• Title/Summary/Keyword: interpretation technique

Search Result 367, Processing Time 0.035 seconds

Interpretation of Image-Guided Biopsy Results and Assessment (영상유도하 조직검사의 해석과 판정)

  • Su Min Ha;Jung Min Chang
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.2
    • /
    • pp.361-371
    • /
    • 2023
  • The success of image-guided breast biopsy depends on the biopsy method, needle selection, and appropriate technique based on the accurate judgment by the radiologist at biopsy. However, insufficient or inappropriate sampling of specimens may result in false-negative results or pathologic underestimation. Therefore, image-pathology concordance assessments after biopsy are essential for appropriate patient management. Particularly, the assessment of image-pathology concordance can avoid false-negative reports of breast cancer as a benign pathology. Therefore, this study aimed to discuss factors that impact the accurate interpretation of image-guided breast biopsy along with the appropriate assessments.

Automated Analysis Technique Developed for Detection of ODSCC on the Tubes of OPR1000 Steam Generator

  • Kim, In Chul;Nam, Min Woo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.6
    • /
    • pp.519-523
    • /
    • 2013
  • A steam generator (SG) tube is an important component of a nuclear power plant (NPP). It works as a pressure boundary between the primary and secondary systems. The integrity of a SG tube can be assessed by an eddy current test every outage. The eddy current technique(adopting a bobbin probe) is currently the main technique used to assess the integrity of the tubing of a steam generator. An eddy current signal analyst for steam generator tubes continuously analyzes data over a given period of time. However, there are possibilities that the analyst conducting the test may get tired and cause mistakes, such as: missing indications or not being able to separate a true defect signal from one that is more complicated. This error could lead to confusion and an improper interpretation of the signal analysis. In order to avoid these possibilities, many countries of opted for automated analyses. Axial ODSCC (outside diameter stress corrosion cracking) defects on the tubes of OPR1000 steam generators have been found on the tube that are in contract with tube support plates. In this study, automated analysis software called CDS (computer data screening) made by Zetec was used. This paper will discuss the results of introducing an automated analysis system for an axial ODSCC on the tubes of an OPR1000 steam generator.

Controlled Source Magnetotellurics with Vector Measurement Using Electric and Magnetic Sources (전기장 또는 자기장 송신원을 이용한 벡터 CSMT)

  • Lee, Heuisoon;Song, Yoonho
    • Economic and Environmental Geology
    • /
    • v.30 no.5
    • /
    • pp.451-458
    • /
    • 1997
  • The horizontal magnetic dipole as well as electrical dipole was adopted as a source to compute one-dimensional electromagnetic field behavior in controlled source magnetotellurics. he Cagniard impedances due to horizontal magnetic dipole source, especially phases, showed better frequency characteristics than those due to electric one. The magnetic dipole is inferior to the electric dipole in the point of relatively weak transmitting power at low frequency. But considering high resistivity charateristics of Korean geology, the magnetic dipole source is recommended for the survey up to depth of 500 m. A vector CSMT was introduced to get more reliable data in the area of two- or three-dimensional structures. A software and interpretation technique using polarization ellipses were developed. The technique was tested by synthetic data, which provided theoretical basis of the methodology. Although CSMT has inevitable limitation of investigation depth due to practically possible source-receiver separation, we proposed to use the technique developed in this paper where MT is not available, for example, in extremely noisy area or for shallow target.

  • PDF

Experimental determination of the buckling load of rectangular plates using vibration correlation technique

  • Singhatanadgid, Pairod;Sukajit, Padol
    • Structural Engineering and Mechanics
    • /
    • v.37 no.3
    • /
    • pp.331-349
    • /
    • 2011
  • This study investigates the use of a vibration correlation technique (VCT) to identify the buckling load of a rectangular thin plate. It is proposed that the buckling load can be determined experimentally using the natural frequencies of plates under tensile loading. A set of rectangular plates was tested for natural frequencies using an impact test method. Aluminum and stainless steel specimens with CCCC, CCCF and CFCF boundary conditions were included in the experiment. The measured buckling load was determined from the plot of the square of a measured natural frequency versus an in-plane load. The buckling loads from the measured vibration data match the numerical solutions very well. For specimens with well-defined boundary conditions, the average percentage difference between buckling loads from VCT and numerical solutions is -0.18% with a standard deviation of 5.05%. The proposed technique using vibration data in the tensile loading region has proven to be an accurate and reliable method which might be used to identify the buckling load of plates. Unlike other static methods, this correlation approach does not require drawing lines in the pre-buckling and post-buckling regions; thus, bias in data interpretation is avoided.

