• Title/Summary/Keyword: internal dose assessment

Search Result 103, Processing Time 0.023 seconds

Comparative Analyses of the Internal Radiation Exposures due to Food Chain Pathway Using FOOD III Code (FOOD III 코드를 이용한 섭식경로 내부피폭 비교해석)

  • Choi, Yong-Ho;Chung, Kyu-Hoi;Kim, Jin-Kyu;Lee, Jeong-Ho
    • Journal of Radiation Protection and Research
    • /
    • v.13 no.2
    • /
    • pp.41-51
    • /
    • 1988
  • In order to develop a food-chain computer code suitable to the environmental conditions of Korea, the FOOD III code was partially modified. The excution results for Korean male-adult were compared to those from the Canadian version of FOOD III to deduce a more realistic approach in dose assessment. The amounts of Mn-54, Co-58, Co-60, I-131 and I-132 released from Kori unit 1 in1984 were used as the source terms for the sample calculation. The maximum atmospheric dispersion factor(X/Q) value on the site boundary was applied. Through the code modification, organ doses decreased by about $20{\sim}70%$ and the effective committed dose equivalent by about 40% to be $7.935{\times}10^{-6}Sv/y$ which is 0.16% of the ICRP limit, $5{\times}10^{-3}Sv/y$.

  • PDF

Role of Krebs von den Lungen-6 (KL-6) in Assessing Hypersensitivity Pneumonitis

  • Mostafa, Amira Ismail;Salem, Ayman Elsayed;Ahmed, Heba Allah Moussa;Bayoumi, Aml Ibrahim;Halim, Radwa M. Abdel;Samie, Rasha M. Abdel
    • Tuberculosis and Respiratory Diseases
    • /
    • v.84 no.3
    • /
    • pp.200-208
    • /
    • 2021
  • Background: Hypersensitivity pneumonitis (HP) is an increasingly recognized form of diffuse parenchymal lung disease. Krebs von den Lungen-6 (KL-6) is now classified as a human MUC1 mucin protein, and regenerating type II pneumocytes are the primary cellular source of KL-6/MUC1 in the affected lungs of patients with interstitial lung diseases (ILD). Serum KL-6/MUC1 levels have been demonstrated to be useful for the evaluation of various ILD. To determine the role of circulating KL-6 in evaluating the disease activity and management of HP. Methods: An observational cross-sectional study was conducted on 51 patients with HP and 20 healthy controls. Serum KL-6 levels were measured in both groups. Patients were further assessed based on chest high-resolution computed tomography (HRCT), pulmonary function test, 6-minute walk test, echocardiography, bronchioalveolar lavage, and/or transbronchial biopsy. Patients were divided into the fibrotic and non-fibrotic groups according to the HRCT findings. Results: The median serum KL-6 levels were significantly higher in HP patients as compared to the control group. The median serum KL-6 levels were found to be higher in the non-fibrotic HP group (1,900 IU/mL) as compared to the fibrotic group (1,200 IU/mL). There was a significant inverse correlation between serum KL-6 serum level and the dose of steroids as well as the duration of steroid therapy. Conclusion: The presence of higher KL-6 levels in the non-fibrotic HP group implies its enhanced production by regenerating pneumocytes in response to alveolar injury. The significant association between serum KL-6 levels and the dose and the duration of steroid therapy emphasizes the significant role of steroids in the stabilization of the disease.

An Open-Label, Multicentre, Observational, Post-Marketing Study to Monitor the Safety and Effectiveness of Umeclidinium/Vilanterol in Korean Patients

