• 제목/요약/키워드: interfacial bond

검색결과 188건 처리시간 0.026초

IV 천이금속 탄화물과 bcc Fe간 계면 에너지의 제일원리 연구 (An ab Initio Study of Interfacial Energies between Group IV Transition Metal Carbides and bcc Iron)

  • 정순효;정우상;변지영
    • 한국재료학회지
    • /
    • 제15권9호
    • /
    • pp.566-576
    • /
    • 2005
  • This paper describes an ab Initio study on interface energies, misfit strain energies, and electron structures at coherent interfaces Fe(bcc structure)/MCs(NaCl structure M=Ti, Zr, Hf). The interface energies at relaxed interfaces Fe/TiC, Fe/ZrC and Fe/HfC were 0.263, 0.153 and $0.271 J/m^2$, respectively. It was understood that the dependence of interface energy on the type of carbide was closely related to changes of the binding energies between Fe, M and C atoms before and after formation of the interfaces Fe/MCs with the help of the DLP/NNBB (Discrete Lattice Plane/ Nearest Neighbour Broken Bond) model and data of the electron structures. The misfit strain energies in Fe/TiC, Fe/ZrC and Fe/HfC systems were 0.390, 1.692 and 1.408 eV per 16 atoms(Fe: 8 atoms and MC; 8 atoms). More misfit energy was generated as difference of lattice parameters between the bulk Fe and the bulk MCs increased.

Epitaxial growth of yttrium-stabilized HfO$_2$ high-k gate dielectric thin films on Si

  • Dai, J.Y.;Lee, P.F.;Wong, K.H.;Chan, H.L.W.;Choy, C.L.
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제16권9호
    • /
    • pp.63.2-64
    • /
    • 2003
  • Epitaxial yttrium-stabilized HfO$_2$ thin films were deposited on p-type (100) Si substrates by pulsed laser deposition at a relatively lower substrate temperature of 550. Transmission electron microscopy observation revealed a fixed orientation relationship between the epitaxial film and Si; that is, (100)Si.(100)HfO$_2$ and [001]Si/[001]HfO$_2$. The film/Si interface is not atomically flat, suggesting possible interfacial reaction and diffusion, X-ray photoelectron spectrum analysis also revealed the interfacial reaction and diffusion evidenced by Hf silicate and Hf-Si bond formation at the interface. The epitaxial growth of the yttrium stabilized HfO$_2$ thin film on bare Si is via a direct growth mechanism without involoving the reaction between Hf atoms and SiO$_2$ layer. High-frequency capacitance-voltage measurement on an as-grown 40-A yttrium-stabilized HfO$_2$ epitaxial film yielded an dielectric constant of about 14 and equivalent oxide thickness to SiO$_2$ of 12 A. The leakage current density is 7.0${\times}$ 10e-2 A/$\textrm{cm}^2$ at 1V gate bias voltage.

  • PDF

Rehabilitation of RC structural elements: Application for continuous beams bonded by composite plate under a prestressing force

  • Abderezak, Rabahi;Rabia, Benferhat;Daouadji, Tahar Hassaine
    • Advances in materials Research
    • /
    • 제11권2호
    • /
    • pp.91-109
    • /
    • 2022
  • This paper presents a closed-form higher-order analysis of interfacial shear stresses in RC continuous beams strengthened with bonded prestressed laminates. For retrofitting reinforced concrete continuous beams is to bond fiber reinforced prestressed composite plates to their tensile faces. An important failure mode of such plated beams is the debonding of the composite plates from the concrete due to high level of stress concentration in the adhesive at the ends of the composite plate. The model is based on equilibrium and deformations compatibility requirements in and all parts of the strengthened beam, where both the shear and normal stresses are assumed to be invariant across the adhesive layer thickness. In the present theoretical analysis, the adherend shear deformations are taken into account by assuming a parabolic shear stress through the thickness of both the RC continuous beams strengthened with bonded prestressed laminates. The theoretical predictions are compared with other existing solutions. A parametric study has been conducted to investigate the sensitivity of interface behavior to parameters such as laminate stiffness and the thickness of the laminate where all were found to have a marked effect on the magnitude of maximum shear and normal stress in the composite member.

Effect of ages and season temperatures on bi-surface shear behavior of HESUHPC-NSC composite

