• Title/Summary/Keyword: large-area panel

Search Result 168, Processing Time 0.023 seconds

AMLCD for TV Applications;New Challenge for LCD

  • Jun, Hyung-Souk;Kim, K.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2000.01a
    • /
    • pp.223-224
    • /
    • 2000
  • As technology level of TFT-LCD advances, application to TV becomes an emerging important area for LCD makers. In this paper, we review current LCD technology level to be used in TV such as liquid crystal response behavior, color accuracy, contrast ratio, brightness and panel size. Based on the understanding of current limitations in LCD compared with CRT, the improvement plan to render 'near perfect motion picture' reproduction with LCD is proposed. Digital TV is a great opportunity for digital LCD panels, but we have to solve remaining technical and cost issue in order to be competitive with other large size TV technologies such as PDP, CRT or projection type. In preparing the upcoming digital TV era with advanced TFT-LCD, the hurdles and prospect of larger size LCD-TV panels will be discussed.

  • PDF

New Inorganic Vertical Alignment Material Suitable for Large Area LCD Panel

  • Rho, Soon-Joon;Hiroyuki, Kamiya;Jeon, Baek-Kyun;Kim, Kyeong-Hyeon
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.330-333
    • /
    • 2005
  • We investigated the liquid crystal (LC) alignment phenomena using a-C:H and a-C:F:H thin films. Homogeneous alignment is obtained using ion beam treated hydrogenated amorphous carbon (a-C:H) thin films. Homeotropic alignment is obtained using F treated a-C:H thin films, namely, fluorinated amorphous carbon (a-C:F:H) thin films. We investigated the relationship between the surface properties of amorphous carbon based alignment layer and LC alignment phenomena.

  • PDF

The illumination system design of Integrated Screen 3D Display

  • Lin, Chu-Hsun;Lin, Chun-Chuan;Lo, Hsin-Hsiang;Chung, Shuang-Chao;Chen, Tian-Yuan;Wang, Chy-Lin
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.1379-1382
    • /
    • 2009
  • The 3D display has been used in optical projection technology to connect twenty mini- projectors with seamless image tiling. In this way, we can improve the projected resolution by reducing each project screen and increase projected area by connect several mini-projectors. In this article, the illumination system uses the LED light source, non- telecentric structure and LCOS panel, and it's total length is less than 10 centimeter. It can build a seamless large display by tiling multiple projectors.

  • PDF

The Optimum Phosphor Thickness to Obtain the Highest Luminance and Luminous Efficiency in ac PDP

  • Heo, Jeong-Eun;Kim, Young-Kee;Park, Hun-Gun;Park, Chung-Hoo
    • Journal of Information Display
    • /
    • v.2 no.1
    • /
    • pp.14-19
    • /
    • 2001
  • Plasma display panel(PDP) have gained great attention due to their potential application to large-area display including HDTV. The luminance and luminous efficiency of PDP, however, should be improved to realize this goal. In this study, we examined experimentally the effects of phosphor thickness and discharge gap on the luminance and luminous efficiency of ac PDP. For the rib height of 110 ${\mu}m$, whereas the optimum phosphor thickness was about 30 ${\mu}m$. The optimum thickness of green phosphor was about 50 ${\mu}m$ for the rib height of $120{\sim}160\;{\mu}m$.

  • PDF

Split sputter mode: a novel sputtering method for flat-panel display manufacturing

  • Pieralisi, Fabio;Hanika, Markus;Scheer, Evelyn;Bender, Marcus
    • Journal of Information Display
    • /
    • v.12 no.2
    • /
    • pp.89-92
    • /
    • 2011
  • Advanced static DC magnetron sputtering methods based on the magnet wobbling technique were investigated to achieve highly uniform and homogeneous metallization layers. The novel split sputter mode (SSM) method, wherein the deposition process is divided into two distinct steps, enables the AKT rotary cathode technology to provide excellent layer properties, while keeping a high production throughput. The effectiveness of theSSMtechnique was demonstrated through copper-coated large-area substrates.

X-ray properties measurement of Flat panel Digital X-ray gas detector (평판형 디지털 엑스레이 가스 검출기의 엑스선 특성 측정기술에 관한 연구)

  • Yoon, Min-Seok;Cho, Sung-Ho;Oh, Kyung-Min;Jung, Suk-Hee;Nam, Sang-Hee;Park, Ji-Goon
    • Journal of the Korean Society of Radiology
    • /
    • v.3 no.1
    • /
    • pp.17-21
    • /
    • 2009
  • The Recently, large area matrix-addressed image detectors are investigated for X-ray imaging with medical diagnostic and other applications. In this paper, a new flat panel gas detector for diagnostic X-ray imaging is proposed, and its characteristics are investigated. The research of flat panel gas detector is not exist at all. Because of difficulty to inject gas against to atmospheric pressure. So almost gas detector made by chamber shape. We made flat panel sample by display technique. (ex: PDP, Fed, etc.) The experimental measurements, the transparent electrodes, dielectric layer, and the MgO protection layer were formed in front glass. And, the X-ray phosphor layer and address electrodes are formed in the rare glass. The dark current, the x-ray sensitivity and linearity as a function of electric field were measured to investigate the electrical properties. From the results, the stabilized dark current density and the significant x-ray sensitivity were obtained. And the good linearity as a function of exposure dose was showed in wide diagnostic energy range. These results means that the passive matrix-addressed flat panel gas detector can be used for digital x-ray imaging.

