• Title/Summary/Keyword: instruments

검색결과 4,921건 처리시간 0.026초

국내 작업환경측정기관의 측정 및 분석장비 보유실태에 대한 고찰 (I) (Evaluation of the Possession of Measurement and Analytical Instruments among Domestic Work Environment Monitoring Service Providers (I))

  • 장재길
    • 한국산업보건학회지
    • /
    • 제23권3호
    • /
    • pp.250-260
    • /
    • 2013
  • Objectives: The aim of this study is to analyze the current status of the possession of measurement and analytical instruments among work environment monitoring organizations that have been designated by the Ministry of Employment and Labor (MoEL) in Korea. Methods: Data for measurement and analytical instruments were gathered by inspectors who had been assigned by the Korea Occupational Safety and Health Agency (KOSHA) and MoEL during the evaluation program for designated work environment monitoring service providers in 2012. Data for 11 monitoring instruments and nine analytical instruments were collected from 108 organizations. Basic data such as the type of service provides and the size of employment were also recorded by the inspector. Results: The total number of personal air samplers including high and low flow rates operated in Korea was 5,418, with average of 50.2. Average operation number of noise dosimeters was 35.0, while 3,780 dosimeters were used in 108 work environment monitoring organizations. There were 10,488 monitoring instruments in total. All service providers possessed at least one AAS and GC in their analytical laboratory. Total number of HPLC/MS was five, followed by ICP/MS of seven, with an average of 0.07. Conclusions: Based on the data, domestic work environment monitoring service providers possessed relatively reasonable measurement and analytical instruments. Nearly all instruments had been imported from advanced countries such as USA, UK and Japan. Periodic gathering of data on these instruments may help maintain good workplace monitoring results and the health of workers at the sites.

Thermo-optic Characteristics of Micro-structured Optical Fiber Infiltrated with Mixture Liquids

  • Wang, Ran;Wang, Yuye;Miao, Yinping;Lu, Ying;Luan, Nannan;Hao, Congjing;Duan, Liangcheng;Yuan, Cai;Yao, Jianquan
    • Journal of the Optical Society of Korea
    • /
    • 제17권3호
    • /
    • pp.231-236
    • /
    • 2013
  • We present both theoretically and experimentally the thermo-optic characteristics of micro-structured optical fiber (MOF) filled with mixed liquid. The performance of MOF depends on the efficient interaction between the fundamental mode of the transmitted light wave and the tunable thermo-optic materials in the cladding. The numerical simulation indicates that the confinement loss of MOF presents higher temperature dependence with higher air-filling ratios $d/{\Lambda}$, longer incident wavelength and fewer air holes in the cladding. For the 4cm liquid-filled grapefruit MOF, we demonstrate from experiments that different proportions of solutions lead to tunable temperature sensitive ranges. The insertion loss and the extinction ratio are 3~4 dB and approximate 20 dB, respectively. The proposed liquid-filling MOF will be developed as thermo-optic sensor, attenuator or optical switch with the advantages of simple structure, compact configuration and easy fabrication.

치과용 소형 C자형 투시장치를 이용한 하악 연조직에 위치한 부러진 기구의 제거: 증례보고 (Removal of Broken Instruments in Soft Tissue at Mandibular Area Using a Dental Mini C-arm: Case Reports)

  • 박성수;양훈주;황순정
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제32권6호
    • /
    • pp.567-572
    • /
    • 2010
  • Intraoperative breakage of instruments can be occurred unexpectedly. To prevent damage of neighboring important anatomic structures and consequent complications, broken instruments should be removed as soon as possible. There have been several methods to remove broken instruments. One of them is the Carm fluoroscopy which is commonly used for locating metal foreign bodies. However, its application for removal of broken instruments in the oral and maxillofacial area is not common. In our experiences with the removal of two broken instruments in mandibular area, the newly developed dental mini C-arm was used to find broken instrument in soft tissue, because it gives real-time in situ information for the intraoperative location. We report two cases with broken instruments, a broken dental needle in the pterygomandibular space and a broken straight bur in the mandibular angle area. They were identified and could be removed safely using a dental mini C-arm.

