• Title/Summary/Keyword: inverter control system

Search Result 1,563, Processing Time 0.027 seconds

Development of Inverter Monitoring system (소형 인버터 모니터링 시스템 개발)

  • Myoung Hee-chul;Park Dong-ho;Kim Jung-han
    • Proceedings of the KIPE Conference
    • /
    • 2002.11a
    • /
    • pp.167-170
    • /
    • 2002
  • Recently, automation and communication technology leads to change of working condition to safe and convenient. Inverter control and monitoring software needs to apply and update to inverter applicable fields to make people feel easy and comfortable on working Install systems and drive them. in this paper, we introduced design methods of communication software and developed inverter control and monitoring system which can control and monitor inverters with serial communication.

  • PDF

Development of Inverter for Elevator Door Control (엘리베이터 자동문제어 인버터 개발)

  • Kim, J.K.;Choi, U.D.;Jung, M.K.;Choi, S.K.;Yun, J.H.;Han, S.B.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07a
    • /
    • pp.308-310
    • /
    • 1995
  • Most of the elevator door controllers have been controlled by DC Motors as an actuator. Recently, The control system using AC induction motor and general purpose inverter has been applied to control of elevator door. But there are some difficulties in making use of this system, such as adjustment of door speed pattern, door open-close time, and security of passenger safety. In order to solve these problems, a special inverter has, been developed with an encoder feedback. From the result of field-test, we proved that a special inverter with encoder feedback device has come to considerable effect. Until now about 1,200 sets of these inverters are operated in Korea and about 100 sets are operated in South-east Asia.

  • PDF

Bi-directional Photovoltaic Inverter with High Efficiency and Low Noise (고 효율, 저 잡음 특성을 가지는 양방향 태양광 인버터)

  • Lee, Sung-Ho;Kwon, Jung-Min;Kwon, Bong-Hwan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.6
    • /
    • pp.539-545
    • /
    • 2012
  • Due to merits cost and efficiency, the transformer-less type photovoltaic (PV) inverters have been popularized in the solar market. However, the leakage current flowing through a parasitic capacitor between PV array and ground can cause adverse effect in the transformer-less PV system. In this paper, a bi-directional PV inverter with high efficiency and low noise is proposed for the PV system with an energy storage device. The proposed inverter is a transformer-less type and performs the bi-directional power control between dc sources and grid with high efficiency. In addition, the proposed inverter can suppress the leakage current and obtain low noise characteristic. Finally, 3-kW prototype was implemented to confirm validity of the proposed inverter.

A Study on Development of Three-Phase Inverter Using Single-Chip Microprocessor (싱글칩 마이크로 프로세서를 이용한 3상 인버터 개발에 관한 연구)

  • Kim, Ho-Jin;Park, Su-Young;hahm, Yeon-Chang;Shin, Woo-Seok;Choe, Gyu-Ha
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.568-572
    • /
    • 1991
  • This paper describes the three-phase inverter system for 1/2[HP] induction servo motor, using TMS370C050 single-chip microprocessor. The Power MOSFETs are used for PWM inverter circuit because of the advantages such as less harmonic losses and smaller peak current, less torque ripples and noises. Single-chip microprocessor enables the whole controller to be simple and reduced size as well as to more stable and flexible. The basic structures are shown for the power circuit, including the protection and driving circuitry, and the control loops for inverter control functions. The experimental results are given for the prototype PWM inverter system.

  • PDF

Review of Multifunctional Inverter Topologies and Control Schemes Used in Distributed Generation Systems

  • Teke, Ahmet;Latran, Mohammad Barghi
    • Journal of Power Electronics
    • /
    • v.14 no.2
    • /
    • pp.324-340
    • /
    • 2014
  • Recent developments in power electronics technology have spurred interest in the use of renewable energy sources as distributed generation (DG) generators. The key component in DG generators is a grid-connected inverter that serves as an effective interface between the renewable energy source and the utility grid. The multifunctional inverter (MFI) is special type of grid-connected inverter that has elicited much attention in recent years. MFIs not only generate power for DGs but also provide increased functionality through improved power quality and voltage and reactive power support; thus, the capability of the auxiliary service for the utility grid is improved. This paper presents a comprehensive review of the various MFI system configurations for single-phase (two-wire) and three-phase (three- or four-wire) systems and control strategies for the compensation of different power quality problems. The advances in practical applications and recent research on MFIs are presented through a review of nearly 200 papers.

