• Title/Summary/Keyword: intensity of light

Search Result 2,538, Processing Time 0.027 seconds

Effects of light intensity on growth performance, blood components, carcass characteristics, and welfare of broilers

  • Hee-Jin, Kim;Jiseon, Son;Hyun-Soo, Kim;Eui-Chul, Hong;Ji-Hyuk, Kim
    • Journal of Animal Science and Technology
    • /
    • v.64 no.5
    • /
    • pp.985-996
    • /
    • 2022
  • This study investigated the effects of light intensity on growth performance, blood components, eye condition, and carcass characteristics of broiler chickens. Three hundred and fifty-two 1-day-old male chicks were assigned to one of four treatments (four repetitions per treatment, 22 birds per repetition) and reared in a floor pen for 5 weeks. From the second week, chicks were reared under four different levels of light intensity (5, 20, 35, and 50 lx) and the lighting duration was maintained at 18-hours light : 6-hours dark (18L : 6D). The feed intake and body weight were measured weekly. At 35 days of age, 12 birds per treatment were randomly selected for blood sampling, eye measurement, and carcass analysis. There were no significant differences in body weight gain, feed intake, and feed conversion ratio among treatments. Triglyceride levels in the serum were significantly higher in the 5 lx treatment, and creatinine was significantly lower in the 5 lx treatment (p < 0.05). The heterophil : lymphocyte ratios decreased significantly as light intensity increased (p < 0.05); however, other blood cell compositions were not affected by light intensity. Interleukin-6 content was significantly higher in the 5 lx treatment than in other treatments (p < 0.05), but the content of tumor necrosis factor-α was not significantly different among treatments. Serum corticosterone concentration was significantly higher at 5 lx than at 20, 35, and 50 lx (p < 0.05). The corneal diameter was the highest in 5 lx treatment (p < 0.05), and tended to increase as the light intensity decreased. Other eye parameters were not significantly different among treatments, but displayed a tendency to increase as the light intensity decreased. Carcass yield and part yields were not affected by light intensity. Meat quality parameters (pH, color, cooking loss, and water-holding capacity) did not show significant difference among the treatments. The results indicate that a light intensity of 5 lx may increase physiological stress or have a negative effect on broiler welfare, even if the performance and carcass characteristics are not affected. Therefore, a light intensity of 20 lx or above is recommended considering both the growth performance and welfare of broilers.

Studies on Growth and Biomass Production of Abies koreana Seedlings under Different Relative Light Intensity (상대광도 차이에 따른 구상나무 유묘의 생장과 물질생산에 관한 연구)

  • 조혜경;홍성각;김종진
    • Journal of Korea Foresty Energy
    • /
    • v.20 no.2
    • /
    • pp.58-68
    • /
    • 2001
  • This study was carried out to investigate the growth and biomass production of Abies koreana seedlings under different relative light intensity. The 5-year-old potted seedlings were grown for 24 months under different light intensity of 100%, 50%, 30%, 10% and 2% of the natural full light intensity. The results were as follows: 1. Height growth was similar in the seedlings under different light intensities except in 2% of the full sun light intensity, having shown the lowest height growth. 2. Root collar diameter growth was reduced gradually by decreasing of the relative light intensity. 3. The seedlings which were grown under relatively low light intensity showed the later starting date of the stem growth in the next spring and showed the smaller number of new needles, and the smarter number and the shorter length of new shoot of the seedlings. 4. Total dry mass including the dry mass of leaves, shoot and root was reduced by decreasing of the relative light intensity. 5. In case of the seedling grown in one year shading condition, the ratio of the dry mass of current-year needles and stem to that of the above one-year-old needles and stem was ranged from 0.99$\pm$0.25 to 1.06$\pm$0.06 and was not significally different among the seedlings grown under 100%, 50% and 30% of the relative light intensity. And the radio was ranged from 0.60$\pm$0.04 to 0.52$\pm$0.03 in the seedlings grown under 10% and 2% of the relative light intensity, respectively. In case of the seedling grown in two years shading, the ratio of the dry mass of current-year needles and stem to that of the above one-year-old needles and stem was ranged from 0.79$\pm$0.04 to 1.00$\pm$0.03 and was not significally different among the seedlings grown under 100, 50, 30% and 10% of the relative light intensity. And the ratio was 0.29$\pm$0.03 in the seedlings grown under 2% of the relative light intensity, respectively. 6. T/R ratio of the seedlings grown in one year shading condition was ranged from 3.35$\pm$0.33 to 4.61$\pm$0.25 and was not significantly different among the relative light intensities of 100%, 50%, 30% and 10%. The seedlings grown under 2% of relative light intensity showed the highest T/R ratio of 7.36$\pm$0.15. In case of the two years shadings the T/R ratio was ranged from 1.76$\pm$0.11 to 3.12$\pm$0.19 and increased as relative light intensity decreased except 2.01$\pm$0.14 in 2% of relative light intensity.

