• Title/Summary/Keyword: kV image

Search Result 745, Processing Time 0.027 seconds

DEVELOPMENT OF A HIGH SPEED CCD CAMERA SYSTEM FOR THE OBSERVATION OF SOLAR Ha FLARES

  • VERMA V. K.;UDDIN WAHAB;GAUR V. P.
    • Journal of The Korean Astronomical Society
    • /
    • v.29 no.spc1
    • /
    • pp.391-392
    • /
    • 1996
  • We have developed and tested a CCD camera (100 $\times$ 100 pixels) system for observing Ha images of the solar flares with time resolution> 25 msec. The 512 $\times$ 512 pixels image of CCD camera at 2 Mpixels/sec can be recorded at the rate of more than 5 frame/sec while 100 $\times$ 100 pixels area image can be obtained 40 frames/sec. The 100 $\times$ 100 pixels image of CCD camera corresponds to 130 $\times$ 130 arc - $sec^2$ of the solar disk.

  • PDF

Efficient Color Image Segmentation using SOM and Grassfire Algorithm (SOM과 grassfire 기법을 이용한 효율적인 컬러 영상 분할)

  • Hwang, Young-Chul;Cha, Eui-Young
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.08a
    • /
    • pp.142-145
    • /
    • 2008
  • This paper proposes a computationally efficient algorithm for color image segmentation using self-organizing map(SOM) and grassfire algorithm. We reduce a computation time by decreasing the number of input neuron and input data which is used for learning at SOM. First converting input image to CIE $L^*u^*v^*$ color space and run the learning stage with the SOM-input neuron size is three and output neuron structure is 4by4 or 5by5. After learning, compute output value correspondent with input pixel and merge adjacent pixels which have same output value into segment using grassfire algorithm. The experimental results with various images show that proposed method lead to a good segmentation results than others.

  • PDF

Comparison of Knitwear Preferences and Purchase Behavior of University Students by Sex (대학생의 성별에 따른 니트웨어 선호도 및 구매행동 비교)

  • Suh, Seo-Young;Lee, Mi-Sook
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.14 no.1
    • /
    • pp.43-59
    • /
    • 2012
  • The purpose of this study was to compare knitwear design preferences and purchase behaviors of university students by sex. The subjects were 493 university students in Daejeon and Gongju provinces. The research method was a survey and measurement instruments were 16 stimuli which were manipulated of knitwear shape and self-administrated questionnaire (knitwear design preference items, knitwear favorite image items, purchase behavior items and subject' demographic attributions). Data were analyzed by factor analysis, frequency analysis, t-test, Cronbach' ${\alpha}$ using SPSS program. The results of the study were as follows. First, as for pullover designs according to pullover shape factors, male preferred classic design with normal round neck, set-in sleeves and normal length, whereas female preferred various designs with normal round, normal V or deep V neck, set-in sleeves and normal or long length. Second, there was significant difference by sex in knitwear patterns and materials. Male preferred geometric patterns and 100% cotton, whereas female preferred natural patterns and blended cotton. Third, 4 factors were emerged on knitwear favorite images(casual image, modem classic image, active image and characteristic image). Especially, there was significant difference by sex in active image. Male preferred active image, whereas female did not. Fourth, as for knitwear purchases, male considered fitting as important purchase criteria, whereas female considered design or style. Male used department stores for purchasing, whereas female used Bosejeom for independent fashion. Male preferred high quality knitwear to female.

  • PDF

The effects of voltage of x-ray tube on fractal dimension and anisotropy of diagnostic image

  • Baik, Jee-Seon;Lee, Sam-Sun;Park, Kwan-Soo;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.37 no.4
    • /
    • pp.211-215
    • /
    • 2007
  • Purpose: The purpose of this study was to evaluate the effect of the kV on fractal dimension of trabecular bone in digital radiographs. Materials and Methods: 16 bone cores were obtained from patients who had taken partial resection of tibia due to accidents. Each bone core along with an aluminum step wedge was radiographed with an occlusal film at 0.08 sec and with the constant film-focus distance (32 cm). All radiographs were acquired at 60, 75, and 90 kV. A rectangular ROI was drawn at medial part, distal part, and the bone defect area of each bone core image according to each kV. The directional fractal dimension was measured using Fourier Transform spectrum, and the anisotropy was obtained using directional fractal dimension. The values were compared by the repeated measures ANOVA. Results : The fractal dimensions increased along with kV increase (p < 0.05). The anisotropy measurements did not show statistically significant difference according to kV change. The fractal dimensions of the bone defect areas of the bone cores have low values contrast to the non-defect areas of the bone cores. The anisotropy measurements of the bone defect areas were lower than those of the non-defect areas of the bone cores, but not statistically significant. Conclusion: Fractal analysis can notice a difference of a change of voltage of x-ray tube and bone defect or not. And anisotropy of a trabecular bone is coherent even with change of the voltage of x-ray tube or defecting off a part of bone.