  • Eun-Yeong Cho;Jung-Eun Cho;Eun-Bin Lee;Seung Soo Yoo;Jung Hyun Chang
    • Tuberculosis and Respiratory Diseases
    • /
    • v.86 no.1
    • /
    • pp.33-46
    • /
    • 2023
  • Background: Umeclidinium/vilanterol (UMEC/VI; ANORO ELLIPTA, GSK) is a commonly used dual bronchodilator. This study evaluated the safety and effectiveness of UMEC/VI in Korean patients with chronic obstructive pulmonary disease (COPD) over a 6-year period. Methods: This was an open-label, multicentre, observational, post-marketing surveillance study. A total of 3,375 patients were enrolled consecutively in 52 hospitals, by 53 physicians, between July 2014 and July 2020. Patients who were administered UMEC/VI (fixed-dose 62.5 ㎍/25 ㎍) at least once and were monitored for safety and effectiveness were included in the analysis. Incidence and severity of adverse events (AEs) reported after administrating at least one dose of UMEC/VI were monitored, including unexpected adverse events (UAEs) and adverse drug reactions (ADRs). Effectiveness of UMEC/VI after 24 weeks of administration was also assessed using physician's evaluation (effective, ineffective/no change, worsening, indeterminable) and lung function improvement. Results: Of 3,375 patients, 3,086 were included in the safety assessment group (mean age±standard deviation: 69.76±8.80 years; 85.9% male [n=2,652]; 73.1% aged ≥65 years [n=2,255]). The overall incidence of AEs was 28.8% (n=890), of which 2.2% (n=67) were ADRs. Serious AEs and UAEs were reported in 181 (5.9%) and 665 (21.6%) patients, respectively, and two patients (<0.1%) reported unexpected severe ADR. Of the 903/3,086 patients analysed for effectiveness, most (82.8%, n=748) showed overall disease improvement after UMEC/VI treatment. Conclusion: This study confirmed UMEC/VI administered to Korean patients according to the prescribing information was well-tolerated and can be considered an effective option for COPD treatment.

The Determination of Radon Progeny Concentration in Controlled Radon Environment (라돈을 제어하는 환경에서 라돈 자핵종의 농도 결정)

  • Seo, Kyung-Won;Lee, Byung-Kee
    • Journal of Radiation Protection and Research
    • /
    • v.18 no.1
    • /
    • pp.37-51
    • /
    • 1993
  • A standard radon chamber and a radon generator adjusted by ventilation system which had used in this research were assumed to calculate theoretically the concentration of radon progeny using Jacobi model theory. On the one hand, the filter sampled from the radon standard chamber and the radon generator was measured and analysed by the alpha spectrometry method. It is clear that measured result shows a good agreement with theoretical result. Therefore, it is observed that this research can made a great contribution to more accurate internal dose assessment by alpha emission of radon progeny in indoor radon environment, and fast individual measurement and determination of concentration for radon progeny.

  • PDF

Correct Use of Inhalers in Patients with Obstructive Pulmonary Disease (폐쇄성 폐질환자의 흡입기 사용 정확성 정도)

  • Lee, Jong-Kyung;Yang, Young-Hee
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.16 no.1
    • /
    • pp.111-120
    • /
    • 2010
  • Purpose: The purpose of this study was to evaluate the correct use of inhalers and to examine the patients characteristics affecting correct use of inhalers in patients with obstructive pulmonary disease. Method: Subjects were 280 patients with obstructive pulmonary disease who visited the internal pulmonary outpatient departments in 2 university hospitals in Korea. Inhaler use of each patient was assessed using a checklist recommended by the National Asthma Education and Prevention Program Expert Panel. Result: Most subjects used a DPI or MDI. The overall mean score of correct use was 72.09. Most subjects responded they knew well how to use their inhalers. Most frequent error was 'not fully exhaling before inhalation'. A younger age, higher educational level, living with family, and awareness of inhaler use were significantly associated with correct use of inhalers. Conclusion: The findings of this study showed that most of patients were unable to use inhalers correctly even though they had prior educational experiences. Regular assessing of inhaler use and adequate inhaler education considering patients characteristics by nurses are needed.

Performance assessment of HEPA filter against radioactive aerosols from metal cutting during nuclear decommissioning

  • Lee, Min-Ho;Yang, Wonseok;Chae, Nakkyu;Choi, Sungyeol
    • Nuclear Engineering and Technology
    • /
    • v.52 no.5
    • /
    • pp.1043-1050
    • /
    • 2020
  • Radioactive aerosols are produced during the cutting of contaminated and activated metals. They must be collected and removed by a high-performing filtration system before releasing to the environment from the decommissioning workplace. The filtration system requires regular replacement to ensure the sufficient removal of radioactive aerosols because its filtration efficiency gradually decreases. This study evaluates the efficiency and lifetime of filters while cutting metals by using a plasma arc cutter. Particularly, this study considers the aerodynamic diameter distribution of number and mass concentrations for aerosols from 6 nm to 10 ㎛ when evaluating the performance of filters. After 20 time reuses for cutting operation performed in a cutting chamber, the removal efficiency is reduced from over 99 to below 93% at 2 ㎛. The results are used to analyze the lifetime of filters, the frequencies of their replacements, and impact on internal radiation dose.

