• 제목/요약/키워드: intensity control

검색결과 2,282건 처리시간 0.036초

음향 인텐시티를 이용한 관 외부 방사 소음의 능동 제어 (Active Control of External Noise Radiated From Duct Using Sound Intensity)

  • 강성우;김양한
    • 소음진동
    • /
    • 제7권3호
    • /
    • pp.427-437
    • /
    • 1997
  • Mean active intensity based active control for the cancellation of radiated noise out of the duct exit is studied. The active intensity control strategy is drerived based on the relation of the exterior sound field out of the duct termination and interior sound field of the duct. One of the characteristics of this control strategy is that the control performance can be maintained regardless of the sensor loction, compared with the conventional local pressure control methods at either interior downstream or exterior field positions. It is also suggested that the digital filtering for the active intensity control can be achieved by time-domain filtered-x LMP (Lest-Mean-Product) adaptive algorithm. Experiments for an open-ended duct are performed to compare the active intensity control performance with conventional pressure control one. Active control experiment of local sound pressure is conducted by widely used filtered-x LMS adaptive Algorithm and active intensity control implementaion uses the derived filter d-x LMP algorithm. It is shown that the exterior sound fileds was much better observable by sensing of the active intensity than by just sound pressure. It is also demonstrated that the global control performance of external field by acoustic intensity is superior to the conventional sound pressure control performance.

  • PDF

Enhancing Astaxanthin Accumulation in Haematococcus pluvialis by Coupled Light Intensity and Nitrogen Starvation in Column Photobioreactors

  • Zhang, Wen-wen;Zhou, Xue-fei;Zhang, Ya-lei;Cheng, Peng-fei;Ma, Rui;Cheng, Wen-long;Chu, Hua-qiang
    • Journal of Microbiology and Biotechnology
    • /
    • 제28권12호
    • /
    • pp.2019-2028
    • /
    • 2018
  • Natural astaxanthin mainly derives from a microalgae producer, Haematococcus pluvialis. The induction of nitrogen starvation and high light intensity is particularly significant for boosting astaxanthin production. However, the different responses to light intensity and nitrogen starvation needed to be analyzed for biomass growth and astaxanthin accumulation. The results showed that the highest level of astaxanthin production was achieved in nitrogen starvation, and was 1.64 times higher than the control group at 11 days. With regard to the optimization of light intensity utilization, it was at $200{\mu}mo/m^2/s$ under nitrogen starvation that the highest astaxanthin productivity per light intensity was achieved. In addition, both high light intensity and a nitrogen source had significant effects on multiple indicators. For example, high light intensity had a greater significant effect than a nitrogen source on biomass dry weight, astaxanthin yield and astaxanthin productivity; in contrast, nitrogen starvation was more beneficial for enhancing astaxanthin content per dry weight biomass. The data indicate that high light intensity synergizes with nitrogen starvation to stimulate the biosynthesis of astaxanthin.

임의의 위치에 가상 인텐시티 형성 방법: 방법론과 그 물리적 의미 (A method to generate virtual intensity at arbitrary position: Methodology and its physical meanings)

  • 최정우;김양한
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.652-657
    • /
    • 2003
  • This paper proposes a method to generate virtual intensity field in space. The sound field of a zone enclosing the listener position is controlled to have maximum acoustic intensity to the desired direction. In order to control acoustic intensity of a zone, space-averaged active intensity is introduced. The ratio of space-averaged active intensity and control effort is defined as a cost function and expressed as a function of source control signals. It is shown that the cost function represents radiation efficiency of multiple sources. The control signals maximizing the cost function is found through eigenvalue analysis. The proposed method is verified by numerical simulations performed in free field condition, and the results provide a relation between wavelength and the size of controllable intensity field.

  • PDF

무한 탄성 평판상의 기준점에 전달되는 진동인텐시티의 능동제어 (Active Control of Vibrational Intensity at a Reference Point in an Infinite, Elastic Plate)

  • 김기만
    • 한국소음진동공학회논문집
    • /
    • 제11권4호
    • /
    • pp.22-30
    • /
    • 2001
  • In this paper, active control of vibrational intensity at a reference point in an infinite, elastic plate was discussed. The plate is excised harmonically by a vibrating source, which has a vertical point force. The optimal condition of controller was investigated to minimize the vibrational intensity being transmitted from the vibrating source to a reference point. Hence the method of feedforward control was employed for the control strategy and then the cost function was evaluated to find the optimal control force. Three types of control force (Vertical force, Moment, and Coupling force (a set of vertical force and moment) ) and controller's positions were examined to define the optimal condition of the controller. The vibrational intensity at a reference point was found to be reduced down to a zero level, compared with the uncontrolled case. Especially maximum reduction of vibrational intensity was achieved when the controller was collinearly positioned between a vibrating source and a reference point.

