• Title/Summary/Keyword: lateral flow assay

Search Result 25, Processing Time 0.024 seconds

A Method for Quantitative Measurement of Lateral Flow Immunoassay Using Color Camera (컬러 카메라를 이용한 측면유동 면역 어세이 정량분석 방법)

  • Park, Jongwon
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.1
    • /
    • pp.1-7
    • /
    • 2014
  • Among semi-quantitative or fully quantitative lateral flow assay readers, an image sensor-based instrument has been widely used because of its simple setup, cheap sensor price, and compact equipment size. For all previous approaches, monochrome CCD or CMOS cameras were used for lateral flow assay imaging in which the overall intensities of all colors were taken into consideration to estimate the analyte content, although the analyte related color information is only limited to a narrow wavelength range. In the present work, we introduced a color CCD camera as a sensor and a color decomposition method to improve the sensitivity of the quantitative biosensor system which utilizes the lateral flow assay successfully. The proposed setup and image processing method were applied to achieve the quantification of imitatively dispensed particles on the surface of a porous membrane first, and the measurement result was then compared with that using a monochrome CCD. The compensation method was proposed in different illumination conditions. Eventually, the color decomposition method was introduced to the commercially available lateral flow immunochromatographic assay for the diagnosis of myocardial infarction. The measurement sensitivity utilizing the color image sensor is significantly improved since the slopes of the linear curve fit are enhanced from 0.0026 to 0.0040 and from 0.0802 to 0.1141 for myoglobin and creatine kinase (CK)-MB detection, respectively.

Development of a Test Strip Reader for a Lateral Flow Membrane-based Immunochromatographic Assay

  • Park, Je-Kyun;Kim, Suhyeon
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.9 no.2
    • /
    • pp.127-131
    • /
    • 2004
  • A low-cost, simple strip reader system using a linear movement mechanism of CD-ROM deck has been developed to characterize a lateral flow membrane-based immunochromatographic assay. The test strip reader was assembled by a CD-ROM deck and home-made optical head especially designed for immunoassays. The optical head for detecting reflected light from the test strip surface consists of green light-emitting diode, large area silicon photodiode, and anodized aluminum mounting block providing a slit structure for cutting light from the LED. The stepping motor of the deck was operated in the full step mode, whose distance of each reading point is about 0.15mm. The performance of the strip reader was tested by analysis of HBV(hepatitis B virus) antigen test kit. This strip reader can be useful for inexpensive, disposable, and membrane-based assays that provide visual evidence of the presence of an analyte in a liquid sample.

Rapid and Visual Detection of Barley Yellow Dwarf Virus by Reverse Transcription Recombinase Polymerase Amplification with Lateral Flow Strips

  • Kim, Na-Kyeong;Lee, Hyo-Jeong;Kim, Sang-Min;Jeong, Rae-Dong
    • The Plant Pathology Journal
    • /
    • v.38 no.2
    • /
    • pp.159-166
    • /
    • 2022
  • Barley yellow dwarf virus (BYDV) has been a major viral pathogen causing significant losses of cereal crops including oats worldwide. It spreads naturally through aphids, and a rapid, specific, and reliable diagnostic method is imperative for disease monitoring and management. Here, we established a rapid and reliable method for isothermal reverse transcription recombinase polymerase amplification (RT-RPA) combined with a lateral flow strips (LFS) assay for the detection of BYDV-infected oat samples based on the conserved sequences of the BYDV coat protein gene. Specific primers and a probe for RT-RPA reacted and optimally incubated at 42℃ for 10 min, and the end-labeled amplification products were visualized on LFS within 10 min. The RT-RPA-LFS assay showed no cross-reactivity with other major cereal viruses, including barley mild mosaic virus, barley yellow mosaic virus, and rice black streaked dwarf virus, indicating high specificity of the assay. The sensitivity of the RT-RPA-LFS assay was similar to that of reverse transcription polymerase chain reaction, and it was successfully validated to detect BYDV in oat samples from six different regions and in individual aphids. These results confirm the outstanding potential of the RT-RPA-LFS assay for rapid detection of BYDV.

Development of Human Papillomavirus DNA Array by Using Lateral Flow Membrane Assay (Lateral Flow Membrane를 이용한 인유두종 바이러스 DNA Array의 개발)

  • Kim, Ki-Whang;Lee, Hyung-Ku;Cho, Hong-Bum
    • Korean Journal of Microbiology
    • /
    • v.44 no.4
    • /
    • pp.346-351
    • /
    • 2008
  • This study develops DNA array which can detect specific sequence of human papilomavirus (HPV) by using lateral flow membrane assay which is usually used for point of care test including pregnant diagnosis. Principle of HPV DNA array is as follow; fixing DNA probe which is peculiar to HPV type 6, 11, 16, 18, 31, 45 on a surface of lateral flow membrane and inducing hybridization response between probe and HPV PCR products which is obtained by using biotin-labeled MY09/l1 primers. And then, we can see the result of DNA hybridization that streptavidin labelled colloidal gold is responded with hybrid biotin. Lateral flow membrane array developed in this study confirms major HPV type economically and conveniently compared with existing HPV DNA chip method.

