• Title/Summary/Keyword: large source

Search Result 2,516, Processing Time 0.031 seconds

Dose Computation Modeling for Frustum Typed Ir-192 of Ralstron Source (Ralstron 선원대체형 Ir-192 원추선원의 선량 전산화 모델링)

  • 최태진
    • Progress in Medical Physics
    • /
    • v.12 no.1
    • /
    • pp.19-29
    • /
    • 2001
  • In dose modeling, the shape of actual source and sealed capsule are important parameter to determine the physical dose computation. The author investigated the effect of filter of source self-absorption and sealed capsule to designed the high dose rate Ir-192 source for Ralstron(Japan) unit. The size of source designed to 1.5 mm $\Phi$ x 1.5mm length of actual source sealed with stainless steel which is 3.0mm $\Phi$ x 12.0mm length connected to driving cable. The dose attenuation was derived 66.3 % from 2655 segmented source at reference point of 10mm lateral distance of source. The output dose rate factor in tissue for designed source showed 0.0013511 cGy/mCi-sec in reference point at 1cm lateral distance of source center. The dose distribution at inferior of source showed the 52% of that of source tip region, however, the filtering effect was small as 4% at 45degrees of source axis. The dose attenuation within 20 degrees of source axis at near source-cable connector showed large filtering effect as 40% over, but the small effect was revealed isotropic dose distribution at large angle.

  • PDF

Contention-based Reservation Protocol Using a Counter for Detecting a Source Conflict in WDM Single-hop Optical Network with Non-equivalent Distance

  • Sakuta, Makoto;Nishino, Yoshiyuki;Sasase, Iwao
    • Journal of Communications and Networks
    • /
    • v.3 no.4
    • /
    • pp.365-373
    • /
    • 2001
  • We propose a new channel reservation protocol which can reduce message delay by using a counter for detection of d source conflict in a WDM single-hop network with non-equivalent propagation delay. A source convict occurs when a source node has the right to transmit more than or equal to two messages simultaneously, which are transmitted using different wavelengths. In such a case, the source node has to newly obtain the right to transmit the message. In the proposed protocol, by using a source conflict counter a source node can detect a source conflict before a wave-length assignment is performed. Therefore, the source node can start a procedure to newly obtain the right to transmit the message which cannot be transmitted due to a source conflict. We analyse the throughput performance by taking the effect of a source conflict into account, and show that the approximate analysis and the computer simulated results are close. Also, from computer simulated results, we show that our proposed protocol can reduce mean message delay dramatically without degrading throughput performance as the offered load becomes large.

  • PDF

Source Identification of Gaseous Mercury Measured in New York State Using Hybrid Receptor Modeling (수용원 모델을 사용한 대기 중 수은 오염원의 위치 추정에 대한 연구)

  • Han Young-Ji
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.2
    • /
    • pp.179-189
    • /
    • 2006
  • Ambient gas phase mercury concentrations including elemental mercury ($Hg^0$) were measured at the Potsdam, Stockton, and Sterling sites in NY from 2000 to 2003. Also, concentrations of ambient reactive gaseous mercury (RGM; $Hg^{2+}$) were measured at the Potsdam site during one year. The contribution of RGM($4.2{\pm}6.4pg/m^3$) was about $0.2{\sim}3%$ of the total gas phase mercury concentration measured (TGM: $1.84{\pm}1.24,\;1.83{\pm}0.32,\;3.02{\pm}2.14ng/m^3$ in Potsdam. Stockton, and Sterling, respectively) at the receptor sites. Potential Source Contribution Function (PSCF), a hybrid receptor modeling incorporating backward trajectories was performed to identify source areas of TGM. Using PSCF, southern New York, North Carolina, and eastern Massachusetts were identified as important source areas in the United States, while the copper smelters and waste incinerators located in eastern Quebec and Ontario were determined to be significant sources in Canada. The Atlantic Ocean was suggested to be a possible mercury source. PSCF incorporating back-dispersion and deposition was applied for RGM , as well as PSCF based on 2-days back-trajectories. Two different approaches yielded considerably different results, primarily due to the consideration of dispersion rather than deposition. Using back-trajectory based PSCF, eastern Ohio, southern New York, and southern Pennsylvania where large coal -fired power plants area located were identified as the large sources in US. Metallurgical industry located in eastern Quebec was resolved as well. From the result of back-dispersion and deposition based PSCF, Pennsylvania, mining facilities around Lake Superior, Toronto, Boston, MA, Quebec, and coal power plants in NY were identified to be the significant source areas for Potsdam site.

