• Title/Summary/Keyword: interleaving

Search Result 257, Processing Time 0.028 seconds

Efficient Transmission of Scalable Video Streams Using Dual-Channel Structure (듀얼 채널 구조를 이용한 Scalable 비디오(SVC)의 전송 성능 향상)

  • Yoo, Homin;Lee, Jaemyoun;Park, Juyoung;Han, Sanghwa;Kang, Kyungtae
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.2 no.9
    • /
    • pp.381-392
    • /
    • 2013
  • During the last decade, the multitude of advances attained in terminal computers, along with the introduction of mobile hand-held devices, and the deployment of high speed networks have led to a recent surge of interest in Quality of Service (QoS) for video applications. The main difficulty is that mobile devices experience disparate channel conditions, which results in different rates and patterns of packet loss. One way of making more efficient use of network resources in video services over wireless channels with heterogeneous characteristics to heterogeneous types of mobile device is to use a scalable video coding (SVC). An SVC divides a video stream into a base layer and a single or multiple enhancement layers. We have to ensure that the base layer of the video stream is successfully received and decoded by the subscribers, because it provides the basis for the subsequent decoding of the enhancement layer(s). At the same time, a system should be designed so that the enhancement layer(s) can be successfully decoded by as many users as possible, so that the average QoS is as high as possible. To accommodate these characteristics, we propose an efficient transmission scheme which incorporates SVC-aware dual-channel repetition to improve the perceived quality of services. We repeat the base-layer data over two channels, with different characteristics, to exploit transmission diversity. On the other hand, those channels are utilized to increase the data rate of enhancement layer data. This arrangement reduces service disruption under poor channel conditions by protecting the data that is more important to video decoding. Simulations show that our scheme safeguards the important packets and improves perceived video quality at a mobile device.

Trend of SiC Power Semiconductor (탄화규소(SiC) 반도체소자의 동향)

  • Kim, Sang-Cheol;Bahng, Wook;Seo, Kil-Soo;Kim, Kee-Hyun;Kim, Hyung-Woo;Kim, Nam-Kyun;Kim, Eun-Dong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.7-12
    • /
    • 2004
  • 탄화규소 전력반도체 소자는 실리콘 전력반도체 소자에 비해 우수한 물질특성을 갖고 있어 성능 측면에서 뿐 만 아니라 전력변환장비의 크기를 획기적으로 줄일 수 있는 새로운 반도체 소자이다. 특히 unipolar 계열의 소자에서 괄목할 만한 특성을 보이고 있다. 현재 쇼트키 장벽 다이오드의 경우 5kV급, UMOSFET의 경우 3kV급의 소자까지 보고되고 있으며 반도체 물질 중에서 가장 활발히 연구가 진행되고 있는 분야 중의 하나이다. 단결정성장 분야에서도 3인치 급이 상용화 되었으며 4인치 크기의 웨이퍼의 상용화가 조만간 실현될 것으로 기대되고 있다. 이러한 기술적 발전을 토대로 600V, 1200V급 쇼트키 다이오드가 PFC boost 용으로 시판되고 있으나 아직은 다른 반도체 소자에 비해 미미한 실정이다. 현재에는 $250^{\circ}C$까지의 온도영역에서 실리콘 SOI(Silicon on Insulator) 소자가 주로 사용되고 있다. 그러나 $300^{\circ}C$를 넘는 온도 영역에서는 실리콘으로는 한계가 있고, 특히 SOI는 전력소자에 적용하기는 한계가 있어 주로 저전력 고온소자가 필요한 부분에 적용이 되고 있다. 따라서 전력용에 적합한 고온소자로 탄화규소 소자의 연구가 활발히 진행되고 있다. 현재의 추세로 보아 $200-300^{\circ}C$ 영역의 응용분야에서는 SOI와 탄화규소가 함께 적용될 것으로 예상되며, $300^{\circ}C$를 넘는 온도영역에서는 탄화규소 소자의 우월적 지위가 예상된다. 이러한 이유로 탄화규소 반도체소자의 응용 분야는 크게 확대될 것으로 예상되며 국가적 차원의 지원 및 육성이 요구되는 분야 중의 하나이다.t로 사용한 소자보다 발광 소광 현상이 적게 일어난 것에 기인하였다고 생각된다. 두 소자 모두 $40mA/cm^2$ 에서 이상적인 화이트 발란스와 같은(0.33,0.33)의 색좌표를 보였다.epsilon}_0=1345$의 빼어난 압전 및 유전특성과 $330^{\circ}C$의 높은 $T_c$를 보였고 그 조성의 vibration velocity는 약4.5 m/s로 나타났다.한 관심이 높아지고 있다. 그러나 고 자장 영상에서의 rf field 에 의한 SAR 증가는 중요한 제한 요소로 부각되고 있다. 나선주사영상은 SAR 문제가 근원적으로 발생하지 않고, EPI에 비하여 하드웨어 요구 조건이 낮아 고 자장에서의 고속영상방법으로 적합하다. 본 논문에서는 고차 shimming 을 통하여 불균일도를 개선하고, single shot 과 interleaving 을 적용한 multi-shot 나선주사영상 기법으로 $100{\times}100$에서 $256{\times}256$의 고해상도 영상을 얻어 고 자장에서 초고속영상기법으로 다양한 적용 가능성을 보였다. 연구에서 연구된 $[^{18}F]F_2$가스는 친핵성 치환반응으로 방사성동위원소를 도입하기 어려운 다양한 방사성의 약품개발에 유용하게 이용될 수 있을 것이다.었으나 움직임 보정 후 영상을 이용하여 비교한 경우, 결합능 변화가 선조체 영역에서 국한되어 나타나며 그 유의성이 움직임 보정 전에 비하여 낮음을 알 수 있었다. 결론: 뇌활성화 과제 수행시에 동반되는 피험자의 머리 움직임에 의하여 도파민 유리가 과대평가되었으며 이는 이 연구에서 제안한 영상정합을 이용한 움직임 보정기

