• Title/Summary/Keyword: interior ventilation

Search Result 144, Processing Time 0.021 seconds

A Study on The Architectural Plan Access Method for The Integrated Design of The Environmentally Friendly Architecture (친환경 건축의 통합설계를 위한 건축 계획적 접근방법에 관한 연구)

  • Cho, Sung-Hyun;Kim, Chul-Kyu
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.10 no.3
    • /
    • pp.79-86
    • /
    • 2010
  • From the research which sees the building which uses a natural control method with ecological architecture, continuity tried to divide the building which uses a physical control method with sustainable architecture. Ecological architecture analyzes the microclimate of the area and applies mining and natural ventilation leads and that the interior environment controls, the condition of the site actively and there is a possibility of seeing. Also sustainable architecture which is possible to lead and recycling and reuse of the resources and energy cyclic process of the construction resources to lead and the interior environment to control. Therefore the case where the facility system and structural system become integrated design organically in natural circulating method is many. Specially the sunshade system and double skin system are combined and structural system of the building and there is a possibility of having the envelope which form is feature. Today the buildings lead and the system integration process where the integral parts are systematic is demanded the interior environment which and an external form and that, they make they are there is a possibility of seeing. the environmental building which hits joins in with natural control method and the structure and facility system are integrated and has the tendency which is developed and there is a possibility of saying that a meaning with the alternative construction will be able to reduce the resources and an energy.

Analysis on TVOC Concentrations and Influence Factors of Newly-Built Apartments (신축 아파트의 총휘발성유기화합물 농도와 관련요인 분석)

  • Choi, Yoon-Jung;Kang, Mi-Ra;Lee, Hye-Min;An, Hye-Jung
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2006.05a
    • /
    • pp.268-271
    • /
    • 2006
  • The purpose of this study was to identify the influence of living factors on TVOC(Total Volatile Organic Compounds) concentrations for newly-built apartments. The field measurements of TVOC concentrations were made totally 30 times(5 times per one subject house) in six apartment units in which residents recently moved. Those apartments authorized its business approval before May 2004, the Act of Indoor Air auality Management for multi-use facilities. The findings were as follows: The TVOC concentrations of the measured subject apartments ranged from about 1/10 of the recommended standard for multi-use facilities($400{\mu}g/m^3$) to up to 90 times as high as the standard. Since then, the Recommended Standard of Indoor Air Quality Management for newly-built apartment house was announced in December 2005. In accordance with this standard($2390{\mu}g/m^3$) it ranged from about 1/100 to up to 15 times as high as the standard. The subject house whose TVOC concentrations reduced below the recommendation standard in the shortest period had the largest amount of ventilation (all the windows were open for ventilation in the past three months) among ail measured houses. The reason of another house whose TVOC concentrations were much higher than the rest was fronted with new furniture in the room. It's recommended that they should open all the windows for at least three months for ventilation in newly-built houses, and it would be better to avoid remodeling than needs be.

  • PDF

TVOC Concentrations and Residents' Responses on Sick House Syndrome of Newly-Built Apartments (신축 아파트의 TVOC 농도 및 거주자의 새집증후군 반응)

  • Choi Yoon-Jung;An Hye-Jung;Kang Mi-Ra;Lee Hye-Min
    • Korean Institute of Interior Design Journal
    • /
    • v.15 no.4 s.57
    • /
    • pp.129-137
    • /
    • 2006
  • The purpose of this study was to identify the influence of living factors on TVOC(Total Volatile Organic Compounds) concentrations and personal factors to reduce the Sick House Syndrome for newly-built apartments. The field measurements of TVOC concentrations were made totally 30 times(5 times per one subject house) in six apartment units in which residents recently moved. Those apartments authorized its business approval before May 2004, the Act of Indoor Air Quality Management for multi-use facilities. The Questionnaire surveys of residents' subjective responses on the Sick House Syndrome were carried out in 2nd measurement of each house. Respondents consisted of 20 residents living in the measured houses. The findings were as follows: The TVOC concentrations of the measured subject apartments ranged from about 1/10 of the recommended standard for multi-use facilities($400{\mu}g/m^3$) to up to 90 times as high as the standard. Since then, the Recommended Standard of Indoor Air Quality Management for newly-built apartment house was announced in December 2005. In accordance with this standard($2390{\mu}g/m^3$) it ranged from about 1/100 to up to 15 times as high as the standard. The subject house whose TVOC concentrations reduced below the recommendation standard in the shortest period had the largest amount of ventilation (all the windows were open for ventilation in the past three months) among all measured houses. The reason of another house whose TVOC concentrations were much higher than the rest was fronted with new furniture in the room. There turned out to be no apparent relations between the TVOC concentrations and the residents' individual responses of Sick House Syndrome. The responses were serious in those who stayed in their new houses for a long period or had disease like allergy. It's recommended that they should open all the windows for at least three months for ventilation in newly-built houses, and it would be better to avoid remodeling than needs be.

