• Title/Summary/Keyword: ionizer

Search Result 44, Processing Time 0.032 seconds

Characteristics of long-term operated Electrostatic airclean filter for air-conditioner (장시간사용(長時間使用)한 공조용(空調用) 전기집진(電氣集塵)필터의 특성(特性))

  • Hong, Young-Ki;Kang, Kwang-Ok;Lee, Sung-Hwa;Son, Sang-Cheol
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.453-455
    • /
    • 1995
  • In electrostatic airclean filter, the collection efficiency defends on particle charge in the ionizer section. The effect of electrostatic airclean filter condition (deposition of dust, variation of corona discharge current) on corona discharge characteristics was well studied. However, it seems not to be studied on corona discharge characteristics of electrostatic airclean filter respect to contaminated electrode which is caused by practical use. In this paper, Long-term(60days) effects are studied experimentally by two methods. The one is ozone concentration, the other is collection efficiency. Generation of ozone level was increased but collection efficiency was slightly reduced in long-term used electrostatic airclean filter.

  • PDF

Experimental Study on the Discharge Electrode of A Two-Stage Electrostatic Air Cleaner (2단 평행판 전기집진기의 방전부 특성 실험)

  • Kim, I.S.;Lee, J.O.;Kim, Y.J.;Choi, H.O.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.5 no.1
    • /
    • pp.27-34
    • /
    • 1993
  • The two-stage electrostatic air cleaner is a particle control device that uses electrical forces to move particles in the flowing gas stream onto collector plates. Despite a general understanding of electrostatic air cleaner operation and their successful use in industry, many questions regarding flow, electric fields and particle collection have remained unanswered. In this paper, an experimental investigation for designing the discharge electrode, including ionizer wire diameter, plate length and wire-to-plate spacing, is carried out. The electrical conditions, namely the electric field intensity, the space current and the particle charge intensity, in wire-plate electrostatic air cleaner are reported and examined.

  • PDF

A case study of carnation productivity improvement using a ozone-negative ion generator (오존-음이온 발생장치를 이용한 카네이션 생산성 향상 사례 연구)

  • Song, Hyun-Jig;Lee, Sang-Keun;Yoon, Dae-Hee;Park, Won-Zoo;Lee, Kwang-Sik;Choi, Sang-Tae
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.271-273
    • /
    • 2005
  • In order to carnation productivity improvement, ozonizer and negative ionizer has been designed and manufactured. The ozone is generated by DC positive streamer discharge and the negative ion is generated by DC negative discharge. When the ozone and negative ion are supplied growth room and farm to carnation cultivation, the carnation productivity is improved.

  • PDF

Reduction Effect of Various Air Purifiers on Airborne Microorganism for Preventing Air Infected Animal Disease (공기감염성 가축질병 예방을 위한 공기청정기 유형에 따른 부유 미생물의 제거 효과)

  • Park, Chan-Jeong;Kim, Hyeon-Tae;Kim, Ki-Youn
    • Journal of agriculture & life science
    • /
    • v.45 no.3
    • /
    • pp.89-96
    • /
    • 2011
  • The objective of this study is to evaluate reduction efficiency of various air purifiers on airborne microorganism causing air infected animal disease according to sample collection method. Collection efficiencies of MS2 virus and Pseudomonas fluorescens by biosampler was significantly higher than those by button sampler (p<0.05). Regardless of types of air purifier and sample collection method, temporal reduction efficiencies of MS2 virus and P. fluorescens compared to initial background concentration were >50% and >45% on 5 minutes, >70% and >50% on 15 minutes, >80% and >70% on 30 minutes and >90% and >75% on 60 minutes after operating air purifier, respectively. The air purifier of ionizer type showed the highest reduction efficiency on MS2 virus followed by air purifier of electronic precipitation, water filter and dry filter while the reduction efficiency of air purifier on P. fluorescens was highest in the electronic precipitation type followed by ionizer type, dry filter type and water filter type (p<0.05). Based on the results obtained from this study, temporal reduction efficiency of air purifier on MS2 virus was relatively higher than P. fluorescens.