  • PDF

Hardware implementation of a CMOS image sensor pixel using complemental signal path (상보형 신호경로 방식의 CMOS 이미지 센서 픽셀의 하드웨어 구현)

  • Jung, Jin-Woo;Kwon, Bo-Min;Kim, Ji-Man;Park, Ju-Hong;Park, Yong-Su;Lee, Je-Won;Song, Han-Jung
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.6
    • /
    • pp.475-484
    • /
    • 2009
  • In this paper, an analysis of the complementary CMOS active pixel and readout circuit is carried out. Complementary pixel structure which is different from conventional 3TR APS structure consists of photo diode, reset PMOS, several NMOSs and PMOSs sets for complementary signals. Proposed CMOS image sensors pixel has been fabricated using 0.5 standard CMOS process. Measured results show that the output signal range is from 0.8 V to 3.8 V. This output signal range increased 125 % compared to conventional 3TR pixel in the condition of 5 V power supply.

Design and Evaluation of a CMOS Image Sensor with Dual-CDS and Column-parallel SS-ADCs

  • Um, Bu-Yong;Kim, Jong-Ryul;Kim, Sang-Hoon;Lee, Jae-Hoon;Cheon, Jimin;Choi, Jaehyuk;Chun, Jung-Hoon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.17 no.1
    • /
    • pp.110-119
    • /
    • 2017
  • This paper describes a CMOS image sensor (CIS) with dual correlated double sampling (CDS) and column-parallel analog-to-digital converter (ADC) and its measurement method using a field-programmable gate array (FPGA) integrated module. The CIS is composed of a $320{\times}240$ pixel array with $3.2{\mu}m{\times}3.2{\mu}m$ pixels and column-parallel 10-bit single-slope ADCs. It is fabricated in a $0.11-{\mu}m$ CIS process, and consumes 49.2 mW from 1.5 V and 3.3 V power supplies while operating at 6.25 MHz. The measured dynamic range is 53.72 dB, and the total and column fixed pattern noise in a dark condition are 0.10% and 0.029%. The maximum integral nonlinearity and the differential nonlinearity of the ADC are +1.15 / -1.74 LSB and +0.63 / -0.56 LSB, respectively.

Design of a CMOS Image Sensor Based on a Low Power Single-Slope ADC (저전력 Single-Slope ADC를 사용한 CMOS 이미지 센서의 설계)

  • Kwon, Hyuk-Bin;Kim, Dae-Yun;Song, Min-Kyu
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.48 no.2
    • /
    • pp.20-27
    • /
    • 2011
  • A CMOS Image Sensor(CIS) mounted on mobile appliances always needs a low power consumption because of the battery life cycle. In this paper, we propose novel power reduction techniques such as a data flip-flop circuit with leakage current elimination, a low power single slope A/D converter with a novel comparator, and etc. Based on 0.13um CMOS process, the chip satisfies QVGA resolution($320{\times}240$ pixels) whose pitch is 2.25um and whose structure is 4-Tr active pixel sensor. From the experimental results, the ADC in the middle of CIS has a 10-b resolution, the operating speed of CIS is 16 frame/s, and the power dissipation is 25mW at 3.3V(Analog)/1.8V(Digital) power supply. When we compare the proposed CIS with conventional ones, the power consumption is reduced approximately by 22% in sleep mode, 20% in operating mode.

