Jeong, Jaemin;Kim, Eunki;Jeong, Youngeun;Jeong, Seong Mok;Lee, Hae Beom;Kwon, Youngsam
Journal of Veterinary Clinics
/
v.37
no.4
/
pp.169-174
/
2020
The purpose of this study was to establish normal values for the thoracic limb joint reference angles in Shih Tzu dogs and to describe the standardized CT methodology for measuring the joint reference angle of the humerus. Five pairs of thoracic limbs of Shih Tzu dogs were collected for the CT scans in this study. Three blinded observers measured the joint reference angle of the humerus and radius for each dog by using CT scans in the frontal, sagittal, and axial planes. The means (± SDs) for the average of the right and left humeral joint reference angles were as follows: mMPHA, 83.74 ± 3.95°; mLDHA, 85.04 ± 2.57°; mCaPHA, 46.75 ± 2.20°; mCrDHA, 79.47 ± 1.97°; and HTA, 19.16 ± 2.38°. Means (± SD) for the average of right and left of the radial joint reference angles were as follows: aMPRA, 85.04 ± 1.58°; aLDRA, 87.59 ± 1.37°; aCrPRA, 84.60 ± 1.46°; aCdDRA, 84.27 ± 1.79°; and RTA, 20.91 ± 3.00°. The intraclass correlation coefficients (ICCs) of the joint reference angles for the inter- and intraobserver reliability were good to excellent, except those for the mCrHA and HTA were moderate. Our results suggest that the method of measuring joint reference angles of other long bones by using CT can be applied to thoracic limbs and can extract valid values for one specific breed.
The Transactions of The Korean Institute of Electrical Engineers
/
v.58
no.1
/
pp.203-209
/
2009
The purpose of this study is to develop a minimally constraint joint angle measurement system for the feedback control of FES (functional electrical stimulation) locomotion. Feedback control is desirable for the efficient FES locomotion, however, the simple on-off control schemes are mainly used in clinic because the currently available angle measurement systems are heavily constraint or cosmetically poor. We designed a new angle measurement system consisting of a magnet and magnetic sensors located below and above the ankle joint, respectively, in the rear side of ipsilateral leg. Two magnetic sensors are arranged so that the sensing axes are perpendicular each other. Multiple positions of sensors attachment on the shank part of the ankle joint model and also human ankle joint were selected and the accuracy of the measured angle at each position was investigated. The reference ankle joint angle was measured by potentiometer and motion capture system. The ankle joint angle was determined from the fitting curve of the reference angle and magnetic flux density relationship. The errors of the measured angle were calculated at each sensor position for the ankle range of motion (ROM) $-20{\sim}15$ degrees (dorsiflexion as positive) which covers the ankle ROM of both stroke patients and normal subjects during locomotion. The error was the smallest with the sensor at the position 1 which was the nearest position to the ankle joint. In case of human experiment, the RMS (root mean square) errors were $0.51{\pm}1.78(0.31{\sim}0.64)$ degrees and the maximum errors were $1.19{\pm}0.46(0.68{\sim}1.58)$ degrees. The proposed system is less constraint and cosmetically better than the existing angle measurement system because the wires are not needed.
Journal of the Institute of Convergence Signal Processing
/
v.3
no.1
/
pp.61-66
/
2002
A fuzzy control strategy is described which is utilized to control the joint angle and tip deflection in single flexible manipulator. In this paper, an existing model for a single flexible manipulator is used for the initial development of an FLC. One FLC is designed to govern the joint angle of the manipulator as it is rotated from one position to another, and the second FLC is designed to attenuate the tip deflection which result from joint angle body motion. Reference Trajectory Command is an important method to reduce vibration in flexible beam. This paper presents a very simple command control shaping which eliminates multiple mode residual vibration in a flexible beam combined parallel fuzzy controller. The effectiveness of proposed scheme is demonstrated through computer simulation.
Park, Yang-Su;Kang, Jeng-Ho;Park, Yoon-Myung;Cho, Yong-Gab
제어로봇시스템학회:학술대회논문집
/
2001.10a
/
pp.67.3-67
/
2001
A fuzzy control strategy is described which is utilized to control the joint angle and tip deflection in single flexible manipulator. In this paper, an existing model for a single flexible manipulator is used f3r the initial development of an FLC. One FLC is designed to govern the joint angle of the manipulator as it is rotated from one position to another, and a second FLC is designed to attenuate the tip deflection which result from joint angle body motion. Reference Trajectory Command is an important method to reduce vibration in flexible beam. This paper presents a very simple command control shaping which eliminates multiple mode residual vibration in a flexible beam combined fuzzy controller ...
Human joint motion can be kinematically described in three planes, typically the frontal, sagittal, and transverse, and related to experimentally measured data. The selection of reference systems is a prerequisite for accurate kinematic analysis and resulting development of the equations of motion. Moreover, the development of analysis techniques for the minimization of errors, due to skin movement or body deformation, during experiments involving human locomotion is a critically important step, without which accurate results in this type of experiment are an impossibility. The traditional kinematic analysis method is the Angular-based method (ABM), which utilizes the Euler angle or the Bryant angle. However, this analysis method tends to increase cumulative errors due to skin movement. Therefore, the objective of this study was to propose a new kinematic analysis method, Position-based method (PBM), which directly applies position displacement data to represent locomotion. The PBM presented here was designed to minimize cumulative errors via considerations of angle changes and translational motion between markers occurring due to skin movements. In order to verify the efficacy and accuracy of the developed PBM, the mean value of joint dislocation at the knee during one gait cycle and the pattern of three dimensional translation motion of the tibiofemoral joint at the knee, in both flexion and extension, were accessed via ABM and via new method, PBM, with a Local Reference system (LRS) and Segmental Reference system (SRS), and then the data were compared between the two techniques. Our results indicate that the proposed PBM resulted in improved accuracy in terms of motion analysis, as compared to ABM, with the LRS and SRS.