Analysis on Energy Demand Resulting From the Change in Window Area & Installation of Interior Exterior Blinds (건축물에너지효율등급 기밀시험이 등급에 미치는 영향분석)

  • Kim, Dae-Won;Chung, Kwang-Seop;Kim, Young-Il;Nam, Ariasae;Ju, Jung-Kyeong
    • Journal of Energy Engineering
    • /
    • v.23 no.1
    • /
    • pp.40-45
    • /
    • 2014
  • The ventilation frequency of 0.5 times in residential facilities is applied mandatorily to the housing facilities containing more than 100 house units to improve the indoor air quality and create comfortable interior conditions and pleasantness for residents. The Building Energy Efficiency Rating system requires the implementation of leakage test based on ventilation frequency with the test results being reflected in the efficiency ratings, thereby stimulating the precise construction of the fittings in the periphery of windows and savings of energy that can be lost due to the infiltration air. The inspection results of the Building Energy Efficiency Rating at the site showed that the ventilation frequency was in the range between 0.63 and 0.71 and that the difference was found to have a significant effect on the amount of energy reduction. It is urgent to conduct the study on highly leakage-proof buildings and construction methods, along with the expansion of mandatory leakage-proof diagnosis of non-residential buildings, considering the mandatory ventilation frequency below 0.6 for passive houses under the European standards and the target set by Korea to introduce the passive house, the rigorous standard for energy efficiency in buildings and mitigating their ecological footprint, by 2017 and achieve the zero house by 2025.

Comparative Analysis of Rural and Urban Residential Interior Elements Affecting Physically Disabled's Independence (재가지체장애인의 자립을 저해하는 농촌과 도시의 주거실내 환경요소에 대한 비교연구)

  • Park, Ji-Young;Jang, Mi-Seon;Lee, Yeun-Sook
    • Korean Institute of Interior Design Journal
    • /
    • v.25 no.1
    • /
    • pp.132-141
    • /
    • 2016
  • For those with disabilities, the residential area is the primary place to adapt the disabilities. Since the quality of the area gives a critical impact on their quality of life, it is essential to finding the measures to create the residential environment that supports their independence. In this regard, this study aimed to compare and analyze the interior elements of the houses that hinder the independence of the physically handicapped in the rural and urban areas, and conducted a survey on a total of 80 physically challenged in Seoul and Yeongwol (40 for each area). As a result, the respondents answered that the houses where they are currently living are hindering their independence regardless of area, and there were regional differences in the level of inconvenience with the size of living room, size of utility room, location of room, lighting and heating environment, ventilation system, deteriorated wallpapers and finishing materials, threshold and floor level difference and humidity control. This study has significance by providing the realistic measures to improve the housing environment of the physically challenged living in the rural and urban areas to be customized to them to increase their quality of life.

Hygrothermal Performance Improvement Plan of Standard Model for Rural Housing and Wooden Housing (농촌주택 및 목조주택 표준모델 구조체의 습·열 환경 성능 개선 방안)

  • Yoo, Dong-Wan;Lee, Tae-Goo
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.23 no.4
    • /
    • pp.63-71
    • /
    • 2021
  • The purpose of this study was to investigate whether the standard models for rural housing and wooden housing model have performance for hygrothermal and to propose a way of improvement relevant to hygrothermal performance for those models. All of the models to be analyzed were found to have some parts that were absent of stability in terms of performance for hygrothermal. In the process of analyzing the causes and proposing improvement measures, the following conclusions were derived. Fist, The exterior surface of the structure should be composed of a structure with good moisture permeability, and for the interior surface, a variable vapor retarder paper should be applied in consideration of the reverse condensation phenomenon in summer. Second, in terms of performance for hygrothermal, applications of external insulation plaster finish to the exterior wall or of ventilation method using a rafter vent on the roof should be avoided. Third, a rain screen method with a ventilation layer should be applied to the exterior wall, and a method of constructing ventilation layer separated from the insulation layer with a vapor retarder paper should be applied to the roof. Fourth, the application of insulation materials having capillary action, such as wood fiber insulation board or cellulose insulation board, contributes to more stable performance for hygrothermal.

