• Title/Summary/Keyword: jitter measurement

Search Result 77, Processing Time 0.024 seconds

Verification of Micro-vibration Isolation Performance by using Low Rotational Stiffness Isolator under Elevation Direction Operation of the X-band Antenna (저 회전강성 진동 절연기에 의한 X-밴드 안테나의 고각방향 미소진동 절연 효과 검증)

  • Jeon, Su-Hyeon;Lee, Jae-Gyeong;Jeong, Sae-Han-Sol;Lee, Myeong-Jae;Oh, Hyun-Ung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.4
    • /
    • pp.238-246
    • /
    • 2015
  • A stepping motor is widely used to operate the elevation and azimuth stage of the X-band antenna with 2-axis gimbal system for effective image data transmission from a satellite to a ground station. However, such stepping motor also generates an undesirable micro-vibration which is one of the main disturbance sources affecting image quality of the high-resolution observation satellite. In order to improve the image quality, the micro-vibration isolation of the X-band antenna system is essential. In this study, the low rotational stiffness isolator has been proposed to reduce the micro-vibration disturbance induced by elevation direction operation of the X-band antenna. In addition, its structural safety was confirmed by the structure analysis based on the derived torque budget. The effectiveness of the design was also verified through the micro-vibration measurement test.

A V-I Converter Design for Power Variation Insensitivity PLL (전원 전압 변화에 둔감한 PLL을 위한 V-I 변환기 설계)

  • Lee, Hyun-Seok;Hong, Dong-Hee;Park, Jong-Wook;Lim, Shin-Il;Sung, Man-Young
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.3 s.357
    • /
    • pp.59-64
    • /
    • 2007
  • This paper describes the PLL of TCON(Timing Controller) chip for FPD(Flat Panel Display). We propose a new V-I converter which is insensitive to the power supply variation when it is applied to the TCON. The new V-I converter compensated the output frequency of VCO by appling the current that is inversely proportional to the voltage variation. The proposed idea is implemented with a 1-ploy 3-metal 0.25m TSMC CMOS technology and has the output frequency range from 192MHz to 360MHz at the supply voltage of 2.5V. Measurement result shows the RMS jitter of 100ps in the above output frequency range.

A 1.8 V 0.18-μm 1 GHz CMOS Fast-Lock Phase-Locked Loop using a Frequency-to-Digital Converter

  • Lee, Kwang-Hun;Jang, Young-Chan
    • Journal of information and communication convergence engineering
    • /
    • v.10 no.2
    • /
    • pp.187-193
    • /
    • 2012
  • A 1 GHz CMOS fast-lock phase-locked loop (PLL) is proposed to support the quick wake-up time of mobile consumer electronic devices. The proposed fast-lock PLL consists of a conventional charge-pump PLL, a frequency-to-digital converter (FDC) to measure the frequency of the input reference clock, and a digital-to-analog converter (DAC) to generate the initial control voltage of a voltage-controlled oscillator (VCO). The initial control voltage of the VCO is driven toward a reference voltage that is determined by the frequency of the input reference clock in the initial mode. For the speedy measurement of the frequency of the reference clock, an FDC with a parallel architecture is proposed, and its architecture is similar to that of a flash analog-to-digital converter. In addition, the frequency-to-voltage converter used in the FDC is designed simply by utilizing current integrators. The circuits for the proposed fast-lock scheme are disabled in the normal operation mode except in the initial mode to reduce the power consumption. The proposed PLL was fabricated by using a 0.18-${\mu}m$ 1-poly 6-metal complementary metal-oxide semiconductor (CMOS) process with a 1.8 V supply. This PLL multiplies the frequency of the reference clock by 10 and generates the four-phase clock. The simulation results show a reduction of up to 40% in the worstcase PLL lock time over the device operating conditions. The root-mean-square (rms) jitter of the proposed PLL was measured as 2.94 ps at 1 GHz. The area and power consumption of the implemented PLL are $400{\times}450{\mu}m^2$ and 6 mW, respectively.