NPC Type 3 Level Inverter Operation in Overmodulation Region (NPC형 3레벨 인버터 과변조영역운전)

  • Lee, Jae-Moon;Choi, Jae-Ho;Lee, Eun-Kyu;Yeom, Sang-Gu
    • Proceedings of the KIEE Conference
    • /
    • 2007.04c
    • /
    • pp.194-197
    • /
    • 2007
  • This paper proposes a linearization technique for the 3 level NPC type inverter, which increases the linear control range of inverter up to the 6-step inverter. The overmodulation range is divided into two modes depending on the modulation index(MI), In mode I, the reference angles are derived from the Fourier series expansion of the reference voltage corresponds to the MI. In mode II, the holding angles are also derived in the same way. Therefore, it is possible to obtain the linear control and the maximized utilization of PWM inverter output voltage.

  • PDF

Multi-modulating Pattern - A Unified Carrier based PWM method In Multi-level Inverter - Part 2

  • Nho Nguyen Van;Youn Myung Joong
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.625-629
    • /
    • 2004
  • This paper presents a systematical approach to study carrier based PWM techniques (CPWM) in diode-clamped and cascade multilevel inverters by using a proposed named multi-modulating pattern method. This method is based on the vector correlation between CPWM and the space vector PWM (SVPWM) and applicable to both multilevel inverter topologies. A CPWM technique can be described in a general mathematical equation, and obtain the same outputs similarly as of the corresponding SVPWM. Control of the fundamental voltage, vector redundancies and phase redundancies in multilevel inverter can be formulated separately in the CPWM equation. The deduced CPWM can obtain the full vector redundancy control, and fully utilize phase redundancy in a cascade inverter In this continued part, it will be deduced correlation between CPWM equations in multi-carrier system and single carrier system, present the mathematical model of voltage source inverter related to the common mode voltage and propose a general algorithm for multi-modulating modulator. The obtained theory will be demonstrated by simulation results.

  • PDF

A Novel Filter Design for Output LC Filters of PWM Inverters

  • Kim, Hyo-Sung;Sul, Seung-Ki
    • Journal of Power Electronics
    • /
    • v.11 no.1
    • /
    • pp.74-81
    • /
    • 2011
  • The cutoff frequency of the output LC filters of PWM inverters limits the control bandwidth of the converter system while it attenuates voltage ripples that are caused by inverter switching activities. For a selected cutoff frequency of an output LC filter, an infinite number of L-C combinations is possible. This paper analyses the characteristics of output LC filters for PWM inverters terms of the L-C combinations. Practical circuit conditions such as no-loads, full resistive-loads, and inductive-load conditions are considered in the analysis. This paper proposes a LC filter design method for PWM inverters considering both the voltage ynamics and he inverter stack size. An experimental PWM inverter system based on the proposed output LC lter design uideline is built and tested.

Test bed for Advanced function of Smart Inverter and Results Based on Real-Time Simulation Platform (실시간 시뮬레이터 기반의 스마트 인버터 제어기능 시험 환경 구축 및 시험 결과)

  • Sim, Junbo;Ban, Minho;Lim, Hyeonok;Cho, Seong-Soo
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.7 no.1
    • /
    • pp.107-114
    • /
    • 2021
  • High penetration of renewable energy generators causes unnecessary investment for power system facilities. Especially with Korean government policies such as Renewable Energy 3020 and Inter-connection support Responsibility of KEPCO for 1 MW DERs, the applications of DER interconnection in distribution system have been increasing. To save the investment, smart control functions for DERs are required and the test bed for the inverters which have not been prepared are necessary to insure DER inter-connection stability. For this, test bed for advanced functions of a smart inverter has been constructed and the tests for necessary functions have been implemented. In this paper, the test bed and environment as well as specifications are introduced and the test results for the validation of the functions are analyzed.

Regeneration inverter system for DC traction system (직류 지하철 급전시스템용 회생인버터 시스템)

  • Cho, Kee-Hyun;Jang, Su-Jin;Kim, Jong-Yoon;Won, Chung-Yuen;Kim, Yong-Ki
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.28-32
    • /
    • 2007
  • In this paper, a unified regenerative inverter and control algorithm are proposed in order to perform regenerative action and active power filter action. While the regenerative mode of traction, it works as regenerative inverter to reduce a excessive power of DC bus line and the powering mode of the traction, it works as active power filter to compensate ac current distortion, power factor, and voltage unbalance. In the paper, a regeneration inverter used PWM DC/AC inverter algorithm. And an active power filter used p-q theory. We are carrying out a mode analysis of DC traction system similar to actual system with MG-set and experimenting with prototype model. Through the simulation and experiment, we were proving the regeneration inverter operation which suggested in this paper.

  • PDF