was applied using a real-time kinematic global positioning system signal. Pivot turning tests focused primarily on accuracy regarding the turning radius for the next path matching, saving headland turning time, area, and effort. Results: Several test cases were performed by evaluating right and left turns on two different surfaces: concrete and soil, at three speeds: 1, 2, and 3 km/h. From the left and right side pivot turning results, the percentage of lateral deviation is within the acceptable range of 10% even on the soil surface. This U-turn scheme reduces 67% and 54% of the headland turning time, and 36% and 32% of the required headland area compared to a 50 hp tractor (ISEKI, TA5240, Ehime, Japan) and a riding-type cultivator (CFM-1200, Asia Technology, Deagu, Rep. Korea), respectively. Conclusion: The pivot turning trajectory on both soil and concrete surfaces achieved similar results within the typical operating speed range. Overall, these results prove that the pivot turning mechanism is suitable for improving conventional headland turning by reducing both turning radius and turning time.

Short-term changes in muscle activity and jaw movement patterns after orthognathic surgery in skeletal Class III patients with facial asymmetry

  • Kim, Kyung-A;Park, Hong-Sik;Lee, Soo-Yeon;Kim, Su-Jung;Baek, Seung-Hak;Ahn, Hyo-Won
    • 대한치과교정학회지
    • /
    • 제49권4호
    • /
    • pp.254-264
    • /
    • 2019
  • Objective: To evaluate the short-term changes in masticatory muscle activity and mandibular movement patterns after orthognathic surgery in skeletal Class III patients with facial asymmetry. Methods: Twenty-seven skeletal Class III adult patients were divided into two groups based on the degree of facial asymmetry: the experimental group (n = 17 [11 male and 6 female]; menton deviation ${\geq}4mm$) and control group (n = 10 [4 male and 6 female]; menton deviation < 1.6 mm). Cephalography, electromyography (EMG) for the anterior temporalis (TA) and masseter muscles (MM), and mandibular movement (range of motion [ROM] and average chewing pattern [ACP]) were evaluated before (T0) and 7 to 8 months (T1) after the surgery. Results: There were no significant postoperative changes in the EMG potentials of the TA and MM in both groups, except in the anterior cotton roll biting test, in which the masticatory muscle activity had changed into an MM-dominant pattern postoperatively in both groups. In the experimental group, the amount of maximum opening, protrusion, and lateral excursion to the non-deviated side were significantly decreased. The turning point tended to be shorter and significantly moved medially during chewing in the non-deviated side in the experimental group. Conclusions: In skeletal Class III patients with facial asymmetry, the EMG activity characteristics recovered to presurgical levels within 7 to 8 months after the surgery. Correction of the asymmetry caused limitation in jaw movement in terms of both ROM and ACP on the non-deviated side.

Comminuted Radial Head Fracture in All-arthroscopic Repair of Elbow Fracture-dislocation: Is Partial Excision of the Radial Head an Acceptable Treatment Option?

  • Yang, Hee Seok;Kim, Jeong Woo;Lee, Sung Hyun;Yoo, Byung Min
    • Clinics in Shoulder and Elbow
    • /
    • 제21권4호
    • /
    • pp.234-239
    • /
    • 2018
  • Background: In elbow fracture-dislocation, partial excision of the comminuted radial head fracture that is not amenable to fixation remains controversial considering the accompanying symptoms. This study was undertaken to evaluate the results of radial head partial excision when the comminuted radial head fracture involved <50% of the articular surface in all-arthroscopic repair of elbow fracture-dislocation. Methods: Patients were divided into two groups based on the condition of the radial head fracture. In Group A, the patients had a radial head comminuted fracture involving <50% of the articular surface, and underwent arthroscopic partial excision. Group B was the non-excision group comprising patients with stable and non-displacement fractures. Follow-up consultations were conducted at 6 weeks and at 3, 6, 12, and 24 months after surgery. Results: In all, 19 patients (Group A: 11; Group B: 8) met the inclusion criteria and were enrolled in the study. At the final follow-up, all 19 patients showed complete resolution of elbow instability. No significant differences were observed in the range of motion, visual analogue scale score, and Mayo elbow performance score between groups. Radiological findings did not show any complications of the radiocapitellar joint. However, nonunion of the coracoid fracture was observed in 3 patients (Group A: 1; Group B: 2), without any accompanying instability and clinical symptoms. Conclusions: Considering that the final outcome is coronoid fracture fixation and lateral collateral ligament complex repair for restoring elbow stability, arthroscopic partial excision for radial head comminuted fractures involving <50% of articular surface is an effective and acceptable treatment for elbow fracture-dislocation.

Inferomedially impacted zygomatic fracture reduction by reverse vector using an intraoral approach with Kirschner wire

  • Jang, Jin Woo;Cho, Jaeyoung;Burm, Jin Sik
    • Archives of Plastic Surgery
    • /
    • 제48권1호
    • /
    • pp.69-74
    • /
    • 2021
  • Background In inferomedially rotated zygomatic fractures sticking in the maxillary sinus, it is often difficult to achieve complete reduction only by conventional intraoral reduction. We present a new intraoral reduction technique using a Kirschner wire and its clinical outcome. Methods Among 39 inferomedially impacted zygomatic fractures incompletely reduced by a simple intraoral reduction trial with a bone elevator, a Kirschner wire (1.5 mm) was vertically inserted from the zygomatic body to the lateral orbital rim in 17 inferior-dominant rotation fractures and horizontally inserted to the zygomatic arch in nine medial-dominant and 13 bidirectional rotation fractures. A Kirschner wire was held with a wire holder and lifted in the superolateral or anterolateral direction for reduction. Following reduction of the zygomaticomaxillary fracture, internal fixation was performed. Results Fractures were completely reduced using only an intraoral approach with Kirschner wire reduction in 33 cases and through an additional lower lid or transconjunctival incision in six cases. There were no surgical complications except in one patient with undercorrection. Postoperative 6-month computed tomography scans showed complete bone union and excellent bone alignment. Four patients experienced difficulty with upper lip elevation; however, these problems spontaneously resolved after manual tissue lump massage and intralesional steroid (Triamcinolone) injection. Conclusions We completely reduced infraorbital rim fractures, zygomaticomaxillary buttresses, and zygomaticofrontal suture fractures in 84% of patients through an intraoral approach alone. Intraoral Kirschner wire reduction may be a useful option by which to obtain effective and powerful reduction motion of an inferomedially rotated zygomatic body.