• Title/Summary/Keyword: ion detection

Search Result 668, Processing Time 0.026 seconds

Determination of Tb(III) in aqueous solution by fluorescence spectrometry (형광분광법에 의한 수용액 중의 Tb(III) 정량)

  • Lee, Sang Hak;Bae, Zun Ung;Chung, Hae Young;Choi, Sang Seob
    • Analytical Science and Technology
    • /
    • v.10 no.4
    • /
    • pp.274-281
    • /
    • 1997
  • Methods to determine terbium(III) ion in aqueous solution by measuring the enhanced fluorescence intensity of terbium(III)-terephthalic acid(TPA) complex ion have been studied. The optimum analytical conditions for pH, excitation wavelength and concentration of TPA were found to be 6.0, 260nm and $4.0{\times}10^{-4}M$, respectively. The fluorescence intensity of the terbium(III) complex ion was further increased with addition of trioctylphosphine oxide (TOPO). In this case Triton X-100 was used to dissolve TOPO in aqueous solution. When TOPO was used, the optimum analytical conditions for pH, excitation wavelength, and concentrations of TPA, TOPO and Triton X-100 were found to be 4.5, 285nm. $4.0{\times}10^{-4}M$, $5.0{\times}10^{-5}M$, and 0.05%, respectively. Under the optimum experimental conditions, calibration curve for Tb(III) was linear over the range from $4.0{\times}10^{-8}M$ to $4.0{\times}10^{-5}M$ and the detection limit was $4.0{\times}10^{-8}M$. When TOPO was used, the concentration range of linear response, and the detection limit were $4.0{\times}10^{-9}M$ to $2.0{\times}10^{-6}M$, and $4.0{\times}10^{-9}M$, respectively. Effects of interferences from various cations for the determination of terbium(III) ion were also investigated.

  • PDF

A Naked Eye Detection of Fluoride with Urea Receptors Which have both an Azo Group and a Nitrophenyl Group as a Signaling Group

  • Dang, Nhat Tuan;Park, Jin-Joo;Jang, Soon-Min;Kang, Jong-Min
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.5
    • /
    • pp.1204-1208
    • /
    • 2010
  • Anion recognition via hydrogen-bonding interactions could be monitored with changes in UV-vis absorption spectra and in some cases easily monitored with naked eye. Urea receptors 1 and 2 connected with both an azo group and a nitrophenyl group as a signaling group for color change proved to be an efficient naked eye receptor for the fluoride ion. The anion recognition phenomena of the receptors 1 and 2 via hydrogen-bonding interactions were investigated through UV-vis absorption and $^1H$ NMR spectra.

Development of PZT Piezoelectric Biosensor for the Detection of Formaldehyde (Formaldehyde 측정을 위한 PZT 압전 바이오센서 개발)

  • 김병옥;곽성곤;임동준
    • KSBB Journal
    • /
    • v.13 no.5
    • /
    • pp.477-482
    • /
    • 1998
  • A biosensor with PZT piezoelectric ceramic crystal was developed for the detection of formaldehyde gas. Poled PZT piezoelectric ceramic disk was made from ZrO2, TiO2 and Nb2O5, together with the addition of PbO and polyvinyl alcohol, through various processes of mixing, calcination drying, crushing, forming, sintering, polishing, ion coating and poling. Oscillator circuit of sensor was made of operational amplifier(AD811AN). Formaldehyde dehydrogenase was immobilized onto a piezoelectic ceramic crystal, together with the cofactors, reduced glutathione and nicotinamide adenine dinucleotide. The effect of flow rate on the sensitivity was determined by varing the flow rate of carrier gas from 24.7mL/min to 111.7mL/min through detector cell. The results indicated that as the flow rate was increased, the recovery rate was increased. And a significant increase in the sensitivity was observed in enhanced flow rate of carrier gas. Frequency difference(ΔF) of immobilized PZT piezoelectic disk increased proportionally to the concentration gas and reproduced to repeated exposures of formaldehyde gas(28ppm, Δ68Hz).

  • PDF

Diagnostic Assay of Toxic Zinc in an Ex Vivo Cell Using Voltammetry

  • Ly, Suw-Young;Yoo, Hai-Soo
    • Toxicological Research
    • /
    • v.28 no.2
    • /
    • pp.123-127
    • /
    • 2012
  • Voltammetric detection of the toxic Zn ion was investigated using a fluorine-doped graphite pencil electrode (FPE). It is notable from the study that pencils were used as reference and working electrodes. In all the experiments, a clean seawater electrolyte solution was used to yield good results. The analytical working range was attained to 10 ${\mu}gL^{-1}$. The optimized voltammetric condition was examined to maximize the effect of the detection of trace Zn. The developed sensor was applied to an earthworm's tissue cell. It was found that the methods can be applicable to in vivo fluid or agriculture soil and plant science.

Study on the Resistivity Leakage Current Detection and Properties Analysis of Electrical Installat ion (전기설비의 저항성 누설전류 검출 및 특성 해석에 관한 연구)

  • Choi, Chung-Seog;Hahn, Song-Yop
    • Proceedings of the KIEE Conference
    • /
    • 2008.09a
    • /
    • pp.301-304
    • /
    • 2008
  • In this paper, we study from of flowing leakage current in electrical installation. Leakage current is expressed by a resistivity leakage current($I_{gr}$), a capacitive leakage current($I_{gc}$), an inductivity leakage current($I_{gl}$). General Zero Phase Current Transformer (ZCT) detect a leakage current($I_{g}$) that are conjoined resistivity leakage current and capacitive leakage current. In case $I_{gr}$ is big than $I_{gc}$, there is no singular problem in leakage current detection of system. But, in case $I_{gc}$ is big than $I_{gr}$, earth leakage breaker can not prevent accident effectively. Can lower electric leakage perception current to 5 mA if apply resistivity leakage current detecting circuit. We can achieve prevention of electricity disaster spontaneously.