Development of a Lateral Flow Strip-Based Recombinase Polymerase Amplification Assay for the Detection of Haemonchus contortus in Goat Feces

  • Wu, Yao-Dong;Wang, Qi-Qi;Wang, Meng;Elsheikha, Hany M.;Yang, Xin;Hu, Min;Zhu, Xing-Quan;Xu, Min-Jun
    • Parasites, Hosts and Diseases
    • /
    • v.59 no.2
    • /
    • pp.167-171
    • /
    • 2021
  • Haemonchosis remains a significant problem in small ruminants. In this study, the assay of recombinase polymerase amplification (RPA) combined with the lateral flow strip (LFS-RPA) was established for the rapid detection of Haemonchus contortus in goat feces. The assay used primers and a probe targeting a specific sequence in the ITS-2 gene. We compared the performance of the LFS-RPA assay to a PCR assay. The LFS-RPA had a detection limit of 10 fg DNA, which was 10 times less compared to the lowest detection limit obtained by PCR. Out of 24 goat fecal samples, LFS-RPA assay detected H. contortus DNA with 95.8% sensitivity, compared to PCR, 79.1% sensitivity. LFS-RPA assay did not detect DNA from other related helminth species and demonstrated an adequate tolerance to inhibitors present in the goat feces. Taken together, our results suggest that LFS-RPA assay had a high diagnostic accuracy for the rapid detection of H. contortus and merits further evaluation.

Application of Rapid and Reliable Detection of Cymbidium Mosaic Virus by Reverse Transcription Recombinase Polymerase Amplification Combined with Lateral Flow Immunoassay

  • Do-Hyun, Kim;Rae-Dong, Jeong;Sena, Choi;Ho-Jong, Ju;Ju-Yeon, Yoon
    • The Plant Pathology Journal
    • /
    • v.38 no.6
    • /
    • pp.665-672
    • /
    • 2022
  • Cymbidium mosaic virus (CymMV) is one of economically important viruses that cause significant losses of orchids in the world. In the present study, a reverse transcription recombinase polymerase amplification (RT-RPA) assay combined with a lateral flow immunostrip (LFI) assay was developed for the detection of CymMV in orchid plants. A pair of primers containing fluorescent probes at each terminus that amplifies highly specifically a part of the coat protein gene of CymMV was determined for RT-RPA assay. The RT-RPA assay involved incubation at an isothermal temperature (39℃) and could be performed rapidly within 30 min. In addition, no cross-reactivity was observed to occur with odontoglossum ringspot virus and cymbidium chlorotic mosaic virus. The RT-RPA with LFI assay (RT-RPA-LFI) for CymMV showed 100 times more sensitivity than conventional reverse transcription polymerase chain reaction (RT-PCR). Furthermore, the RT-PCR-LFI assay demonstrated the simplicity and the rapidity of CymMV detection since the assay did not require any equipment, by comparing results with those of conventional RT-PCR. On-site application of the RT-RPA-LFI assay was validated for the detection of CymMV in field-collected orchids, indicating a simple, rapid, sensitive, and reliable method for detecting CymMV in orchids.

A Novel Nucleic Lateral Flow Assay for Screening phaR-Containing Bacillus spp.

  • Wint, Nay Yee;Han, Khine Kyi;Yamprayoonswat, Wariya;Ruangsuj, Pattarawan;Mangmool, Supachoke;Promptmas, Chamras;Yasawong, Montri
    • Journal of Microbiology and Biotechnology
    • /
    • v.31 no.1
    • /
    • pp.123-129
    • /
    • 2021
  • Polyhydroxyalkanoate (PHA) synthase is a key enzyme for PHA production in microorganisms. The class IV PHA synthase is composed of two subunits: PhaC and PhaR. The PhaR subunit, which encodes the phaR gene, is only present in class IV PHA synthases. Therefore, the phaR gene is used as a biomarker for bacteria that contain a class IV PHA synthase, such as some Bacillus spp. The phaR gene was developed to screen phaR-containing Bacillus spp. The phaR screening method involved two steps: phaR gene amplification by PCR and phaR amplicon detection using a DNA lateral flow assay. The screening method has a high specificity for phaR-containing Bacillus spp. The lowest amount of genomic DNA of B. thuringiensis ATCC 10792 that the phaR screening method could detect was 10 pg. This novel screening method improves the specificity and sensitivity of phaR gene screening and reduces the time and cost of the screening process, which could enhance the opportunity to discover good candidate PHA producers. Nevertheless, the screening method can certainly be used as a tool to screen phaR-containing Bacillus spp. from environmental samples.

