Assessment of Dose and Image Quality according to the Change of Distance from Source to Image Receptor and the Examination Posture during the Skull Lateral Radiography

두부 측 방향 방사선검사 시 선원 영상수용체간 거리와 검사 자세 변화가 선량과 영상품질에 미치는 영향

  • 김은혜 (삼성서울병원 영상의학과) ;
  • 주영철 (삼성서울병원 영상의학과) ;
  • 김한용 (삼성서울병원 영상의학과) ;
  • 김동환 (삼성서울병원 영상의학과)
  • Received : 2022.09.16
  • Accepted : 2022.12.05
  • Published : 2022.12.31

Abstract

This study proposes a new skull lateral examination, and provides an improved examination environment for patients and radiologists. The study was divided into three groups. One group was divided into the SID (source to image receptor distance) 110 ㎝ and 180 ㎝ in the skull lateral posture, the other group The other group was divided into an position in contact with the detector and an position without contact with the detector, and the other group was divided into male and female groups, considering that the difference in shoulder width between adult males and females would affect the dose and image quality. For dose evaluation, the ESD (entrance surface dose) was measured at the EAM (external auditory meatus), and the conditions were applied equally at 70 ㎸p, 200 ㎃, and 10 ㎃s. For image quality evaluation, SNR (signal to noise ratio) and CNR (contrast to noise ratio) were measured in frontal sinus, EAM, and sella turcica. As a result of ESD comparison, when sid 110 ㎝ to sid 180 ㎝ was changed among the three groups, ESD values decreased the most to 729.18±4.62 μ㏉ and 224.18±0.74 μ㏉ at 180 ㎝ (p<0.01). The values of SNR and CNR were statistically significant (p<0.01), but there was no qualitative difference. This shows that when the SID is 180 ㎝, it is possible to reduce the dose without lowering the image quality. So, It is suggested that the SID 180 ㎝ is used without contacting the detector when examining the skull lateral.

Keywords

References

  1. Joyce KE, Hayaska S, Laurienti PJ. A genetic algorithm for controlling an agent-based model of the functional human brain. Biomed Sci Instrum. 2012;48:210-7.
  2. Khotanlou H, Afrasiabi M. Segmentation of Multiple Sclerosis Lesions in Brain MR Images Using Spatially Constrained Possibilistic Fuzzy C-Means Classification. J Med Signals Sens. 2011;1:149-55.
  3. Kim HJ, Bae WK, Cha JJ, Kim KW, Jo WS, Kim IY, Lee KS. Radiologic Findings of Acute Spontaneous Subdural Hematomas. The Journal of the Korean Radiological Society. 1988;38(3):391-6.
  4. Lee SM. Clinical Feature and Outcome in Spontaneous Cerebellar Hemorrhage: Determination of Treatment Strategies. Journal of the Korean Neurological Association. 2004;22(4):290-4.
  5. Lee YB, Park YS, Lee KC, Kim HS, Mok JH, Park SB. Skull Fracture and Traumaric Intracranial Lesions. Dong-guk Medicine. 1977;4:63-70.
  6. Lee JK. Evaluation of maxillary sinuses and adjacent tissues on panoramic photographs according to head position. The American Academy of Oral and Maxillofacial Radiology. 1992;22(2):315-27.
  7. Ballinger PW. MERRILL'S ATLAS OF RADIOGRAPHIC POSITIONS and RADIOLOGIC PROCEDURES. 8th ed. United State: Mosby-Year Book; 1955:12.
  8. Shin JS, Park CW, Jeon BK. Analysis on infection control of general hospital radiology. Journal of the Korean Society of Radiology. 2012;6(5):335-42. https://doi.org/10.7742/jksr.2012.6.5.335
  9. Size Korea. 7th Human Body Index Report [Internet]; 2015. Available from: https://sizekorea.kr/humanmeas-search/human-data-search/meas-item
  10. Kim JS, Joo YC, Lee SK. Effect of High Tube Voltage and Scatter Ray Post-processing Software on Image Quality and Radiation Dose During Chest Anteroposterior Radiography. Journal of Radiological Science and Technology. 2021;44(4):295-300. https://doi.org/10.17946/JRST.2021.44.4.295
  11. Min JW, Kim JM, Jeong HW. Mixed Noise reduction Filters for CR Images. Journal of Radiological Science and Technology. 2007;30(1):1-6.
  12. Ann KH. Medical-related infection control of diagnostic radiation generator using silver nano antibacterial material [master's thesis]. Incheon: Gachon University; 2019.
  13. Department of Health and Human Services. Guidelines; 2005.
  14. Kim YH, Kwon SI. Effects on Patient Exposure Dose and Image Quality by Increasing Focal Film Distance in Abdominal Radiography. Journal of Korean Society of Radiological Technology. 1988;21(1):52-8.
  15. Joo YC, Jung YJ. Evaluation of Relationship between Radiation Dose and Image Quality according to Source to Image Receptor Distance in Rib Series Radiography. Journal of Radiological Science and Technology. 2018;41(5):391-6. https://doi.org/10.17946/JRST.2018.41.5.391
  16. Park YS, Ann BS. An Experiment on Scattered-ray Content Ratio and Skin Dose according to the Exposure Condition for Chest Radiography. Journal of Korean Society of Radiological Technology. 1992;15(2):3-9.
  17. Park YW. A study on the proper examination distance of a digital X-ray imaging device for diagnosis [master's thesis]. Seosan: Hanseo University Graduate School of Health Promotion; 2014.
  18. Kwon SM, Park CH, Park JK, Song WH, Jung JE. The Effect of Source to Image-Receptor Distance(SID) on Radiation Dose for Digital Chest Radiography. J. Korean Soc. Radiol. 2014;8(4):203-10. https://doi.org/10.7742/JKSR.2014.8.4.203