• Title/Summary/Keyword: lateral distance

Search Result 664, Processing Time 0.027 seconds

Morphometric Study of the Nerve Roots Around the Lateral Mass for Posterior Foraminotomy

  • Hwang, Jae-Chan;Bae, Hak-Geun;Cho, Sung-Won;Cho, Sung-Jin;Park, Hyung-Ki;Chang, Jae-Chil
    • Journal of Korean Neurosurgical Society
    • /
    • v.47 no.5
    • /
    • pp.358-364
    • /
    • 2010
  • Objective : Morphometric data on dorsal cervical anatomy were examined in an effort to protect the nerve root near the lateral mass during posterior foraminotomy. Methods : Using 25 adult formalin-fixed cadaveric cervical spines, measurements were taken at the lateral mass from C3 to C7 via a total laminectomy and a medial one-half facetectomy. The morphometric relationship between the nerve roots and structures of the lateral mass was investigated. Results from both genders were compared. Results : Following the total laminectomy, from C3 to C7, the mean of the vertical distance from the medial point of the facet (MPF) of the lateral mass to the axilla of the root origin was 3.2-4.7 mm. The whole length of the exposed root had a mean of 4.2-5.8 mm. Following a medial onehalf facetectomy, from C3 to C7, the mean of the vertical distance to the axilla of the root origin was 2.1-3.4 mm, based on the MPF. Mean vertical distances from the MPF to the medial point of the root that crossed the inferior margin of the intervertebral disc were 1.2-2.7 mm. The mean distance of the exposed root was 8.2-9.0 mm, and the mean angle between the dura and the nerve root was significantly different between males and females, at $53.4-68.4^{\circ}$. Conclusion : These data will aid in reducing root injuries during posterior cervical foraminotomy.

Pelvic, Hip, and Knee Kinematics of Stair Climbing in People with Genu Varum

  • Chae, Yun Won;Park, Seol;Park, Ji Won
    • The Journal of Korean Physical Therapy
    • /
    • v.30 no.1
    • /
    • pp.14-22
    • /
    • 2018
  • Purpose: This study examined the effects of the lower limb alignment on the pelvis, hip, and knee kinematics in people with genu varum during stair walking. Methods: Forty subjects were enrolled in this study. People who had intercondylar distance ${\geq}4cm$ were classified in the genu varum group, and people who had intercondylar distance <4cm and intermalleolar distance <4cm were placed in the control group. 3D motion analysis was used to collect the pelvis, hip, and knee kinematic data while subjects were walking stairs with three steps. Results: During stair ascent, the genu varum group had decreased pelvic lateral tilt and hip adduction at the early stance phase and decreased pelvic lateral tilt at the swing phase compared to the control group. At the same time, they had decreased minimal hip adduction ROM at the early stance and decreased maximum pelvic lateral tilt ROM and minimum hip rotation ROM at the swing phase. During stair descent, the genu varum group had decreased pelvic lateral tilt at the early stance and decreased pelvic lateral tilt and pelvic rotation at the swing phase. In addition, they had decreased pelvic frontal ROM during single limb support and increased knee sagittal ROM during the whole gait cycle. Conclusion: This study suggests that a genu varum deformity could affect the pelvis, hip and knee kinematics. In addition, the biomechanical risk factors that could result in the articular impairments by the excessive loads from lower limb malalignment were identified.

The Surgical Treatment in Type III Acromioclavicular Dislocation Patients Over 45 Years - Primary Clavicular Lateral End Resection Method vs. Conventional Acromioclavicular Joint Reduction Method - (45세 이상의 제 3형 견봉쇄골 관절 탈구 환자의 수술적 치료 - 일차적 쇄골 외측단 절제 술식과 고식적인 견봉쇄골 관절 정복 술식의 비교 -)

  • Moon Eun-Sun;Bae Bong-Hyun;Choi Jin;Kim Myung-Sun
    • Clinics in Shoulder and Elbow
    • /
    • v.8 no.2
    • /
    • pp.88-96
    • /
    • 2005
  • Purpose: To compare and analyze the outcome of primary clavicular lateral end resection method and conventional acromioclavicular (AC) joint reduction method in type III AC dislocation patients over 45 years. Materials and Methods: This study was performed on selected 24 cases of type III AC dislocation patients, over 45 years of age, operated at our hospital from 1998 to 2002. Group I consist of 12 patients who underwent primary clavicular lateral end resection methods (average age: 54.3 years$(45{\sim}72)$). Group II consist of 7 patients using Bosworth methods and 5 patients using Phemister methods (average age: 54.4 years$(45{\sim}71)$). Clinical outcome was evaluated by Weaver and Dunn method. Radiological results were compared by measuring coracoclavicular distance between normal and injured side. Results: As clinical outcome, good was 10 cases(83%); fair 2(17%) in Group I, and good 6(50%); fair 3(25%); poor 3(25%) in Group II. In contrast, the difference of coracoclavicular distance was not statistically significant between two groups before or after surgery, and last follow up. At the last follow up, there was no special correlation between the difference of coracoclavicular distance and clinical outcome. Conclusion: We considered that primary clavicular lateral end resection may be effective for prevention of arthrosis in AC joint in type III AC dislocation patients over 45 years.