  • PDF

Determination of Rare Earth Elements Abundance in Alkaline Rocks by Inductively Coupled Plasma Mass Spectrometry (ICP-MS) (ICP-MS를 이용한 알칼리암의 희토류원소 정량분석)

  • Hur, Soon-Do;Lee, Jong-Ik;Lee, Mi-Jung;Kim, Yea-Dong
    • Ocean and Polar Research
    • /
    • v.25 no.1
    • /
    • pp.53-62
    • /
    • 2003
  • Inductively coupled plasma mass spectrometry (ICP-MS) is useful instrument for determining abundance of rare earth elements, due to very low detection limits and rapid data acquisition. In this article, two methods are used for decomposition of alkaline rocks; close vessel acid digestion and $Na_2Co_3$ fusion. The two analytical results show good agreements. Considering total dissolved solids and detection limits, the most adequate dilution factor is 5,000 times. Polyatomic ion interferences during analysis can give rise to Inaccuracies. After correction from oxide and hydroxide interference, the analytical result show 20-30% decrease for Gd and Tm, 10-20% decrease for Tb and Er. In comparing the analytical results from KORDI with other institutes, most rare earth elements abundance show good agreements except Lu.

The Identification of Corydalis Tuber by Detecting of Tertiary and Quaternary Alkaloids (3.4급 알칼로이드의 검출에 의한 현호색의 확인)

  • Kim, Dae-Keun;Kim, Ki-Duck;Eom, Dong-Ok
    • Korean Journal of Pharmacognosy
    • /
    • v.30 no.1
    • /
    • pp.54-58
    • /
    • 1999
  • A method using coloric and spectrophotometric detection have been developed for the identification of the tertiary or quaternary alkaloids contained in Corydalis tuber and its preparations. The principle is based on the formation or decomposition of complex compounds. The complex compound of the tertiary and quaternary alkaloids have been formed by adding tetrathiocyanatocobaltate [II] ion to the test soln. Diverse crude drugs were screened using this method and the results indicated that isoquinoline, aconitine-type alkaloids in crude drugs can be readily detected. The method is simple, convenient, reproducible and applicable to the verification of the crude drug Corydalis tuber and its preparations.

  • PDF

Detection of Toxic Heavy Metal, Co(II) Trace via Voltammetry with Semiconductor Microelectrodes

  • Ly, Suw Young;Lee, Chang Hyun;Koo, Jae Mo
    • Toxicological Research
    • /
    • v.33 no.2
    • /
    • pp.135-140
    • /
    • 2017
  • The cobalt (Co(II)) ion is a main component of alloys and considered to be carcinogenic, especially due to the carcinogenic and toxicological effects in the aquatic environment. The toxic trace of the Co(II) detection was conducted using the infrared photodiode electrode (IPDE) using a working electrode, via the cyclic and square-wave anodic stripping voltammetry. The results indicated a sensitive oxidation peak current of Co(II) on the IPDE. Under the optimal conditions, the common-type glassy carbon, the metal platinum, the carbon paste, and the carbon fiber microelectrode were compared with the IPDE in the electrolyte using the standard Co(II). The IPDE was found to be far superior to the others.

Development of Analytical Method for Polychlorinated Biphenyls and Organochlorine Pesticides in Air (대기 중 PCBs와 유기염소계 살충제의 정량을 위한 분석 방법 개발)

  • 최민규;여현규;김태욱;천만영;선우영
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.6
    • /
    • pp.475-485
    • /
    • 2002
  • An analytical method was investigated for the meaiiurement of polychlorinated biphenyls (PCBs) and organochlorine pesticides (OCPs) concentrations in air samples. Procedures required for column chromatographic clean up. silicagel (stage I) and gel permeation chromatography (stage II), were discussed. Identification and quantification of PCBs and OCPs were performed using a combination of gas chromatography/mass spectrometry/ selected ion monitoring. Recovery tests calculated from six samples are 68∼137% for PCBs and 58∼130% for OCPs except for endrin aldehyde. Instrumental detection limits determined for the PCBs and OCPs varied from 0.05 to 0.18 pg/m3 and from 0.71 to 16.82 pg/㎥, respectively. The method has been applied to the analysis of air samples collected at Ansung city, Kyonggi province, Korea. This method may serve as a screening protocol for the simultaneous determination of PCBs and OCPs in air.

Teaching a Known Molecule New Tricks: Optical Cyanide Recognition by 2-[(9-Ethyl-9H-carbazol-3-yl)methylene]propanedinitrile in Aqueous Solution

  • Tang, Lijun;Zhao, Guoyou;Wang, Nannan
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.11
    • /
    • pp.3696-3700
    • /
    • 2012
  • The colorimetric and fluorescent cyanide recognition properties of 2-[(9-ethyl-9H-carbazol-3-yl)methylene]-propanedinitrile (1) in $CH_3CN-H_2O$ (2/1, v/v, HEPES 10 mM, pH = 7.0) solution were evaluated. The optical recognition process of probe 1 exhibited high sensitivity and selectivity to cyanide ion with the detection limit of $2.04{\times}10^{-6}$ M and barely interfered by other coexisting anions. The sensing mechanism of probe 1 is speculated to undergo a nucleophilic addition of cyanide to dicyanovinyl group present in compound 1. The colorimetric and fluorescent dual-modal response to cyanide makes probe 1 has a potential utility in cyanide detection.