  • PDF

Design of Low Power 4th order ΣΔ Modulator with Single Reconfigurable Amplifier (재구성가능 연산증폭기를 사용한 저전력 4차 델타-시그마 변조기 설계)

  • Sung, Jae-Hyeon;Lee, Dong-Hyun;Yoon, Kwang Sub
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.5
    • /
    • pp.24-32
    • /
    • 2017
  • In this paper, a low power 4th order delta-sigma modulator was designed with a high resolution of 12 bits or more for the biological signal processing. Using time-interleaving technique, 4th order delta-sigma modulator was designed with one operational amplifier. So power consumption can be reduced to 1/4 than a conventional structure. To operate stably in the big difference between the two capacitor for kT/C noise and chip size, the variable-stage amplifier was designed. In the first phase and second phase, the operational amplifier is operating in a 2-stage. In the third and fourth phase, the operational amplifier is operating in a 1-stage. This was significantly improved the stability of the modulator because the phase margin exists within 60~90deg. The proposed delta-sigma modulator is designed in a standard $0.18{\mu}m$ CMOS n-well 1 poly 6 Metal technology and dissipates the power of $354{\mu}W$ with supply voltage of 1.8V. The ENOB of 11.8bit and SNDR of 72.8dB at 250Hz input frequency and 256kHz sampling frequency. From measurement results FOM1 is calculated to 49.6pJ/step and FOM2 is calculated to 154.5dB.

High-resolution Spiral-scan Imaging at 3 Tesla MRI (3.0 Tesla 자기공명영상시스템에서 고 해상도 나선주사영상)

  • Kim, P.K.;Lim, J.W.;Kang, S.W.;Cho, S.H.;Jeon, S.Y.;Lim, H.J.;Park, H.C.;Oh, S.J.;Lee, H.K.;Ahn, C.B.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.10 no.2
    • /
    • pp.108-116
    • /
    • 2006
  • Purpose : High-resolution spiral-scan imaging is performed at 3 Tesla MRI system. Since the gradient waveforms for the spiral-scan imaging have lower slopes than those for the Echo Planar Imaging (EPI), they can be implemented with the gradient systems having lower slew rates. The spiral-scan imaging also involves less eddy currents due to the smooth gradient waveforms. The spiral-scan imaging method does not suffer from high specific absorption rate (SAR), which is one of the main obstacles in high field imaging for rf echo-based fast imaging methods such as fast spin echo techniques. Thus, the spiral-scan imaging has a great potential for the high-speed imaging in high magnetic fields. In this paper, we presented various high-resolution images obtained by the spiral-scan methods at 3T MRI system for various applications. Materials and Methods : High-resolution spiral-scan imaging technique is implemented at 3T whole body MRI system. An efficient and fast higher-order shimming technique is developed to reduce the inhomogeneity, and the single-shot and interleaved spiral-scan imaging methods are developed. Spin-echo and gradient-echo based spiral-scan imaging methods are implemented, and image contrast and signal-tonoise ratio are controlled by the echo time, repetition time, and the rf flip angles. Results : Spiral-scan images having various resolutions are obtained at 3T MRI system. Since the absolute magnitude of the inhomogeneity is increasing in higher magnetic fields, higher order shimming to reduce the inhomogeneity becomes more important. A fast shimming technique in which axial, sagittal, and coronal sectional inhomogeneity maps are obtained in one scan is developed, and the shimming method based on the analysis of spherical harmonics of the inhomogeneity map is applied. For phantom and invivo head imaging, image matrix size of about $100{\times}100$ is obtained by a single-shot spiral-scan imaging, and a matrix size of $256{\times}256$ is obtained by the interleaved spiral-scan imaging with the number of interleaves of from 6 to 12. Conclusion : High field imaging becomes increasingly important due to the improved signal-to-noise ratio, larger spectral separation, and the higher BOLD-based contrast. The increasing SAR is, however, a limiting factor in high field imaging. Since the spiral-scan imaging has a very low SAR, and lower hardware requirements for the implementation of the technique compared to EPI, it is suitable for a rapid imaging in high fields. In this paper, the spiral-scan imaging with various resolutions from $100{\times}100$ to $256{\times}256$ by controlling the number of interleaves are developed for the high-speed imaging in high magnetic fields.