Assessment of Dose and Image Quality according to the Change of Distance from Source to Image Receptor and the Examination Posture during the Skull Lateral Radiography (두부 측 방향 방사선검사 시 선원 영상수용체간 거리와 검사 자세 변화가 선량과 영상품질에 미치는 영향)

  • Eun-Hye, Kim;Young-Cheol, Joo;Han-Yong, Kim;Dong-Hwan, Kim
    • Journal of radiological science and technology
    • /
    • v.45 no.6
    • /
    • pp.483-489
    • /
    • 2022
  • This study proposes a new skull lateral examination, and provides an improved examination environment for patients and radiologists. The study was divided into three groups. One group was divided into the SID (source to image receptor distance) 110 ㎝ and 180 ㎝ in the skull lateral posture, the other group The other group was divided into an position in contact with the detector and an position without contact with the detector, and the other group was divided into male and female groups, considering that the difference in shoulder width between adult males and females would affect the dose and image quality. For dose evaluation, the ESD (entrance surface dose) was measured at the EAM (external auditory meatus), and the conditions were applied equally at 70 ㎸p, 200 ㎃, and 10 ㎃s. For image quality evaluation, SNR (signal to noise ratio) and CNR (contrast to noise ratio) were measured in frontal sinus, EAM, and sella turcica. As a result of ESD comparison, when sid 110 ㎝ to sid 180 ㎝ was changed among the three groups, ESD values decreased the most to 729.18±4.62 μ㏉ and 224.18±0.74 μ㏉ at 180 ㎝ (p<0.01). The values of SNR and CNR were statistically significant (p<0.01), but there was no qualitative difference. This shows that when the SID is 180 ㎝, it is possible to reduce the dose without lowering the image quality. So, It is suggested that the SID 180 ㎝ is used without contacting the detector when examining the skull lateral.

EXPERIMENTAL STUDY ON THE RETENTION FORCE OF INLAY CAVITY (와동의 깊이 및 넓이의 변화가 Inlay 유지력에 미치는 영향에 관한 실험적 연구)

  • Hahn, Taik-Seon;Choi, Zai-Kyung
    • The Journal of the Korean dental association
    • /
    • v.9 no.7
    • /
    • pp.431-437
    • /
    • 1971
  • The authors performed an experimental study on the retention force in cavities with various depth and width. We used the simple model cavities which were cylindrically formed to eliminate the unexpected influence during experiment, and obtained following results. 1. The retention force in the cavities with parallel wall was vigorous even in the small cavity and increased considerably followed by extending the cavity size. 2. The ratention force resulted more vigorously by that the depth became deeper than that the distance between the lateral walls became longer. 3. Compared with the retention force in the cavities which had the same frictional lateral surface, it was more vigorous in the deeper cavity than in the cavity which was longer distance between the lateral surfaces.

  • PDF

Sequential Lateral Solidification Process for Fabrication of Crystalline Silicon Thin Film Transistor (단결정 실리콘 TFT 제작을 위한 SLS 공정)

  • Lee, Youn-Jae;Pak, Jung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2000.11c
    • /
    • pp.461-463
    • /
    • 2000
  • This paper presents a low temperature excimer-laser-crystallization that produces directionally solidified microstructure in Si thin films. The process involves (1) a complete melting of selected area via irradiation through a patterned mask. and (2) a precisely controlled pulse translation of the sample with respect to the mask over a distance shorter than the superlateral growth(SLG) distance. (3) lateral growth extended over a number of iterative steps. Grains that grow continuously to the vertical direction were demonstrated. We discuss sequential lateral solidification principle, experiment.

  • PDF

An Basic Study on the Lateral Pressure to the Form for Rammed Earth Method (흙다짐공법에서 거푸집측압에 대한 기초적연구)

  • Lee, Jung Je;Kwak, Yoon Keun;Hwang, Hey Zoo;Lee, Jong Kook
    • KIEAE Journal
    • /
    • v.9 no.1
    • /
    • pp.39-45
    • /
    • 2009
  • The lateral pressure that functions on the form of the rammed earth method occupies an important part in the construction of the form. The following research constructed testing forms of $800mm{\times}1200mm$, that have the wall thickness of 200mm, 300mm, 400mm and 500mm to measure the lateral pressures according to the wall thicknesses. Research showed that compared to the concrete construction lateral pressures, the form results measured 2.3-8.9 times higher, and rather than thickness of the form, the distance between the rammer and mold and assuring time had direct relation to the lateral pressure of the form.

