• 제목/요약/키워드: iron oxide scale

검색결과 50건 처리시간 0.026초

Si함유강의 용융아연 도금부착성에 미치는 산화-환원 열처리 영향 (Effect of oxidation-Reduction Hating Conditions on Coating Adherence of Hot-Dip Galvanized Steel Containing silicon)

  • 김종상
    • 한국표면공학회지
    • /
    • 제31권2호
    • /
    • pp.101-108
    • /
    • 1998
  • The effect of oxidation-reduction heating conditions on coating adherence of hot-dip galvanized steel containing silicon has beeninvestigated. The presence of a stbke sillicon oxide formed on the steel surface has been shown to be very detrimenal to proper wetting by liquid zinc. When the steel has more than the critical sillicon content neeled to from a stable external oxide, the use of oxidation-reduction method has been found successful in obtaining a good quality, coated product with excellence adhreence. This can be explained by the formation of an iron oxide. The iron oxrtion of the scale is reduced, leaving the stable oxides dispersed in a fresh metallic iron surface layer. This reduced iron surface is easily wetted by the liquid zinc and excellent adherence is obtained.

  • PDF

HRSG 보일러 튜브 내면 스케일의 특성연구 (A Study on Characteristics of HRSG Boiler Inner Tube Scale)

  • 이승민;민병연;정년호
    • Corrosion Science and Technology
    • /
    • 제11권3호
    • /
    • pp.82-88
    • /
    • 2012
  • The thickness and chemical composition of oxides on heat recovery steam generator tubes of combined cycle power plant were examined in order to evaluate the corrosion of the tubes. Tubes were removed from the plant after actual operations for 21,482, 42,552 and 56,123 hours respectively. Thickness and growth rate of the oxide scale on reheater inner tube (SA213-T22) were very high compared to those other tubes. The oxide scale was about $250{\mu}m$ thick and uniform. The components of the scale were iron oxides. The oxide scale was mixed oxides consisting of magnetite$(Fe_3O_4)$ and hematite$(Fe_2O_3)$. The oxide on inner tube was removed using many kinds of chemicals and it was found that chelating agents were dissolved faster than other chemicals.

TiAl 합금의 고온 산화에 미치는 Fe의 영향 (Effect of Fe on the High Temperature Oxidation of TiAl Alloys)

  • 김미현;이동복
    • 한국표면공학회지
    • /
    • 제33권4호
    • /
    • pp.281-288
    • /
    • 2000
  • To understand the effect of Fe on the oxidation behavior of TiAl alloys, TiAl-(2, 4, 6at% )Fe were oxidized at 800 and 90$0^{\circ}C$ in air. The oxidation resistance of TiAl-Fe alloys increased with increasing an iron content. The scales formed consisted of an outer $TiO_2$ layer, an intermediate $A1_2$$O_3$ layer, and an inner mixed ($TiO_2$+$A1_2$$O_3$) layer, being similar to other common TiAl alloys. But, the scales formed on TiAl-Fe alloys were generally thin compared to those formed on pure TiAl, and contained dissolved iron. Below the oxide scale, an oxygen affected zone was formed. This beneficial effects of Fe on increasing the oxidation resistance and scale adherence of TiAl alloys were attributed to the refinement of oxide grains, increased scale adherence and the enhanced alumina-forming tendency.

  • PDF

산화철계 형석대체제의 전로 정련특성 (BOF Refining of Fluorspar Substitute Using Iron Oxide Based By-product)

  • 금창훈;허보영
    • 한국재료학회지
    • /
    • 제16권5호
    • /
    • pp.336-340
    • /
    • 2006
  • Fluorspar has been essential flux in steelmaking process. The main effects of fluorspar addition are lowering of the viscosity and melting temperature of slag. In recent years, due to the increasing price and environmental problem of fluorspar, various types of fluorspar substitute have been investigated. In this study, iron oxide by-products such as sinter dust, basic oxygen furnace (BOF) sludge and mill scale were developed as a substitute in terms of waste recycling. Several plant trials were carried out by addition of briquetted substitutes of $4{\sim}6$ kg/ton to compare with the fluorspar of $0.7{\sim}1$ kg/ton. The substitutes showed a similar behavior of slag formation, phosphorus removal and MgO saturation content.

