변압기 층간 절연지의 열열화 특성 평가에 관한 연구 (The Study on Characteristics for Thermal Aging of the Layer Insulation in Transformers)

  • 이병성;송일근;김동명;박동배;한상옥
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집
    • /
    • pp.406-409
    • /
    • 2002
  • The primary insulation system used in an oil-filled transformer is Kraft paper, wood, porcelain and, of course, oil. Modern transformers use paper that is chemically treated to improve its tensile strength properties and resistance to aging caused by immersion in oil. These insulation papers are mainly aged to thermal stress. Over the course of the insulation paper and oil's life it is exposed to high temperatures, oxygen and water. Its interaction with the steel of the tank and core plus the copper and aluminium of the windings will eventually cause the chemical properties of the oil to decay. High temperature have an effect on mechanical strength of cellulous paper using the layer insulation. We made two aging cell in which thermal aging tests of insulation papers and mineral oil are conducted. It is measured dielectric strength, number of acid, moisture, etc. of insulation paper and oil aged in the aging cells.

  • PDF

국내원전 단열재 설계특성에 따른 외벽냉각 효과검증 실험 (Experiment on Coolability through External Reactor Vessel Cooling according to RPV Insulation Design)

  • 강경호;박래준;김상백
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.1578-1583
    • /
    • 2003
  • LAVA-ERVC experiments have been performed to investigate the effect of insulation design features on the coolability in case of the external reactor vessel cooling (ERVC). All the 4 tests have been performed using Alumina iron thermite melt as a corium simulant. Due to the limited steam venting through the insulation, steam binding occurred inside the annulus in the KSNP case simulation. On the contrary, in the tests which were performed for simulating the APR1400 insulation design, sufficient water ingression and steam venting through the insulation lead to effective cool down of the vessel characterized by nucleate boiling. It could be found from the experimental results that modification of the insulation design allowing sufficient ventilation could increase the positive effects of the external reactor vessel cooling.

  • PDF

초진공 단열재의 열 물성 특성에 관한 연구 (Thermal Property Characteristics of Super insulation Vacuum Panel)

  • 전현석;최현중;최경석;강재식;이승언
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.599-602
    • /
    • 2009
  • Recently, some major environmental problems are the increase of fossil fuel price and $CO_2$ emission. To solve these problems, it is imperative to develop eco-friendly techniques and to reduce energy consumption in apartment complexes. Therefore, an effective system for insulation needs to be developed to reduce energy consumption. This study compares thermal characteristics between general insulation and super insulation Vacuum Panel, which is thinner and has more insulation efficiency.

  • PDF

바닥충격음 차단성능 평가방법의 KS 규격화 방안 (Korean Industrial Standard of “Rating of floor impact sound insulation for impact source in building and of building elements”)

  • 송민정;장길수;김흥식;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 I
    • /
    • pp.383-386
    • /
    • 2001
  • The KS of “Measurements of impact sound insulation of floors” was established before the years. But the KS of “Rating of floor impact sound insulation for impact source in building and of building elements” is not founded yet. To establish the rating measurement of floor impact sound insulation. The studies on the rating method of domestic floor system of impact sound insulation and response of its inhabitant’s were reviewed. And the rating method of ISO’s and JIS’s were studied in this consideration. The result of this study, KS of “Rating of floor impact sound insulation for impact source in building and of building elements” is proposed.

  • PDF

Optimization approach of insulation thickness of non-vacuum cryogenic storage tank

  • MZAD, Hocine;HAOUAM, Abdallah
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제22권1호
    • /
    • pp.17-23
    • /
    • 2020
  • Cryogenic insulation systems, with proper materials selection and execution, can offer the highest levels of thermal performance. Insulations are listed in order of increasing performance and, generally, in order of increasing cost. The specific insulation to be used for a particular application is determined through a compromise between cost, ease of application and the effectiveness of the insulation. Consequently, materials, representative test conditions, and engineering approach for the particular application are crucial to achieve the optimum result. The present work is based on energy cost balance for optimizing the thickness of insulated chambers, using foamed or multi layered cryogenic shell. The considered insulation is a uniformly applied outer layer whose thickness varies with the initial and boundary conditions of the studied vessel under steady-state radial heat transfer. An expression of the optimal insulation thickness derived from the total cost function and depending on the geometrical parameters of the container is presented.