Visual Evaluation of Rib Shadow and Lung Marking during High-voltage Chest Radiography (흉부 고관전압 촬영에 있어서의 늑골음영과 폐문리의 시각적 평가)

  • Choi, Kwon-Kyu;Lee, Chang-Yup;Shin, Dong-Sik;Kim, Chang-Nam;Choi, Ki-Young;Huh, Joon
    • Journal of radiological science and technology
    • /
    • v.15 no.1
    • /
    • pp.99-105
    • /
    • 1992
  • Visual evaluation of rib shadow and lung marking during high voltage chest radiography. The Purpose of this study is to improvement of visual discrimination of pulmonary structures on the conventional chest radiogram. The author prepared an artificial lung using an acryl plate, 8 cm in thickness, which is nearly equivalent to human lung, and 0.6 cm thickness of an aluminum plate for an artificial rib, and 0.5 cm of an acryl plate as a pulmonary vessel as well. And they were used as objects for experimental radiograms. This study performed with gradual increasing densities of film bases in the sequences of densities of 0.6, 0.9, 1.1 and 1.3. We made two combinations of images after multiple and regular cuts, with width of 1 cm, of 4 radiograms at the above mentioned densities of film bases. One image consisted of alternative combination of radiograms taken at densities of 0.6 and 1.3, and the other did at 0.9 and 1.1. The latter image provided better visual perception of pulmonary structures than the former. Experimental radiograms were also taken with 60 kV and 120 kV respectively. After careful evaluation and comparison to images taken on varieties of different densities with combinations and kV, the author had a conclusion that it is advisable to use a high kV X-ray which makes rib shadow subtle, for better visual delineation of pulmonary structures behind ribcage, eventhough contrast of pulmonary structures are decreased at high kV radiogram.

  • PDF

Enhancement of the Deformable Image Registration Accuracy Using Image Modification of MV CBCT (Megavoltage Cone-beam CT 영상의 변환을 이용한 변환 영상 정합의 정확도 향상)

  • Kim, Min-Joo;Chang, Ji-Na;Park, So-Hyun;Kim, Tae-Ho;Kang, Young-Nam;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.22 no.1
    • /
    • pp.28-34
    • /
    • 2011
  • To perform the Adaptive Radiation Therapy (ART), a high degree of deformable registration accuracy is essential. The purpose of this study is to identify whether the change of MV CBCT intensity can improve registration accuracy using predefined modification level and filtering process. To obtain modification level, the cheese phantom images was acquired from both kilovoltage CT (kV CT), megavoltage cone-beam CT (MV CBCT). From the cheese phantom images, the modification level of MV CBCT was defined from the relationship between Hounsfield Units (HUs) of kV CT and MV CBCT images. 'Gaussian smoothing filter' was added to reduce the noise of the MV CBCT images. The intensity of MV CBCT image was changed to the intensity of the kV CT image to make the two images have the same intensity range as if they were obtained from the same modality. The demon deformable registration which was efficient and easy to perform the deformable registration was applied. The deformable lung phantom which was intentionally created in the laboratory to imitate the changes of the breathing period was acquired from kV CT and MV CBCT. And then the deformable lung phantom images were applied to the proposed method. As a result of deformable image registration, the similarity of the correlation coefficient was used for a quantitative evaluation of the result was increased by 6.07% in the cheese phantom, and 18% in the deformable lung phantom. For the additional evaluation of the registration of the deformable lung phantom, the centric coordinates of the mark which was inserted into the inner part of the phantom were measured to calculate the vector difference. The vector differences from the result were 2.23, 1.39 mm with/without modification of intensity of MV CBCT images, respectively. In summary, our method has quantitatively improved the accuracy of deformable registration and could be a useful solution to improve the image registration accuracy. A further study was also suggested in this paper.

Implementation of External Memory Expansion Device for Large Image Processing (대규모 영상처리를 위한 외장 메모리 확장장치의 구현)

  • Choi, Yongseok;Lee, Hyejin
    • Journal of Broadcast Engineering
    • /
    • v.23 no.5
    • /
    • pp.606-613
    • /
    • 2018
  • This study is concerned with implementing an external memory expansion device for large-scale image processing. It consists of an external memory adapter card with a PCI(Peripheral Component Interconnect) Express Gen3 x8 interface mounted on a graphics workstation for image processing and an external memory board with external DDR(Dual Data Rate) memory. The connection between the memory adapter card and the external memory board is made through the optical interface. In order to access the external memory, both Programmable I/O and DMA(Direct Memory Access) methods can be used to efficiently transmit and receive image data. We implemented the result of this study using the boards equipped with Altera Stratix V FPGA(Field Programmable Gate Array) and 40G optical transceiver and the test result shows 1.6GB/s bandwidth performance.. It can handle one channel of 4K UHD(Ultra High Density) image. We will continue our study in the future for showing bandwidth of 3GB/s or more.