22.9[kV] 배전선로 주변의 전장과 자장의 분포 (Profiles of electric and magnetic fields in the vicinity of 22.9[kV] Distribution Line)

  • 이복희;길형준;안창환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1653-1655
    • /
    • 1998
  • In this paper, measurement and analysis of ELF electric and magnetic fields in the vicinity of 22.9[kV] distribution line have been performed. The height of measuring point from the earth's surface was 1[m], and the distance between the device and the operator was more than 3[m]. The experiments have been carried out by lateral profile, and we have made use of FIELDS program for the sake of comparision the experimental data with the theoretical value. Electric and magnetic fields intensity were strong under a distribution line, and were inversely proportional to lateral distance. The profiles of electric field were M shape and those of magnetic field were $\cap$ shape. Electric and magnetic fields intensity were increased with increasing the measurement height.

  • PDF

22.9[kV] 배전선로 주변의 전장과 자장의 분포 (Profiles of Electric and Magnetic Fields around 22.9[kV] Distribution Lines)

  • 이복희;;박종순;길형준
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제13권2호
    • /
    • pp.178-178
    • /
    • 1999
  • In recent years, the electromagnetic environments are varied with the increase of power consumption and the spread of household electric appliances. Most of the interests to date have concentrated in the area of human health effects associated with exposure to power frequency electric and magnetic fields, and thus the precise measurement and analysis are required. In this paper, the measurements and analysis of the extremely low frequency(ELF) electric and magnetic fields produced by actual 22.9[kV] distribution lines were performed. The experiments have been carried out by lateral profile, and the theoretical analyses were made by use of FIELDS program for the sate of comparison with the experimental data. Electric and magnetic field intensity were strong under power distribution lines, and were inversely proportional to lateral distance. The profiles of electric and magnetic fields were M and ∩ shapes, respectively, and the measured data were good in agreement with the theoretical results. Both the electric and magnetic field intensity were increased with increasing the measurement height.

Effect of change intensity fields of magnetized water on fresh and hardened characteristics of concrete

  • Ali S. Ahmed;Mohamed M.Y. Elshikh;Mosbeh R. Kaloop;Jong Wan Hu;Walid E. Elemam
    • Computers and Concrete
    • /
    • 제31권2호
    • /
    • pp.97-110
    • /
    • 2023
  • This study investigates experimentally the impact of magnetized water (MW) on the fresh and hardened characteristics of concrete. Five types of MW are produced using magnetic fields of 1.4 and 1.6 Tesla for treating water with 100, 150, and 250 cycles. The concrete properties are assessed using the slump test, compressive strength test, scanning electron microscopy (SEM) analysis, energy dispersive X-ray analysis (EDX), and Fourier transform infrared spectrophotometry (FTIR). Furthermore, the chemical-physical characteristics of tap water (TW) and MW are evaluated. The results showed the magnetic field intensity has a significant impact on the magnetization effect; the best magnetizing conditions were found when TW was exposed successively to magnetic fields of 1.6 T and 1.4 T for 150 cycles. In addition, 150 MW cycles can be used to improve the compressive strength and workability of concrete by 40% and 17%, respectively. pH, total dissolved solids, and electrical conductivity improved by 15%, 17%, and 7%, respectively, when using MW. Additionally, MW can be used to enhance cement hydration chemical processes and made concrete's structure denser.

KI Criteria of Surface Check under Stepwise Loadings of Drying Stresses

  • Park, Jung-Hwan
    • Journal of the Korean Wood Science and Technology
    • /
    • 제27권4호
    • /
    • pp.51-56
    • /
    • 1999
  • Finite element method was utilized to analyze crack tip stress and displacement field under drying stress case as stepwise loading. Opening mode of single-edge-notched model was employed and analyzed by linear elastic fracture mechanics of plane stress case. The drying stresses were applied as stepwise loads at the boundary elements of the model with 10 steps of time serial. The stress intensity factor($K_I$) for opening mode reached to its maximum just prior to the stress reversal. The $K_I$ from the displacement fields revealed 1.7 times higher than those from stress fields. By comparing the two sets of $K_I$ from displacement and stress fields, single parameter $K_I$ showed its validity to characterize displacement fields around the crack tip front while stress field could not be characterized due to large variations between two sets of data.