  • PDF

Development of $14"{\times}8.5"$ active matrix flat-panel digital x-ray detector system and Imaging performance (평판 디지털 X-ray 검출기의 개발과 성능 평가에 관한 연구)

  • Park, Ji-Koon;Choi, Jang-Yong;Kang, Sang-Sik;Lee, Dong-Gil;Seok, Dae-Woo;Nam, Sang Hee
    • Journal of radiological science and technology
    • /
    • v.26 no.4
    • /
    • pp.39-46
    • /
    • 2003
  • Digital radiographic systems based on solid-state detectors, commonly referred to as flat-panel detectors, are gaining popularity in clinical practice. Large area, flat panel solid state detectors are being investigated for digital radiography. The purpose of this work was to evaluate the active matrix flat panel digital x-ray detectors in terms of their modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE). In this paper, development and evaluation of a selenium-based flat-panel digital x-ray detector are described. The prototype detector has a pixel pitch of $139\;{\mu}m$ and a total active imaging area of $14{\times}8.5\;inch^2$, giving a total 3.9 million pixels. This detector include a x-ray imaging layer of amorphous selenium as a photoconductor which is evaporated in vacuum state on a TFT flat panel, to make signals in proportion to incident x-ray. The film thickness was about $500\;{\mu}m$. To evaluate the imaging performance of the digital radiography(DR) system developed in our group, sensitivity, linearity, the modulation transfer function(MTF), noise power spectrum (NPS) and detective quantum efficiency(DQE) of detector was measured. The measured sensitivity was $4.16{\times}10^6\;ehp/pixel{\cdot}mR$ at the bias field of $10\;V/{\mu}m$ : The beam condition was 41.9\;KeV. Measured MTF at 2.5\;lp/mm was 52%, and the DQE at 1.5\;lp/mm was 75%. And the excellent linearity was showed where the coefficient of determination ($r^2$) is 0.9693.

  • PDF

Elderly response to alteration of existing house function in housing improvement area (주거지 재생지역의 기존주택 기능전환에 대한 노인의 반응연구)

  • Lim, Soo-Hyun;Lee, Yeun-Sook
    • KIEAE Journal
    • /
    • v.10 no.2
    • /
    • pp.9-18
    • /
    • 2010
  • As an aging population has increased vastly and nuclear families have been a dominating family type in modern Korean society, the numbers of the elderly who suffer Empty Nest Syndrome and LID (Loss Isolation Depression) syndrome have been accelerated. These syndromes involve psychological instability, melancholy, and lethargy. To make the elderly get out of this phenomenon and live actively, the scheme of converting their existing house into shared housing was set as a hypothetical solution in this study. This study sets out to find out responses of the elderly to alter their own house's function in housing improvement area. A Small Workshop Panel method was used and the elderly aged 55 years upwards took part and they own a detached house in a housing improvement area that is relatively large for the elderly or the elderly couple to live alone. Through the workshop, problems that the elderly have been experiencing within their houses were looked into and responses of the elderly on altering their house to shared housing by introducing developed schematic plans. Although, the first response was negative, positive responses from the house owners were carried out when a visual support i.e. developed shared housing plan was provided. The positive response was based on the fact that subsidies from the government on house renovation and tenants matching programs are supported as shared housing could provide home owners economical support with rents and help them to feel less lonely. This is a way of relieving the elderly from being neglected and supporting them to live and age actively in their later lives. Furthermore, by providing a visual media to the elder residents in housing improvement area, their greater understandings on the development and addressing their opinions were possible. Therefore, more tools that promote elder residents' participation are needed for future housing improvement projects and an aging society.

The Poly-Si Thin Film Transistor for Large-area TFT-LCD (대면적 TFT-LCD를 위한 다결정 실리콘 박막 트랜지스터)

  • 이정석;이용재
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.24 no.12A
    • /
    • pp.2002-2007
    • /
    • 1999
  • In this paper, the n-channel poly-Si thin-film transistors (poly-Si TFT's) formed by solid phase crystallization (SPC) on glass were investigated by measuring the electrical properties of poly-Si films, such as I-V characteristics, mobility, leakage current, threshold voltage, and subthreshold slope. It is done to decide to be applied on TFT-LCD with large-size and high density. In n-channel poly-Si TFT with 2, 10, 25$\mu\textrm{m}$ of channel length, the field effect mobilities are 111, 126 and 125 $\textrm{cm}^2$/V-s and leakage currents are 0.6, 0.1, and 0.02 pA/$\mu\textrm{m}$, respectively. Low threshold voltage and subthreshold slope, and good ON-OFF ratio are shown, as well. Thus, the poly-Si TFT’s used by SPC are expected to be applied on TFT-LCD with large-size and high density, which can integrate display panel and peripheral circuit on a large glass substrate.

  • PDF

A Study on Integrated Control and Safety Management Systems for LNG Membrane Storage Tank (멤브레인식 LNG 저장탱크용 통합제어안전관리시스템에 대한 연구)

  • Kim, Chung-Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.2
    • /
    • pp.40-46
    • /
    • 2010
  • In this study, the integrated control and safety management system for a super-large LNG membrane storage tank has been presented based on the investigation and analysis of measuring equipments and safety analysis system for a conventional LNG membrane storage tank. The integrated control and safety management system, which may increase a safety and efficiency of a super-large LNG membrane storage tank, added additional pressure gauges and new displacement/force sensors at the steel anchor between an inner tank and a prestressed concrete structure. The displacement and force sensors may provide clues of a membrane panel failure and a LNG leakage from the inner tank. The conventional leak sensor may not provide proper information on the membrane panel fracture even though LNG is leaked until the leak detector, which is placed at the insulation area behind an inner tank, send a warning signal. Thus, the new integrated control and safety management system is to collect and analyze the temperature, pressure, displacement, force and LNG density, which are related to the tank system safety and leakage control from the inner tank. The digital data are also measured from measurement systems such as displacement and force of a membrane panel safety, LNG level and density, cool-down process, leakage, and pressure controls.