• Title/Summary/Keyword: ion Permeability

Search Result 215, Processing Time 0.028 seconds

An Experimental Study on the Recycled! Concrete Durability (재생 콘크리트의 내구성에 관한 실험적 연구)

  • 이명규;정상화;김인수
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.675-680
    • /
    • 2003
  • In this study, various tests are performed for the durability of the concrete using domestic recycled coarse aggregate including drying shrinkage, permeability, freezing-thawing resistance and $CO_2$ diffusivity. Tests of freezing-thawing resistance, chloride ion permeability and $CO_2$ diffusivity of recycled concrete show favorable results. But, the maximum drying shrinkage ratio to normal concrete is increased 24% with increasing substitution ratio of recycled aggregate. Therefore, for the use of recycled concrete in structures, the preventive measures of drying shrinkage is necessary in mix design and the adequate substitution ratio of recycled aggregate should be proposed.

  • PDF

Gas permeation property of organic-inorganic hybrid membrane made by ion-beam irradiation

  • Kawakami, Hiroyoshi
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 2004.05a
    • /
    • pp.90-93
    • /
    • 2004
  • In this study, we have reported an organic-inorganic hybrid membrane, which exhibits an asymmetric structure consisted of a carbonized skin layer and a polyimide porous substructure, to synthesize a novel gas separation membrane combining high gas permeability and selectivity. Both the gas permeability and selectivity of the carbonized layer significantly enhanced when compared with those determined in the control polyimide.

  • PDF

Degradation of Membrane for PEM Fuel Cell with Hydrogen Peroxide (과산화수소에 의한 고분자전해질 연료전지 막의 열화)

  • Kim, Tae-Hee;Lee, Jung-Hun;Park, Kwon-Pil
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.438-442
    • /
    • 2006
  • The degradation of Nafion membrane by hydrogen peroxide was investigated in polymer electrolyte membrane fuel cell (PEMFC). Degradation tests were carried out in a solution of $10{\sim}30%$ hydrogen peroxide containing 4ppm $Fe^{2+}$ ion which is well known as Fenton's reagent at $80^{\circ}C$ for 48hr. Characterization of degraded membranes were examined through the IR, Water-uptake, Ion exchange capacity, mechanical strength and $H_2$ permeability. After degradation, C-F, S-O and C-O chemical bonds of membrane were broken by radical formed by $H_2O_2$ decomposition. Breaking of C-F bond which is the membrane backbone reduced the mechanical strength of Nafion membrane and hence induced pinholes, resulting in increase of $H_2$ crossover through the membrane. Also the decomposition of C-O and S-O, side chain and terminal bond of membrane, decreased the ion exchange capacity of the membrane.

  • PDF

Characteristics of Poly(arylene ether sulfone) Membrane for Vanadium Redox Flow Battery (바나듐 레독스 흐름전지용 Poly(arylene ether sulfone) 막의 특성)

  • Oh, Sung-June;Jeong, Jae-Hyeon;Shin, Yong-Cheol;Lee, Moo-Seok;Lee, Dong-Hoon;Chu, Cheun-Ho;Kim, Young-Sook;Park, Kwon-Pil
    • Korean Chemical Engineering Research
    • /
    • v.51 no.6
    • /
    • pp.671-676
    • /
    • 2013
  • Recently, there are many efforts focused on development of Redox Flow Battery (RFB) for large energy storage system. Economical hydrocarbon membranes alternative to fluorinated membranes for RFB membrane are receiving attention. In this study, characteristics of poly(arylene ether sulfone) (PAES) were compared with expensive fluorinated membrane at VRB (Vanadium Redox Flow Battery) operation condition. Permeability of vanadium ion through membrane, ion exchange capacity (IEC), change of OCV, swelling, charge-discharge curves and energy efficiency were measured. PAES membrane showed lower permeability of vanadium ion, higher IEC and then higher energy efficiency compared with Nafion 117 membranes.

Ion Permeation of PVA/Gelatin Blend Membrane Prepared Under High Electric Field (고전장하에서 제조된 PVA/Gelatin 블렌드막의 이온투과 특성)

  • Huh, Yang-Il;Joe, Jeong-Woong
    • Polymer(Korea)
    • /
    • v.30 no.6
    • /
    • pp.568-571
    • /
    • 2006
  • Poly(vinyl alcohol) (PVA)/gelatin(GEL) blend membranes were prepared under a high electric field, and their swelling and ion permeation behaviors were investigated. For alkali metal salts such as LiCl, NaCl and KCl, the permeability coefficients were increased until the electric field of 10 kV due to the decreased tortuosity, whereas they were decreased over 10 kV owing to the increase of the degree of crystallinity. The swelling ratios of the blend membranes showed the minimum values at pH 6, while the permeability coefficients exhibited the maximum values at the same condition. The minimum swelling ratios result from the repulsion effect between charged groups in acidic or basic regions, and the maximum permeabilities result from Donnan exclusion effect in the same regions. Especially, the per-meability coefficient for KCl of the membrane increased steeply to five times at $40^{\circ}C$ than below $35^{\circ}C$.

