• Title/Summary/Keyword: laser dentistry

Search Result 571, Processing Time 0.032 seconds

A STUDY FOR THERMAL CONDUCTIVITY OF IRRADIATED CAVITY (와동내에 조사된 열의 전도양상에 관한 연구)

  • Baik, Byeong-Ju;Kim, Jae-Gon;Hur, Sun;Lee, Du-Cheol;Yun, Hyun-Du
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.25 no.3
    • /
    • pp.583-597
    • /
    • 1998
  • The purpose of this study was to evaluate temperature change occurred in enamel, dentin and pulp due to the heat from cavity prepration with laser. We made three models had different cavity depth: cavity depth of model A was 3.52mm, model B was 2.32mm, model C was 1.16mm. We irradiated cavity base with thermal capacity of $30J,100J,300J/cm^2s$ during few seconds and studied the change of temperature in tooth during 10 seconds, and estimated change of thermal capacity by different irradiated site and exposure time. At $300J/cm^2$ irradiation for 2 seconds, the temperature of irradiated surface was elevated fast according to irradiated thermal energy during 1 second. In proportion to continuous exposure time, temperature elevated slowly. The surface temperature was $1370^{\circ}C$. After discontinue of thermal irradiation, the heat of irradiated surface was diffused in dentin and pulp and the greatest temperature was made. The greatest temperature was disappeared within 10 seconds The greatest temperature of the inner part of model brought about very severe change by different depth. Temperature in pulp was raised by the greater irradiated energy density and exposure time.

  • PDF

Minimally Invasive Laser-Assisted Biopsy of the Oral Lesions for Oral Graft-Versus-Host Disease after Hematopoietic Stem-Cell Transplantation (조혈줄기세포이식후 발생한 이식편대숙주병의 구강병소에 대한 최소침습적 레이저조직생검 증례)

  • Kim, Yun-Mi;Yun, Hee-Jung;Kim, Hyun-Sil;Kim, Kee-Deog;Jung, Bock-Young;Pang, Nan-Sim;Park, Won-Se
    • Journal of Oral Medicine and Pain
    • /
    • v.37 no.3
    • /
    • pp.147-154
    • /
    • 2012
  • Hematopoietic stem-cell transplantation (HSCT) is a treatment for immune deficiency, autoimmune diseases, and hematopoietic malignancies. The main complication of allogenic HSCT is graft-versus-host disease (GVHD). Oral mucosal biopsy is needed for a definitive diagnosis and treatment planning of GVHD, but this procedure causes bleeding and bacteremia in a poor general condition. We evaluated the efficacy of laser-assisted biopsy as a minimally invasive treatment. Three cases were described in this article. All patients' medical records, clinical photographs, and histopathologic findings were reviewed. All patients felt comfortable and no severe complications occurred. The quality of the obtained biopsy material was adequate for a definitive diagnosis of GVHD. Laser-assisted, minimally invasive biopsy of the oral mucosa does not cause bleeding, and it reduces the chances of infection, bacteremia, and postoperative scarring compared to the usual histopathologic biopsy procedure. It would thus be advantageous to use this procedure to biopsy GVHD patients.

A HISTOLOGIC STUDY ON THE EFFECT OF LASER ON THE PERIODONTIUM OF THE ORTHODONTICALLY MOVED TOOTH OF RAT (백서 치아이동에 미치는 LEASER의 영향에 관한 조직학적 연구)

  • Jang, Dong-Soo;Rhee, Byung Tae
    • The korean journal of orthodontics
    • /
    • v.18 no.2
    • /
    • pp.435-447
    • /
    • 1988
  • This study was performed to evaluate the effect of low-power laser irradiation on the periodontium of the orthodontically moved tooth of rat. The experimental materials were 30 male rats. Orthodontic appliances were placed bilaterally between maxillary first molar and incisor teeth and the force was 1 Oz. Experimental animals were divided into eight groups as follows: no movement, 1st, 2nd, 3rd, 5th, 7th, 14th, and 28th day groups. In all experimental animals except no movement group, low-power laser was irradiated on the unilateral maxillary first molar (experimental side), but on the contralateral side, only orthodontic force was applied (control side). The histologic effects of laser on the periodontium of the orthodontically moved tooth on the consecutive experimental days were as follows: In the experimental side, by the biostimulating effect of laser, 1. Hyalinized tissue was formed later and eliminated earlier than in the control side. 2. Undermining bone resorption was occurred earlier than in the control side. 3. More osteoid tissue was deposited and calcified earlier than in the control side. 4. The most prominent changes were formation of new blood vessels and dilatation of old blood vessels.

