Thermal and Water Transmission Properties of Vapor Permeable Water Repellent Fabrics and Thermal Insulation Batting Materials (투습발수직물과 보온단열소재의 열 및 수분전달 특성)

  • Cho Gil Soo;Choi Jong Myoung;Lee Jung Ju;Lee Sern Woo
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.16 no.2
    • /
    • pp.237-244
    • /
    • 1992
  • The purpose of this study was to comparatively evaluate thermal and water transmission properties of several vapor permeable water repellent (VPWR) fabrics and synthetic battings that became available in recent years. Five VPWR fabrics evaluated were Hipora in three coating variants, $Gore-Tex^{\circledR}$ and $Aitace^{\circledR}$. Battings evaluated were $Viwarma^{\circledR}$, $Uniwarmr^{\circledR}$, $Thinsulate^{\circledR}$, and $Airseal^{\circledR}$ Thermal resistance and water vapor transmission were measured for each fabric and batting and in all combinations. Thermal resistance at zero and 37 cm/sec air velocity was determined by the Thermo Labo II technique for simultaneously measuring conduction and radiation heat transfer. Water vapor transmission over 24 hours was measured by a modified weight-gain method in a compact humid chamber at conditions simulating the clothing climate under heavy exercise ($40{\pm}1^{\circ}C$, $90{\pm}2\%$ R.H., and 0.5 m/sec air velocity). Fabric porosity was calculated from fiber density and fabric weight, thickness, and area. Thermal resistance results for the fabrics showed the effectiveness of coatings in inhibiting heat transfer. Measurements taken in wind were: $31.1\~37.6\%$ for $Hipora^{\circledR}$ variants; $31.0\%$ for $Gore-Tex^{\circledR}$; and $18.4\%$ for $Aitaca^{\circledR}$ Measurements without wind were higher but in the same order. Water vapor transmission results were in reverse order: $Aitac^{\circledR}$, $8.8 kg/m^{2};\;Gore-Tex^{\circledR}$, 6.4 kg/$m^{2}$; and $Hipora^{\circledR},\;4.4\~6.0\;kg/m^{2}$. In general thermal resistance increased with porosity. For battings, the thermal resistance with wind results were: $Viwarmu^{\circledR}$, $65.0\%;\; Thinsulate^{\circledR}$, $62.0\%$; $Uniwarm^{\circledR}$, $61.0\%$; and $Airseala^{\circledR},\;53.1\%$. Thermal resistance was proportional to thickness. Thermal resistance of fabric-batting combinations were $20\%$ higher than those of the battings only. Water vapor transmission for combinations was mainly affected by that for the VPWR fabric used.

  • PDF

Production of Foamed Glass by Using Hydrolysis of Waste Glass(III) - Heat Treatment for Stabilization and Scale-up Test - (폐유리의 가수분해 반응에 의한 발포유리의 제조(III) - 안정화 열처리공정 및 Scale-up Test -)

  • Lee, Chul-Tae;Um, Eui-Heum
    • Applied Chemistry for Engineering
    • /
    • v.17 no.1
    • /
    • pp.73-81
    • /
    • 2006
  • Heat treatment condition for the stabilization of foamed glass block through the foaming process of the hydrolized waste glass was investigated and scale-up test for the manufacturing of foamed glass was also attempted for the actual foaming process. Proper heat treatment condition was quenching from the foaming temperature to $550{\sim}600^{\circ}C$ for stabilization, and then annealing from stabilization temperature to $200^{\circ}C$ and holding up at $200^{\circ}C$ for removal thermal stress, and then annealing to the room temperature with cooling speed of $0.3^{\circ}C/min$. Through this heat treatment conditions, foamed glass block with size of $250mm{\times}250mm{\times}90mm$ was produced successfully. The properties of this foamed glass block showed density of $0.28{\pm}0.06g/cm^3$, thermal conductivity of $0.048{\pm}0.005kcal/hm^{\circ}C$, moisture absorption of $0.5{\pm}0.09vol%$, linear expansion coefficient of $(8.6{\pm}0.2){\times}10^{-6}m/m^{\circ}C$($400^{\circ}C$), flexural strength of $15.0{\pm}0.6kg/cm^2$, and compression strength of $39.5{\pm}0.6kg/cm^2$.