  • PDF

Detection of a Light Region Based on Intensity and Saturation and Traffic Light Discrimination by Model Verification (명도와 채도 기반의 점등영역 검출 및 모델 검증에 의한 교통신호등 판별)

  • Kim, Min-Ki
    • Journal of Korea Multimedia Society
    • /
    • v.20 no.11
    • /
    • pp.1729-1740
    • /
    • 2017
  • This paper describes a vision-based method that effectively recognize a traffic light. The method consists of two steps of traffic light detection and discrimination. Many related studies have used color information to detect traffic light, but color information is not robust to the varying illumination environment. This paper proposes a new method of traffic light detection based on intensity and saturation. When a traffic light is turned on, the light region usually shows values with high saturation and high intensity. However, when the light region is oversaturated, the region shows values of low saturation and high intensity. So this study proposes a method to be able to detect a traffic light under these conditions. After detecting a traffic light, it estimates the size of the body region including the traffic light and extracts the body region. The body region is compared with five models which represent specific traffic signals, then the region is discriminated as one of the five models or rejected as none of them. Experimental results show the performance of traffic light detection reporting the precision of 97.2%, the recall of 95.8%, and correct recognition rate of 94.3%. These results shows that the proposed method is effective.

Analysis of Spectral Light Intensity of High Pressure Sodium and Metal Halide Lamps for Plant Growth (식물생장용 고압나트륨램프와 메탈할라이드램프의 분광 광강도 분석)

  • Lee, Hye-In;Kim, Yong-Hyeon;Kim, Dong-Eok
    • Journal of Biosystems Engineering
    • /
    • v.35 no.6
    • /
    • pp.413-419
    • /
    • 2010
  • Plant growth was greatly affected by the spectral distribution and light intensity of artificial lighting sources. In this study, the spectral characteristics of high power sodium (HPS) lamps and metal halide (MH) lamps produced by three different manufacturers were measured. Even though the spectral distribution of HPS lamps with lamp wattage of 250 W and 400 W was very similar, but the spectral light intensity by the manufacturers was different. Difference in the spectral light intensity of MH lamps by the manufacturers was increased with the increasing lamps wattage. Light intensity at the region of blue (B), green (G), red (R) and far-red (FR) light of HPS and MH lamps was also analyzed. HPS lamps showed the light intensity in order of R, FR, B and G light. The ratio of G, B, R and FR to photosynthetic photon flux (PPF) of HPS lamps with the lamp wattage of 250 W was 3.0-3.2%, 5.5-5.9%, 17.3-19.2% and 6.5-7.8%, respectively. For MH lamps, it showed the light intensity in order of R, FR, B, and G. The ratio of B, G, R, and FR to PPF of MH lamps with 250 W was 14.0-15.5%, 22.6-27.5%, 7.5-9.5% and 2.7-4.2%, respectively. HPS and MH lamps with 400 W had a relatively smaller ratio of R and FR to PPF than those with 250 W. HPS lamps showed that the ratio of light intensity of B and FR to R was 0.15-0.28 and 0.36-0.4, respectively. For MH lamps, the ratio of light intensity of B and FR to R was 1.26-2.72 and 0.27-0.56, respectively. From these results, it was concluded that the portion of blue light of MH lamps was higher than those of HPS lamps.

The scanned point-detecting system for three-dimensional measurement of light emitted from plasplay panel (플라즈마 디스플레이 패널에서 방출되는 광의 3차원 측정을 위한 Scanned Point-Detecting System)

  • 최훈영;이석현;이승걸
    • Korean Journal of Optics and Photonics
    • /
    • v.12 no.2
    • /
    • pp.103-108
    • /
    • 2001
  • In this paper, we designed and made the scanned point detecting system for 3-dimensional measurement of the light emitted from plasma display panel (PDP) , and we measured and analyzed 3-dimensional light emitted from a real PDP by using this scanned point detecting system. The scanned point detecting system has a point detector with a pinhole. The light emitted from the source at the in-focus position can pass through the pinhole and be collected by detector. The light from other sources at outof-focus positions is focused at points in front of or behind the pinhole, and thus it is intercepted by the pinhole. Therefore, we can detect light information from a particular point of a PDP cell of 3-dimensional structure. We know the electric field distribution inside the PDP cell from the 3-dimensionallight intensity distribution measured by using the scanned point detecting system. As the Z axial measurement increases, the intensity of light detected increases and intensity of light detected on the inside edge of the ITa electrode is larger than outside edge of the ITa eletrode and gap of the ITa electrodes. Also, as the measurement point moves from one barrier rib to another, the detected light is weaker near to the barrier ribs than at the center between the barrier ribs. The emitted light is concentrated at the center between barrier ribs. ribs.