Evaluation of a Fungal Spore Transportation in a Building under Uncertainty

  • Moon, Hyeun Jun
    • Architectural research
    • /
    • v.8 no.1
    • /
    • pp.37-45
    • /
    • 2006
  • A fungal spore transportation model that accounts for the concentration of airborne indoor spores and the amount of spores deposited on interior surfaces has been developed by extending the current aerosol model. This model is intended to be used for a building with a mechanical ventilation system, and considers HVAC filter efficiency and ventilation rate. The model also includes a surface-cleaning efficiency and frequency that removes a portion of spores deposited on surfaces. The developed model predicts indoor fungal spore concentration and provides an indoor/outdoor ratio that may increase or decrease mold growth risks in real, in-use building cases. To get a more useful outcome from the model simulation, an uncertainty analysis has been conducted in a real building case. By including uncertainties associated with the parameters in the spore transportation model, the simulation results provide probable ranges of indoor concentration and indoor/outdoor ratio. This paper describes the uncertainty quantification of each parameter that is specific to fungal spores, and uncertainty propagation using an appropriate statistical technique. The outcome of the uncertainty analysis showed an agreement with the results from the field measurement with air sampling in a real building.

Unsteady Analysis of Indoor Radon in Apartment Buildings Considering Finishing Materials and Ventilation (마감재 및 환기를 고려한 공동주택 실내 라돈 농도의 비정상 해석)

  • Cho, Hyun;Pang, Seung-Ki
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.15 no.4
    • /
    • pp.24-31
    • /
    • 2019
  • In this paper, we simulated a new apartment building by using radon emission test values from various building materials used as interior finishing materials. The simulations evaluated the radon concentration in the room according to the radon emissions and the ventilations for each type of finishing material (gypsum board, stone, tile and concrete). Overall concrete finish simulation case showed the highest concentration than the case using other materials due to the effect of wall area at the center of each room and the mean radon concentration at 1.5 m above the floor was slightly lower than the mean value at each center. In the case of the porch, pantry and bathroom, the radon concentration was high even when the same materials were used as in the other rooms.

A Study on the Planning Elements for Apartment Residents Living with Companion Animals (애완동물과의 공생을 고려한 공동주택 계획요소 연구)

  • Kim, Sun-A;Lee, Yeun-sok;Lee, Soo-jin
    • KIEAE Journal
    • /
    • v.5 no.2
    • /
    • pp.27-34
    • /
    • 2005
  • The purpose of this study were to examine actual conditions of apartment residents living with their companion animals and to identify their residential stress and needs of planning elements under those conditions. Questionnaire survey was adopted in this study, and 100 cases were used for data analysis. The subjects for this study were limited to the residents breeding pets in their apartments. The results of this study are as follows: Most of the residents share their living spaces with pets together like their family without spatial restrictions. They indicated problems related to breeding pets in their residence such as walking the dog, cleaning home, leaving pets alone, noise and unpleasant smell. However, they didn't seem to be stressed a lot for their living environments. In terms of residential planning elements, floor plans for effective natural ventilation, balcony with sufficient sunlight, sound proof system, easy-maintenance interior material, unlash area, rubbish bin, mechanical ventilation and central vacuum system and safe electric outlet were highly indicated.

A Study on Residents' Trade-Off Preference for Interior Environmental Attributes of Multi-Family Housing (집합주택의 실내환경속성에 대한 거주자 선호에 대한 연구 - 상대적 비교 접근법을 중심으로 -)

  • 이연숙
    • Journal of the Korean housing association
    • /
    • v.1 no.2
    • /
    • pp.49-66
    • /
    • 1990
  • This study is a case study to grasp residents` trade-off preference and opinions for selected interior environmental attributes of muilti-family housing. Interiew with structured questionnaire was carried out through pilot and main survey. On the basis of the result of pilot survey, interior environmental attributes for the main survey were selected. Selected attributes were the size of each residential room, the degree of openness between two rooms and interior facilities. Among them, trade-off approach was applied to the size of each residential room and interior facilities. For the main survey. 45 housewives living in 31 pyung apartment of a selected construction company to grasp the residents` trade-off preference and opinions on the selected attributes. In terms of the size of each room, subjects wanted the room to be lager, whereas master bedroom smaller, and family bathroom larger, wheareas toilet near master bedroom smaller. In terms of the degree of openness between two rooms, the present degree of openness between private and service area such as living room and balcony, and second bedroom and adjacent balcony need to be more open, whereas the present degree of openness between living room and dining room and between living room and kitchen need to be more closed. The comparative orders of important intems were the ventilation facility in the bathroom, drying poles for clothes in the balcony, interior landscape, and workable for hand washing clothes. In conclusion, measurement of preference using trade-off approach about selected interior environmental attributes in post-occupancy evaluation was regarded as a promising evaluation method to grasp the practical and comparative preference under constraints comparing to the typical existing methods.

  • PDF