세척과 절연보강에 따른 고압전동기 고정자 권선의 절연상태 분석 (Analysis of Insulation Condition in High Voltage Motor Stator Windings Following Cleaning and Insulation Reinforcement)

  • 김희동
    • 한국전기전자재료학회논문지
    • /
    • 제25권6호
    • /
    • pp.474-480
    • /
    • 2012
  • Diagnostic tests were performed on two high voltage(HV) motor stator windings. These tests included the measurement of insulation resistance, polarization index, AC current, dissipation factor($tan{\delta}$) and partial discharge(PD) magnitude. Surface contamination of HV motor stator windings has an effect on the AC current and $tan{\delta}$. When the stator windings were finished cleaning and insulation reinforcement, the increase rate of AC current(${\Delta}I$) and dissipation factor(${\Delta}tan{\delta}$) were very small compared to those before cleaning. However, the PD magnitude remained the same. These tests show that cleaning and insulation reinforcement of HV motor stator windings can reduce the insulation failure.

인버터 서지와 온도 스트레스 하에서 Magnet Wire 절연 수명평가 (Insulation Life Estimation for Magnet Wire Under Inverter Surge and Temperature Stress)

  • 박재준
    • 한국전기전자재료학회논문지
    • /
    • 제29권10호
    • /
    • pp.641-646
    • /
    • 2016
  • Coil specimen was prepared by coating a copper wire with two varnish thin layers: the first was polyamideimide (PAI)/nanosilica (5 wt%) varnish and the second was anti-corona PAI/nanosilica (15 wt%) varnish. Insulation breakdown voltage was investigated under inverter surge condition at $20^{\circ}C$, $70^{\circ}C$, $100^{\circ}C$, $150^{\circ}C$, $200^{\circ}C$, $250^{\circ}C$, respectively. The insulation lifetime of the two layered coil was tens of times longer than that of original PAI coil. And the insulation lifetime decreased with increasing ambient temperature because there was weak binding strength between copper and varnish layer.

생애비용 분석을 통한 외벽 및 단열재료 종류별 냉동냉장창고 외피의 적정 단열두께 산정 (Optimized Insulation Thickness of the Refrigerated Warehouse with Different Envelope Structures and Insulation Materials by L.C.C. Analysis)

  • 강승희;구보경;황혜주;석호태;안홍섭;송승영
    • 설비공학논문집
    • /
    • 제15권5호
    • /
    • pp.372-381
    • /
    • 2003
  • This study aims to find out the optimized insulation thickness of refrigerated warehouse with different envelope structures (RC and PC wall) and insulation materials (urethane and icynene). Each of them is compared according to the thickness of insulation (100, 150, 200 mm/50 or 250 mm) and the temperature of cold storage room (0, -6, -15$^{\circ}C$). As results, it is proved to have the best economical efficiency in life cycle cost when PC wall with thickness of 100 mm (0 and -6$^{\circ}C$) and 150 m (-15$^{\circ}C$) urethane, respectively, are applied.

공동주택에서 중공 슬래브 바닥의 차음 특성에 관한 연구 (A Study on the Characteristics of Sound Insulation at the Circular Voided Concrete Floor in the Multi-Housing)

  • 손철수
    • 한국주거학회논문집
    • /
    • 제11권1호
    • /
    • pp.171-181
    • /
    • 2000
  • The purpose of the resent research is to investigate the characteristics of sound insulation at the circular voided concrete slab in the multi-housing. In order to do this research, the method for field measurement of floor impact sound level was used following the Korea Standard F2810-1996. For the multi-housing, three kinds of circular voided concrete slabs are used to measure the characteristics of sound insulation.The results are as follows; 1.The main factor affecting the characteristics of sound insulation at the circular voided concrete slab in the multi-housing is sound-absorbing materials in the circular tube. 2. The main factor to effect the difference of sound pressure level is circular tube in the concrete slab. 3. The forms of circular tubes effect the characteristics of sound insulation at the circular tube. 4. Sound Pressure Level resulting from the piping direction of circular tubes in little different to octave band level.More study will be needed about the depth and distance of sound insulation materials, and the components of sound insulation materials for the multi-housing.

  • PDF

절연파괴 사례분석을 통한 진공함침 방식 발전기 고정자권선의 절연특성 연구 (A Study on Insulation Property of VPI Type Generator Stator Winding Through the Case Analysis of Insulation Breakdown)

  • 공태식
    • 전기학회논문지P
    • /
    • 제59권3호
    • /
    • pp.311-316
    • /
    • 2010
  • According to increase of combined cycle power generation, the manufacturing market of gas turbine generator has become more competitive, so there is high pressure on the manufacturer to reduce generator price. Global VPI(vacuum pressure impregnation) method is effective to save the production cost and time for manufacturing stator windings, but it has an abrasion problem by vibration between stator windings and slots. This paper presents the insulation breakdown case, which is for VPI type generator during high voltage insulation tests, and also shows the cause analysis, repair works as well as reliability test. the purpose of this paper is to understand the insulation properties of VPI type generator and to know prevention of insulation weakness.