Image-Based Assessment and Clinical Significance of Absorbed Radiation Dose to Tumor in Repeated High-Dose $^{131}I$ Anti-CD20 Monoclonal Antibody (Rituximab) Radioimmunotherapy for Non-Hodgkin's Lymphoma (반복적인 $^{131}I$ rituximab 방사면역치료를 시행 받은 비호지킨 림프종 환자 군에서 종양 부위의 영상기반 방사선 흡수선량 평가와 임상적 의의)

  • Byun, Byung-Hyun;Kim, Kyeong-Min;Woo, Sang-Keun;Choi, Tae-Hyun;Kang, Hye-Jin;Oh, Dong-Hyun;Kim, Byeong-Il;Cheon, Gi-Jeong;Choi, Chang-Woon;Lim, Sang-Moo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.1
    • /
    • pp.60-71
    • /
    • 2009
  • Purpose: We assessed the absorbed dose to the tumor ($Dose_{tumor}$) by using pretreatment FDG-PET and whole-body (WB) planar images in repeated radioimmunotherapy (RIT) with $^{131}I$ rituximab for NHL. Materials and Methods: Patients with NHL (n=4) were administered a therapeutic dose of $^{131}I$ rituximab. Serial WB planar images alter RIT were acquired and overlaid to the coronal maximum intensity projection (MIP) PET image before RIT. On registered MIP PET and WB planar images, 2D-ROls were drawn on the region of tumor (n=7) and left medial thigh as background, and $Dose_{tumor}$ was calculated. The correlation between $Dose_{tumor}$ and the CT-based tumor volume change alter RIT was analyzed. The differences of $Dose_{tumor}$ and the tumor volume change according to the number of RIT were also assessed. Results: The values of absorbed dose were $397.7{\pm}646.2cGy$ ($53.0{\sim}2853.0cGy$). The values of CT-based tumor volume were $11.3{\pm}9.1\;cc$ ($2.9{\sim}34.2cc$), and the % changes of tumor volume before and alter RIT were $-29.8{\pm}44.3%$ ($-100.0%{\sim}+42.5%$), respectively. $Dose_{tumor}$ and the tumor volume change did not show the linear relationship (p>0.05). $Dose_{tumor}$ and the tumor volume change did not correlate with the number of repeated administration (p>0.05). Conclusion: We could determine the position and contour of viable tumor by MIP PET image. And, registration of PET and gamma camera images was possible to estimate the quantitative values of absorbed dose to tumor.

Image Evaluation and Exposure Dose with the Application of Tube Voltage and Adaptive Statistical Iterative Reconstruction of Low Dose Computed Tomography (저 선량 전산화단층촬영의 관전압과 적응식 통계적 반복 재구성법 적용에 따른 영상평가 및 피폭선량)

  • Moon, Tae-Joon;Kim, Ki-Jeong;Lee, Hye-Nam
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.261-267
    • /
    • 2017
  • The study has attempted to evaluate and compare the image evaluation and exposure dose by respectively applying filter back projection (FBP), the existing test method, and adaptive statistical iterative reconstruction (ASIR) with different values of tube voltage during the low dose computed tomography (LDCT). With the image reconstruction method as basis, chest phantom was utilized with the FBP and ASIR set at 10%, 20% respectively, and the change of tube voltage (100 kVp, 120 kVp). For image evaluation, back ground noise, signal-noise ratio (SNR) and contrast-noise ratio (CNR) were measured, and, for dose assessment, CTDIvol and DLP were measured respectively. In terms of image evaluation, there was significant difference in ascending aorta (AA) SNR and inpraspinatus muscle (IM) SNR with the different amount of tube voltage (p < 0.05). In terms of CTDIvol, the measured values with the same tube voltage of 120 kVp were 2.6 mGy with no-ASIR and 2.17 mGy with 20%-ASIR respectively, decreased by 0.43 mGy, and the values with 100 kVp were 1.61 mGy with no-ASIR and 1.34 mGy with 20%-ASIR, decreased by 0.27 mGy. In terms of DLP, the measured values with 120 kVp were $103.21mGy{\cdot}cm$ with no-ASIR and $85.94mGy{\cdot}cm$ with 20%-ASIR, decreased by $17.27mGy{\cdot}cm$ (about 16.7%), and the values with 100 kVp were $63.84mGy{\cdot}cm$ with no-ASIR and $53.25mGy{\cdot}cm$ with 20%-ASIR, a decrease by $10.62mGy{\cdot}cm$ (about 16.7%). At lower tube voltage, the rate of dose significantly decreased, but the negative effects on image evaluation was shown due to the increase of noise.