아동학대 평가도구의 체계적 고찰 (A Systematic Review of Child Abuse Screening Instruments)

  • 김현경;최혜미;박현정
    • Child Health Nursing Research
    • /
    • 제22권4호
    • /
    • pp.265-278
    • /
    • 2016
  • Purpose: The aim of this study was to conduct a systematic review and to describe the characteristics of child abuse screening instruments. Methods: Articles regarding the development of a child abuse screening instrument were investigated using the systematic review method. A literature search using the keywords "child and abuse or maltreatment and instrument or screening tool" in English, and "child," "abuse," and "instrument" in Korean, was conducted of material published in PubMed, PsycINFO, CINAHL, SCOPUS, ERIC, and RISS. Database and bibliographic searches, and quality appraisal using the Quality Assessment of Diagnostic Accuracy Studies tool that included systemic reviews, yielded 17 records. Results: Key elementary child abuse screening instruments were developed for physical, psychiatric, affective and sexual and child neglect assessment. The instruments' target populations were children at home and in institutions. The reviewed instruments had the advantage of diagnosing past, concurrent, and indirectly, potential child abuse. Conclusion: The results of this study demonstrate that child abuse screening instruments are available for screening and for assessment of abused children in various circumstances. This review of child abuse screening instruments offers evidence for the acceptable use of optimal psychometric tools for child abuse assessment and provides guidelines for child health nursing practice.

과학의 본성에 대한 검사 도구를 활용한 연구의 개관과 분석(1990~2009) (A Review and Analysis of the Studies using Instruments on the Nature of Science(1990~2009))

  • 나지연;송진웅
    • 한국초등과학교육학회지:초등과학교육
    • /
    • 제29권3호
    • /
    • pp.292-306
    • /
    • 2010
  • The purpose of this study was to review the current state and characteristics of instruments used to assess individual understanding of the nature of science (NOS). This study conducted a series of content analyses of the articles published in a total of seven Korean and international journals from 1990 to 2009. A total of 99 research papers and assessment tools were categorized according to their features such as item type, the method of development, philosophical perspectives and others. So, evaluation domains of the instruments were also compared with the features of the NOS endorsed in some standards science education documents internationally well known, such as Benchmarks for Science Literacy (AAAS, 1993), National Science Education Standards (NRC, 1996). It was found that VNOS was the most frequently used instrument used for the last 20 years. There was a difference between characteristics of instruments used in Korean journals and these in international journal, such as philosophical perspectives, item type. Moreover, the results showed that there were only a few of instruments to ask about ethics of scientists, significance of science process skill and the context. NOS instruments focused only on limited aspects of NOS emphasized by the standard documents.

  • PDF

항공기 계기판의 적정배열을 위한 인간공학적 연구 (A Human Factors Study in Instrument Panel Layout of the Korean Air Force Aircraft.)

  • 박종선
    • 한국국방경영분석학회지
    • /
    • 제2권1호
    • /
    • pp.127-143
    • /
    • 1976
  • The purpose of this thesis is to study the optimal arrangement of aircraft instrument panels through the human factors approach. Human factors engineering is the process of effectively fitting the human component to the machine component in any man-machine system. The human factors. are especially important to an aircraft pilot who must constantly shift his attention between the instrument panel within the cockpit and the surrounding area of the aircraft. The preliminary part of this study is to find the general patterns of the Korean pilot's eye movements during their various flying maneuvers, and which instruments require the most attention while in flight. It is assumed that all pilots have a general pattern of eye movement when observing the aircraft instrument panel and that an optimum arrangement would be to minimize the eye travel distance between instruments. In this thesis the arrangements of instruments is taken to be the independent variable and the eye travel distance between instruments the dependent variable. la order to compile the information necessary for this study, sixty Korean Air Force pilots were interviewed and requested to complete information forms. These information forms listed various flying maneuvers and listed each instrument used on the instrument panel. The compilation of the information on these completed forms listed the instruments most frequently used by the pilots. The second part of this study was to determine the optimum instrument arrangement. It was necessary to study the various number of possible arrangements of instruments depending upon the number of instruments involved. Therefore, these instruments are grouped by two major functions, The flight instruments were subdivided into three groups, and the engineering instruments were subdivided into six groups. With this subdivision we arrive at the possible number of arrangements of 4,320. Through the simulation method, total eye travel distance for each of these 4,320 arrangements is calculated and the arrangement which appears to be of optimum distance between the most frequently used aircraft instruments is determined. The results of this study indicate that the optimum distance between instruments would be 33,028cm and that the corresponding distance of the instrument panel now being used is 34,288cm. Therefore, an increased efficiency of $3.8\%$ would be realized if the existing aircraft instrument panel were re-arranged according to layout proposed in this thesis.