Experimental Study on Flow Direction of Fire Smoke in DC Electric Fields (DC 전기장 내에서 발생하는 화재연기 진행 방향에 대한 실험적 연구)

  • Park, Juwon;Kim, Youngmin;Seong, Seung Hun;Park, Sanghwan;Kim, Ji Hwan;Chung, Yongho;Yoon, Sung Hwan
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.5
    • /
    • pp.675-682
    • /
    • 2021
  • Fire accidents on land and at sea can cause serious casualties; specifically, owing to the nature of marine plants and ships, the mortality rate at sea from suffocation in confined spaces is significantly higher than that on land. To prevent such cases of asphyxiation, it is essential to install ventilation fans that can outwardly direct these toxic gases from fires; however, considering the scale of marine fires, the installation of large ventilation fans is not easy owing to the nature of marine structures. Therefore, in this study, we developed a new concept for fire safety technology to control toxic gases generated by fires from applied direct current (DC) electric fields. In the event of a fire, most flames contain large numbers of positive and negative charges from chemi-ionization, which generates an "ionic wind" by Lorentz forces through the applied electric fields. Using these ionic winds, an experimental study was performed to artificially control the fire smoke caused by burning paper and styrofoam, which are commonly used as insulation materials in general buildings and ships. The experiments showed that a fire smoke could be artificially controlled by applying a DC voltage in excess of ±5 kV and that relatively effective control was possible by applying a negative voltage rather than a positive voltage.

Status And Perspectives of Ultra-Lightweight Silica Aerogel Superinsulation Materials (초경량 실리카 에어로젤 초단열재의 현황 및 전망)

  • Dong Jin, Suh
    • Clean Technology
    • /
    • v.28 no.4
    • /
    • pp.301-308
    • /
    • 2022
  • Since nanoporous silica aerogel was first synthesized in 1931, its potential as an ultra-lightweight superinsulation material has been steadily attracting attention. Silica aerogel is the best thermal insulation material to date. However, the potential applications of this lightweight material have so far been hindered by its inherent fragibility and brittleness arising from its ultra-porous nature. Although the monolithic form of silica aerogel has the best ultra-lightweight superinsulation properties, it cannot be used in this form. Instead it is used in the form of powders, particles, and blankets. However, these forms still have shortcomings. Silica aerogel is most widely applied in the form of a fiber-reinforced aerogel blanket, but this form is likely to generate dust when handled. Although silica aerogel particles have been proven to be non-toxic to humans, dust formation remains a major barrier to the widespread application of silica aerogel blankets. This paper will investigate the unique properties of silica aerogel and determine what fields it can be used in or potentially be used in due to its unique properties. In addition, we will review the important advances in silica aerogel synthesis technology and its commercialization so far, and then consider the problems that exist for its widespread commercialization in the future and how to overcome them.

A Rigorous Examination of the Interplay Between Fire Resistance of 1-Hour Rated Fireproof Steel Walls and the Flexural Strength of Individual Panels (1시간 내화구조용 철강재 벽체의 내화성능과 단위 패널 휨강도의 관계 고찰)

  • Jeon, Soo-Min;Ok, Chi-Yeol;Kang, Sung-Hoon
    • Journal of the Korea Institute of Building Construction
    • /
    • v.23 no.5
    • /
    • pp.537-546
    • /
    • 2023
  • For the purpose of fire delineation within buildings, steel walls in Korea are mandated to undergo rigorous certification as fire-resistant entities, substantiated via a series of qualitative assessments. Predominantly, these evaluations comprise the fire resistance test paired with supplementary examinations; specifically for steel walls, these encompass the gas hazard and panel bending strength tests. Given the prevalence of semi-noncombustible core materials, gas hazard tests are largely rendered superfluous, pivoting the focus solely onto the panel bending strength test during the certification trajectory. This particular test is designed to gauge the flexural robustness of individual wall panels. An enhanced bending strength is postulated to fortify both the structural integrity and thermal insulation of the wall by mitigating potential deformations. In this scholarly exploration, an analytical deep dive was undertaken into extant, valid certification test datasets. The endeavor aimed to ascertain the depth of correlation between the designated fire resistance metric and the bending strength, the latter being the sole supplementary assessment for steel walls. In distilling the findings, it was discerned that temperature elevations beyond baseline values exhibited no statistically salient linkage with the panel's bending strength.