Analytical Study on the Chloride Ion's Permeation of Reinforced Concrete Repaired by Patching Repair Material (단면수복재로 보수시공한 철근콘크리트내로의 염화물이온 침투에관한 해석적 연구)

  • Yun, Sun-Young;Shin, Sang-Heon;Ryu, Byung-Cheol;Lee, Han-Seung
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.617-620
    • /
    • 2008
  • When the RC structure repaired by patching repair method, which method refilles with patching repair material after removes degraded area, It is necessary to determine chloride ion's permeation from outside of the RC structure repaired by patching repair material. Therefore, in this study, damage from sea environment of structure was predicted, moreover, diffusion coefficient of concrete also determined to figure out rebar's corrosion and concentration of chloride ion. RCPT(Rapid Chloride Permeability Test) was used for ditermination of patching repair material's diffusion coefficient, also connection between material thickness and effect of chloride ion's permeation was examined in analytically. Results which derived by experimental test was used in FEM(Finite Element Method) and equation suggested by JSCE to predict concentration of chloride ion in different distance from surface.

  • PDF

An Evaluation of Reinforced Concrete Durability in Chloride Attack Environment under Sustained Load (염해 환경하에서 지속하중을 받는 철근콘크리트 부재의 내구성 평가)

  • Hong, Jun-Seo;Im, Chang-Hun;Yoon, Sang-Chun;Jee, Nam-Yong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.1045-1050
    • /
    • 2001
  • This study was performed to evaluate reinforced concrete durability in chloride attack environment under sustained load by the corrosion of reinforcing bars and the permeation of chloride ion. Generally, it is regarded that permeability of chloride ion is determined by the properties of concrete, but the effects of load which make alternation of concrete inner structure such as crack and so on should not neglected. In this study, it is shown that the relation between bending load on RC beam, deflection and crack of specimen, permeation of chloride ion, rating of re-bar corrosion, and the relation between compression load and permeation of chloride ion. Therefore the effects of load on permeation of chloride ion and re-bar corrosion are evaluated.

  • PDF

Characterization of Polymer Blends of Poly(ether sulfone)/Sulfonated Poly(ether ether ketone) for DMFC (직접메탄올 연료전지용 Poly(ether sulfone)/Sulfonated Poly(ether ether ketone) 블렌드 막의 특성 연구)

  • Cheon, Hun Sang;Lee, Choong Gon;Hong, Seong Uk
    • Applied Chemistry for Engineering
    • /
    • v.16 no.1
    • /
    • pp.144-149
    • /
    • 2005
  • Sulfonated poly(ether ether ketone) (SPEEK) was blended with poly(ether sulfone) (PES) at various compositions. To investigate the possibility of using the blend membranes as polymer electrolyte membranes for direct methanol fuel cell, the blend membranes were characterized in terms of methanol permeability, proton conductivity, ion exchange capacity, and water content. Both proton conductivity and methanol permeability of SPEEK were relatively high. As the amount of PES increased, methanol permeability decreased more rapidly compared to proton conductivity. The experimental results indicated that the blend membrane with 40 wt% PES was the best choice in terms of the ratio of proton conductivity to methanol permeability.

Effects of Reactive Gas Addition on the Mechanical Property and Water Permeability of IZO Films Deposited by DC Sputtering for Application to Flexible OLED (DC 마그네트론 스퍼터로 증착한 flexible OLED용 IZO 박막의 기계적 특성과 투습특성에 미치는 반응성 가스 첨가의 효과)

  • Cheon, Ko-Eun;Lee, Dong-Yeop;Cho, Young-Rae;Song, Pung-Keun
    • Journal of the Korean institute of surface engineering
    • /
    • v.40 no.6
    • /
    • pp.245-249
    • /
    • 2007
  • Amorphous IZO films were deposited on PET substrate by DC magnetron sputtering without substrate heating. In order to investigate effect of reactive gas addition on film properties, 0.2-0.4% of $H_2$ or $O_2$ gas was introduced during the deposition. Deposited IZO films were evaluated with mechanical property, electrical property, and water permeability. In the case of $H_2$ gas addition, mechanical property showed clear degradation compared to $O_2$ gas. In the case of $O_2$ gas, water permeability of the IZO film was increased compared to $H_2$ gas which could be attributed to the low adhesion of the film caused by bombardment of high energy negative oxygen ion. As a result, it is confirmed that water permeability of the film could be strongly affected by adhesion of the film.

Basic Properties of Latex-Modified Concrete Using Fly-ash (플라이애쉬를 이용한 라텍스개질 콘크리즈의 기초물성 연구)

  • Hong, Chang-Woo;Jeong, won-Kyong;Kim, Kyong-jin;Yun, Kyong-ku
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.1A
    • /
    • pp.205-211
    • /
    • 2006
  • The purpose of this study was to evaluate the effects of fly-ash on strength development and durability of latex-modified concrete (LMC) and ordinary portland cement concrete (OPC). Main experimental variables were latex contents (0%, 10%, 15%) and fly-ash content (0, 10%, 20%, 30%). Air content and slump tests were performed to check the basic properties of fresh concretes, and compressive strength, flexural strength, rapid chloride ion permeability and chemical resistance were measured to analyze the basic properties of hardened concretes. The test results showed that air contents of LMC with fly ash decreased as fly-ash contents increased from 0% to 30%. Compressive and flexural strength developments of LMC with fly ash were quite similar to those of LMC without fly ash. However, the long-term flexural strength development of LMC with fly ash after 90 days were bigger than that of LMC without fly ash. Chloride ion permeability and chemical resistance decreased rapidly as the content of fly ash increased. Thus, fly ash could be used at LMC in order to reduce water permeability.