  • PDF

The Variation of Sapphire Substrate Shape of Micro LED Array to Increasing of Light Intensity and Contrast Ratio (Light Intensity 및 명암비 향상을 위한 마이크로 LED의 사파이어 기판 형상 변화 연구)

  • Cha, Yu-Jung;Kwak, Joon Seop
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.34 no.1
    • /
    • pp.8-15
    • /
    • 2021
  • Micro-LEDs can be applied to various parts of a product. However, it has disadvantages compared to general LEDs in large displays such as low efficiency, intensity, and contrast ratio, among others, owing to their short history of study. The simulations were carried out using ray-tracing software to investigate the change in light intensity and light distribution according to pattern shapes on the sapphire substrate of the flip-chip micro-LED (FC μ-LED) array. Three patterns-concave square patterns, convex square patterns, and Ag coated convex patterns-which existed on the opposite side of FC μ-LEDs (115 ㎛ × 115 ㎛) array, were applied. The intensity of FC μ-LEDs on the center of the receivers depends on the pattern depth with shape. The concave square patterns having FC μ-LEDs arrays show that decreasing intensity as the patterns depth. On the contrary, the convex square patterns having FC μ-LEDs arrays shows that increasing intensity as the patterns depth. In addition, the highest intensity shows that FC μ-LEDs having Ag-coated convex patterns on the opposite side of sapphire lead to a reduction in light crosstalk owing to the Ag film.

Effect of LED Light Quality and Intensity on Growth Characteristics of Ginseng Cultivated in Plastic House

  • Sang Young Seo;Jong hyeon Cho;Chang Su Kim;Hyo Jin Kim;Min Sil An;Du Hyeon Yoon
    • Proceedings of the Plant Resources Society of Korea Conference
    • /
    • 2020.12a
    • /
    • pp.61-61
    • /
    • 2020
  • This experiment was carried out using artificial bed soil and LED in the plastic film house(irradiation time: 07:00-17:00/day). Seedlings(n=63 per 3.3 m2) of ginseng was planted on May 17, 2018. LED was combined with red and blue light in a 3:1 ratio and irradiated with different light intensity(40-160 µmol/m2/s). Average air temperature from April to September according to the light intensity test was 20.4℃-20.9℃. Average artificial bed soil temperature was 20.1℃-21.7℃. The test area where fluorescent lamp was irradiated tended to be somewhat lower than the LED irradiation area. The chemical properties of the test soil was as follows. pH levels was 6.6-6.7, EC levels 0.9-1.3 dS/m and OM levels 30.6-32.0%. The available P2O5 contents was 73.3-302.3 mg/kg. Exchangeable cations K and Ca contents were higher than the allowable ranges and mg content was high in the fluorescent lamp treatment. The photometric characteristics of LED light intensity are as follows. The greater the light intensity, the higher the PPFD(Photosynthetic Photon Flux Density) value, illuminance and solar irradiation. Fluorescent lamp treatment had high illuminance value, but PPFD and solar irradiation were lower than LED intensity 40 µmol/m2/s treatment. The photosynthetic rate increased(2.0-3.8 µmolCO2/m2/s) as the amount of light intensity increased, peaking at 120 µmol/m2/s, and then decreasing. The SPAD (chlorophyll content) value decreased as the amount of light intensity increased, and was the highest at 36.1 in fluorescent lamp treatment. Ginseng germination started on April 5 and took 14-17 days to germinate. The overall germination rate was 68.8-73.6%. The growth of aerial parts(plant height etc.) were generally excellent in the treatment of light intensity of 120-160 µmol/m2/s. The plant height was 41.9 cm, stem length was 24.1 cm, leaf length was 9.8 cm and stem diameter was 5.6 mm. The growth of underground part (root length etc.) was the best in the treatment with 120 µmol/m2/s of light intensity. Due to the root length was long(24.8 cm) and diameter of taproot was thick(18.7 mm), the fresh root weight was the heaviest at 24.8 g. There were no disease incidence such as Alternaria blight, Gray mold and Anthracnose. Disease of Damping-off caused by Rhizoctonia solani occurred 0.6-1.5% and incidence ratio of rusty root ginseng was 30.8-62.3%. It is believed that the reason for the high incidence of rusty root ginseng is that the amount of field moisture capacity of artificial bed soil is larger than the soil. Leaf discoloration rate was 13.7-32.3%.