An Experiment on Verification of Multi-Gas Tracer Technique for Air Exchange Rate Between Rooms (실간환기량 측정을 위한 멀티추적가스법의 검증실험)

  • Han, Hwa-Taik;Cho, Seok-Hyo
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.99-104
    • /
    • 2007
  • Tracer gas technique is widely used to measure the ventilation rates and/or ventilation effectiveness of building spaces. However, the conventional method using a single tracer gas can measure only outdoor air change rates in a single zone. This paper deals with the multi-gas tracer technique to measure air exchange rates between rooms. Interzonal air movements are important to characterize overall ventilation performance of complicated multi-zone buildings. Experiments are conducted in a simple two-room model with known airflow rates using tracer gases of SF6 and R134a. The concentration decays of two tracer gases are measured after simultaneous injections in each room. The governing equations are derived from the continuity and the mass balance of each room. The data reduction procedure are developed to obtain the inter-room airflow rates using the governing matrix inversion, and various data manipulation methods are tested, such as data shift, interpolation, smoothing, and etc, to improve the estimate and interpretation of the results.

  • PDF

Estimation of Phosphorus Concentration in Silicon Thin Film on Glass Using ToF-SIMS

  • Hossion, M. Abul;Murukesan, Karthick;Arora, Brij M.
    • Mass Spectrometry Letters
    • /
    • v.12 no.2
    • /
    • pp.47-52
    • /
    • 2021
  • Evaluating the impurity concentrations in semiconductor thin films using time of flight secondary ion mass spectrometry (ToF-SIMS) is an effective technique. The mass interference between isotopes and matrix element in data interpretation makes the process complex. In this study, we have investigated the doping concentration of phosphorus in, phosphorus doped silicon thin film on glass using ToF-SIMS in the dynamic mode of operation. To overcome the mass interference between phosphorus and silicon isotopes, the quantitative analysis of counts to concentration conversion was done following two routes, standard relative sensitivity factor (RSF) and SIMetric software estimation. Phosphorus doped silicon thin film of 180 nm was grown on glass substrate using hot wire chemical vapor deposition technique for possible applications in optoelectronic devices. Using ToF-SIMS, the phosphorus-31 isotopes were detected in the range of 101~104 counts. The silicon isotopes matrix element was measured from p-type silicon wafer from a separate measurement to avoid mass interference. For the both procedures, the phosphorus concentration versus depth profiles were plotted which agree with a percent difference of about 3% at 100 nm depth. The concentration of phosphorus in silicon was determined in the range of 1019~1021 atoms/cm3. The technique will be useful for estimating distributions of various dopants in the silicon thin film grown on glass using ToF-SIMS overcoming the mass interference between isotopes.

A study on the Counseling Process and Counseling Techniques Applying Freud's Psychoanalysis (프로이트 정신분석을 적용한 상담과정과 상담기법에 관한 연구)

  • Lee, Pyung-Hwa;Kim, Bo-Ki
    • Industry Promotion Research
    • /
    • v.7 no.2
    • /
    • pp.51-58
    • /
    • 2022
  • This study is based on Freud's psychoanalysis and intends to deal with the actual psychoanalytic counseling applied to it. In particular, I would like to study the counseling process and counseling techniques. The research results are as follows. The counseling process goes through four stages: initiation, transfer development, training, and transfer resolution as follows after selecting a client and constructing a counseling situation. In the beginning phase, the client listens to important past histories. In the metastasis development stage, it is from the time when metastasis appears. The training phase is the phase in which the client's insight is translated into real life to bring about change. The transfer resolution stage is the period when transfer analysis and interpretation are completed. Counseling techniques include free association, empathy, resistance, transference and countertransference, and interpretation. Free association is a key technique in psychoanalytic therapy and plays an important role in maintaining the analytical framework. Empathy is the ability of the therapist to identify herself with the client and the ability of the therapist to convey the empathic experience to the client itself is a key mechanism for change. Resistance refers to any behavior in which the client does not cooperate with counseling. Transference and countertransference are the main techniques of psychoanalysis. This is because the psychoanalyst induces and resolves the transference of the client during the treatment process. Interpretation refers to the technique of responding verbally in order to understand the needs, meanings, and motives hidden behind the client's thoughts, feelings, and actions. In conclusion, the counseling process of psychoanalytic counseling refers to the purpose of effective counseling by selecting a client and constructing a counseling situation. In addition, the principles of psychoanalysis in counseling techniques are applied to treatment procedures that vary according to the nature of the case, and can be variably applied while treating the same client.