Removal of iron oxide scale from boiler feed-water in thermal power plant by high gradient magnetic separation: field experiment

  • Akiyama, Yoko;Li, Suqin;Akiyama, Koshiro;Mori, Tatsuya;Okada, Hidehiko;Hirota, Noriyuki;Yamaji, Tsuyoshi;Matsuura, Hideki;Namba, Seitoku;Sekine, Tomokazu;Mishima, Fumihito;Nishijima, Shigehiro
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제23권3호
    • /
    • pp.14-19
    • /
    • 2021
  • The reduction of carbon dioxide emissions becomes a global issue, the main source of carbon dioxide emissions in the Asian region is the energy conversion sector, especially coal-fired power plants. We are working to develop technologies that will at least limit the increase in carbon dioxide emissions from the thermal power plants as one way to reduce carbon dioxide emissions. Our research aims to reduce carbon dioxide emissions by removing iron oxide scale from the feedwater system of thermal power plants using a superconducting high-gradient magnetic separation (HGMS) system, thereby reducing the loss of power generation efficiency. In this paper, the background of thermal power plants in Asia is outlined, followed by a case study of the introduction of a chemical cleaning line at an actual thermal power plant in Japan, and the possibility of introducing it into the thermal power plants in China based on the results.

단조 산화스케일로부터 철계분말 제조 기술개발 연구 (Study on the Reduction of Forging Oxide Scale using Hydrogen)

  • 이동원;윤중열;신선명;김인수;왕제필
    • 한국분말재료학회지
    • /
    • 제20권3호
    • /
    • pp.174-179
    • /
    • 2013
  • The study on the fabrication of iron powder from forging scales using hydrogen gas has been conducted on the effect of hydrogen partial pressure, temperature, and reactive time. The mechanism for the reduction of iron oxides was proposed with various steps, and it was found that reduction pattern might be different depending on temperature. The iron content in the scale and reduction ratio of oxygen were both increased with increasing reactive time at 0.1atm of hydrogen partial pressure. On the other hand, for over 30 minutes at 0.5 atm of hydrogen partial pressure, the values were found to be almost same. In the long run, iron metallic powder was obtained with over 90% of iron content and an average size of its powder was observed to be about $100{\mu}m$.

전통 제철실험을 통해 생산된 단조박편의 재료과학적 특성 연구 (A Study on the Metallurgical Characteristic of Hammer Scale Produced through Traditional Iron-making Experiments)

  • 조성모;조남철
    • 보존과학회지
    • /
    • 제37권6호
    • /
    • pp.738-747
    • /
    • 2021
  • 제철원료별 직접제련법 복원실험으로 생산된 단조박편의 재료과학적 분석을 통해 금속학적 특성을 규명하였다. 제련을 위해 경주감포사철과 양양철광석을 이용하며, 각각 4개의 그룹을 설정하였다. 분석은 주성분, 광물 동정, 미세조직 관찰을 하였다. 주성분 분석 결과 정련·단접이 진행될수록 Fe의 함량은 증가하고 비금속개재물의 함량은 감소하였다. 광물을 동정한 결과 산화철 계열의 광물이 확인되었다. 미세조직 관찰 결과 Wüstite, Fayalite가 관찰되었으며, 일부에는 응집된 Wüstite가 관찰되었다. 일부 다각형, 장주상의 Magnetite도 확인되었다. 또한, 공극 및 불순물, 비금속개재물은 점차 감소하였다. 차후 다양한 제철원료를 이용한 복원실험을 통해 생산된 단조박편의 재료과학적 분석을 통해 금속학적 특성을 규명하고, 이를 유적에서 출토된 단조박편과 비교·검토하는 것이 필요하다.

