Optimal Conditions for Defect Analysis Using Electron Channeling Contrast Imaging

  • Oh, Jin-Su;Yang, Cheol-Woong
    • Applied Microscopy
    • /
    • v.46 no.3
    • /
    • pp.164-166
    • /
    • 2016
  • Electron channeling contrast imaging (ECCI) is a powerful analyzing tool for identifying lattice defects like dislocations and twin boundaries. By using diffraction-based scanning electron microscopy technique, it enables microstructure analysis, which is comparable to that obtained by transmission electron microscopy that is mostly used in defect analysis. In this report, the optimal conditions for investigating crystal defects are suggested. We could obtain the best ECCI images when both acceleration voltage and probe current are high (30 kV and 20 nA). Also, shortening the working distance (6 mm) enhances the quality of defect imaging.

Performance Measurement of Siemens Inveon PET Scanner for Small Animal Imaging (소동물 영상을 위한 Siemens Inveon PET 스캐너의 성능평가)

  • Yu, A-Ram;Kim, Jin-Su;Kim, Kyeong-Min;Lee, Young-Sub;Kim, Jong-Guk;Woo, Sang-Keun;Park, Ji-Ae;Kim, Hee-Joung;Cheon, Gi-Jeong
    • Progress in Medical Physics
    • /
    • v.21 no.2
    • /
    • pp.145-152
    • /
    • 2010
  • Inveon PET is a recently developed preclinical PET system for small animal. This study was conducted to measure the performance of Inveon PET as recommended by the NEMA NU 4-2008. We measured the spatial resolution, the sensitivity, the scatter fraction and the NECR using a F-18 source. A 3.432 ns coincidence window was used. A $1\;mm^3$ sized F-18 point source was used for the measurement of spatial resolution within an energy window of 350~625 keV. PET acquisition was performed to obtain the spatial resolution from the center to the 5 cm offset toward the edge of the transverse FOV. Sensitivity, scatter fraction, and NECR were measured within an energy window of 350~750 keV. For measuring the sensitivity, a F-18 line source (length: 12.7 cm) was used with concentric 5 aluminum tubes. For the acquisition of the scatter fraction and the NECR, two NEMA scatter phantoms (rat: 50 mm in diameter, 150 mm in length; mouse: 25 mm in diameter, 70 mm in length) were used and the data for 14 half-lives (25.6 hr) was obtained using the F-18 line source (rat: 316 MBq, mouse: 206 MBq). The spatial resolution of the F-18 point source was 1.53, 1.50 and 2.33 mm in the radial, tangential and axial directions, respectively. The volumetric resolution was $5.43\;mm^3$ in the center. The absolute sensitivity was 6.61%. The peak NECR was 486 kcps @121 MBq (rat phantom), and 1056 kcps @128 MBq (mouse phantom). The values of the scatter fraction were 20.59% and 7.93% in the rat and mouse phantoms, respectively. The performances of the Inveon animal PET scanner were measured in this study. This scanner will be useful for animal imaging.

Sex Differences in Cerebellar Structure of Healthy Adults (정상 성인에서 남녀의 소뇌 구조 차이)

  • Kim, Ji-Hyun H.;Bae, Su-Jin;Ryu, Keun-Taik;Kang, Min-Seong;Lim, Soo-Mee;Lee, Sun-Ho;Lee, So-Jin;Ko, Eun;Jeong, Do-Un
    • Korean Journal of Biological Psychiatry
    • /
    • v.19 no.2
    • /
    • pp.77-83
    • /
    • 2012
  • Objectives : Although there have been studies that examine sex differences of the brain structures using magnetic resonance imaging, studies that specifically investigate cerebellar structural differences between men and women are scarce. The purpose of current study was to examine sex differences in structures of the cerebellum using cerebellar template and cerebellum analysis methods. Methods : Sixteen men and twenty women were included in the study. A MATLAB based program (MathWorks, Natick, MA, USA), Statistical Parametric Mapping 5 (SPM5) using the spatially unbiased infra-tentorial atlas template (SUIT) as the cerebellum template, was used to analyze the brain imaging data. Results : There was no significant difference in age between men (mean age=28.1) and women (mean age=27.2). Men showed higher gray matter density than women in two left cerebellar areas including the clusters in the lobules IV and V (a cluster located across the lobules IV and V), and the lobule VIIIb (lobules IV and V, t=4.75, p<0.001 ; lobule VIIIb, t=3.08, p=0.004). Conclusions : The current study found differences in cerebellar gray matter density between men and women. The current study holds its significance for applying the template specifically developed for the analysis of cerebellum.

