• 제목/요약/키워드: knife edge method

검색결과 37건 처리시간 0.022초

쥐 전체 뇌의 단면 이미지에서 뇌혈관의 구조 재현 및 정량적 측정 기법에 관한 연구 (A Study on the Reconstruction and Quantitative Measurement Method of Cerebrovascular Structure in Cross-sectioned Images of the Whole Mouse Brain)

  • 이준석
    • 한국멀티미디어학회논문지
    • /
    • 제22권9호
    • /
    • pp.1020-1028
    • /
    • 2019
  • Cerebrovascular disease is a common disease in the elderly population. However, we do not have enough understanding of brain-related diseases. Recent advances in microscopy technology have resulted in the acquisition of vast amounts of image data sets for small organs, and it has become possible to handle vast amounts of image data sets due to improved computer performance and software technology. In this paper, the author proposes introduce a method for classifying and analysing only cerebrovascular information in the mouse brain image, as well as a quantitative measure of the portion of the cerebrovascular in the mouse brain. The study of the cerebrovascular structure is significant, and it can be helpful to improve the understanding of cerebrovasculature. As a result, the author expects that this study will be useful for neuroscientists conducting clinical research.

Half mJ Supercontinuum Generation in a Telecommunication Multimode Fiber by a Q-switched Tm, Ho:YVO4 Laser

  • Zhou, Renlai;Ren, Jiancun;Lou, Shuli;Ju, Youlun;Wang, Yuezhu
    • Journal of the Optical Society of Korea
    • /
    • 제19권1호
    • /
    • pp.7-12
    • /
    • 2015
  • Up to ${\sim}520{\mu}J$ broadband mid-infrared (IR) supercontinuum (SC) generation in telecommunication multimode fiber (MMF) directly pumped by a $2.054{\mu}m$ nanosecond Q-switched Tm, $Ho:YVO_4$ laser is demonstrated. An average output power of 3.64 W is obtained in the band of ~1900 to ~2600 nm, and the corresponding optic-to-optic conversion efficiency is 67% by considering the coupling efficiency. The spectrum has extremely high flatness with negligible intensity variation (<2%) in the wavelength interval of ~2070 to ~2475 nm. The SC long-wavelength edge is limited by the silicon glass material loss, and by optimizing the MMF length, the SC spectrum could extend out to ${\sim}2.6{\mu}m$. The output SC pulse shapes are measured at different output powers, and no splits are found. The SC laser beam is nearly diffraction limited with an $M^2=1.15$ in $2.1{\mu}m$ measured by the traveling knife-edge method, and the laser beam spot is monitored by an infrared vidicon camera.

유한요소법을 이용한 비귀금속-도재관 변연부 형태에 따른 응력 분포 분석 (Finite Element Analysis on Stress Distribution in Base Metal-Ceramic Crown Margin Designs)

  • 이명곤;신정욱;김명덕
    • 대한치과기공학회지
    • /
    • 제22권1호
    • /
    • pp.79-88
    • /
    • 2000
  • The objective of this finite element method study was to analyze the stress distribution induced in a maxillary central incisor Ni-Cr base metal coping ceramic crowns with various margin design. Margin designs of crown in this experiment were knife-edge metal margin on chamfer finishing line of tooth preparation(M1), butt metal margin on shoulder finishing line(M2), reinforced butt metal margin on shoulder finishing line(M3), beveled metal margin on bevelde shoulder finishing line(M4). Two- dimensional finite element models of crown designs were subjected to a simulated biting force of 100N which was forced over porcelain near the lingual incisal edge. Base on plane stress analysis, the maxium von Miss stresses(Mpa) in porcelain venner was 0.432, in metal coping was 0.579, in dentin abutment was 0.324 for M1 model, and M2 model revealed in porcelain was 0.556, in metal coping was 0.511, in dentin was 0.339, and M3 model revealed in porcelain was 0.556, in metal coping was 0.794, in dentin was 0.383 for M4 model. All values of each material in metal-ceramic crown were much below the critical failure values.

  • PDF

AQuaKET 개괄 - 초대구경 나노정밀도 광학측정법 (AQuaKET Overview - A Nano-Accuracy Testing Method for Very Large Optics)

  • 김영수
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2002년도 하계학술발표회
    • /
    • pp.24-25
    • /
    • 2002
  • 밀레니움을 전후하여 세계적으로 8m급 초대형 망원경들이 만들어지고 있다. ESO (European Southern Observatory)의 VLT (Very Large Telescopes) 4기, 미국 영국 카나다 등의 연합 Gemini telescope 2기, 일본의 Subaru 1기 등, 10여기의 망원경들이 완성되었고, 차세대 망원경들이 50m급으로 디자인되고 있다. 우주망원경도 지름 2.4m인 허블 우주망원경(Nubble Space Telescope)의 뒤를 이어 6m급의 차세대 우주망원경 (Next Generation Space Telescope)이 개발되고 있어서 2010년경에 발사될 예정이다. (중략)

  • PDF

Optical Error Analyses in AQuaKET - Intensity variation, Diffraction, and Parallax

  • Kim, Young-Soo
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 2003년도 한국우주과학회보 제12권2호
    • /
    • pp.27-27
    • /
    • 2003
  • The Automated Quantitative Knife-Edge Test (AQuaKET) method was developed for testing the surface profiles of large optics with high accuracy. Testing with the required accuracy of very large telescope is not an easy job to achieve, as it is a nano-technology. There are lots of possible error sources which can occur during the measurements and in the data processing of the AQuaKET. The error sources can be categorized into 5 areas: optics, mechanics, electronics, numerical processes, and system. In this paper, possible error sources in Optics are discussed, which are intensity variation of the light source, diffraction effects, and parallax effect. In this talk, those possible error sources in optics are presented and discussed.

