• Title/Summary/Keyword: lateral compression

Search Result 381, Processing Time 0.025 seconds

Application of EPS Considering Long-term Durability (장기내구성을 고려한 EPS의 현장 적용성)

  • Chun, Byungsik;Jung, Changhee;Ahn, Jinhyun
    • Journal of the Korean GEO-environmental Society
    • /
    • v.8 no.6
    • /
    • pp.53-60
    • /
    • 2007
  • L/EPS, manufactured in the shape of block and used for civil engineering, is a lightweight material with an excellent resistance to compression, and provides a superb self-sufficient stability. EPS is a suitable material capable of resolving the problem of settlement and lateral flow if it is applied as the soil on soft ground. The Korean Standards (KS) has not yet proposed any testing method for use of EPS as an engineering banking material. Only its testing and quality ordinance as a heat insulation material has been standardized. The design criteria for EPS has been established and applied through the trial construction of KHC (Korea Highway Corporation) and quality test of manufacturer, but most studies on them have been confined to factory products. This study is focused on comparing and analyzing long-term durability by conducting cyclic load test, freezing and thawing test, absorption rate test and others. EPS used in the test was chosen from construction sites and factory products, focusing on the long-term durability of EPS depending on the passage of time. Unconfined compression test results indicated that the strength of collected samples was lower than factory products. While the triaxial compression test results indicated that the shear strength increased in proportion to the increase of confining pressure, and factory products had declining shear strength as the confining pressure rose.

  • PDF

Clinical Characteristics of Unstable Pelvic Bone Fractures Associated with Intra-abdominal Solid Organ Injury (불안정성 골반골 골절 손상에서 동반 복부 고형장기 손상의 임상적 특성)

  • Lee, Sang Won;Kim, Sun Hyu;Hong, Eun Seog;Ahn, Ryeok
    • Journal of Trauma and Injury
    • /
    • v.25 no.1
    • /
    • pp.1-6
    • /
    • 2012
  • Purpose: This study analyzed the characteristics of unstable pelvic bone fractures associated with intra-abdominal solid organ injury. Methods: Medical records were retrospectively collected from January 2000 to December 2010 for patients with unstable pelvic bone fractures. Unstable pelvic bone fracture was defined as lateral compression types II and III, antero-posterior compression types II and III, vertical shear and combined type by young classification. Subjects were divided into two groups, with (injured group) and without (non-injured group) intra-abdominal solid organ injury, to evaluate whether the characteristics of the fractured depended on the presence of associated solid organ injury. Data included demographics, mechanism of injury, initial hemodynamic status, laboratory results, revised trauma score (RTS), abbreviated injury scale (AIS), injury severity score (ISS), amount of transfusion, admission to the intensive care unit (ICU), and mortality. Results: The subjects were 217 patients with a mean age of 44 years and included 134 male patients(61.8%). The injured group included 38 patients(16.9%). Traffic accidents were the most common mechanism of injury, and lateral compression was the most common type of fracture in all groups. The initial blood pressure was lower in the injured group, and the ISS was greater. The arterial pH was lower in the injured group, and shock within 24 hours after arrival at the emergency department was more frequent in the injured group. The amount of the transfused packed red blood cells within 24 hours was higher in the injured group than the non-injured group. Invasive treatment, including surgery and angiographic embolization, was more common in the injured group, and the stay in the ICU was longer in the injured group. Conclusion: A need exists to decide on a diagnostic and therapeutic plan regarding the possibility of intra-abdominal solid organ injury for hemodynamically unstable patients with unstable pelvic bone fractures and multiple associated injuries.

Characteristics of Stable Pelvic Bone Fractures with Intra-abdominal Solid Organ Injury (복부 고형장기 손상을 동반한 안정 골반골 골절의 특성)

