• 제목/요약/키워드: instruments

검색결과 4,895건 처리시간 0.027초

Cyclic fatigue life of Tango-Endo, WaveOne GOLD, and Reciproc NiTi instruments

  • Yilmaz, Koray;Ozyurek, Taha
    • Restorative Dentistry and Endodontics
    • /
    • 제42권2호
    • /
    • pp.134-139
    • /
    • 2017
  • Objectives: To compare the fatigue life of Tango-Endo, WaveOne GOLD, and Reciproc NiTi instruments under static model via artificial canals with different angles of curvature. Materials and Methods: Reciproc R25, WaveOne GOLD Primary, and Tango-Endo instruments were included in this study (n = 20). All the instruments were rotated in artificial canals which were made of stainless steel with an inner diameter of 1.5 mm, $45^{\circ}$, $60^{\circ}$, and $90^{\circ}$ angles of curvatures and a radius of curvature of 5 mm until fracture occurred, and the time to fracture was recorded in seconds using a digital chronometer. The data were analyzed using Kruskal-Wallis and post-hoc Dunn tests were used for the statistical analysis of data in SPSS 21.0 software. Results: Tango-Endo files were found to have significantly higher values than WaveOne GOLD and Reciproc files in terms of fatigue life (p < 0.05). However, there was no statistically significant difference between fatigue life of Reciproc and WaveOne GOLD files (p > 0.05). It was determined that increasing the angle of curvature of the stainless canals caused significant decreases in fatigue life of all of three files (p < 0.05). Conclusions: Within the limitations of the present study, the cyclic fatigue life of Tango-Endo in canals having different angles of curvature was statistically higher than Reciproc and WaveOne GOLD.

Measurement Instruments for Superior Product Development: A Case Study of Deli Serdang Cassava in Indonesia

  • P, Remus Hasiholan;TARMIZI, Hasan Basri;RAHMANTA, Rahmanta;PURWOKO, Agus
    • The Journal of Asian Finance, Economics and Business
    • /
    • 제8권5호
    • /
    • pp.1139-1145
    • /
    • 2021
  • This study is aimed at developing a measurement instrument for the superior product development program of Deli Serdang cassava, Indonesia. This research population is the target population of Deli Serdang Micro, Small and Medium-sized Enterprises (MSMEs) which produces cassava. The sample was randomly selected and consisted of 300 MSMEs. The study method is research and development with confirmatory factor analysis using Amos software. The data collection technique was a questionnaire. Study results used the maximum likelihood method which showed that the validity and reliability instruments met the ideal loading factor value > 0.5 and a significance value of p (0.000). The model built also meets the fit criteria based on the Goodness of Fit Model Standard. All instruments are presented to build and measure the superior cassava product development program by Deli Serdang MSMEs. This superior product development program comprises (1) economic contribution (with a loading factor value of 0.76) (2) social aspects (with a loading factor value of 0.76) (3) cultural aspects (with a loading factor value of 0.99) and (4) institutional (with a loading factor value of 0.87). This result means that all instruments have proven construct validity.

The top 10 most-cited articles on the management of fractured instruments: a bibliometric analysis

  • Mishra, Lora;Kim, Hyeon-Cheol;Singh, Naomi Ranjan;Rath, Priti Pragati
    • Restorative Dentistry and Endodontics
    • /
    • 제44권1호
    • /
    • pp.2.1-2.6
    • /
    • 2019
  • Objectives: The purpose of this research was to identify the top 10 most-cited articles on the management of fractured or broken instruments and to perform a bibliometric analysis thereof. Materials and Methods: Published articles related to fractured instruments were screened from online databases, such as Web of Science, Scopus, PubMed, and ScienceDirect, and highly cited papers, with at least 50 citations since publication, were identified. The most-cited articles were selected and analysed with regard to publication title, authorship, the journal of publication, year, institution, country of origin, article type, and number of citations. Results: The top 10 most-cited articles were from various journals. Most were published in the Journal of Endodontics, followed by the International Endodontic Journal, and Dental Traumatology. The leading countries were Australia, Israel, Switzerland, the USA, and Germany, and the leading institution was the University of Melbourne. The majority of articles among the top 10 articles were clinical research studies (n = 8), followed by a basic research article and a non-systematic review article. Conclusions: This bibliometric analysis revealed interesting information about scientific progress in endodontics regarding fractured instruments. Overall, clinical research studies and basic research articles published in high-impact endodontic journals had the highest citation rates.