Kim, Jooho;Heo, Suyoung;Na, Jiyoung;Kim, Namsoo;Kim, Minsu;Jeong, Seongmok;Lee, HaeBeom
Journal of Veterinary Clinics
/
v.33
no.6
/
pp.340-345
/
2016
The present study determined the normal reference ranges for the femoral and tibial joint orientation angles of small-breed dogs. For this purpose, 60 each of cadaveric canine femurs and tibias from normal small-breed dogs (Maltese, Poodle, Shih Tzu, Yorkshire Terrier) were examined with radiographs and photographs. Axial and frontal radiographs and photographs of each bone were obtained, from which anteversion and inclination angles, anatomic lateral proximal and distal femoral angles (aLPFA and aLDFA), mechanical lateral proximal and distal femoral angles (mLPFA and mLDFA), and mechanical medial proximal and distal tibial angles (mMPTA and mMDTA) were measured. The 95% CI for radiographic values of all femurs and tibiae were anteversion angle, $23.4-27.4^{\circ}$; inclination angle, $128.4-130.4^{\circ}$; aLPFA, $117.8-122.1^{\circ}$; aLDFA, $93.7-95.2^{\circ}$; mLPFA $113.8-117.3^{\circ}$; mLDFA $99.2-100.5^{\circ}$; mMPTA $96.8-98.5^{\circ}$; mMDTA $89.4-90.7^{\circ}$. The Maltese had a larger anteversion angle than the Poodle and the Yorkshire Terrier and a larger mLPFA than the Poodle. In the comparison between the radiographs and the photographs, significant differences were found in the anteversion angle, mLPFA, mMPTA, and mMDTA. The established normal reference values might be useful for determining whether a valgus or varus deformity of the femur or the tibia is present and if so, the degree of angular correction needed.
Park, Hong-Lae;Kim, Kyung-Soo;Kim, Lark-Kyo;Nam, Moon-Hyun
Proceedings of the KIEE Conference
/
1989.11a
/
pp.346-350
/
1989
This paper concerned about a study on the position control of KED-1 robot manipulator using PID self-tuning controller. For two joint manipulator KED-1, KED-1 manipulator is translated into kinematics to control each joints in joint space seheme. Angle displacements of joint coordinate are transformed into reference angle velocity of each subsystem through trajectory planning. Also, time sharing technique is used to control KED-1 manipulator. A series of simulation and experiment are performed for each joint in show the valid of proposed algorithm.
Journal of the Korean Society of Physical Medicine
/
v.11
no.2
/
pp.71-76
/
2016
PURPOSE: The purpose of this study was to compare isometric contraction of deltoid middle fiber between elastic band and light dumbbell on various shoulder abduction angle. And this study intends to examine the compare with isometric contraction on deltoid middle fiber in various abduction angle of shoulder joint. METHODS: The participants of this study were Korean healthy adult in their 20s (n=60). The 8 channel surface electromyography was used to measure activity of the deltoid middle fiber at isomeric contraction on various abduction angle: $0^{\circ}$, $30^{\circ}$, $60^{\circ}$, $90^{\circ}$, $120^{\circ}$ of shoulder joint using elastic band: red color Theraband and dumbbell: 2kg. The data used in the analysis of the present study was the root mean square. RESULTS: The deltoid middle fiber activation was not significantly different between elastic band and dumbbell at each abduction angle. The deltoid middle fiber activation significantly increased as more to increased shoulder abduction angle in elastic band and dumbbell. CONCLUSION: The elastic band and dumbbell was to provide the similarly load to the deltoid middle fiber isometric contraction on all of the shoulder abduction angle. The deltoid middle fiber activation increased as more to increased shoulder abduction angle in elastic band and dumbbell. These results may be an important reference in development of exercise on shoulder joint.
The purpose of this study was to investigate steady-state force depression following active muscle shortening in human tibialis anterior muscle during voluntary contractions. Subjects (n = 7; age $24{\sim}39$ years; 7 males) performed isometric reference contractions and isometric-shortening-isometric contractions, using maximal voluntary effort. Force depression was assessed by comparing the steady-state isometric torque produced following active muscle shortening with the purely isometric reference torque obtained at the corresponding joint angle. In order to test for effects of the shortening conditions on the steady-state force depression, the speed of shortening were changed systematically in a random order but balanced design. Ankle dorsiflexion torque and joint angle were continuously measured using a dynamometer. During voluntary contractions, muscle activation of the tibialis anterior and the medical gastrocnemius was recorded using surface electromyography. Force depression during voluntary contractions, with a constant level of muscle activation, was 12 %, on average over all subjects. Force depression was independent of the speeds of shortening ($13.8{\pm}2.9%$, $10.3{\pm}2.6%$ for 15 and 45 deg/sec over 15 deg of shortening, respectively). The results of this study suggest that steady-state force depression is a basic property of voluntarily-contracting human skeletal muscle and has functional implication to human movements.
Journal of the Korea Institute of Information and Communication Engineering
/
v.4
no.1
/
pp.115-121
/
2000
Command shaping is an important method to reduce vibration in flexible beam. This paper presents a very simple command control shaping which eliminates multiple mode residual vibration in a flexible beam in finite time. The command is constructed by solving linear equations. The finite time duration in which the desired motion of joint angle is achieved along with elimination of the residual vibration can be arbitrarily specified. The necessary conditions for using command as a reference input for the joint angle in a closed-loop configuration are also discussed. The effectiveness of Proposed scheme is demonstrated through computer simulation.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.