Removal of iron scale from feed-water in thermal power plant by magnetic separation - Introduction to chemical cleaning line -

  • Yamamoto, Junya;Mori, Tatsuya;Hiramatsu, Mami;Akiyama, Yoko;Okada, Hidehiko;Hirota, Noriyuki;Matsuura, Hideki;Namba, Seitoku;Sekine, Tomokazu;Mishima, Fumihito;Nishijim, Sigehiro
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제20권2호
    • /
    • pp.6-10
    • /
    • 2018
  • Removal of iron oxide scale from feed-water in thermal power plant can improve power generation efficiency. We have proposed a novel scale removal system utilizing High Gradient Magnetic Separation (HGMS). This system can be applied to high temperature and pressure area. We have conducted the lab-scale model experiments using ${\varphi}50mm$ filters and it demonstrated high removal efficiency in HGMS, but scale-up of the system is required toward practical use. In this study, we conducted a large scale mock-up HGMS experiment. We used the superconducting solenoidal magnet with ${\varphi}400mm$ bore and demonstrated that our HGMS system can achieve sufficient scale removal capacity that is required to introduce into both off-line and on-line system.

Effect of Si on Corrosion of Fe-Cr and Fe-Cr-Ni Alloys in wet CO2 Gas

  • Nguyen, T.D.;Zhang, J.;Young, D.J.
    • Corrosion Science and Technology
    • /
    • 제14권3호
    • /
    • pp.127-131
    • /
    • 2015
  • Model alloys Fe-9Cr, Fe-20Cr and Fe-20Cr-20Ni (wt. %) with 0.1 and 0.2 % Si were exposed to $Ar-20CO_2-20H_2O$ gas at $818^{\circ}C$. The undoped alloys formed a thick iron-rich oxide scale. The additions of Si reduced scaling rates of Fe-9Cr to some extent but significantly suppressed the formation of iron oxide scales on Fe-20Cr and Fe-20Cr-20Ni. Carburisation also occurred in all undoped alloys, but not in Si-containing Fe-20Cr and Fe-20Cr-20Ni. Protection against carburisation was a result of the formation of an inner scale layer of silica.

산화아연(酸化亞鉛)의 탄소열환원반응(炭素熱還元反應)에서 산화철(酸化鐵)의 영향(影響) (Carbothermic Reduction of Zinc Oxide with Iron Oxide)

  • 김병수;박진태;김동식;유재민;이재천
    • 자원리싸이클링
    • /
    • 제15권4호
    • /
    • pp.44-51
    • /
    • 2006
  • 대부분 전기로 분진 처리공정은 전기로 분진으로부터 아연을 회수하기 위하여 전기로 분진에 함유된 산화아연의 환원제로 탄소를 사용한다. 본 연구에서는 산화아연의 탄소열환원반응에 관한 전기로 분진의 주성분 중의 하나인 산화철의 영향에 대하여 속도론적으로 조사되었다. 실험은 반응온도 1173 K-1373 K 범위에서 중량감량법을 이용하여 수행되었다. 실험결과, 적절한 량의 산화철 첨가는 산화아연의 탄소열환원반응 속도를 증진시키는 것으로 나타났다. 이것은 산화철이 산화아연의 탄소열환원반응에서 탄소의 gasification 반응을 촉진시키기 때문으로 관찰되었다. 표면화학반응이 율속인 shrinking core model 1173 - 1373 K 범위에서 고체 탄소에 의한 산화아연의 환원반응 속도 데이터를 분석하는데 유용한 것으로 분석되었다. ZnO-C 반응계에서 활성화 에너지는 224kJ/mol (53 kcal/nol)로, $ZnO-Fe_{2}O_{3}-C$ 반응계에서 활성화 에너지는 175kJ/mol(42kca1/mol)로 그리고 ZnO-밀스케일-C 반응계에서 활성화 에너지는 184 kJ/mol (44 kcal/mol)로 각각 계산되었다.