The Impact of Fiscal Policy Instruments on Economic Wellness: Evidence From Malaysian Per Capita Income

  • OTHMAN, Nor Salwati;TAI, Teh Lian
    • The Journal of Asian Finance, Economics and Business
    • /
    • 제9권6호
    • /
    • pp.245-252
    • /
    • 2022
  • This study examines the strength of the impact of fiscal policy tools on economic wellbeing as measured by per capita income in Malaysia from 1996 to 2020. The impact of fiscal policy instruments on economic wellness, represented by real income per capita, is measured using the autoregressive distributed lags model. The speed of adjustment from short-run disequilibrium to long-run equilibrium is also measured to assess the strength of the fiscal instruments' impact on per capita income. Empirical results exhibit the existence of co-integration relationships between per capita income, tax revenue, and government spending. The findings provide strong support for the presence of a long-run positive impact on government spending and a long-run negative impact of tax revenue on per capita income. The coefficient of ECTt-1 indicates that deviations from a short-run disequilibrium to a long-run equilibrium from the current to the future period are corrected with a speed of 76% (equivalent to a duration of 1.5-2 years to return to equilibrium). The practical and policy implication of the results is fiscal instruments play a significant role, mainly in alleviating the economic impact of the COVID-19 pandemic in the long run.

The effects of autoclave sterilization on the cyclic fatigue resistance of ProTaper Universal, ProTaper Next, and ProTaper Gold nickel-titanium instruments

  • Ozyurek, Taha;Yilmaz, Koray;Uslu, Gulsah
    • Restorative Dentistry and Endodontics
    • /
    • 제42권4호
    • /
    • pp.301-308
    • /
    • 2017
  • Objectives: It was aimed to compare the cyclic fatigue resistances of ProTaper Universal (PTU), ProTaper Next (PTN), and ProTaper Gold (PTG) and the effects of sterilization by autoclave on the cyclic fatigue life of nickel-titanium (NiTi) instruments. Materials and Methods: Eighty PTU, 80 PTN, and 80 PTG were included to the present study. Files were tested in a simulated canal. Each brand of the NiTi files were divided into 4 subgroups: group 1, as received condition; group 2, pre-sterilized instruments exposed to 10 times sterilization by autoclave; group 3, instruments tested were sterilized after being exposed to 25%, 50%, and 75% of the mean cycles to failure, then cycled fatigue test was performed; group 4, instruments exposed to the same experiment with group 3 without sterilization. The number of cycles to failure (NCF) was calculated. The data was statistically analyzed by using one-way analysis of variance and post hoc Tukey tests. Results: PTG showed significantly higher NCF than PTU and PTN in group 1 (p < 0.05). Sterilization significantly increased the NCF of PTN and PTG (p < 0.05) in group 2. PTN in group 3 had significantly higher cyclic fatigue resistance than PTN group 4 (p < 0.05). Also, significantly higher NCF was observed for PTG in group 2 than in groups 3 and 4 (p < 0.05). Conclusions: PTG instrument made of new gold alloy was more resistant to fatigue failure than PTN and PTU. Autoclaving increased the cyclic fatigue resistances of PTN and PTG.

Influence of scaling procedures on the integrity of titanium nitride coated CAD/CAM abutments