Synchrotron Radiation Imaging of Breast Tissue Using a Phase-contrast Hard X-ray Microscope (경 엑스선 위상차 현미경을 이용한 유방 조직의 방사광 영상)

  • Jeong, Young-Ju;Bong, Jin-Gu;Park, Sung-Hwan
    • Progress in Medical Physics
    • /
    • v.22 no.3
    • /
    • pp.117-123
    • /
    • 2011
  • Synchrotron radiation (SR) imaging enables us to observe internal structures of biologic samples without staining. In this study, we obtained X-ray microscopic images of human breast tissues with 11.1 KeV hard X-ray microscope of the Pohang light source and used zone plates and phase-contrast technique to get high resolution X-ray images. Hard X-ray microscopic images of fibrocystic change and breast cancer tissues with a spatial resolution of 60 nm were obtained and from these images, we could observe the micro-structures of human breast tissue. Also we analyzed and compared these images, which revealed distinct features of each condition. In conclusion, SR imaging with phase-contrast hard X-ray microscope for medical application, especially in breast disease can give some useful information for clinical research.

A Comparison of Dose in Changed Technique Factor Using X-ray Imaging System (X-선 장치의 기술적 인자의 변화에 따른 선량 비교 평가)

  • Han, Dong-Kyoon;Ko, Shin-Gwan;Seon, Jong-Ryul;Yoon, Seok-Hwan;Jung, Jae-Eun
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.11 no.2
    • /
    • pp.101-107
    • /
    • 2009
  • With the recent development of diagnosis using radiation and increasing demand of the medical treatment, we need to minimize radiation exposure dose. So, This is the method which reduce patient dose by measuring surface dose of radiographic change factor and by comparing theoretical and actual dose, when we take an X-ray which is generally used. By changing the factor of kV, mAs, FSD, whose range is 60 to 120 kV, 20 to 100 mAs, 80 to 180 cm, we compared theoretical surface dose with actual surface dose calculated by the simple calculation program, Bit system, and NDD-M method As a result, when kV and mAs were higher, theoretical surface dose and actual surface dose were more increased. but the higher FSD was, the more decreased surface dose was. According to this, the error were measured about 0.1 to 0.2 mGy in low dose part and about 0.7 to 1.5 mGy in high dose part. Therefore, this shows that theoretical surface dose calculation method is more correct in low dose part than in high dose part. In conclusion, we will have to make constant efforts which can reduce patient and radiographer's exposure dose, studying methods which can predict patient's radiation exposure dose more exactly.

  • PDF

Acquisition of Monochromatic X-ray using Graded Multilayer Mirror (Graded 다층박막거울을 이용한 단색 엑스선 획득)

  • Ryu, Cheolwoo;Choi, Byoungjung;Son, Hyunhwa;Kwon, Youngman;Kim, Byoungwook;Kim, Youngju;Chon, Kwonsu
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.4
    • /
    • pp.205-211
    • /
    • 2015
  • At a recent medical imaging technology, the major issue of X-ray diagnosis in breast cancer is the early detection of breast cancer and low patient's exposure dose. As one of studies to acquire a monochromatic X-ray, Technologies using multilayer mirror had been preceded. However, a uniform multilayer mirror that consists of uniform thin-film thickness can acquire a monochromatic X-ray only in the partial area corresponds to angle of incidence of white X-ray, so there are limits for X-ray imaging technology applications. In this study, we designed laterally graded multilayer mirror(below GML) that reflects same monochromatic X-ray over the entire area of thin-film mirror, which have the the thickness of the linear gradient that correspond to angle of incidence of white X-ray. By using ion-beam sputtering system added the mask control system we fabricated a GML which has size of $100{\times}100mm^2$. The GML is designed to achieve the monochromatic X-ray of 17.5kev energy and has thin-film thickness change from 4.62nm to 6.57nm(3.87nm at center). It reflects the monochromatic X-ray with reflectivity of more than 60 percent, FWHM of below 2.6keV and X-ray beam width of about 3mm. The monochromatic X-ray corresponded to 17.5keV using GML would have wide application in development of mammography system with high contrast and low dose.

