• Title/Summary/Keyword: integrated fire detection

Search Result 30, Processing Time 0.03 seconds

A Study on Integrated Fire Alarm System for Safe Urban Transit (안전한 도시철도를 위한 통합 화재 경보 시스템 구축의 연구)

  • Chang, Il-Sik;Ahn, Tae-Ki;Jeon, Ji-Hye;Cho, Byung-Mok;Park, Goo-Man
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.768-773
    • /
    • 2011
  • Today's urban transit system is regarded as the important public transportation service which saves passengers' time and provides the safety. Many researches focus on the rapid and protective responses that minimize the losses when dangerous situation occurs. In this paper we proposed the early fire detection and corresponding rapid response method in urban transit system by combining automatic fire detection for video input and the sensor system. The fire detection method consists of two parts, spark detection and smoke detection. At the spark detection, the RGB color of input video is converted into HSV color and the frame difference is obtained in temporal direction. The region with high R values is considered as fire region candidate and stepwise fire detection rule is applied to calculate its size. At the smoke detection stage, we used the smoke sensor network to secure the credibility of spark detection. The proposed system can be implemented at low prices. In the future work, we would improve the detection algorithm and the accuracy of sensor location in the network.

  • PDF

A Study on the Fire Safety Measures of Korean Nuclear Power Plants (국내 원자력발전소 화재안전 대책에 관한 연구)

  • 김학중;손봉세;허만성
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2003.04a
    • /
    • pp.259-264
    • /
    • 2003
  • The fire protection system of Nuclear Power Plants(NPPs) is an integrated system that is applied multi-field technology. So, it needs synthetic design and analysis, that is, the plan of fire protection, fire compartment, fire detection, fire suppression, and success of safety shut down, etc. In case of a fire in NPPs, secure the safety of reactor and minimize the radioactivity contamination. For this purpose, perform the fire risk analysis and make up the deducted problem through the improvement of design or the change of operation process.

  • PDF

A Hybrid Fire Fighting Control Intelligent System using Rules and Cases in Integrated Platform Management System (통합플랫폼관리체제에서 규칙 및 사례기반의 하이브리드 화재진압통제 지능시스템)

  • 현우석;김용기
    • Journal of Intelligence and Information Systems
    • /
    • v.6 no.2
    • /
    • pp.15-27
    • /
    • 2000
  • The paper proposes a hybrid fire fighting control intelligent system(H-FFIS) using rules and cases to detect fire in Integrated Platform Management System. By far most conventional systems have been based on rule-based system in which expert knowledges are expressed with production rules. It is hard to express the knowledges to detect fire with production rules only. The knowledges of fire detection are often based on previously encountered situations of fires. For improvement of system capability renewing and adding of rules is needed in an already build-up system and such adding and renewing procedures could hinder users from fluent utilization of the system. We design and implement H-FFIS. Compared with rule-based FFIS(Fire Fighting control Intelligent System), H-FFIS extended with case-based reasoning shows that the system proposed here can lead to an improvement in fire detection rate.

  • PDF

A Plan of Existing System Interface within Station (역사내 기존 시스템 인터페이스 방안)

  • Lee, Won-Jae;An, Tae-Ki;Shin, Jeong-Ryol
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.1550-1555
    • /
    • 2011
  • This paper presents the system interface standard that are associated with additional devices like sensor nodes as well as fire monitoring panel, panic button and emergency call in city railroad environment. Existing fire monitoring panel, panic button and emergency call system is responsible for fire detection and alarm, emergency alarm and communication with the manager. Recently, researches that are associated with NVR-based intelligent integrated surveillance systems and existing alarm system are activated but most of the system is dedicated to it existing. In order to expand devices that is supported other monitoring function, separate device configuration or modification of integrated surveillance system are inevitable. In this study, interface standard between standard controller, integrated command center and each device that facilitate additional expansion of integrated surveillance system and avoid the extra cost is presented.

  • PDF

Test Bed Design of Fire Detection System Based on Multi-Sensor Information for Reduction of False Alarms (화재감지 오보 감소를 위한 다중정보기반 시스템의 Test Bed 설계)

  • Lee, Kijun;Kim, Hyeong Gweon;Lee, Bong Woo;Kim, Tae-Ok;Shin, Dongil
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.6
    • /
    • pp.107-114
    • /
    • 2012
  • Fire detection system is used for detection and alarm-generation of danger in case of fire. Most fire detection systems being used these days often malfunction from false positive and false negative errors. To improve detection reliability, an integrated fire detection algorithm using multi-senor information of heat, smoke and carbon monoxide detectors is suggested, then built and tested using the LabVIEW environment. Simulated using sensor measurement data offered by National Institute of Standards and Technology (NIST), possibility of reducing false positive and false negative errors is verified.