  • PDF

Analysis of temperature changes and sterilization effect of diode laser for the treatment of peri-implantitis by wavelength and irradiation time (임플란트 주위염 치료용 diode laser의 파장 및 조사시간에 따른 온도 변화와 살균효과 분석)

  • Seol, Jeong-Hwan;Lee, Jun Jae;Kum, Kee-Yeon;Lee, Jong-Ho;Lim, Young-Joon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.3
    • /
    • pp.178-188
    • /
    • 2017
  • Purpose: We compared the effects of newly developed diode laser (Bison 808 nm Diode laser) on the treatment of peri-implantitis with conventional products (Picasso 810 nm Diode laser) by comparing the surface temperature of titanium disc and bacterial sterilization according to laser power. Materials and Methods: The titanium disc was irradiated for 60 seconds and 1 - 2.5 W using diode laser 808 nm and 810 nm. The surface temperature of the titanium disc was measured using a temperature measurement module and a temperature measurement program. In addition, in order to investigate the sterilizing effect according to the laser power, 808 nm laser was irradiated after application of bacteria to sandblasted large-grit acid-etched (SLA) and resorbable blast media (RBM) coated titanium discs. The irradiated disks were examined with scanning electron microscopy. Results: Both 808 nm and 810 nm lasers increased disk surface temperature as the power increased. When the 810 nm was irradiated under all conditions, the initial temperature rise rate, the descending rate, and the temperature change before and after was higher than that of 808 nm. Disk surface changes were not observed on both lasers at all conditions. Bacteria were irradiated with 808 nm, and the bactericidal effect was increased as the power increased. Conclusion: When applying these diode lasers to the treatment of peri-implantitis, 808 nm which have a bactericidal effect with less temperature fluctuation in the same power conditions would be considered safer. However, in order to apply a laser treatment in the dental clinical field, various safety and reliability should be secured.

EFFECTS OF ND:YAG LASER IRRADIATION AND FLUORIDE APPLICATION ON REMINERALIZATION OF THE ENAMEL (Nd:YAG 레이저 조사와 불화물 도포가 탈회법랑질의 재광화에 미치는 영향)

  • Cho, Hyun;Kim, Dae-Eop;Lee, Kwang-Hee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.3
    • /
    • pp.381-390
    • /
    • 2004
  • The purpose of this in vitro study was to investigate the effects of Nd:YAG laser irradiation and fluorides on acid drink demineralized enamel. The materials were 30 freshly extracted permanent premolars with intact smooth enamel surfaces. They were demineralized with Coca-cola at $37^{\circ}C$ for 12hours and then irradiated by Nd:YAG laser with 6W power, $50mJ/cm^2$ energy density, and 20Hz pulse repetition. After laser irradiation, teeth were treated by three kinds of fluorides; (1)0.05% NaF fluoride solution (2)1.23% APF gel and (3)0.1%F fluoride varnish, microhardness(VHN) and Diagnodent scores were measured and the surfaces of each treated specimens were also observed with SEM under 1500 magnification. The results were as follows: 1. In the change of microhardness(VHN), it decreased to 34.68% from the initial micrhardness, increased to 78.37% after laser irradiation and increased to 82.62% after fluoride treatment, there were significant differences except when it was irradiated and treated with fluoride(P<0.05). 2. In the change of Diagnodent scores, it was decreased to 28.08% from the initial scores after demineralization, and then increased to 59.81% after laser irradiation, and increased to 82.17% after fluoride treatment. Scores were different significantly between the scores of initial, demineralization, laser irradiation and fluoride treatment(P<0.05). All the scores were not different significantly between fluoride types. 3. SEM observation showed that the lased enamel surfaces after demineralization were thermally degenerated and showed molten lava-like appearance and crater with cracks and many microholes.

  • PDF

Use of piezoelectric surgery and Er:YAG laser:which one is more effective during impacted third molar surgery?