  • Yang Zhang;Yanping Zhu;Pengfei Ma;Shuilong He;Xudong Shao
    • Advances in concrete construction
    • /
    • 제15권6호
    • /
    • pp.359-376
    • /
    • 2023
  • Ultra-high-performance concrete (UHPC) has become an attractive cast-in-place repairing material for existing engineering structures. The present study aims to investigate age-dependent high-early-strength UHPC (HESUHPC) material properties (i.e., compressive strength, elastic modulus, flexural strength, and tensile strength) as well as interfacial shear properties of HESUHPC-normal strength concrete (NSC) composites cured at different season temperatures (i.e., summer, autumn, and winter). The typical temperatures were kept for at least seven days in different seasons from weather forecasting to guarantee an approximately consistent curing and testing condition (i.e., temperature and relative humidity) for specimens at different ages. The HESUHPC material properties are tested through standardized testing methods, and the interfacial bond performance is tested through a bi-surface shear testing method. The test results quantify the positive development of HESUHPC material properties at the early age, and the increasing amplitude decreases from summer to winter. Three-day mechanical properties in winter (with the lowest curing temperature) still gain more than 60% of the 28-day mechanical properties, and the impact of season temperatures becomes small at the later age. The HESUHPC shrinkage mainly occurs at the early age, and the final shrinkage value is not significant. The HESUHPC-NSC interface exhibits sound shear performance, the interface in most specimens does not fail, and most interfacial shear strengths are higher than the NSC-NSC composite. The HESUHPC-NSC composites at the shear failure do not exhibit a large relative slip and present a significant brittleness at the failure. The typical failures are characterized by thin-layer NSC debonding near the interface, and NSC pure shear failure. Two load-slip development patterns, and two types of main crack location are identified for the HESUHPC-NSC composites tested in different ages and seasons. In addition, shear capacity of the HESUHPC-NSC composite develops rapidly at the early age, and the increasing amplitude decreases as the season temperature decreases. This study will promote the HESUHPC application in practical engineering as a cast-in-place repairing material subjected to different natural environments.

Analysis of composite frame structures with mixed elements - state of the art

  • Ayoub, Ashraf
    • Structural Engineering and Mechanics
    • /
    • 제41권2호
    • /
    • pp.157-181
    • /
    • 2012
  • The paper presents a review of the application of the newly proposed mixed finite element model for seismic simulation of different types of composite frame structures. To evaluate the performance of the element, a comparison with displacement-based and force-based models is conducted. The study revealed that the mixed model is superior to the others in terms of both speed of convergence and numerical stability, and is therefore considered the most practical approach for modeling of composite structures. In this model, the element is derived using independent force and displacement shape functions. The nonlinear response of the frame element is based on the section discretization into fibers with uniaxial material models. The interfacial behavior is modeled using an inelastic interface element. Numerical examples to clarify the advantages of the model are presented for the following structural applications: anchored reinforcing bar problems, composite steel-concrete girders with deformable shear connectors, beam on elastic foundation elements, R/C girders strengthened with FRP sheets, R/C beam-columns with bond-slip, and prestressed concrete girders. These studies confirmed that the model represents a major advancement over existing elements in simulating the inelastic behavior of composite structures.

Modeling of the ITZ zone in concrete: Experiment and numerical simulation

  • Setiawan, Yanuar;Gan, Buntara S.;Han, Ay Lie
    • Computers and Concrete
    • /
    • 제19권6호
    • /
    • pp.641-649
    • /
    • 2017
  • The discovery of the Interfacial Transition Zone (ITZ) by Farran in 1956 initiated a new era in the study of the behaviour of concrete. Acknowledged as the weak link, this ITZ was studied extensively, numerically as well as experimentally. While the complementary experimental tests illustrated the visual behaviour of this specimen under increasing monotonic compression loading, a perfect bond within the ITZ has also been studied by using finite element analysis for comparison purposes. Finite element analysis was used to evaluate the degree of correctness and precision of the proposed ITZ model. This paper discusses the use of the cutoff bar in finite element modeling, representing the ITZ of a single aggregate (inclusion) in a mortar matrix. Experiments were conducted to investigate the influence of the ITZ model on the single inclusion specimen's strength. The model was tested for some inclusions that varied in dimension and shape. The effect of inclusion shape on the stress concentrations of the specimens was examined. The aim of this research work is to propose a simple yet accurate ITZ model to be used in the commercially available finite element software packages.

비정질 PEEK 필름의 Self-Bonding강도에 미치는 제조공정변수의 영향 (The Effect of Processing Variables on Self-Bonding Strength in Amorphous PEEK Films)

  • 조범래
    • 한국재료학회지
    • /
    • 제5권2호
    • /
    • pp.191-196
    • /
    • 1995
  • 비정질 PEEK 필름의 self-bonding강도는 접합시의 공정변수(시간, 온도, 그리고 압력)와 밀접한 관계가 있다. 본 연구에서는 이러한 공정변수의 효과를 규명하기 위하여 각기 다른 접합조건하에서 개발된 시편들의 self-bonding강도를 single lap-shear test를 통하여 측정된 각각의 전단 응력(shear strength)으로 나타내었다. 개발된 self-bonding강도는 접합온도가 증가함에 따라 증가하였으며, 접합시간의 1/4승에 일차함수적으로 비례증가하였다. 접합공정 중의 압력의 효과는 단지 초기 접합단계인 wetting에 기여하였을 뿐 self-bonding강도 자체에는 거의 영향을 미치지 않는 것으로 사려되었다. 결론적으로 비정질 PEEK 필름의 self-bonding현상은 현장에서의 실제 접합공정에서 어떠한 접착재료의 사용없이도 모재와 같은 강도를 개발하는데 무한한 가능성이 있는 것으로 판단되었다.