Comparative Analysis of Energy Performance of Hydrothermal, Geothermal Source and Hybrid Heat Pump System According to Internal Heat Load for Office, School and Smart Farm (건축물 용도별 내부 발열부하에 따른 수열원, 지열원 및 하이브리드 히트펌프 시스템의 에너지 성능 비교 분석)

  • Park, Sihun;Min, Joonki
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.18 no.3
    • /
    • pp.19-30
    • /
    • 2022
  • In this study, comparative analysis of energy performance in Taebaek city, a test area, by applying hydrothermal, geothermal source and hybrid heat pump system to office, school and smart farms with different internal heat loads. The conclusion is as follows. In the load characteristics by use of buildings, it was found that office had a large cooling load compared to heating load, school had a large heating load compared to cooling load, and smart farm had only cooling load year-round. Performance analysis of the heat pump system in office shows that the cooling COP of the hydrothermal source is 5.12% and the heating COP is 3.22% lower based on the geothermal source, the cooling COP of the hybrid is 0.41% higher, and the heating COP is the difference in performance appeared sparsely. The performance analysis of the heat pump system in school showed that the cooling COP of the hydrothermal source was 10.44% and the heating COP 3.22% lower based on the geothermal source, and the performance difference between the hybrid cooling and heating COP was insignificant. Heat pump system performance analysis in smart farm only occurred with cooling load. Based on geothermal sources, the cooling COP of the hydrothermal source was 46% and the cooling COP of the hybrid was 19.65%, respectively.

Single-phase SRM Drive for Torque Ripple Reduction and Power Factor Improvement (토크리플 억제와 역률개선을 위한 단상 SRM의 구동시스템)

  • Ahn Jin-Woo;Liang Jianing
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.8
    • /
    • pp.389-395
    • /
    • 2006
  • In the single-phase switched reluctance motor (SRM) drive, the required DC source is generally supplied by the circuit consisting of bridge rectifier with diodes and many filter capacitances connected with AC source. Although the peak torque ripple of SRM is small because of large capacity of the capacitance, the charge and discharge time swhich the AC source acts on the capacitance are small and the peak current will pass on the side of source, so power factor and system efficiency decrease. Therefore a novel SRM drive system is presented in this paper, which includes drive circuit realizing reduction of torque ripple and improvement of power factor and switching topology. The proposed drive circuit consists of one switching part and diodes which can separate the output of AC/DC rectifier from the large capacitance and supply power to SRM alternately in order to realize reduction of torque ripple and improvement of power factor through the turn on and turn off of switching part. In addition, the validity of method is tested by simulation and experiment.

Acoustic emission localization in concrete using a wireless air-coupled monitoring system