Safety Evaluation of Clearance of Radioactive Metal Waste After Decommissioning of NPP (원전해체후 규제해제 대상 금속폐기물에 대한 자체처분 안전성 평가)

  • Choi, Young-Hwan;Ko, Jae-Hun;Lee, Dong-Gyu;Hwang, Young-Hwan;Lee, Mi-Hyun;Lee, Ji-Hoon;Hong, Sang-Bum
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.18 no.2_spc
    • /
    • pp.291-303
    • /
    • 2020
  • The Kori-Unit 1 nuclear power plant, which is scheduled to be decommissioned after permanent shutdown, is expected to generate large amounts of various types of radioactive waste during the decommissioning process. Among these, nuclear reactors and internal structures have high levels of radioactivity and the dismantled structure must have the proper size and weight on the primary side. During decommissioning, it is important to prepare an appropriate and efficient disposal method through analysis of the disposal status and the legal restrictions on wastes generated from the reactors and internal structures. Nuclear reactors and internal structures generate radioactive wastes of various levels, such as medium, very low, and clearance. A radiation evaluation indicates that wastes in the clearance level are generated in the reactor head and upper head insulation. In this study, a clearance waste safety evaluation was conducted using the RESRAD-RECYCLE code, which is a safety evaluation code, based on the activation evaluation results for the clearance level wastes. The clearance scenario for the target radioactive waste was selected and the maximum individual and collective exposure doses at the time of clearance were calculated to determine whether the clearance criteria limit prescribed by the Nuclear Safety Act was satisfied. The evaluation results indicated that the doses were significantly low, and the clearance criteria were satisfied. Based on the safety assessment results, an appropriate metal recycle and disposal method were suggested for clearance, which are the subject of the deregulation of internal structures of nuclear power plant.

A Study on $^{99m}Tc$-pertechnetate thyroid uptake in various thyroid diseases (각종(各種) 갑상선질환(甲狀腺疾患)의 $^{99m}Tc$-pertechnetate 갑상선섭취(甲狀腺攝取)에 관(關)한 연구(硏究))

  • Choi, Sung-Jae;Min, Hae-Sook;Koh, Chang-Soon;Lee, Mun-Ho
    • The Korean Journal of Nuclear Medicine
    • /
    • v.8 no.1_2
    • /
    • pp.29-37
    • /
    • 1974
  • The $^{99m}Tc$-pertechnetate thyroid uptake rates(20 min) were measured in 24 healthy normal subjects, 140 patients with nontoxic goiter and 98 patients with thyrotoxicosis who were treated at the Thyroid Clinic, Seoul National University Hospital, from August 1972 to August 1973. Diagnostic reliabilities and correlations between $^{99m}TcO_4$-thyroid uptake rate (20 min) and other thyroid function tests were evaluated. The observed results were as follows 1. The $^{99m}TcO_4$-thyroid uptake rates (20 min) in normal subjects, euthyroid group and hyperthyroid group were $4.1{\pm}0.9%,\;5.2{\pm}1.8%\;and\;29.7{\pm}10.6%$. There was a significant difference between the mean of the euthyroid group and the mean of the hyperthyroid group and so differentiation between them can be easy. 2. In the diagnosis of hyperthyroidism, the reliabilities of $^{99m}TcO_4$- thyroid uptake rate(20 min), $^{131}I$ thyroid uptake rate(24hrs), serum $T_3$ resin uptake rate, serum $T_4\;and\;T_7\;were\;87.9{\sim}97.9%,\;81.2{\sim}94.4%,\;87.9{\sim}97.9%,\;90.5{\sim}99.3%\;and\;93.7{\sim}100%$. $^{99m}TcO_4$-thyroid uptake rate(20 min) is more accurate than $^{131}I$ thyroid uptake rate (24 hrs) in the diagnosis of hyperthyroidism. 3. $^{99m}TcO_4$-thyroid uptake rate (20 min) was well correlated with $^{131}I$ thyroid uptake rate (24 hrs), serum $T_3$ resin uptake rate, serum $T_4\;and\;T_7$. Points in favor of $^{99m}Tc$ are that it gives a small radiation dose to the thyroid, that tests can be repeated at the short interval, the study can be completed at a single patient visit and it is particularly well suited for the assessment of thyroid function in patients being treated with an antithyroid drug.

  • PDF