  • PDF

국악관악기 품질평가를 위한 음고특성분석 (Frequency Characteristics Analysis for Quality Assessment on Korean Traditional Wind Instruments)

  • 박수홍;옥승호;서인화;김소리;정환희
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2011년도 춘계학술대회 논문집
    • /
    • pp.302-307
    • /
    • 2011
  • In this study, peak frequencies of korean traditional wind instruments according to instruments were measured for introducing quality certification system. Also major dimensions of instruments were measured too, for analysis on manufacturing precesion.

  • PDF

Canal preparation with nickel-titanium or stainless steel instruments without the risk of instrument fracture: preliminary observations

  • Yared, Ghassan
    • Restorative Dentistry and Endodontics
    • /
    • 제40권1호
    • /
    • pp.85-90
    • /
    • 2015
  • This report introduces a novel technique that allows a safe and predictable canal negotiation, creation of a glide path and canal preparation with reciprocating nickeltitanium or stainless steel engine-driven instruments in canals where the use of rotary and the newly developed reciprocating instruments is contraindicated. In this novel technique, the instruments are used in reciprocating motion with very small angles. Hand files are not used regardless of the complexity of the canal anatomy. It also allows achieving predictable results in canal negotiation and glide path creation in challenging canals without the risk of instrument fracture.

LightSpeed and SimpliFil : Designed for Successful Endodontics

  • Senia, Steve
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2001년도 춘계학술대회
    • /
    • pp.259-259
    • /
    • 2001
  • ;A new root canal instrument and instrumentation technique: a preliminary report. Cleaning and shaping the root canal system has been and continues to be a challenge for even the most experienced endodontist. Curved. narrow canals. in particular. cause difficulties for the beginner as well as the specialist. A new instrument designed to incorporate new concepts was developed to ameliorate the problems in cleaning and shaping root canal systems. This new instrument has been given the name of SW (Senia and Wildey). The new SW instrument uses controlled right and left rotational forces. This motion was used to clean and shape simulated root canals in plastic blocks and root canals in extracted teeth. Instrumentation appeared to be easier. faster. and more precise than with conventional instruments. especially in curved canals where there was remarkable reduction of canal transportation. A mechanical version of the SW instrument was also developed. It was used to flare the coronal portion of the root canal system. Wildey WL. Senia ES., Oral Surg Oral Med Oral Pathol1989 Feb:67(2):198-207 Another look at root canal instrumentation. Several aspects of root canal instrumentation need additional research. Various factors must be considered in an analysis of instrumentation of the root canal system: the dentin that is cut: the technique used to cut it: the design of the instruments: the material and manufacturing process used to make the instruments: the irrigant used during the procedure: and the anatomic configuration of the root canal system. An analysis of these factors clearly indicates that existing root canal instruments and techniques are less than ideal and. in fact. do not accomplish what is expected of them. Root canals must be properly. but. at the same time. destructive and unnecessary removal of dentin should be kept to a minimum. The Flex-R and Canal Master instruments were developed to address some of the shortcomings of existing instruments and techniques. More scientifically based research is needed to fully evaluate these new instruments and techniques and to develop future instruments. Wildey WL; Senia ES. Montgomery S., Oral Surg Oral Med Oral Pathol1992 Oct:74(4):499-50799-507

  • PDF

2015 개정 교육과정의 정보과 핵심역량에 관한 검사도구 분석 (Analyzing the Instruments on core competencies of the 2015 Revised Informatics Curriculum)

  • 우호성;김자미;이원규
    • 컴퓨터교육학회논문지
    • /
    • 제21권2호
    • /
    • pp.49-58
    • /
    • 2018
  • 역량은 지식이나 기능보다 확장된 개념으로 다양한 문제를 효율적이고 합리적으로 해결하는 능력을 의미한다. 본 연구는 2015 정보과 개정 교육과정에서 제시된 핵심역량에 주목하여, 핵심역량을 측정할 수 있는 국내외 검사도구의 구성 방법 및 내용 구성을 분석하기 위한 목적이 있다. 국가 및 기관에서 개발한 12개 검사 도구를 분석한 결과, 컴퓨팅 사고력, 정보문화소양, 협력적 문제해결력을 기준으로 9개 검사 도구는 두 가지 이상의 역량을 측정하고 있었으며, 3개의 검사 도구는 한 가지 역량만을 측정하고 있었다. 10개의 검사 도구는 컴퓨터 기반검사를 시행하고 있으며, 객관식, 주관식, 서술식 중 2가지 이상의 형태로 문항을 개발한 검사도구가 50%를 차지하였다. 본 연구는 정보과 교육으로 길러지게 될 역량을 진단하기 위한 검사 도구의 개발 방향에 중요한 단초를 제공했다는 점에 의의가 있다.