  • PDF

이산계와 탄성 지지보의 동응답 및 진동 인텐시티 저감을 위한 목적함수 해석 (Analyses of the Cost function for the Reductions of the Dynamic Response and the Vibrational Intensity of a Discrete System and Its Elastic Supporting Beam)

  • 김기만;최성대
    • 한국소음진동공학회논문집
    • /
    • 제20권1호
    • /
    • pp.83-91
    • /
    • 2010
  • In this paper, the feasibility of the cost function having two control factors were discussed in compared to two others which has one different control factor respectively. As of the control factors, the dynamic response of a discrete system and the vibrational intensity at the reference point which is the connecting point of a discrete system to a flexible beam were controlled actively by the control force obtained from the minimization of the cost function. The method of feedforward control was employed for the control strategy. The reduction levels of the dynamic response of a discrete system and the vibrational intensity at a reference point, and also the input power induced by the control force were evaluated numerically in cases of the three different cost functions. In comparison with the results obtained from the cost functions of one control factor, which is the dynamic response or the vibrational intensity, in most cases of the cost function of two control factors the better or similar results were obtained. As a conclusion, it is surely noted that both the dynamic response and the vibrational intensity of the vibrating system be controlled up to the expected level by using the single cost function having two control factors.

COVID-19로 인한 마스크 착용이 보행 속도에 따라 심혈관계 기능에 미치는 영향 (Effects of Mask Wearing Due to COVID-19 on Cardiovascular Function in Treadmill Exercise)

  • 남기원;서동열
    • 대한물리의학회지
    • /
    • 제17권4호
    • /
    • pp.37-43
    • /
    • 2022
  • PURPOSE: To find out how wearing a mask due to COVID-19 affects cardiovascular function as the pace of walking changes. METHODS: Forty-nine college students (27 men, 22 women) were subjected to treadmill exercises without masks (Group I) and wearing masks (Group II). The body temperature, heart rate, oxygen saturation, and blood pressure were measured to determine the changes in cardiovascular function. These parameters were measured at rest (Control I), low-intensity (Control II), medium-intensity (Control III), and high-intensity (Control IV) before and after exercise. RESULTS: Significant differences in heart rate were observed between Control III and Control IV, and a significant difference in oxygen saturation was noted in Control IV. Significant differences in the exercise intensity change in Group II were as follows: Body temperature was Control IV compared to Control I and Control II, heart rate was Control III and Control IV compared to Control I and Control II, and Control IV compared to Control III. The heart rate was Control III and Control IV compared to Control I and Control II, Control IV for Control III, oxygen saturation was Control IV compared to Control I, blood pressure was Control II and Control III and Control IV compared to Control I, and Control IV compared to Control II. CONCLUSION: Exercising when wearing a mask affects the cardiovascular system. Therapists should consider the patient's condition when setting the exercise intensity. In particular, therapists should be more careful when setting the exercise intensity of patients with cardiovascular disease.

복합진동계의 진동 인텐시티 능동 제어 (Active Control of Vibrational Intensity in a Compound Vibratory System)

  • 김기만
    • 한국정밀공학회지
    • /
    • 제19권6호
    • /
    • pp.109-118
    • /
    • 2002
  • The vibrational intensity and the dynamic response of a compound vibratory system had been controlled actively by means of a feedforward control method. A compound vibratory system consists of a flexible beam and two discrete systems - a vibrating source and a dynamic absorber. By considering the interactive motions between discrete systems and a flexible beam, the equations of motion for a compound vibratory system were derived using a method of variation of parameters. To define the optimal conditions of a controller the cost function, which denotes a time averaged power flow, was evaluated numerically. The possibility of reductions of both of vibrational intensity and dynamic response at a control point located at a distance from a source were fecund to depend on the positions of a source, a control point and a controller. Especially the presence of a dynamic absorber gives the more reduction on the dynamic response but the less on the vibrational intensity than those without a dynamic absorber.