  • PDF

LVDT 센서를 이용한 외경 측정 방안에 대한 연구 (A Study on the out-diameter measuring machine by the LVDT sensors)

  • 황정호;노지훈;박기홍
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.291-292
    • /
    • 2006
  • Currently A demand of high precision workpiece is increasing in industry. At present, roundness measuring machine using Air bearing, coordinate measuring machine that are used from measurement station. but these machines will not be able to apply to In-line process. because of like these machine's price are very expensive and measurement time is long. also, the complexity of conventional roundness measurement method based on fourier transform, it makes difficult to development analysis program. This work present new architecture of a Out-diameter measuring system fur analysis of roundness of product. In this system, the influence of table motion errors is minimize by using two LVDT sensor and knife edge contact tip. We are produce a test machine and make an experimenter on Out-diameter of test bearing. The measurement result compared with roundness measuring machine.

  • PDF

구형렌즈를 사용한 초소형 광 스위치에서의 Simulation (The Simulation of Micro Optical Cross Connect Based On Ball Lens)

  • 이두원;김호성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.594-596
    • /
    • 2000
  • The best simulation condition for the fiber collimator that uses ball lenses was investigated. This kind of fiber collimator can be used in a Micro-Optical-Cross-Connects(MOXC). MOXC is composed of collimating ball lenses, micro mirrors and single-mode fibers. In order to design a MOXC, it is very important to calculate beam path, beam radius, divergence angle that determines the insertion loss of the MOXC. Since the beam profile from the fiber facet is not exact Gaussian profile, it was found that the simulation condition in which beam waist exists on the fiber facet, ignoring Numerical Aperture(NA), gives best agreement with the experimental results. Beam radii were measured with conventional knife edge method.

  • PDF

Spatial Characterization of MAC, a High-Resolution Optical Earth Observation Camera for Small Satellites

  • Kim Eugene D.;Choi Young-Wan;Yang Ho-Soon;Ismail Mohd. Afiq bin
    • Journal of the Optical Society of Korea
    • /
    • 제9권2호
    • /
    • pp.79-83
    • /
    • 2005
  • Spatial calibrations have been performed on the Medium-sized Aperture Camera (MAC) of the RazakSAT satellite. Topics discussed in this paper include the measurements of system modulation transfer function (MTF), relative pixel line-of-sight (LOS), and end-to-end imaging tests. The MTF measurements were made by capturing the scanned knife-edge image on a pixel, and an issue in the MTF calculation algorithm is discussed. The method used to place the focal plane at the correct focal position is described, since they make use of MTF measurements. Relative LOS measurements are done by theodolite measurements of the telescope. Qualitative ground test result of end-to-end imaging is given.

Dichromated Gelatin 박막을 이용한 홀로그래픽 Zone Plate 제작 및 해석 (Fabrication of holographic zone plate using dichromated gelatin hologram)

  • 임용석;이영락;곽종훈;최옥식
    • 한국광학회지
    • /
    • 제8권1호
    • /
    • pp.19-25
    • /
    • 1997
  • Agfa 8E75HD 사진건판에서 얻은 dichromated gelatin(DCG) 박막에 구면파와 평면파를 간섭시켜 holographic zone plate(HZP)를 만들었다. DCG박막의 비서형적인 광학특성들을 고려하여 HZP의 이론식을 유도하였다. 이 이론식에 의한 HZP의 초점거리를 거리는 f. f/2, f/3, f/4, ... 였으며, 실험적으로도 평면파를 입사하여 6개까지의 해당 초점들을 관측하였다. 칼날 주사 방법으로 측정한 첫 번째 재생 초점 근처에서의 빔의 모양은 Gaussian 분포를 가짐을 확인하였다.

  • PDF

영상처리 기법을 이용한 판화 스타일 효과 (Printmaking Style Effect using Image Processing Techniques)

  • 김승완;권오봉
    • 한국콘텐츠학회논문지
    • /
    • 제10권4호
    • /
    • pp.76-83
    • /
    • 2010
  • 본 논문에서는 입력된 실제 영상을 판화와 같은 느낌이 나는 영상으로 변환하는 기법을 제안한다. 즉 이 기법은 입력된 영상을 영상처리 기법을 이용하여 사람이 작업한 것과 같은 고무 판화 느낌이 나는 영상으로 변환한다. 먼저 원본 영상에서 윤곽선을 검출한 후 반전시키고, 잡음 성분의 선이나 점들을 제거하고, 선명화 처리를 하여 첫 번째 영상을 만든다. 다음, 첫 번째 영상과 유사한 방법으로 두 번째 영상을 만든 후, 마지막으로 논리곱을 이용하여 이 두 영상을 합성한다. 이와 같이 처리하여 고무판과 조각칼이 함께 만드는 효과를 표현한다. 또한, 외곽선 검출의 이중 적용이 선폭을 강화하고 잡음 성분의 미세 선을 제거 하는데 효과적임을 보인다.