  • PDF

A Study on Batch-Type Remote Plasma Dry Cleaning Process for Native Oxide Removal (배치식 플라즈마 세정 설비를 이용한 자연산화막 제거 공정)

  • Park, Jae-Young;Yi, Wook-Yeol;Hyung, Yong-Woo;Nam, Seok-Woo;Lee, Hyeon-Deok;Song, Chang-Lyong;Kang, Ho-Kyu;Roh, Yong-Han
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.247-251
    • /
    • 2004
  • 반도체 소자의 제조에 있어 실리콘 표면에 성장한 자연산화막을 제거하기 위해 일반적으로 습식 세정 기술이 이용되어 왔다. 하지만 소자의 최소 선폭(design rule)이 nano급으로 고집적화 됨에 따라 contact hole 바닥의 자연산화막을 깨끗이 제거하는데 있어서 그 한계를 나타나고 있다. 이에 대한 효과적인 대안 공정으로 가스 건식 세정 기술이 연구되고 있다. 본 논문에서는 한 번에 50매 이상의 웨이퍼를 처리함으로써 생산성 측면에서 월등한 배치식 설비에서 원거리 플라즈마(remote plasma) 장치에서 2.450Hz의 마이크로웨이브(${\mu}$-wave)에 의해 형성시킨 수소라디칼과 $NF_3$ 가스를 이용하여 실리콘에 결함을 주지 않고 자연산화막을 선택적으로 제거하는 공정에 대해 고찰하였다. AFM을 이용한 표면분석, TEM을 이용한 물성분석, 그리고 ToF-SIMS 및 XPS를 이용한 화학 분석을 습식 및 건식 세정을 비교 평가한 결과, 건식 세정 공정이 실리콘 표면에 결함을 주지 않고 자연산화막을 제거 할 수 있음을 확인하였다. 산화막$(SiO_2)$, 질화막$(Si_3N_4)$, 그리고 다결정 실리콘(Poly-Si) 등의 각 막질별 식각 특성을 고찰하였으며, $NH_3$의 캐리어 가스인 $N_2$의 주입량을 조절함으로써 수소라디칼 형성 효율의 개선이 가능하였으며, 이로부터 게이트와 소스/드레인 사이를 절연하기 위해 이용되는 질화막의 식각 선택비를 2배 정도 개선할 수 있었다. nano급 소자에 실장하여 평가한 결과에서 불산(HF)에 의한 습식 세정 방식에 비하여 약 $20{\sim}50%$ 정도의 contact 저항 감소 효과가 있음이 확인되었다.두 소자 모두 $40mA/cm^2$ 에서 이상적인 화이트 발란스와 같은(0.33,0.33)의 색좌표를 보였다.epsilon}_0=1345$의 빼어난 압전 및 유전특성과 $330^{\circ}C$의 높은 $T_c$를 보였고 그 조성의 vibration velocity는 약4.5 m/s로 나타났다.한 관심이 높아지고 있다. 그러나 고 자장 영상에서의 rf field 에 의한 SAR 증가는 중요한 제한 요소로 부각되고 있다. 나선주사영상은 SAR 문제가 근원적으로 발생하지 않고, EPI에 비하여 하드웨어 요구 조건이 낮아 고 자장에서의 고속영상방법으로 적합하다. 본 논문에서는 고차 shimming 을 통하여 불균일도를 개선하고, single shot 과 interleaving 을 적용한 multi-shot 나선주사영상 기법으로 $100{\times}100$에서 $256{\times}256$의 고해상도 영상을 얻어 고 자장에서 초고속영상기법으로 다양한 적용 가능성을 보였다. 연구에서 연구된 $[^{18}F]F_2$가스는 친핵성 치환반응으로 방사성동위원소를 도입하기 어려운 다양한 방사성의 약품개발에 유용하게 이용될 수 있을 것이다.었으나 움직임 보정 후 영상을 이용하여 비교한 경우, 결합능 변화가 선조체 영역에서 국한되어 나타나며 그 유의성이 움직임 보정 전에 비하여 낮음을 알 수 있었다. 결론: 뇌활성화 과제 수행시에 동반되는 피험자의 머리 움직임에 의하여 도파민 유리가 과대평가되었으며 이는 이 연구에서 제안한 영상정합을 이용한 움직임 보정기법에 의해서 개선되었다. 답이 없는 문제, 문제 만들기, 일반화가 가능한 문제 등으로 보고, 수학적 창의성 중 특히 확산적 사고에 초점을 맞추어 개방형 문제가 확