A Study on the Solution of Product Particle Attachment Problem using Practical TRIZ (실용 트리즈를 활용한 제품 Particle 부착 문제의 해결 방안 연구)

  • Kyu-Han Jeong;In-Kwang Song;Jang-Hee Lee
    • Journal of Practical Engineering Education
    • /
    • v.15 no.1
    • /
    • pp.209-221
    • /
    • 2023
  • In the external inspection and packaging stages of products used in the semiconductor manufacturing process, there is a problem in which particles are adsorbed to the product itself or a carrying tool due to electrostatic discharge. This study presents a methodology that can improve the problem of adsorption of particles to a product by using a practical TRIZ technique. By applying the proposed practical TRIZ-based methodology, the problem was defined, and contradictions caused by product waiting time were derived. Among the derived contradictions, physical contradictions were set and the concept of 'space separation' was applied to derive solutions such as 'installation of Ionizer' and 'improvement of the layout of the workroom'. As a result of the experiment by applying 'Ionizer Installation' and 'Workroom Layout Improvement' derived through the application of practical TRIZ, it was confirmed that the particle adsorption problem that occurs during the waiting time of the product can be solved.Through this study, it is expected that workers, facility engineers, and technical engineers working at manufacturing processes will be able to effectively solve the problems they face through creative thinking and change of ideas by using practical TRIZ techniques, and contribute to innovative technology development and productivity improvement.

A Study on Improvement of the Performance of Pulsed AC Ion Bar (2) (바 형태 정전기제거장치의 정전기제거성능 향상을 위한 연구 (2))

  • Lee, Dong Hoon;Choi, Dong Soo;Kim, Sang Min;Park, Jin Chul
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.6
    • /
    • pp.40-45
    • /
    • 2014
  • In display such as LCD, LED, and AMOLED or semiconductor related industries are required to have static ionizer in order to produce reliable goods. The most general type of ionization is called, "corona discharge" that has a slight chances to generate unequal and unstable amount of each +/- ion to the target object. Then, the ionization performance will drastically decrease and end up with quality deterioration problem. continually "A study on the improvement of the performance of pulsed AC ion bar(1)", we have studied consecutive study to improve the current issue via appling "partition wall" at air nozzle surrounding. The results were that the charge decay time and the ion balance was maintained the satisfied range that was within 5 second and ${\pm}50$ V for a 180 days period of time. In additions, the contamination status on the electrode surface was investigated for a 180 days. The little particles was deposited on the electrode surface.

An Experimental Study on the Implementation and Stabilization of Atmospheric Pressure Glow Discharge (대기압 글로우 방전의 구현 및 안정화에 대한 실험적 연구)

  • Choi, Sang-Won
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.4
    • /
    • pp.42-46
    • /
    • 2008
  • Ionizers are essential in various areas of manufacturing industries to protect electrostatic hazards and to reduce inferior products. For ion sources used in the charge neutralizers, there are corona discharge, soft X-ray, ultraviolet and glow discharge. Glow discharge has lots of attractive properties, such as lower discharge sustaining voltage, no generation of ozone, and so on. In this paper, we did an experimental study to trace the mechanism and stabilization of atmospheric pressure glow discharge using the several size and shape of electrodes. As an experimental result, to sustain conditions of atmospheric pressure glow discharge is that discharge voltage is 360V, discharge current is 12mA, apply frequency is 1kHz between electrodes when positive electrode is molybdenum(Mo) and negative electrode is copper(Cu). We confirmed that the mechanism and stabilization of atmospheric glow discharge is deeply concerned with the shape and material of electrode for discharge. Especially, glow discharge in atmospheric pressure was well generated and sustained according with the physical properties used electrode materials, example melting point, thermal conductivity, and etc.