  • PDF

Effect of light intensity on the ozone formation and the aerosol number concentration of ambient air in Seoul (광도가 서울 대기의 오존 생성 및 에어로졸 수 농도에 미치는 영향)

  • Bae, Gwi-Nam;Park, Ju-Yeon;Kim, Min Cheol;Lee, Seung-Bok;Moon, Kil-Choo;Kim, Yong Pyo
    • Particle and aerosol research
    • /
    • v.4 no.1
    • /
    • pp.9-20
    • /
    • 2008
  • The effect of light intensity on the ozone formation and the aerosol number concentration during the photochemical reactions of ambient air was investigated in an indoor smog chamber. The smog chamber consists of a housing, 64 blacklights, and a $2.5-m^3$ reaction bag made of Teflon film. The bag was filled with the unfiltered ambient air in Seoul from January 10 to March 18, 2002. In this work, the photolysis rate of $NO_2$, $k_1$ was used as an index of light intensity. Three levels of light intensity were controlled by changing the number of blacklights turned on among 64 blacklights: $0.29min^{-1}$ (50%), $0.44min^{-1}$ (75%), $0.57min^{-1}$ (100%). The ozone concentration increased rapidly within 10 minutes after irradiation irrespective of light intensity, thereafter it increased linearly during the irradiation. The ozone production rate seems to be dependent on both the light intensity and the quality of ambient air introduced into the reaction bag. The change in aerosol number concentration also depended on both the light intensity and the ambient air quality, especially aerosol size distribution. Based on the initial ambient aerosol size distributions, the photochemical potential for aerosol formation and growth is classified into two cases. One is the case showing aerosol formation and growth processes, and the other is the case showing no apparent change in particle size distribution.

  • PDF

MICROLEAKAGE OF CL V COMPOSITE RESTORATIONS USING VARIOUS LIGHT CURING METHODS (광중합 복합레진 수복시 여러 광조사 방법에 따른 미세변연누출에 관한 연구)

  • Yang, Chol-Young;Yoo, Hyeon-Mee;Kwon, Hyuk-Choon
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.2
    • /
    • pp.299-308
    • /
    • 2000
  • The purpose of this in vitro study was to evaluate the microleakage of 5 curing methods in class V composite restorations which are composed of two-step light curing, pulse-delay cure, low curing-light intensity, moderate curing-light intensity and high curing-light intensity. In this study, class V cavities were prepared on buccal and lingual surfaces of 50 extracted human upper or lower molars on cementum margin. Single Bond adhesive and Z-100 shade A2 were applied for each group following the manufacture's instruction. The experimental teeth were randomly divided into 5 groups of 10 samples (20 surfaces) each. Group 1: two-step light curing; Group 2: pulse-delay cure; Group 3: low curing-light intensity; Group 4: moderate curing-light intensity; Group 5: high curing-light intensity. After 500 thermocycling between $5^{\circ}C$ and $55^{\circ}C$, the 60 teeth were placed in 2% methylene blue dye for 24 hours, then rinsed with tab water. The specimens were embedded in clear resin, then sectioned buccolingually through the center of restoration with a low speed diamond saw. The dye penetration on each of the specimen was then observed with a stereomicroscope at ${\times}20$. The composite resin/tooth interfaces were examined under Scanning Electron Microscopy. The results were statistically analyzed using the Kruskal-Wallis One Way ANOVA and Dunn's Method. The results of this study were as follows. 1. In all groups, the leakage values seen at the enamel margin were significantly lower than those seen at the dentin margin(P<0.05). 2. No group in this study showed significant differences in leakage values at both the enamel and the dentin margins(P<0.05). 3. In all groups, the gaps seen at the enamel margin were significantly lower than those seen at the dentin margin(P<0.05). 4. The gaps in this study showed significant differences and two-step light-curing and low curing-light intensity produced significant less gap than high curing-light intensity(P<0.05).

  • PDF

Development of the Fluorescence Endoscope System with Dual Light Source Apparatus (복합 광원을 갖는 형광 내시경 개발)

  • Bae, Soo-Jin;Kang, Uk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.1
    • /
    • pp.222-226
    • /
    • 2007
  • We suggest the fluorescence endoscope system that has light source apparatus providing selectable white or excitation light. White light source generates normal color images and is easily switched over to excitation light with the wide spectrum range from 380 nm to 580 nm. 5-ALA is deposited selectively in the abnormal tissue like cancer and causes fluorescence in the red spectrum range when excited by blue spectrum range. In addition, the others of excitation light make the color background image by reflected light to allow accurate orientation and visualization of the abnormal tissue and around. According to clinical studies, the fluorescence intensity contrast that defines the fluorescence intensity of lesion over the fluorescence intensity of around has more than 2 in tumour. Proposed system is useful and objective way in early diagnosis. Furthermore, it can be used in the biopsy for tumour classification at the highest fluorescence intensity point.