  • PDF

Investigation of the effects of free-stream turbulence on wind-induced responses of tall building by Large Eddy Simulation

  • Li, Q.S.;Hu, G.;Yan, Bo-Wen
    • Wind and Structures
    • /
    • 제18권6호
    • /
    • pp.599-618
    • /
    • 2014
  • In this study, a square rectangular tall building is considered to investigate the effects of turbulence integral length scale and turbulence intensity on the along-wind responses, across-wind responses and torsional responses of the tall building by Large Eddy Simulation (LES). A recently proposed inflow turbulence generator called the discretizing and synthesizing random flow generation (DSRFG) approach is applied to simulate turbulent flow fields. It has been proved that the approach is able to generate a fluctuating turbulent flow field satisfying any given spectrum, desired turbulence intensity and wind speed profiles. Five profiles of turbulence integral length scale and turbulence intensity are respectively generated for the inflow fields by the DSRFG approach for investigating the effects of turbulence integral length scale and turbulence intensity on the wind-induced responses of the tall building. The computational results indicate that turbulence integral length scale does not have significant effect on the along-wind (displacement, velocity and acceleration) responses, across-wind displacement and velocity responses, while the across-wind acceleration and torsional responses vary without a clear rule with the parameter. On the other hand, the along-wind, across-wind and torsional responses increase with the growth of turbulence intensity.

이종재료간 V-노치균열의 응력특이성과 응력강도계수의 특성 및 결정에 관한 연구 (A Study on the Determination and Characteristics of Stress Intensity Factors and Stress Singularities for V-notched Cracks in Dissimilar Materials)

  • 조상봉;윤성관
    • 대한기계학회논문집
    • /
    • 제16권10호
    • /
    • pp.1890-1899
    • /
    • 1992
  • 본 연구에서는 이종재료간의 Ⅴ-노치균열의 노치각도 및 재료의 종류에 따른 응력특이성지수와 응력강도 계수 해석에 각각 뉴톤-랍슨법(newtonraphson method), 뉴톤-랍슨법과 최소자승법을 이용한 선점법(collocation method)인 수치해석적 방법을 응용하고, 광탄성 등색선 무늬를 컴퓨터 그래픽하여 응력특이성지수와 응력강도계수가 모우드(mode)에 미치는 특성과 경계요소법(boundary element method)으로 응력해석한 결과로써 선점법을 이용하여 응력강도계수를 해석하고 기존의 결과등과 비교, 검토하 고자 한다.

연소기 벽면 막냉각에 주유동의 난류강도가 미치는 영향 (Effect of Mainstream Turbulence Intensity on Film Cooling of Combustor)

  • 김영봉;이동호;조형희;함희철;배주찬;오민근
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2004년도 제23회 추계학술대회 논문집
    • /
    • pp.132-136
    • /
    • 2004
  • 연소실 내부에서 주유동의 난류강도가 엇갈린 배열의 사각홀의 막냉각 성능에 미치는 영향에 대하여 실험을 수행하였으며, 주유동의 $10\%$ 난류강도 하에서 온도장 및 단열 막냉각 효율이 측정되어졌다. 온도장의 결과는 주유동의 높은 난류강도에 의해 전체적인 값들이 감소하고, 두터운 냉각유체 막이 형성됨을 보였으며, 흘 인접영역에서 주유동의 높은 난류강도에 의해 낮은 막냉각 효율 값을 보이지만, 하류로 진행함에 따라 냉각성능의 차이가 줄어듦을 보였다.

  • PDF

이종재 브레이징 계면에서의 균열거동해석 (Analysis of Crack Behavior of dissimilar materials in Brazed Interface By BEM)

  • 오환섭;김시현;김성재
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2001년도 추계학술대회(한국공작기계학회)
    • /
    • pp.269-274
    • /
    • 2001
  • Applications of Brazing in the studying fields such as High-Speed Machining are very increasing in various industry fields. Therefore, Applying to the fracture mechanics by numerical analysis method is very important to analyse the crack problem Dissimilar Materials in Brazed Interface. In this study, Stress intensity Factor (S.I.F) is analysed to investigate crack behavior on the crack tip of dissimilar materials in brazed interface such as a Hardmetal and a HSS by two dimensional(2-D) Boundary Element Method (BEM). Kelvin's solution was used as a fundamental solution in BEM analysis and stress extrapolation method was used to determine Stress Intensity Factor.

  • PDF

타원균열에 작용하는 일반적인 하중에서의 응력확대계수 계산 (Determination of $k_1$in Elliptic Crack under General Ioading Conditions)

  • 안득만
    • 대한기계학회논문집A
    • /
    • 제21권2호
    • /
    • pp.232-244
    • /
    • 1997
  • In this paper weight function theory is extended to the determination of the stress intensity factors for the mode I in elliptic crack. For the calculation of the fundamental fields Poisson's theorem and Ferrers's method were employed. Fundamental fields are constructed by single layer potentials with surface density of crack harmonic fundamental polynimials. Crack harmonic fundamental polynimials up to order four were given explicitly. As an example of the application of the weight function theory the stress intensity factors along crack tips in nearly penny-shaped elliptic crack are calculated.