Impulse Response Filtration Technique for the Determination of Phase Velocities from SASW Measurements (SASW시험에 의한 위상속도 결정을 위한 임펄스 응답필터 기법)

  • ;Stokoe, K.H., Il
    • Geotechnical Engineering
    • /
    • v.13 no.1
    • /
    • pp.111-122
    • /
    • 1997
  • The calculation of phase velocities in Spectral-Analysis -of-Surface -Waves (SASW) meas urements requires unwrapping phase angles. In case of layered systems with strong stiffness contrast like a pavement system, conventional phase unwrapping algorithm to add in teger multiples of 2n to the principal value of a phase angle may lead to wrong phase volocities. This is because there is difficulty in counting the number of jumps in the phase spectrum especially at the receiver spacing where the measurements are in the transition Bone of defferent modes. A new phase interpretation scheme, called "Impulse Response Fil traction ( IRF) Technique," is proposed, which is based on the separation of wave groups by the filtration of the impulse response determinded between two receivers. The separation of a wave group is based on the impulse response filtered by using information from Gabor spectrogram, which visualizes the propagation of wave groups at the frequency -time space. The filtered impulse response leads to clear interpretation of phase spectrum, which eliminates difficulty in counting number of jumps in the phase spectrum. Verification of the IRF technique was performed by theoretical simulation of the SASW measurement on a pavement system which complicates wave propagation.opagation.

  • PDF

Gravity Field Interpretation and Underground Structure Modelling as a Method of Setting Horizontal and Vertical Zoning of a Active Fault Core (활성단층의 3차원적인 규모를 결정하기 위한 중력장 데이터의 해석 및 지각구조 모델링: 양산단층에서의 예)

  • Choi, Sungchan;Kim, Sung-Wook;Choi, Eun-Kyeong;Lee, Young-Cheol;Ha, Sangmin
    • Economic and Environmental Geology
    • /
    • v.54 no.1
    • /
    • pp.91-103
    • /
    • 2021
  • In order to estimate the vertical and horizontal structural in the Yangsan fault core line (Naengsuri area, Pohang), we carried out gravity field measurements and interpretation procedures such as Euler deconvolution method and curvature analysis in addition to the forward modelling technique (i.e. IGMAS+). We found a prominent gravity difference of more than 1.5 mGal across the fault core. This indicates a distinct density difference between the western and eastern crustal area across the Yangsan fault line. Comparing this gravity field interpretation with other existent geologic and geophysical survey data (e.g. LiDAR, trenching, electric resistivity measurements), It is concluded that (1) the prominent gravity difference is caused by the density difference of about 0.1 g/㎤ between the Bulguksa Granite in the west and the Cretaceous Sandstone in the east side, (2) the fault core is elongated vertically into a depth of about 2,000 meters and extended horizontally 3,000 meters to the NNE direction from Naengsuri area. Our results present that the gravity field method is a very effective tool to estimate a three -dimensional image of the active fault core.

The usability analysis of the Ray-sum technique and SSD (Shaded Surface display) technique in stomach CT Scan (위장 CT 검사에서 Ray-sum 기법과 SSD(Shaded Surface Display) 기법의 유용성 분석)

  • Kim, Hyun-Joo;Cho, Jae-Hwan;Song, Hoon
    • Journal of Digital Contents Society
    • /
    • v.12 no.2
    • /
    • pp.151-156
    • /
    • 2011
  • The analysis and image evaluation the Ray-sum technique and Shaded Surface Display (under SSD) technique which is the reconstruction image processing technique after the CT scan was evaluated and the usability of the three-dimensional information offering was confirmed in the patient with stomach cancer. After obtaining the raw data by using 64-MDCT in 20 patient with stomach cancers, the image reconstruction processing was done. It was evaluated to describe accurately the analyzed result Ray-sum and SSD reconstruction image everyone anatomical structure. In the precision estimation of the image, the lesion location could coincide in the Ray-sum and SSD reconstruction image majority with the gastro fiberscope and we can know than the gastro fiberscope over 6cm that there was the error. In addition, We could know that degree of accordance of the results of the image interpretation about the lesion and endoscope and pathological opinion were high.