Analysis of Phonatory Aerodynamic & E.G.G. during Passaggio of the Trained Male Singers (남성성악가의 Vocal Register Transition(Passaggio)시 공기역학적 변화와 EGG의 변화 연구)

  • Nam, Do-Hyun;Choi, Seong-Hee;Choi, Jae-Nam;Choi, Hong-Shik
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.15 no.1
    • /
    • pp.21-26
    • /
    • 2004
  • Vocal Register Transition(Passaggio) is one of the most important vocal technique for classically trined male singers(tenor). Passaggio is that it bridges the chest register to head register without a noticeable voice break. Vocalist gest the feeling that voice is not locked a particular register. The purpose of this study was to clarify the difference between easy($B_3$) tone and non passaggio(F#_4$) & passaggio(F#_4$). We selected 6 trained singers(tenor), who had more than 12.6 years of experience and were well trained in passaggio technique. Simulataneous measurement was performed frequency(F0), mean flow rate(MFR), intensity(I), and subglottal pressure(Psub) using a phonatory function analyzer(Nagashima) and Closed Quotient(CQ), Jitter, Shimmer, NHR a Electro-glottography(EGG) of Lx. Speech Studio(Laryngogrph Lt, London, UK) and vocal efficiency was calculated by Carroll's method. For the tenor, target tone/a/was measured in three conditions : 1) easy phonation : $B_3$, 2) high tone without passaggio : F#_4$, 3) high tone with passaggio : F#_4$). The results revealed that F0 of the target tones between non-passaggio group and passaggio group were not significantly different though higher is F0, higher is subglottal pressure. And also CQ, MFR, Psub were increased in passagio than nonpssagio but these values were not statistically different. This study concluded that passaggio is the vocal technique to make the same quality of tone between chest register and head register in tenor.

  • PDF

Hybrid Monitoring Scheme for End-to-End Performance Enhancement of Real-time Media Transport (실시간 미디어 전송의 종단간 성능 향상을 위한 혼성 모니터링 기법)

  • Park Ju-Won;Kim JongWon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.10B
    • /
    • pp.630-638
    • /
    • 2005
  • As real-time media applications based on IP multicast networks spread widely, the end-to-end QoS (quality of service) provisioning for these applications have become very important. To guarantee the end-to-end QoS of multi-party media applications, it is essential to monitor the time-varying status of both network metrics (i.e., delay, jitter and loss) and system metrics (i.e., CPU and memory utilization). In this paper, targeting the multicast-enabled AG (Access Grid) group collaboration tool based on multi-Party real-time media services, a hybrid monitoring scheme that can monitor the status of both multicast network and node system is investigated. It combines active monitoring and passive monitoring approaches to measure multicast network. The active monitoring measures network-layer metrics (i.e., network condition) with probe packets while the passive monitoring checks application-layer metrics (i.e., user traffic condition by analyzing RTCP packets). In addition, it measures node system metrics from system API. By comparing these hybrid results, we attempt to pinpoint the causes of performance degradation and explore corresponding reactions to improve the end-to-end performance. The experimental results show that the proposed hybrid monitoring can provide useful information to coordinate the performance improvement of multi-party real-time media applications.

Studies on Voice Changes Associated with Alcohol Intake (음주에 따른 음성 변화에 대한 고찰)

  • Kim, Jung-Hyun;Yoon, Je-Hwan;Cho, Hyung-Ho;Cho, Yeon;Cho, Jae-Sik
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.13 no.1
    • /
    • pp.18-22
    • /
    • 2002
  • Background and Objectives : It has been pointed out that alcohol intake in human beings induces changes in voice register and maximum phonation time. These changes supposedly result from injection of the vibratory vocal folds. The purpose of this study was to clarify the voice changes associated with alcohol intake and the changes of laryngeal mucosa. Materials and Methods : The subjects included 29 volunteers, including 20 men and 9 women ranging in age from 22 to 31 years. Alcohol intake was accomplished by oral administration of 23% soju 1 bottle (255cc). Serum alcohol concentration levels were evaluated hourly for 3 h after ingestion of alcohol. Seven measurements were performed at pre-alcohol intake and post-alcohol intake hourly : fundamental frequency, jitter, shimmer, noise to harmonic ratio as the acoustic analysis, maximal phonation time, mean flow rate, and subglottal pressure as the aerodynamic analysis. The changes of laryngeal mucosa were evaluated by flexible laryngoscope at each measurement. Results : By comparing the acoustic and aerodynamic data and laryngeal mucosa before and after alcohol intake, there were not remarkable changes (p>0.05). Conclusion : The voice and laryngeal mucosa have not remarkably changed according to alcohol concentration in this study. Furthermore studies on the voice change induced by multiple alcohol concentrations are required.