  • Park, Sang-June;Kim, Sun-Hyu;Lee, Jong-Hwa;Ahn, Ryeok;Hong, Eun-Seog
    • Journal of Trauma and Injury
    • /
    • v.23 no.2
    • /
    • pp.57-62
    • /
    • 2010
  • Purpose: This study analyzed the characteristics of stable pelvic bone fractures with intra-abdominal solid organ injury. Methods: Medical records were retrospectively reviewed from January 2000 to December 2009 of patients with stable pelvic bone fractures. A stable pelvic bone fracture according to Young's classification is defined as a lateral compression type I and antero-posterior compression type I. Subjects were divided into two groups, one with (injured group) and one without (non-injured group) intra-abdominal solid organ injury, to evaluate the dependences of the characteristics on the presence of an intra-abdominal solid organ injury. Data including demographics, mechanism of injury, initial hemodynamic status, laboratory results, Revised Trauma Score (RTS), Abbreviated Injury Scale (AIS), Injury Severity Score (ISS), amount of transfusion, admission to intensive care unit (ICU), and mortality were analyzed. Results: The subjects were 128 patients with a mean age of 42 years old, of whom were 67 male patients (52.3%). The injured group had 21 patients(16.4%), and the most frequent injured solid organ was the liver. Traffic accident was the most common mechanism of injury and lateral compression was the most common type of fracture in all groups. Initial systolic blood pressure was lower in the injured group, and the ISS was greater in the injured group. Arterial pH was lower in the injured group, and shock within 24 hours after arrival at the emergency department was more frequent in the injured group. Transfused packed red blood cells within 24 hours were 8 patients(38.1%) in the injured group and 11 patients(10.3%) in the non-injured group. Conservative treatment was the most common therapeutic modality in all groups. Stay in the ICU was longer in the injured group, and three mortalities occurred. Conclusion: There is a need to decide on a diagnostic and therapeutic plan regarding the possibility of intra-abdominal solid organ injury for hemodynamically unstable patients with stable pelvic bone fractures and for patients with stable pelvic bone fractures along with multiple associated injuries.

Performance Evaluation of Fiber-Reinforced Concrete Compression Members Transversely Constrained by BFRP (BFRP로 횡구속된 섬유 보강 콘크리트 압축부재의 성능평가)

  • Lee, Gyeong-Bok;Lee, Sang-Moon;Jung, Woo-Young
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.42 no.5
    • /
    • pp.607-616
    • /
    • 2022
  • Corrosion and degradation of reinforced structures due to abnormal climates and natural disasters further accelerate the aging of structures. Coping with the decrease in structure performance, many old structures are being repaired and reinforced with low-weight and high-strength materials such as glass fiber composite material (GFRP). To further contribute, this paper focus on a more economical and eco-friendly material, basalt fiber composite (BFRP), which provide a more effective lateral constraint effect for seismic reinforcement. The main variables considered in this study are the curing temperature during the manufacturing of BFRP and the material characteristics of the target concrete member. The lateral constraint reinforcement effect was investigated through the evaluation of the performance of normal concrete and those with improved durability through fiber reinforcement. The reinforcement effect was 3.15 times for normal concrete and 3.72 times for fiber reinforced concrete, and the difference in reinforcement effect due to the improvement of the durability characteristics of the compression member was not significant. Lastly, the performance of the BFRP was compared with the results of the GFRP reinforcement from the previous study. The effect of the BFRP reinforcement was 1.18 times better than that of the GFRP reinforcement.

Experimental Investigation on the Behaviour of CFRP Laminated Composites under Impact and Compression After Impact (CAI) (충격시 CFRP 복합재 판의 거동과 충격후 압축강도에 관한 실험적 연구)

  • Lee, J;Kong, C;Soutis C.
    • Composites Research
    • /
    • v.16 no.4
    • /
    • pp.66-73
    • /
    • 2003
  • The importance of understanding the response of structural composites to impact and CAI cannot be overstated to develop analytical models for impact damage and CAI strength predictions. This paper presents experimental findings observed from quasi-static lateral load tests, low velocity impact tests. CAI strength and open hole compressive strength tests using 3 mm thick composite plates($[45/-45/0/90]_{3s}$- IM7/8552). The conclusion is drawn that damage areas for both quasi-static lateral load and impact tests are similar and the curves of several drop weight impacts with varying energy levels(between 5.4 J and 18.7 J) follow the static curve well. In addition, at a given energy the peak force is in good agreement between the static and impact cases. It is identified that the failure behaviour of the specimens from the CAI strength tests was very similar to that observed in laminated plates with open holes under compression loading. The residual strengths art: in good agreement with the measured open hole compressive strengths. considering the impact damage site area, an equivalent hole. The experimental findings suggest that simple analytical models for the prediction of impact damage area and CAI strength can be developed on the basis of the failure mechanism observed from the experimental tests.