  • PDF

Comparison of the Mid-term Changes at the Remnant Distal Aorta after Aortic Arch Replacement or Ascending Aortic Replacement for Treating Type A Aortic Dissection (A형 급성대동맥박리증에서 대동맥궁치환술과 상행대동맥치환술 후 잔존 원위부 대동맥의 변화에 대한 중기 관찰 비교)

  • Cho, Kwang-Jo;Woo, Jong-Su;Bang, Jung-Hee;Choi, Pill-Jo
    • Journal of Chest Surgery
    • /
    • v.40 no.6 s.275
    • /
    • pp.414-419
    • /
    • 2007
  • Background: Replacing the ascending aorta is a standard surgical option for treating acute type A aortic dissection. But replacing the aortic arch has recently been reported as an acceptable procedure for this disease. We compared the effects of aortic arch replacement for treating acute type A aortic dissection with the effects of ascending aortic replacement. Material and Method: From 2002 to 2006, 25 patients undewent surgical treatment for acute type A aortic dissection, 12 patients undewent ascending aortic replacement and 13 patients underwent aortic arch replacement. Among the aortic arch group, an additional distal stent-graft was inserted during the operation in 5 patients. 19 patients (11 arch replaced patients and 8 ascending aortic replaced patients) were followed up at the out patient clinic for an average of $756{\pm}373$ days. All the patients undewent CT scanning and we analyzed their distal aortic segments. Result: 4 patients who underwent ascending aortic replacement died, so the overall mortality rate was 16%. Among the 11 long term followed-up arch replacement patients, 2 patients (18.1 %) developed distal aortic dilatation and one of them underwent thoracoabdominal aortic replacement later on. However, among the 8 the ascending aortic replaced patients, 5 patients (62.5%) developed distal aortic dilatation. Conclusion: Aortic arch replacement is one of the safe options for treating acute type A aortic dissection. Aortic arch replacement for treating acute type A aortic dissection could contribute to a reduced distal aortic dilatation rate and fewer secondary aortic procedures.

Surgical Results for Treating Postpneumonectomy Empyema with BPF by Using an Omental Pedicled Flap and Thoracoplasty (전폐절제술 후 기관지 흉막루를 동반한 농흉에서 유경성 대망 이식편과 흉곽성형술을 이용한 수술적 치료에 대한 임상 고찰)

  • Jeong, Seong-Cheol;Kim, Mi-Jung;Song, Chang-Min;Kim, Woo-Shik;Shin, Yong-Chul;Kim, Byung-Yul
    • Journal of Chest Surgery
    • /
    • v.40 no.6 s.275
    • /
    • pp.420-427
    • /
    • 2007
  • Background: Postpneumonectomy empyema (PPE) due to bronchopleural fistula (BPF) can be a surgical challenge for surgeons. We analyzed the follow-up outcomes after performing omentopexy and thoracoplasty for the treatment of PPE with BPF after pneumonectomy. Material and Mehod: Between December 1991 and January 2006, 9 patients underwent BPF closure using an omental pedicled flap for the treatment of PPE with BPF after pneumonectomy. There were 7 males and 2 females (mean age: $45.9{\pm}9$ years). The patients were followed up for a mean of 58 months (median: 28 months, range: $6{\sim}169$). When we performed omentopexy, the surgical procedures for empyema were thoracoplasy for 8 patients and the Clagett procedure for 1 patient. Thoracoplasty was performed for the latter patient due to recurrence of empyema, Result: For the 8 patients who were treated by omentopexy and thoracoplasty, there was 1 operation-related death due to sepsis. During follow up, 1 patient, who was treated by omentopexy and a Clagett procedure, died of acute hepatitis 40 months postoperatively. The early mortality was 11.1% (8/9). Of the 8 patients, including the 1 late death patient, successful closure of the BPF were achieved in all patients (8/9) and the empyema was cured in 7 patients (7/8). Conclusion: The BPF closure using an omental pedicled flap was an effective method for treating PPE with BPF due to 75-destroyed lung, and thoracoplasty with simultaneous omentopexy was effective and safe for removing dead space if the patient was young and in a good general condition.