Norovirus Targeted Bioreceptor Screening Method based on Lateral Flow Immunoassay (LFIA) (노로바이러스 검출을 위한 측면유동면역분석법 기반의 바이오리셉터 선별기법 개발)

  • Huisoo, Jang;Hyeonji, Cho;Tae-Joon, Jeon;Sun Min, Kim
    • Journal of the Korean Society of Visualization
    • /
    • v.20 no.3
    • /
    • pp.136-145
    • /
    • 2022
  • Later flow immunoassay (LFIA) is a protein analytical method based on immunoreaction. On the LFIA based protein analytical method, bioreceptor molecule plays a key role, and so a system that evaluates and manages the binding affinity of bioreceptor is needed to secure detection reliability. In this study, Lateral Flow Immunoassay based rapid Bioreceptor Screening Method (rBSM) is presented that provide a simple and quick evaluating method for the binding affinity to the target protein of the antibody as model bioreceptor. To verify this evaluation method, Virus-like particles (VLP) and anti-VLP antibodies are selected as a model norovirus, which is target protein, and the candidate bioreceptors respectively. Among the 5 different candidate antibodies, appropriate antibody could be sorted out within 30 minutes through rBSM. In addition, selected antibodies were applied to two representative LFIA based techniques, sandwich assay and competitive assay. Among these methods, sandwich assay showed more effective VLP detection method. Through applying selected antibodies and techniques to the commercialized mass production lines, an VLP detecting LFIA kit was developed with a detection limit of 1012 copies/g of VLPs in real samples. Since this proposed method in this study could be easily transformable into other combinations with bioreceptors, it is expected that this technique would be applied to LFIA kit development system and bioreceptor quality management.

A feasibility study on the Application of Europium in the Lateral Flow Assay System with Time Resolved fluorometry (유러피엄을 이용한 측방유동 시분할 형광 분석기법)

  • Jung, JIn-Ha;Nam, Ki-Bong;Ko, Dong-Sup;Moon, Jeong-Dae;Jung, Dong-Suk;Choi, Yeoi-Ryul;Kim, Jae-Hoon
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2004.07a
    • /
    • pp.296-297
    • /
    • 2004
  • 시분할 형광 분석법은 발광하는 형광을 통해 시료내의 미량의 물질을 분석 할 수 있는 분석법으로 생화학, 면역학 등 여러 분야에서 응용되고 있으며 새로운 응용 분야에 대한 연구가 활발하게 진행되고 있다. 본 연구에서는 유러피엄(Europium) 화합물을 면역학적 검출기로 사용한 측방유동 시료(lateral flow assay)를 시분할 형광 분석법으로 측정한 결과를 소개한다.

  • PDF

Production and characterization of monoclonal antibodies against white spot syndrome virus (WSSV) (White spot syndrome virus (WSSV)에 대한 단클론 항체 생산 및 특성 분석)

  • Kyoung-Hui, Kong;Choon-Sup, Kim;Kim, Do-Hyung;Wi-Sik, Kim
    • Journal of fish pathology
    • /
    • v.35 no.2
    • /
    • pp.241-246
    • /
    • 2022
  • White spot syndrome virus (WSSV) is a prevalent and virulent pathogen affecting cultured whiteleg shrimp (Litopenaeus vannamei) in Korea. In this study, seven monoclonal antibodies (mAbs) (10A12, 16C3, 17G4, 21G5, 22C4, 23B6 and 24G6) were produced by using purified WSSV. The reactivity of these mAbs was analysed by Western blot (WB), indirect immunofluorescence (IIF), and lateral flow immunochromatographic assay (LFIA). WB analysis demonstrated that three mAbs (17G4, 22C4, and 23B6) reacted specifically to VP28 with an approximate molecular weight of 24 kDa, mAb 16C3 reacted with approximately 17 kDa. IIF analysis demonstrated specific fluorescence signals on gill tissues of WSSV-infected shrimp, with five mAbs (10A12, 16C3, 22C4, 23B6, and 24G6), pleopods from WSSV-infected shrimp were used for LFIA, where, two mAbs (21G5 and 22C4) exhibited positive reaction. In conclusion, it can be inferred that the mAbs usage and specificity depends on the nature of assay used for diagnosis.