Classification of Lower Body Types of Female Adults aged 18 to 69 based on 3D Body Scan Data - Focusing on the Front Type, Lateral-Front Type, and Lateral-Back Type -

  • Kim, Min Kyoung;Nam, Yun Ja
    • Fashion & Textile Research Journal
    • /
    • v.18 no.1
    • /
    • pp.91-102
    • /
    • 2016
  • This study classified the lower body types of female adults aged 18 to 69. The lower body was divided into front, lateral front, and lateral back. In order to understand the shape and somatotype of each segment, 592 people were analyzed based on girth, height, length, depth, width, angle and cross section distance for each segment. For data analysis, SPSS 18.0 was performed for descriptive statics, principal component analysis, K-means cluster analysis, ANOVA, and Duncan's test (as verification). Factor analysis was performed based on index values, calculation values, angles, and cross section distances. The measured items resulted in a.) 16 items were extracted to 5 factors in the case of the front factor (FF) of the lower body, and b.) 24 items were extracted to 6 factors in the case of lateral front factor (LFF) and lateral back factor (LBF). Each factor was put through K-means cluster analysis, classifying the lower bodies into one of four types of based on the front type (FT), the lateral front type (LFT), and the lateral back type (LBT) respectively. This study proposed an understanding of various lower body shapes by segmenting and classifying the lower body shapes for each type.

A Study on the Fabrication of p-type poly-Si Thin Film Transistor (TFT) Using Sequential Lateral Solidification(SLS) (SLS 공정을 이용한 p-type poly-Si TFT 제작에 관한 연구)

  • Lee, Yun-Jae;Park, Jeong-Ho;Kim, Dong-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.6
    • /
    • pp.229-235
    • /
    • 2002
  • This paper presents the fabrication of polycrystalline thin film transistor(TFT) using sequential lateral solidification(SLS) of amorphous silicon. The fabricated SLS TFT showed high Performance suitable for active matrix liquid crystal display(AMLCD). The SLS process involves (1) a complete melting of selected area via irradiation through a patterned mask, and (2) a precisely controlled pulse translation of the sample with respect to the mask over a distance shorter than the super lateral growth(SLG) distance so that lateral growth extended over a number of iterative steps. The SLS experiment was performed with 550$\AA$ a-Si using 308nm XeCl laser having $2\mu\textrm{m}$ width. Irradiated laser energy density is 310mJ/$\textrm{cm}^2$ and pulse duration time was 25ns. The translation distance was 0.6$\mu$m/pulse, 0.8$\mu$m/pulse respectively. As a result, a directly solidified grain was obtained. Thin film transistors (TFTs) were fabricated on the poly-Si film made by SLS process. The characteristics of fabricated SLS p -type poly-Si TFT device with 2$\mu\textrm{m}$ channel width and 2$\mu\textrm{m}$ channel length showed the mobility of 115.5$\textrm{cm}^2$/V.s, the threshold voltage of -1.78V, subthreshold slope of 0.29V/dec, $I_{off}$ current of 7$\times$10$^{-l4}$A at $V_{DS}$ =-0.1V and $I_{on}$ / $I_{off}$ ratio of 2.4$\times$10$^{7}$ at $V_{DS}$ =-0.1V. As a result, SLS TFT showed superior characteristics to conventional poly-Si TFTs with identical geometry.y.y.y.

Outcomes of Internal Fixation with Compression Hip Screws in Lateral Decubitus Position for Treatment of Femoral Intertrochanteric Fractures

  • Park, Cheon-Gon;Yoon, Taek-Rim;Park, Kyung-Soon
    • Hip & pelvis
    • /
    • v.30 no.4
    • /
    • pp.254-259
    • /
    • 2018
  • Purpose: Internal fixation using compression hip screws (CHS) and traction tables placing patients in the supine position is a gold standard option for treating intertrochanteric fractures; however, at our institution, we approach this treatment with patients in a lateral decubitus position. Here, the results of 100 consecutive elderly (i.e., ${\geq}45$ years of age) patients who underwent internal fixation with CHS in lateral decubitus position are analyzed. Materials and Methods: Between March 2009 and May 2011, 100 consecutive elderly patients who underwent internal fixation with CHS for femoral intertrochanteric fracture were retrospectively reviewed. Clinical outcomes (i.e., Koval score, Harris hip score [HHS]) and radiographic outcomes (i.e., bone union time, amount of sliding of lag screw, tip-apex distance [TAD]) were evaluated. Results: Clinical assessments revealed that the average postoperative Koval score decreased from 1.4 to 2.6 (range, 0-5; P<0.05); HHS was 85 (range, 72-90); and mean bone union time was 5.0 (range, 2.0-8.2) months. Radiographic assessments revealed that anteroposterior average TAD was 6.95 (range, 1.27-14.63) mm; lateral average TAD was 7.26 (range, 1.20-18.43) mm; total average TAD was 14.21 (range, 2.47-28.66) mm; average lag screw sliding was 4.63 (range, 0-44.81) mm; and average angulation was varus $0.72^{\circ}$(range, $-7.6^{\circ}-12.7^{\circ}$). There were no cases of screw tip migration or nonunion, however, there were four cases of excessive screw sliding and six cases of varus angulation at more than $5^{\circ}$. Conclusion: CHS fixation in lateral decubitus position provides favorable clinical and radiological outcomes. This technique is advisable for regular CHS fixation of intertrochanteric fractures.