Force Sensing Resistor(FSR) Sensor를 이용한 전기인공후두 "Evada"의 기능적 특성에 대한 연구 (A Study on Functional Characteristics of Electrolarynx "Evada" Using Force Sensing Resistor(FSR) Sensor)

  • 박용재;최홍식;이주형;이성민;김광문
    • 대한후두음성언어의학회지
    • /
    • 제9권1호
    • /
    • pp.11-16
    • /
    • 1998
  • Background and Objectives : Electrolarynx has been used as one of the methods of rehabilitation for the laryngectomees. Previous electrolarynx could not alter frequency and intensity simultaneously. This institute developed an electrolarynx named "Evada" using FSR(force sensing resistor) sensor, which can control the frequency(and/or intensity) simultaneously. This study was performed for the normal control and laryngectomees with three types of electrolarynx (Evada, Servox-inton, Nu-vois) to reveal functional characteristics of Evada Materials and Methods : five laryngectomees and five normal adults were made to express there sentences(discriptive sentence, "You stay here" ; question sentence, "You stay here?" ; exclamation sentence, "You!! stay here!"), using three types of electrolarynx. Frequency change and intensity change from first and last vowel was calculated in three sentences and analyzed statistically by paired T-test. Results : The frequency change in the question sentence and exclamation sentence was more prominent in Evada than in Servox-inton and Nu-vois. The intensity change in the question sentence and exclamation sentence was also more prominent in Evada than in Servox-inton and Nu-vois. Conclusions : Evada could control frequency and intensity simultaneously and control degree of frequency(and/or intensity) according to the pressing force into the button. Evada could adjust continuously frequency and intensity during conversation. So, Evada is better in producing intonation and contrastive stress than Nu-vois and Servox-inton.

  • PDF

8주간의 유산소 운동강도에 따른 어린 생쥐의 체중, 식이효율, 뇌의 비만조절 인자(AMPK), 활성산소(MDA), 항산화효소(SOD)의 차이 (Differences in Body Weight, Dietary Efficiency, Brain Obesity Control Factor (AMPK), Reactive Oxygen Species (MDA), and Antioxidant Enzymes (SOD) in Young Mice According to the Intensity of Aerobic Exercise for 8 Weeks)

  • 전미양
    • Journal of Korean Biological Nursing Science
    • /
    • 제23권3호
    • /
    • pp.247-255
    • /
    • 2021
  • Purpose: The goal of this study was to see how different aerobic exercise intensities affected AMP-activated protein kinase (AMPK), reactive oxygen, and antioxidant enzymes in young mice during an 8-week period. Methods: Forty male C57BL/6 mice, aged seven weeks, were randomly assigned to one of four groups: control (n=10), low-intensity exercise (n=10), moderate-intensity exercise (n=10), and high-intensity exercise (n=10). For eight weeks, aerobic activity was performed once a day for 35-40 minutes, five days a week. The data were analyzed using descriptive statistics, analysis of variance (ANOVA), chi-squared tests, and the Tukey test in the SPSS/WIN 25.0 program. Results: Weight (p=.001) was substantially different between the moderate-intensity exercise group and the control group in AMPK (p<.001). In addition, there were no significant differences between the moderate-intensity exercise group and the control group in reactive oxygen malondialdehyde (MDA) levels (p=.136) and antioxidant enzyme superoxide dismutase (SOD) levels (p=.521). Conclusion: These findings suggest that moderate-intensity aerobic exercise increased AMPK activation and helped young mice shed weight.

중소규모 제조업 근로자의 상지 근골격계질환 발생에 영향을 미치는 요인 (Related Factors of Upper Limb Musculoskeletal Disease in Small-to-Medium-sized Manufacture Enterprises Workers)

  • 김혜진;정혜선
    • 한국직업건강간호학회지
    • /
    • 제13권1호
    • /
    • pp.19-29
    • /
    • 2004
  • Purpose: This study was conducted at small-to-medium-sized manufacture enterprises less than 300 employees. Method: For 167 workers in 12 small-to-medium-sized manufacture, we examined the self-recording questionnaires about general characteristics, health characteristics, occupational characteristics and subjective musculoskeletal symptoms designed by NIOSH. Result: Related factors of upper limb musculoskeletal symptoms were found in using of the PC except work, the speed control at working and inappropriate positions for neck, and that using of the PC except work, the degree of intensity at working and the speed control at working for shoulder, and that the degree of intensity at working, the speed control at working, inappropriate positions and excessive workforce for arm/elbow, and that the degree of intensity at working, the speed control at working, inappropriate positions, excessive strong and vibration for hand/wrist/fingers. Conclusion: As a result of multiple logistic regression analysis, musculoskeletal symptoms of neck were influenced by use of the PC except work, household work, and the speed control at working, symptoms of shoulder by using of the PC of except work and the degree of intensity at working, symptoms of arm/elbow by the speed control at working, and symptoms of hand/wrist/fingers by the degree of intensity at work and excessive workforce.

  • PDF