  • PDF

Intermediate crack-induced debonding analysis for RC beams strengthened with FRP plates

  • Wantanasiri, Peelak;Lenwari, Akhrawat
    • Structural Engineering and Mechanics
    • /
    • 제56권3호
    • /
    • pp.473-490
    • /
    • 2015
  • This paper presents the analysis of intermediate crack-induced (IC) debonding failure loads for reinforced concrete (RC) beams strengthened with adhesively-bonded fiber-reinforced polymer (FRP) plates or sheets. The analysis consists of the energy release and simple ACI methods. In the energy release method, a fracture criterion is employed to predict the debonding loads. The interfacial fracture energy that indicates the resistance to debonding is related to the bond-slip relationships obtained from the shear test of FRP-to-concrete bonded joints. The section analysis that considers the effect of concrete's tension stiffening is employed to develop the moment-curvature relationships of the FRP-strengthened sections. In the ACI method, the onset of debonding is assumed when the FRP strain reaches the debonding strain limit. The tension stiffening effect is neglected in developing a moment-curvature relationship. For a comparison purpose, both methods are used to numerically investigate the effects of relevant parameters on the IC debonding failure loads. The results show that the debonding failure load generally increases as the concrete compressive strength, FRP reinforcement ratio, FRP elastic modulus and steel reinforcement ratio increase.

Optimal pressure and temperature for Cu-Cu direct bonding in three-dimensional packaging of stacked integrated circuits

  • Seunghyun Yum;June Won Hyun
    • 한국표면공학회지
    • /
    • 제56권3호
    • /
    • pp.180-184
    • /
    • 2023
  • Scholars have proposed wafer-level bonding and three-dimensional (3D) stacked integrated circuit (IC) and have investigated Cu-Cu bonding to overcome the limitation of Moore's law. However, information about quantitative Cu-Cu direct-bonding conditions, such as temperature, pressure, and interfacial adhesion energy, is scant. This study determines the optimal temperature and pressure for Cu-Cu bonding by varying the bonding temperature to 100, 150, 200, 250, and 350 ℃ and pressure to 2,303 and 3,087 N/cm2. Various conditions and methods for surface treatment were performed to prevent oxidation of the surface of the sample and remove organic compounds in Cu direct bonding as variables of temperature and pressure. EDX experiments were conducted to confirm chemical information on the bonding characteristics between the substrate and Cu to confirm the bonding mechanism between the substrate and Cu. In addition, after the combination with the change of temperature and pressure variables, UTM measurement was performed to investigate the bond force between the substrate and Cu, and it was confirmed that the bond force increased proportionally as the temperature and pressure increased.

도재 수복물 합착시 상아질 접착 술식이 레진 시멘트의 전단결합강도에 미치는 영향 (An effect of Dentin Bonding Procedure on the Shear Bond Strength of Resin Cement to Porcelain Restoration)

  • 강혜진;신수연
    • 구강회복응용과학지
    • /
    • 제28권1호
    • /
    • pp.67-78
    • /
    • 2012
  • 본 연구에서는 Clearfil$^{TM}$ SEBond와 Adapter$^{TM}$ SingleBond2를 사용하여 즉시 상아질 접착을 하였을 때 지연 상아질 접착을 하였을 때와 비교해 전단결합강도 및 파절 양상을 관찰하였다. 발치된 구치를 네 군으로 나누어 1군은 대조군으로 치아 삭제 직후 시편을 상아질 접착제를 광중합 후 합착하였고 2군과 3군은 치아 삭제 직후 각각 Clearfil$^{TM}$ SEBond와 Adapter$^{TM}$ SingleBond2로 즉시 상아질 접착을 한 후 열 순환기에 교대침수 시키고 상아질 접착제를 광중합하지 않고 합착하였다. 4군은 삭제 후 아무 처리를 하지 않고 열 순환 후 상아질 접착제를 광중합하지 않고 합착하였다. 이후 만능 시험기로 모든 시편의 전단결합강도를 측정하였으며, 광학현미경으로 파절 양상을 관찰하였다. 측정 결과 대조군이 가장 높은 결합력을 보였고 지연 상아질 접착을 시행한 군에서 가장 낮은 결합력을 보였다. Clearfil$^{TM}$ SEBond로 즉시 상아질 접착을 한 군은 대조군과 유의한 차이를 보이지 않았고, 4군보다 유의하게 높은 결합력을 보였다. Adapter$^{TM}$ SingleBond2를 이용하여 즉시 상아질 접착을 한 군은 4군보다 높은 결합력을 보였으나 유의한 차이를 보이지 않았다. 파절 양상에서는 대조군과 2군이 4군에 비해 유의하게 혼합형 파절이 많이 나타났다(p<0.05). 이상의 결과로 보아, 도재 수복물의 합착에 있어서 치아 삭제 후 즉시 상아질 접착제를 적용하는 것이 바람직하다고 사료된다. 하지만 이때 사용되는 상아질 접착제의 선택에 있어서는 실제 임상 조건에서의 더 많은 연구가 필요하리라 사료된다.