A THREE DIMEMSIONAL PHOTOELASTIC STRESS ANALYSIS OF IMPLANT SUPPORTING BONE TISSUE ACCORDING TO DESIGN OF ATTACHMENTS USED FOR MANDIBULAR OVERDENTURE USING TWO OSSEOINTEGRATED IMPLANSTS (두개의 골유착성 임프란트를 이용한 하악 OVERDENTURE에서 ATTACHMENT 설계에 따른 임프란트 지지조직의 삼차원적 광탄성 응력분석)

  • Shin, Kyoo-Hag;Jeong, Chang-Mo;Jeon, Young-Chan;Hwang, Hie-Seong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.1
    • /
    • pp.31-69
    • /
    • 1996
  • The purpose of this investigation was to analyze stress distribution in implant supporting tissue according to different types of attachments such as combination bar attachment, Hader bar attachment, O-Ring attachment and Dal-Ro attachment that are used in mandibular overdenture by using two osseointegrated implants, to study the influence that POM IMC used in bar type attachment has in implant supporting tissue and compare the preceding analyses to find out an effective stress distribution method. Three dimensional photoelastic method was used to obtain the following results. (A) Analysis of stress distribution according to attachment type 1. Under vertical load condition, compressive stress was seen at implant supporting area of working side on all the photoelastic models but in Hader bar attachment tensional stress was seen at distal upper area of implant supporting area. Relatively Hader bar and O-Ring attachment showed even stress distribution pattern. 2. Under vertical load condition, compressive stress at implant apex area and tensional stress at implant lateral supporting area were seen at nonworking side of all models. 3. Under $25^{\circ}$ lateral load condition, general compressive stress was seen at working side implant supporting area in most of the models, especially at distal upper supporting area higher compressive stress concentration was seen in combination bar attachment and tensional stress concentration, in Hader bar attachment. 4. Under $25^{\circ}$ lateral load condition, compressive stress at implant apex area and tensional stress at implant lateral supporting area were seen at nonworking side of all models, except O-Ring model which showed compressive stress only. (B) Influence of POM IMC to stress distribution in bar type attachment 5. Under vertical load condition, better stress distribution pattern was seen at working side of combination bar and Hader bar attachment model using POM IMC. 6. Under vertical load condition, stress value was increased at nonworking side of combination bar attachment model using POM IMC and tendency of increasing compression was seen at nonworking side of Hader bar attachment model using POM IMC. 7. Under $25^{\circ}$ lateral load condition, better stress distribution pattern was seen at working side of combination bar attachment model using POM IMC but tendency of increasing stress was seen on working side of Hader bar attachment model using POM IMC. 8. Under $25^{\circ}$ lateral load condition, stress reduction was seen at nonworking side of combination bar attachment model using POM IMC but tendency of increasing stress was seen at nonworking side of Hader bar attachment model using POM IMC.

  • PDF

CONDYLAR ADAPTATION UNDER LATERAL DEVIATION OF THE RABBIT MANDIBLE (가토의 하악골 측방 변위에 의한 하악과두 변화)

  • Park, Hae-Sung;Park, Young-Ju;Ahn, Byoung-Keun;Rhee, Gun-Joo;Park, Jun-Woo;Lee, Young-Chan;Cho, Byoung-Ouck
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.26 no.5
    • /
    • pp.446-454
    • /
    • 2000
  • Condylar process of mandible is an important and fuctionally versatile part of the mandible. There were quite large amount of investigations on the functional and anatomical adaptation of the temporomandibular joint(TMJ) to the surrounding tissues. But controversies on the mechanism of functional adaptation of the joint still exist. In this research, we investigated changes in the TMJ by the lateral deviation of the maxillary incisor to shift the mandible right, and bone the undecalcified microscopic sections with fluorescent microscope and von Kossa staining with bright field microscope. Results were as follows: 1. Lateral deviation rendered shifting and tilting of the mandible, There were, compressions in the right joint and opening of the left joint space at early stage. At the same time, both condyles shifted slightly to anterior. 2. After $2{\sim}4$ weeks, left condyle showed anterior displacement and compressions in the joint space. Right condyle showed only slight shift to the anterior. 3. Regardless of the direction of the lateral shift, anterior bite plate compressed both condyle heads until 2 weeks. 4. There are bone resorptions in the anterior aspect of the condyle head and apposition of posterior border. Bone remodeling were observed between 3 and 4 weeks. 5. After 8 weeks of the experiment, there were little differences in condylar morphology between experimental and control group, though slight shifting and compression were still present in the experimental group. Lateral deviation of mandible evoked active remodeling of the TMJ until functional and anatomical reconstruction of TMJ position was achieved.