  • Gehrke, Peter;Spanos, Emmanouil;Fischer, Carsten;Storck, Helmut;Tebbel, Florian;Duddeck, Dirk
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권3호
    • /
    • pp.197-204
    • /
    • 2018
  • PURPOSE. To determine the extent of treatment traces, the roughness depth, and the quantity of titanium nitride (TiN) removed from the surface of CAD/CAM abutments after treatment with various instruments. MATERIALS AND METHODS. Twelve TiN coated CAD/CAM abutments were investigated for an in vitro study. In the test group (9), each abutment surface was subjected twice (150 g vs. 200 g pressure) to standardized treatment in a simulated prophylaxis measure with the following instruments: acrylic scaler, titanium curette, and ultrasonic scaler with steel tip. Three abutments were used as control group. Average surface roughness (Sa) and developed interfacial area ratio (Sdr) of treated and untreated surfaces were measured with a profilometer. The extent of treatment traces were analyzed by scanning electron microscopy. RESULTS. Manipulation with ultrasonic scalers resulted in a significant increase of average surface roughness (Sa, P<.05) and developed interfacial area ratio (Sdr, P<.018). Variable contact pressure did not yield any statistically significant difference on Sa-values for all instruments (P=.8). Ultrasonic treatment resulted in pronounced surface traces and partially detachment of the TiN coating. While titanium curettes caused predominantly moderate treatment traces, no traces or detectable substance removal has been determined after manipulation with acrylic curettes. CONCLUSION. Inappropriate instruments during regular plaque control may have an adverse effect on the integrity of the TiN coating of CAD/CAM abutments. To prevent defects and an increased surface roughness at the transmucosal zone of TiN abutments, only acrylic scaling instruments can be recommended for regular maintenance care.

조선시대 간의대의 배치와 척도에 대한 추정 (INFERENCE ON THE ARRANGEMENT AND SCALE OF THE GANUIDAE IN THE JOSEON DYNASTY)

  • 김상혁;민병희;안영숙;이용삼
    • 천문학논총
    • /
    • 제26권3호
    • /
    • pp.115-127
    • /
    • 2011
  • Since the thirteenth century, large scale facilities and various instruments for astronomical observation were built and installed in East Asia. During the Yuan Dynasty, S. ti.ntai (Beijing astronomical observatory in the Yuan Dynasty, 司天臺) was built in Beijing in 1279. Various astronomical instruments, including Ganui (Jianyi, simplified armillary sphere, 簡儀), Yang-yi (upward hemisphere, 仰儀) and Gyupyo (gnomon, 圭表) were installed in this observatory. These astronomical instruments were modified and improved by researchers of the Joseon Dynasty. Ganuidae (Joseon astronomical observatory, 簡儀臺) was built in Gyeongbokgung (or Gyeongbok palace, 景福宮), Seoul. Its scale was 31 Cheok (Korean feet in the Joseon Dynasty, 尺) in height, 47 Cheok in length and 32 Cheok in width. Lee, Cheon (李蕆, 1376~1451), a responsible leader of Ganuidae project, set up various astronomical instruments with his colleagues. Ganui and Jeongbangan (direction-determining board, 正方案) were installed at the top of this observatory. Gyupyo was installed at the west side of this observatory and Honui (armillary sphere, 渾儀) and Honsang (celestial globe, 渾象) were installed in a small pavilion which was located next to Gyupyo. A decade after installation, this observatory was moved to the north-west side of the palace but almost destroyed during Japanese invasion of Korea in 1592 except Ganuidae. We have analyzed documents about Ganuidae and investigated Chinese remains of astronomical observatories and artifacts of astronomical instruments. In this paper, we suggest the appearance, structure, arrangement and scale of Ganuidae, which are expected to be used for the restoration of Ganuidae at some day in the near future.

방사선사의 직무 스트레스 측정도구 개발을 위한 요인별 신뢰도 분석 (An Analysis of Reliability by Factors for Development of Job Stress Measurement Tools of Radiological Technologists)