  • Keyhan, Seied Omid;Fallahi, Hamid Reza;Cheshmi, Behzad;Mokhtari, Sajad;Zandian, Dana;Yousefi, Parisa
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.41
    • /
    • pp.29.1-29.10
    • /
    • 2019
  • Background: Reduction in postoperative complications is of vital considerations in impacted third molar teeth surgery. The aim of this study was to compare postoperative complications of impacted third molar surgeries for bone removal using laser, piezoelectric equipment, and conventional rotary instruments. Methods: To address the research purpose, the investigator designed the prospective double-blind clinical trial study. The sample size was determined 20 (40 teeth) by sampling formula in any kind of operation. The data of patients were obtained in the different periods in terms of pain, trismus, swelling, ecchymosis, and patient's satisfaction and then analyzed using SPSS 20 software via paired t test and Wilcoxon and McNemar's tests. Results: The pain immediately after surgery and 2 days and 7 days after surgery was higher in the laser group. The swelling immediately after surgery was more in the laser group but not significant. The amount of mouth opening immediately after surgery and 2 days and 7 days after surgery was significantly lower in the laser group than in the piezosurgery group. The total duration of surgery and duration of osteotomy were significantly longer in the laser group. The patient's satisfaction from surgery with piezosurgery was more than that with laser, but this difference was not significant. Conclusion: Due to the rising demand for impacted wisdom tooth surgery, the present study suggests that hard tissue laser surgery and piezosurgery can clear the future of impacted molar surgery, and these approaches are more efficient in reducing postoperative complications compared to the conventional surgeries.

A COMPARATIVE STUDY OF WOUND HEALING AFTER SKIN INCISION WITH SCALPEL, $CO_2$, AND Nd:YAG LASER IN RATS (수술칼, $CO_2$ 및 Nd:YAG 레이저에 의한 절개 창상의 치유에 관한 비교 연구)

  • Choi, Jae-Sun;Ryu, Sun-Youl
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.22 no.1
    • /
    • pp.33-42
    • /
    • 2000
  • The purpose of this study was to compare the wound healing process after skin incision using scalpel, $CO_2$ laser and pulsed Nd:YAG laser in rats. After skin on the back was incised 3 cm long, rats were sacrificed at 1, 3, 7, 14, 21 and 28 days. Macroscopic, histologic and immunohistochemical examinations using the collagen type IV and the CD34 antibodies which are necessary to the forming process of new capillary were performed. Results obtained were as follows ; Macroscopically the initial wound healing of the laser group was about $1{\sim}2$ weeks slower than that of the scalpel group. There weren't however any remarkable differences in all groups in 4 weeks after incision. By histologic finding, acute inflammatory cells were more prominent during the initial wound healing in the scalpel group than in the other groups. Epithelialization started in the order of scalpel, $CO_2$ and Nd:YAG laser group after skin incision. By the Masson's trichrome stain, collagen synthesis in the Nd:YAG laser group was more slowly initiated than in the other groups. But it was completed at the $3{\sim}4$ weeks in all groups. Immunohistochemically, collagen type IV and CD34 expression were markedly increased at 2 weeks in the scalpel and $CO_2$ laser group. Meanwhile, in the Nd:YAG laser group, these reactions were observed later tan the other groups. Collagen type IV and CD34 expression were decreased in all groups after 4 weeks. These results suggest that $CO_2$ and Nd:YAG laser showed similar healing process compared with scalpel and a potential substitute for scalpel in skin incision.

  • PDF

Antimicrobial Effect of Photodynamic Therapy Using Plaque Disclosing Agent (치면착색제를 이용한 광역동 치료의 항균 효과)

  • Kho, Junhee;Park, Howon;Lee, Juhyun;Seo, Hyunwoo;Lee, Siyoung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.47 no.2
    • /
    • pp.120-127
    • /
    • 2020
  • The aim of this study was to evaluate the antimicrobial effect of photodynamic therapy (PDT) using plaque disclosing agent, 10 - 20 mM erythrosine, as a photosensitizer. Multispecies cariogenic biofilms containing Streptococcus mutans, Lactobacillus casei and Candida albicans were formed on hydroxyapatite disc. 20 μM, 10 mM and 20 mM erythrosine were applied as a photosensitizer for 3 minutes, and then light-emitting diode (LED) irradiated for 24 seconds. Colony-forming unit (CFU) were measured and biofilms were observed using confocal laser scanning microscopy (CLSM). CFU were significantly decreased in the PDT groups using 10 - 20 mM erythrosine (10 mM, 20mM) and the results were also confirmed by CLSM. This study confirms the high antimicrobial effect of photodynamic therapy using plaque disclosing agent as a photosensitizer.