  • PDF

Acoustic Analysis of Classically Trained Western Singers (서양 음악을 전공으로 하는 성악인의 음향학적 분석)

  • 정성민
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.10 no.2
    • /
    • pp.124-129
    • /
    • 1999
  • Background and Objectives : Classical singers are capable of masking abnormalities due to their high level of training and may present with apparent technical deficits rather than with obvious dysfunction. Therefore, some variations from expected normal laryngeal behavior may be present in trained classical singers. Consequently it is important for otolaryngologist to obtain a baseline assessment of their laryngeal function. Materials and Methods : Acoustic measurement including strobovideolaryngoscopy from 50 classically trained singers was done for this study, which was compared with the data from 20 untrained adults. Results and Conclusion : This study showed that 50-healthy asymptomatic classical singers revealed an incidence of 50% abnormal strobovideolaryngoscopic findings, but their acoustic data was within normal limit despite the abnormal laryngeal findings. Therefore the author recommends that the classical singers need objective voice analysis and their baseline data should be used for the accurate diagnosis of the cause of voice dysfunction In classical singer whose baseline laryngeal behavior may be unusual.

  • PDF

A "GAP-Model" based Framework for Online VVoIP QoE Measurement

  • Calyam, Prasad;Ekici, Eylem;Lee, Chang-Gun;Haffner, Mark;Howes, Nathan
    • Journal of Communications and Networks
    • /
    • v.9 no.4
    • /
    • pp.446-456
    • /
    • 2007
  • Increased access to broadband networks has led to a fast-growing demand for voice and video over IP(VVoIP) applications such as Internet telephony(VoIP), videoconferencing, and IP television(IPTV). For pro-active troubleshooting of VVoIP performance bottlenecks that manifest to end-users as performance impairments such as video frame freezing and voice dropouts, network operators cannot rely on actual end-users to report their subjective quality of experience(QoE). Hence, automated and objective techniques that provide real-time or online VVoIP QoE estimates are vital. Objective techniques developed to-date estimate VVoIP QoE by performing frame-to-frame peak-signal-to-noise ratio(PSNR) comparisons of the original video sequence and the reconstructed video sequence obtained from the sender-side and receiver-side, respectively. Since processing such video sequences is time consuming and computationally intensive, existing objective techniques cannot provide online VVoIP QoE. In this paper, we present a novel framework that can provide online estimates of VVoIP QoE on network paths without end-user involvement and without requiring any video sequences. The framework features the "GAP-model", which is an offline model of QoE expressed as a function of measurable network factors such as bandwidth, delay, jitter, and loss. Using the GAP-model, our online framework can produce VVoIP QoE estimates in terms of "Good", "Acceptable", or "Poor"(GAP) grades of perceptual quality solely from the online measured network conditions.

Real-time Interactive Control of Magnetic Resonance Imaging System Using High-speed Digital Signal Processors (고속 DSP를 이용한 실시간 자기공명영상시스템 제어)

  • 안창범;김휴정;이흥규
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.40 no.5
    • /
    • pp.341-349
    • /
    • 2003
  • A real time interactive controller (spectrometer) for magnetic resonance imaging (MRI) system has been developed using high speed digital signal processors (DSP). The controller generates radio frequency (rf) waveforms and audio frequency gradient waveforms and controls multiple receivers for data acquisition. By employing DSPs having high computational power (e.g., TMS320C670l) real time generation of complicated gradient waveforms and interactive control of selection planes are possible, which are important features in real-time imaging of moving organs, e.g., cardiac imaging. The spectrometer was successfully implemented at a 1.5 Tesla whole body MRI system for clinical application. Performance of the spectrometer is verified by various experiments including high- speed imaging such as fast spin echo (FSE) and echo planar imaging (EPI). These high-speed imaging techniques reduce measurement time, however, usually intensify artifact if there is any systematic phase error or jitter in the synchronization between the transmitter, receiver, and gradients.

Correlation Analysis Between Vocal Fold Vibration and Voice Signal Analysis Parameter by Water Temperature (수온에 따른 성대 진동과 음성신호 분석 요소간의 상관성 분석)

  • Kim, Bong-Hyun;Cho, Dong-Uk
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.4C
    • /
    • pp.347-353
    • /
    • 2012
  • In this paper, we carried out experiments to analyze influence of vocal cords according to changes of water temperature. We would like to particularly perform a study to design voice measurement system for significant extraction about vibration patterns of vocal cords according to temperature changes of water to drink. To this end, we measured elements value of voice analysis vibration of vocal cords to change, when drank, temperature difference of step 8 from $0^{\circ}C$ to $70^{\circ}C$ to $10^{\circ}C$ intervals. As a result of us experiment, when drank water of $30^{\circ}C{\sim}40^{\circ}C$, vibration of vocal cords stabilized and accuracy of pronunciation improved. We can analyzed that water of $30^{\circ}C{\sim}40^{\circ}C$ had a good effect in vocal cords.