Synthesis of 68Ga-labeled gold nanoparticles for tumor targeted positron emission tomography imaging

  • Jeon, Jongho;Choi, Mi Hee
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.1 no.1
    • /
    • pp.46-52
    • /
    • 2015
  • Herein we present the synthesis of $^{68}Ga$-labeled gold nanoparticles for in vivo PET imaging. A novel chelator DTPA-Cys was easily prepared from diethylenetriaminepentaacetic dianhydride in high yield. The ${\alpha}_v{\beta}_3$ integrin receptor targeted gold nanoparticle probe was synthesized by using DTPA-Cys, polyethylene glycol and cRGD peptide. $^{68}Ga$ labeling of cRGD conjugated gold nanoparticle was carried out at $40^{\circ}C$ for 30 min. Observed radiochemical yield was more than 75% as determined by radio-TLC and the probe was purified by centrifugation. In vitro stability test showed that 90% of $^{68}Ga$-labeled gold nanoparticle probe was stable in FBS for 1 h. Those results demonstrated that $^{68}Ga$-labeled gold nanoparticle could be used as a potentially useful probe for specific tumor imaging.

A Novel Imaging System for Removal of Underwater Distortion using Code V

  • Maik, Vivek;Daniel, Stella;Chrispin Jiji, A.
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.6 no.3
    • /
    • pp.141-150
    • /
    • 2017
  • Images obtained from underwater are usually degraded due to the environmental conditions. Some of the typical degradation factors include turbidity and color degradation. These degradations can be attributed to the absorptive and scattering properties of underwater degradation in terms of optical parameters, such as modulation transfer function (MTF), optical transfer function (OTF),point spread function (PSF), and color constancy. In this paper, we use the CODE V optical simulation software to mimic underwater conditions and model the imaging platform, thereby studying various parameters, such as PSF and MTF, and we use the PSF to remove the underwater turbidity. Experimental results show increased performance with the algorithm, compared to other existing methods.

Fabrication Measurement and Evaluation of a Parabolic Mirror with the Diameter of 450 mm(f/2.7) by Autostigmatic Null Lens System (자동무수차점 방식 널 렌즈 광학계를 이용한 직경 450 mm(f/2.7) 포물면경의 제작 및 측정 평가)

  • Lee, Young-Hun;Jo, Jae-Heung;Rim, Cheon-Seog;Lee, Yun-Woo;Yang, Ho-Soon;Lee, Jae-Hyeob;Lee, In-Won
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.2
    • /
    • pp.165-174
    • /
    • 2006
  • The autotstigmatic null lens system is designed and constructed for the fabrication of a parabolic mirror with the diameter of 450 mm(f/2.7). And the measurement reliability is also analyzed theoretically by means of the tolerancing technique using lens design software(CODE V). From this analysis, we can precisely fabricate a parabolic mirror with the large diameter of 450 mm(f/2.7). Meanwhile, in order to confirm the fabrication results by the autostigmatic method, the mirror surface is tested again by an autocollimating method that uses only a plane mirror without any null lens.

A study on automated speed enforcement system algorithm for using image processing (영상처리를 이용한 과속단속 알고리즘 연구)

  • Park, Geon-Yeong;Jeon, Min-ho;Oh, Chang-heon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.833-836
    • /
    • 2013
  • In this paper, we proposed an intelligent surveillance system which can be determined by the overspeed of vehicle which continuously collects by video imaging device. Imaging device to capture images continuously, and filtering errors that occur as a natural, long-distance moving objects by comparing the images collected before and after the images. To measure the size of things, it proves that able to measure speed of the vehicle, depending on the amount of growing pixels using the pixel processing.

  • PDF