Shear bond strength of a new self-adhering flowable composite resin for lithium disilicate-reinforced CAD/CAM ceramic material

  • Erdemir, Ugur;Sancakli, Hande Sar;Sancakli, Erkan;Eren, Meltem Mert;Ozel, Sevda;Yucel, Taner;Yildiz, Esra
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.6
    • /
    • pp.434-443
    • /
    • 2014
  • PURPOSE. The purpose of this study was to evaluate and compare the effects of different surface pretreatment techniques on the surface roughness and shear bond strength of a new self-adhering flowable composite resin for use with lithium disilicate-reinforced CAD/CAM ceramic material. MATERIALS AND METHODS. A total of one hundred thirty lithium disilicate CAD/CAM ceramic plates with dimensions of $6mm{\times}4mm$ and 3 mm thick were prepared. Specimens were then assigned into five groups (n=26) as follows: untreated control, coating with $30{\mu}m$ silica oxide particles ($Cojet^{TM}$ Sand), 9.6% hydrofluoric acid etching, Er:YAG laser irradiation, and grinding with a high-speed fine diamond bur. A self-adhering flowable composite resin (Vertise Flow) was applied onto the pre-treated ceramic plates using the Ultradent shear bond Teflon mold system. Surface roughness was measured by atomic force microscopy. Shear bond strength test were performed using a universal testing machine at a crosshead speed of 1 mm/min. Surface roughness data were analyzed by one-way ANOVA and the Tukey HSD tests. Shear bond strength test values were analyzed by Kruskal-Wallis and Mann-Whitney U tests at ${\alpha}=.05$. RESULTS. Hydrofluoric acid etching and grinding with high-speed fine diamond bur produced significantly higher surface roughness than the other pretreatment groups (P<.05). Hydrofluoric acid etching and silica coating yielded the highest shear bond strength values (P<.001). CONCLUSION. Self-adhering flowable composite resin used as repair composite resin exhibited very low bond strength irrespective of the surface pretreatments used.

Comparison of the mechanical properties and microstructures of fractured surface for Co-Cr alloy fabricated by conventional cast, 3-D printing laser-sintered and CAD/CAM milled techniques (주조, 3-D printing을 활용한 laser sintered 및 CAD/CAM milled 기법을 이용하여 제작된 코발트-크롬 합금의 물리적 성질 및 파절 단면 관찰 비교 연구)

  • Choi, Yun-Jung;Koak, Jai-Young;Heo, Seong-Joo;Kim, Seong-Kyun;Ahn, Jin-Soo;Park, Dong-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.2
    • /
    • pp.67-73
    • /
    • 2014
  • Purpose: The purpose of present study is to compare mechanical properties and microstructural characteristics of fractured surface for cast, 3-D printing laser sintered and CAD/CAM milled cobalt-chromium (Co-Cr) alloy specimens and to investigate whether laser sintered technique is adequate for dental applications. Materials and methods: Thirty six flat disc shape Co-Cr alloy specimens were fabricated for surface hardness test and divided into three groups according to the manufacturing methods; 12 specimens for casting (n=12), 12 specimens for laser sintered technology (n=12) and 12 specimens for milled technology (n=12). Twelve dumbbell shape specimens for each group were also fabricated for a tensile test. Statistical comparisons of the mechanical properties for the alloys were performed by Kruskal-Wallis test followed by Mann-Whitney and Bonferroni test. The microstructural characteristics of fractured surfaces were examined using SEM. Results: There were significant differences in the mean Vickers hardness values between all groups and the cast specimen showed the highest (455.88 Hv) while the CAD/CAM milled specimen showed the lowest (243.40 Hv). Significant differences were found among the three groups for ultimate tensile strength, 0.2% yield stress, elongation, and elastic modulus. The highest ultimate tensile strength value (1442.94 MPa) was shown in the milled group and the highest 0.2% yield strength (1136.15 MPa) was shown in the laser sintered group. Conclusion: Different manufacturing methods influence the mechanical properties and microstructure of the fractured surfaces in Co-Cr alloys. The cast Co-Cr alloy specimens showed the highest Vickers hardness, and the CAD/CAM milled specimens revealed the highest tensile strength value. All alloys represent adequate mechanical properties satisfying the ISO standards of dental alloy.