A Study on the Thermal Conductivity Measurement for Planting Mats of Landscaping (조경용 식생매트의 열전도율 측정에 관한 연구)

  • Cha, Uk Jin;Yang, Geon Seok
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.46 no.6
    • /
    • pp.85-96
    • /
    • 2018
  • Developed nations have implemented various policies to reduce greenhouse gases since the 1997 Kyoto Protocol in order to minimize the effects of global warming. Korea should also reduce energy consumption in the industrial sector, and the transportation and building sectors in order to achieve its greenhouse gas reduction target of 37 percent compared to the Business As Usual levels. The government implements various laws and regulations for reducing energy consumption. To reduce energy consumption in the building sector, in particular, the Energy Conservation Design Standards are enforced according to the 'Enforcement Support for Green Building Construction'. The amount of electricity used to maintain room temperature at $28^{\circ}C$ in these buildings have a 30% reduction (measured on the walls and rooftop) in power usage compared to buildings not required to meet these standards. Although the effect of these energy savings on landscaping is proven, this demonstration is not effective for energy saving since it is not a suitable method for the 'Energy Saving Design Standards of Buildings'. For landscaping to be effective as far as a component of energy reduction, the perfusion rate of the building should be calculated based on the thermal conductivity of the component materials for the energy saving designs with respect to the basis of Article 14 of the Green Building Act. Therefore, the purpose of this study is to ensure that the planting-based mats currently being widely used in the landscape industry can have insulating performance suitable for the 'Energy Saving Design Standards' of Buildings according to the 'Enable Green Building Construction Methods'.

Development of Summer Leaf Vegetable Crop Energy Model for Rooftop Greenhouse (옥상온실에서의 여름철 엽채류 작물에너지 교환 모델 개발)

  • Cho, Jeong-Hwa;Lee, In-Bok;Lee, Sang-Yeon;Kim, Jun-Gyu;Decano, Cristina;Choi, Young-Bae;Lee, Min-Hyung;Jeong, Hyo-Hyeog;Jeong, Deuk-Young
    • Journal of Bio-Environment Control
    • /
    • v.31 no.3
    • /
    • pp.246-254
    • /
    • 2022
  • Domestic facility agriculture grows rapidly, such as modernization and large-scale. And the production scale increases significantly compared to the area, accounting for about 60% of the total agricultural production. Greenhouses require energy input to create an appropriate environment for stable mass production throughout the year, but the energy load per unit area is large because of low insulation properties. Through the rooftop greenhouse, one of the types of urban agriculture, energy that is not discarded or utilized in the building can be used in the rooftop greenhouse. And the cooling and heating load of the building can be reduced through optimal greenhouse operation. Dynamic energy analysis for various environmental conditions should be preceded for efficient operation of rooftop greenhouses, and about 40% of the solar energy introduced in the greenhouse is energy exchange for crops, so it should be considered essential. A major analysis is needed for each sensible heat and latent heat load by leaf surface temperature and evapotranspiration, dominant in energy flow. Therefore, an experiment was conducted in a rooftop greenhouse located at the Korea Institute of Machinery and Materials to analyze the energy exchange according to the growth stage of crops. A micro-meteorological and nutrient solution environment and growth survey were conducted around the crops. Finally, a regression model of leaf temperature and evapotranspiration according to the growth stage of leafy vegetables was developed, and using this, the dynamic energy model of the rooftop greenhouse considering heat transfer between crops and the surrounding air can be analyzed.