Charge Distribution of Submicron Particles Charged by Spray Electrification or Corona Discharge (분무 및 코로나 방전에 의해 대전된 서브마이크론 입자의 대전량 분포)

  • Lee, Jae-Bok;Bae, Gwi-Nam;Hwang, Jeong-Ho;Lee, Gyu-Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.1
    • /
    • pp.124-132
    • /
    • 2001
  • This paper reports on the charge distribution measurements of submicron particles for three different charging mechanisms, which are spray electrification, bipolar ionization and corona discharge process, respectively. The number of elementary charges per particle was investigated by classifying and counting of a discrete mobility class. Charge distribution measurements were performed with NaCl particles generated from a collision atomizer for 0.01, 0.1, 1% NaCl solutions. Experimental results show than charge level of atomized NaCl particles is high and decreases with increasing the dissolved ion concentration. The charge level of the atomized NaCl particles can be reduced to that o Boltzmann equilibrium conditions by the bipolar ionization(Po(sup)210 bipolar ionizer). The charge level on NaCl particles passing through the corona discharge reactor is much higher than those of atomized or bipolar ionized NaCl particles. The evaluation of these measurements results in charge distribution of the submicron particles.

A Study for Development the Air Cleaner Using Air Ionizing Phenomena and Optical Catalizer (공기전리 현상과 광촉매를 이용한 공기정화 장치 개발에 관한 연구)

  • Shim, Chung-Han;Lee, Won-Dae;Lee, Dong-Hoon;Jung, Yong-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.5 s.77
    • /
    • pp.28-33
    • /
    • 2006
  • The rapidly advanced industrial society takes advantage of high-technology, but it also suffered from the side effects such as various diseases by contamination. Of these problems, air pollution is considered as the most important problem nowadays. Air contamination is not only limited outdoors, but it also causes more serious effect in our indoor air environment. Depending on the notion that indoor air effects physical health seriously, the needs of the air cleaner is more earnest. Therefore, the main purpose of this study is to develop the air cleaner to meet the standard and get rid of poisonous and harmful material from the atmosphere by using a Corona Discharge. According to the purpose of this study, We set the negative ion generator, the UV, $TiO_{2}$ optical catalyzer, the electrical dust collector and the air filter in series order. It emits a lot of negative ions. We use these ions to purify harmful factors and contaminated materials. We collect the dust using static power that comes from the discharge of corona. At the same time, we try to develop the air cleaner to keep the air quality to meet the standard and kill the various viruses using UV LED and $TiO_{2}$ optical catalyzer. In this study, we use the UV LED that is smaller and efficient than a existing UV lamp. What is more, the UV LED has a features that a stabilizer occupying much space is not needed any more.

Combustion Characteristics of Ionized Fuels for Battery System Safety (배터리 시스템 안전을 위한 이온화 연료의 연소 특성)

  • Ko, Hyeok Ju;Lee, Eui Ju
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.1
    • /
    • pp.22-27
    • /
    • 2018
  • Many electronic devices are powered by various rechargeable batteries such as lithium-ion recently, and occasionally the batteries undergo thermal runaway and cause fire, explosion, and other hazards. If a battery fire should occur in an electronic device of vehicle and aircraft cabin, it is important to quickly extinguish the fire and cool the batteries to minimize safety risks. Attempts to minimize these risks have been carried out by many researchers but the results have been still unsatisfied. Because most rechargeable batteries are operated on the ion state during charge and discharge of electricity and the combustion of ion state has big difference with normal combustion. Here we focused on the effect of ions including an electron during combustion process. The effects of an ionized fuel on the flame stability and the combustion products were experimentally investigated in the propane jet diffusion flames. The burner used in this experiment consisted of 7.5 mm diameter tube for fuel and the propane was ionized with th ionizer (SUNJE, SPN-11). The results show that toe overall flame stability and shape such as flame length has no significant difference even in the higher ion concentration. However the fuel ionization affects to the pollutant emissions such as NOx and soot. NOx and CO emissions measured in post flame region decreased by fuel ionization, especially high fuel velocity, i.e. high ion density. TGA analysis and morphology of soot by TEM indicates that the fuel ionization makes soot to be matured.