  • 정홍량;손부순;임청환
    • 한국환경보건학회지
    • /
    • 제32권2호
    • /
    • pp.103-110
    • /
    • 2006
  • The present study is designed to analyze reliability and validity of the instruments used to measure job stress of radiological technologists mainly by means of the questionnaires from 'Korean edition of NIOSH check list'. The subjects of this study are 890 radiological technologists active at 44 general hospitals in 16 provinces and cities across the country. The item-total reliability revealed that 10 factors in 6 are the major causes of stress in job life of radiological technologists. The measuring instrument proved to be valid with reliability coefficient of internal consistency by factors being more than 0.7. The factors found to be applicable herewith include limit and authority of job (0.73), cohesion within departments (0.86), resources control (0.81), mental requirements (0.85), job load (0.82), and job stability (0.72). When job autonomy item of causes are modified for proper use to radiological technologists, the measuring instruments are expected to show high reliability. It seems, however, necessary to develop a measuring instrument to analyze and use the validity of related measuring instruments since the reliability here was rated low, with statistical coefficients lower than 0.7 in such factors as job management (0.57), conflicts within departments (-1.13), sense of responsibility for patients (0.66) and usage of education (0.26). As this study was intended to examine reliability and validity of the concepts related to measurement of job stress on the part of radiological technologists, it nay not be proper to apply the results of this study to general use, but is advised to utilize them as basis for developing instruments to verify reliability and validity by comparing with and analyzing other measuring instruments.

Health-related Quality of Life in Women with Breast Cancer: a Literature-based Review of Psychometric Properties of Breast Cancer-specific Measures

  • Niu, Hui-Yan;Niu, Chun-Ying;Wang, Jia-He;Zhang, Yi;He, Ping
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권8호
    • /
    • pp.3533-3536
    • /
    • 2014
  • Background: Breast cancer is one of the most common cancers in women in the world. Health-related quality of life (HRQL) at treatment endpoint in cancer clinical trials is widely considered to be increasingly important. The aim of this review was to provide a literature-based assessment of the validity, reliability and responsiveness of breast cancer-specific HRQL instruments in women breast cancer patients. Materials and Methods: The databases consulted were Medline, PubMed, and Embase. The inclusion criteria required studies to: (1) involve use of HRQL measures; (2) cover women with breast cancer under standard treatment (surgery, radiation therapy, chemotherapy, hormone therapy, and targeted therapy); (3) involve the validity, reliability, or responsiveness of HRQL; (4) deal with validation of breast cancer-specific HRQL instruments. Results: A total of 16 studies were identified through the literature search that met the 4 inclusion criteria. Some seven instruments were assessed among these 16 studies: EORTC QLQ-BR23, FACT-B, FACT-ES, HFRDIS, LSQ-32, QLICP-BR, and SLDS-BC. EORTC QLQ-BR23, FACT-B, LSQ-32, QLICP-BR, and SLDS-BC are more general breast cancer-specific HRQL instruments. FACT-EB is the endocrine subscale combined with FACT-B in order to measure the side effects and putative benefits of hormonal treatment administered in breast cancer patients. HFRDIS is the HRQL measure focusing on hot flash concerns. Conclusions: This paper provides an overall understanding on the currently available breast cancer-specific HRQL instruments in women breast cancer patients.

Development of a Web-Based Program for Cross-Calibration and Record Management of Radiation Measuring Equipment

  • Park, So Hyun;Lee, Rena;Kim, Kyubo;Ahn, Sohyun;Lim, Sangwook;Cho, Samju
    • 한국의학물리학회지:의학물리
    • /
    • 제30권2호
    • /
    • pp.59-63
    • /
    • 2019
  • Purpose: To manage radiation measurement equipment, a web-based management program has been developed in this study. Materials and Methods: This program is based on a web service and Java Server Pages (JSP) and employs compatibility and accessibility. Results: The first step in the workflow has been designed to create accounts for each user or organization and to log in. The program consists of two parts: fields for listed instruments, and measurement information. The instruments for measuring radiation listed in this program are as follows: ionization chambers, survey meters, thermometers, barometers, electrometers, and phantoms. Instrument properties can be put in the recording fields and browsing for associated instruments can be performed. The main part of the program is the cross-calibration for each ion chamber. For instance, the ionization chamber to be used as a relative dosimeter can be registered by cross-calibration data with a reference chamber calibrated by an accredited laboratory. This program supports methods using the central axis transfer theory for cross-calibration for the ionization chambers. The reference and field ionization chambers were placed in a solid water phantom along the beam central axis at two different depths, and then the positions were switched. Each measured value was used for calculating the cross-calibration factor. Conclusions: Because many instruments are used and managed in radiation oncology departments, systematic, traceable recording is very important. The web-based program developed in this study is expected to be used effectively in the maintenance of radiation measurement instruments.