A Design and Implementation of the Intelligent System for the Fire Fighting Control using Fuzzy Logic in Integrated Platform Management System (통합플랫폼관리체제에서 퍼지논리를 이용한 화재진압통제 지능시스템의설게 및 구현)

  • Hyeon, U-Seok;Kim, Yong-Gi
    • The Transactions of the Korea Information Processing Society
    • /
    • v.7 no.7
    • /
    • pp.2095-2107
    • /
    • 2000
  • In maned ship, crews may have risks as they manage damage control system in IPMS in damage situations such as fire in a ship. So the application of unmaned autonomous systms can reduce the number of boarding crews and attribute to safe marine transportation. The paper suggests an intelligent system of the fire fighting control using fuzzy logic in Integrated Platform Management System which can take measures against fire situation of a ship excluding unnecessary warnings with undamaged situations. The system here detected the fire more accurately and adopted more appropriate measures according to ship status compared with conventional systems. Of all, a reduction of false detection of fires was noted.

  • PDF

A Study on the Enhancement of Turbo Decoder Reducing Communication Error of a Fire Detection System for Marine Vessels (선박용 화재탐지장치의 통신 에러를 감소시키기 위한 수정된 터보코딩 알고리즘 개발에 관한 연구)

  • 정병홍;최상학;오종환;김경식
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.25 no.2
    • /
    • pp.375-382
    • /
    • 2001
  • In this study, an adapted Turbo Coding Algorithm for reducing communication error of a fire detection system for marine vessels, especially image transmission via power lone. Because it is necessary that this system communicate larger and faster than previous method, this study carried out enhancement a decoding speed by adaptation CRC with Turbo Code Algorithm, improvement of metric method, and reduction of decoding delay by using of Center-to-Top method. And the results are as follows: (1) Confirmed that a Turbo Code is so useful methods for reducing communication error in lots of noise environments. (2)Proposed technology in this study speed increasing method of Turbo Coding Algorithm proves 2 times faster than normal Turbo Code and communication error reducing as well in the board made by VHDL software & chips ALTERA company.

  • PDF

Design of the Integrated Fire Automation System(IFAS) on based P-Type Fire Control Panel (P형 수신기 기반 통합화재 자동 시스템의 설계)

  • Kim, Hyun-Ju;Park, Jae-Heung;Seo, Yeong-Geon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.15 no.12
    • /
    • pp.133-142
    • /
    • 2010
  • P-type fire control panel, currently in use, has a big hazard that can cause the large scaled human death tolls and property damage in the massive fire because it is difficult to identify in real time the location of fire outbreak and whether search-device are broken down or not. In this paper, I suggest that the integrated fire automation system on based p-type fire control panel should be used, which can detect in real time the signal that occur when whether search-device are broken down or not, and can detect the arisen circumstances information of p-type fire control panel on the fire signal in the far away. The devised systems have designed and embodied the analysis of circumstances information and module that can analyze the circumstances information from the p-type fire control panel and the part of internet access installment which can gather and deliver the circumstances information from the fire prevention facility receiver.

Development of an USN Based Integrated Open Server System for Disaster Prevention Management (USN 기반 개방형 방재관리 통합시스템 개발)

  • Lee, Jeong-Kyoon;Lee, Ki-Young
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.10a
    • /
    • pp.929-932
    • /
    • 2007
  • The integrated prevention of disaster management system is collected prevention of disaster data from prevention of disaster relation other systems and smart sensor in USN. This system manages fire fighting facility effectively. The relation equipment which is used in existing and network using "Open Protocols" about under using the support system which is integrated effectively as the destroyer. It connects CCTV, the sensitivity environmental sensor, automatic fire detection equipment and security equipment and air flow equipment system using Internet. The System Server was collected monitoring data at the each equipment and processing by operational scenario. It will verified the effectiveness of operational scenario and integrated prevention of disaster management system

  • PDF

Introduction of Intelligent fire-disaster Surveillance System for Subway Station (도시철도 역사 지능형 화재감시시스템 구축방안 연구)

  • Shin, Jeong-Ryol;An, Tae-Ki;Jeon, Bo-Ik;Kim, Gab-Young;Kim, Hyung-Min;Yun, Byeong-Ju
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.457-465
    • /
    • 2009
  • Subway system including light-rail transit system is the representative public urban transportation. Accordingly, Nothing is more important than the safety operation as well as passengers' convenience. Due to the fire disaster of Daegu subway on 2003, more strict regulations of detecting fire and of conducting on emergency circumstances. However, regardless of this improved management, it was reported that installations of lots of fire-detection facilities may be harm than good to operate subway system due to frequent malfunction of some fire-detection facilities. It may cause mis-alarm for fire and induces abnormal operation of subway due to the strict regulation; the train shall be stopped on emergency circumstances. Therefore, in this paper, new scheme on surveiling breaking-out-of fire in the station is suggested with new IT technologies, Wireless Sensor Network(WSN) and CCTVs. which were integrated with an intelligent software. This intelligent system enables to surveil breaking-out-of fire in real time through sensor network technology and watch the emergency site on CCTV as well. Through this system, subway organizers could cope with the emergency circumstance rapidly as well as judge precisely whether fire breaks out or not.

  • PDF