  • PDF

Nineth Rib Syndrome after 10th Rib Resection

  • Yu, Hyun Jeong;Jeong, Yu Sub;Lee, Dong Hoon;Yim, Kyoung Hoon
    • The Korean Journal of Pain
    • /
    • v.29 no.3
    • /
    • pp.185-188
    • /
    • 2016
  • The $12^{th}$ rib syndrome is a disease that causes pain between the upper abdomen and the lower chest. It is assumed that the impinging on the nerves between the ribs causes pain in the lower chest, upper abdomen, and flank. A 74-year-old female patient visited a pain clinic complaining of pain in her back, and left chest wall at a 7 on the 0-10 Numeric Rating scale (NRS). She had a lateral fixation at T12-L2, 6 years earlier. After the operation, she had multiple osteoporotic compression fractures. When the spine was bent, the patient complained about a sharp pain in the left mid-axillary line and radiating pain toward the abdomen. On physical examination, the $10^{th}$ rib was not felt, and an image of the rib-cage confirmed that the left $10^{th}$ rib was severed. When applying pressure from the legs to the $9^{th}$ rib of the patient, pain was reproduced. Therefore, the patient was diagnosed with $9^{th}$ rib syndrome, and ultrasound-guided $9^{th}$ and $10^{th}$ intercostal nerve blocks were performed around the tips of the severed $10^{th}$ rib. In addition, local anesthetics with triamcinolone were administered into the muscles beneath the $9^{th}$ rib at the point of the greatest tenderness. The patient's pain was reduced to NRS 2 point. In this case, it is suspected that the patient had a partial resection of the left $10^{th}$ rib in the past, and subsequent compression fractures at T8 and T9 led to the deformation of the rib cage, causing the tip of the remaining $10^{th}$ rib to impinge on the $9^{th}$ intercostal nerves, causing pain.

Medial Loop of V2 Segment of Vertebral Artery Causing Compression of Proximal Cervical Root

  • Park, Sung Bae;Yang, Hee-Jin;Lee, Sang Hyung
    • Journal of Korean Neurosurgical Society
    • /
    • v.52 no.6
    • /
    • pp.513-516
    • /
    • 2012
  • Objective : It is rare that the medial loop in the V2 segment of the vertebral artery (VA) causes compression of the proximal cervical root of the spinal cord without leading to bony erosion and an enlarged foramen. We evaluated the clinical significance and incidence of the medial loop in the V2 segment of the VA. Methods : We reviewed the records from 1000 consecutive patients who had undergone magnetic resonance imaging evaluation of the cervical spine between January 2005 and January 2008. The inclusion criteria were that over a third of the axial aspect of the VA located in the intervertebral foramen was inside the line between the most ventral points of the bilateral lateral mass, and that the ipsilateral proximal root deviated dorsally because of the medial loop of the VA. We excluded cases of bone erosion, a widened foramen at the medial loop of the VA, any bony abnormalities, tumors displacing VA, or vertebral fractures. The medical records were reviewed retrospectively to search for factors of clinical significance. Results : In six patients (0.6%), the VA formed a medial loop that caused compression of the proximal cervical root. One of these patients had the cervical radiculopathy that developed after minor trauma but the others did not present with cervical radiculopathy related to the medial loop of the VA. Conclusion : The medial loop of the VA might have a direct effect on cervical radiculopathy. Therefore, this feature should be of critical consideration in preoperative planning and during surgery.

Kyphotic Angle Measurement Accuracy for Vertebral Osteoporotic Compression Fracture; Reliable Method for Kyphotic Angle Measurement

  • Hong, Jae-Taek;Lee, Sang-Won;Son, Byung-Chul;Sung, Jae-Hoon;Park, Choon-Keun;Kim, Moon-Chan
    • Journal of Korean Neurosurgical Society
    • /
    • v.39 no.4
    • /
    • pp.256-259
    • /
    • 2006
  • Objective : Having a reliable and reproducible measurement technique to measure the sagittal contour in vertebral fractures is paramount to clinical decision making. This study is designed to determine the most reliable measurement technique in osteoporotic vertebral compression fracture. Methods : Fifteen lateral radiographs of thoracic and lumbar fractures were selected and measured on two separate occasions by three spine surgeons using six different measurement techniques [Centroid, Harrison Posterior Tangent Methods and 4 different types of modified Cobb method]. The radiograph quality was assessed and the center beam location was determined. Statistical analysis including ANOVA for repeated measures was carried out using the SAS software [v 8.0]. Results : The inter and intraobserver variance of the Cobb method 4 and Harrison posterior tangent method were significantly lower than the other four methods. The intraobserver correlation coefficients were the most consistent using the Cobb method 4 [0.982]. which was followed by the Harrison posterior tangent [0.953] and Cobb methods 1 [0.874]. The intraobserver agreement [% of repeated measures within 5 degrees of the original measurement] ranged from 42% to 98% for each technique for all three observers, with the Cobb method 4 showing the best agreement [97.8%] followed by the Harrison posterior tangent method [937%]. Conclusion : The Cobb method-4 and Harrison posterior tangent methods, when applied to measuring the kyphosis, are reliable and have a similar small error range. The Cobb method 4 shows the best overall reliability. However, the centroid method and Cobb method using a fractured endplate do not produce an accurate result due to inter and intraobserver differences in determining the baseline.