  • Yunshan Bai;Yuanxue Liu;Guangjian Gao;Shuang Su
    • Smart Structures and Systems
    • /
    • v.32 no.4
    • /
    • pp.195-205
    • /
    • 2023
  • The contact acoustic emission (AE) monitoring system is time-consuming and costly for monitoring concrete structures in large scope, in addition, the great difference in acoustic impedance between air and concrete makes the detection process inconvenient. In this work, we broaden the conventional AE source localization method for concrete to the non-contact (air-coupled) micro-electromechanical system (MEMS) microphones array, which collects the energy-rich leaky Rayleigh waves, instead of the relatively weak P-wave. Finite element method was used for the numerical simulations, it is shown that the propagation velocity of leaky Rayleigh waves traveling along the air-concrete interface agrees with the corresponding theoretical properties of Lamb wave modes in an infinite concrete slab. This structures the basis for implementing a non-contact AE source location approach. Based on the experience gained from numerical studies, experimental studies on the proposed air-coupled AE source location in concrete slabs are carried out. Finally, it is shown that the locating map of AE source can be determined using the proposed system, and the accuracy is sufficient for most field monitoring applications on large plate-like concrete structures, such as tunnel lining and bridge deck.

Belt Source and In-Line Manufacturing Equipment for Very Large-Size AMOLED

  • Hwang, Chang-Hun;Kim, Y.K.;Shin, Kee-Hyun;Ju, Sung-Hoo;Kwon, Jang-Hyuk
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.651-654
    • /
    • 2006
  • The inline manufacturing equipment using a combination of the belt source and LPS source which is innovatively designed is introduced for the largesize AMOLED. The features of the inline system include 60sec TACT time, 19 numbers of chambers, non-substrate bending and easy application to very thin TFT substrates for the $4^{th}$ - $8^{th}$ Generation AMOLEDs.

  • PDF

Doping control of Belt Source Evaporation Techniques for Large Size AMOLED

  • Hwang, Chang-Hun
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.930-932
    • /
    • 2007
  • In order to understand the doping control for the belt source evaporation, the Alq3 and NPB were codeposited on the Ta plate to re-sublimate. The very slow heating $(0.1^{\circ}C/s)$ of the Ta plate shows the separated rate signals of Alq3 and NPB sublimated from the Alq3-mixed NPB organic film on Ta plate. The ratio of the vapor rates of Alq3 and NPB was measured as same as that of each sublimation rates. Therefore, the doping control of the belt source evaporation is of the ratio of the vaporization rates of host and dopants.

  • PDF

Thermal Performance Analysis of Circular Source for OLED Vapor Deposition (OLED 증착용 서큘러소스의 열적성능 해석)

  • Joo, Young-Cheol;Han, Choong-Hwan;Um, Tai-Joon;Lee, Sang-Wook;Kim, Kug-Weon
    • Journal of the Semiconductor & Display Technology
    • /
    • v.6 no.4
    • /
    • pp.39-42
    • /
    • 2007
  • Temperature distribution of the circular heat source was studied by analyzing the heat transfer of the environment of the circular source for OLED. Circular nozzle source was used to fabricate thin organic layer as the organic material in it was heated, vaporized and deposited to the large size panel. A modified heater structure of circular source has been suggested. The results of numerical analysis shows that the modified heater structure can use 15% more powder in a batch than the original heater structure does. Moreover, the modified heater structure can improve the uniformity of organic vapor deposition by controlling the temperature.

  • PDF

Improved Dual-Path Energy Recovery Circuit using a Current Source and a Voltage Source for High Resolution and Large-Sized Plasma Display Panel

  • Yi, Kang-Hyun;Moon, Gun-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.544-546
    • /
    • 2008
  • An improved dual-path energy recovery circuit (ERC) using a current source and a voltage source for plasma display panel (PDP) is proposed. The proposed ERC uses the voltage source to charge a panel and the current source to discharge the panel. Thus, the proposed circuit can make the panel charge to $V_S$ and discharge to 0V, fully and it is possible to achieve zero voltage switching (ZVS) of all switches in H-bridge inverter and zero current switching (ZCS) of all switches in the ERC. Moreover, it has less conduction and switching loss in ERC devices by the dual energy recovery paths for charging and discharging the panel. Furthermore, it has features of canceling the gas discharge current, high performance and the low cost ERC components. The operation principle and features of the proposed ERC are presented in detail and verified with 42-inch SD PDP.

  • PDF