• 제목/요약/키워드: instability of resistance

검색결과 114건 처리시간 0.024초

Co 및 Co/Ti 이중막에 의해 형성된 Co-실리사이드의 열적 불안정성 (Thermal instability of Co-silicides formed by Co and Co/Ti bilayer)

  • 장지근;엄우용;신철상;장호정
    • 전자공학회논문지A
    • /
    • 제33A권11호
    • /
    • pp.105-111
    • /
    • 1996
  • We have invetigated the characteristics of thermal instability of Co-silicides annealed at 850$^{\circ}$C ~ 1000$^{\circ}$C for 10~90 minutes in a furance with N$_{2}$ ambient. In our experiments, Co-silicides and Co/Ti bilayer silicides were formed by depositing (Co, Ti) films on the clean Si substrates in an E-beam evaporator and performing the RTA annelaing. The sheet resistances of Co-silicides formed form Co exhibited the nearly constant value under the post-annealing time above 900$^{\circ}$C showing the increase of 30% and 60% under the conditions annealed at 900$^{\circ}$C and 1000$^{\circ}$C for 30minutes. On the other hand, there were no remarkable changes in the sheet resistance sof Co-silicides formed form Co/Ti bilayer under the post-annealing conditons below 1000$^{\circ}$C.

  • PDF

SA 508C-3강의 고온에서 J-R Curve 및 Tmat의 평가 (Evaluation of J-R Curve and Tmat of SA 508C-3 Steel at Elevated Temperature)

  • 임만배;차귀준
    • 한국해양공학회지
    • /
    • 제12권3호통권29호
    • /
    • pp.60-67
    • /
    • 1998
  • In this study, the J-Resistance Curve and material tearing modulus of SA508-C3 steel, which is one of the used nuclear pressure vessel steel, are measured ar room temperature, $200^{circ}C$ and $300^{circ}C$ according to load ratio analysis and ASTM E813, ASTM E1152, respectively. It is observed that J-R curve and Tmat value decrease as the temperature level increase. Applicability of $T_j$ proposed by Paris et al as instability parameter for ductile material is investigated. It is concluded that results are the $T_j$ parameter may be used as a crack instability parameter.

  • PDF

Cr-Mo 강과 Cr 강의 J-R곡선의 측정 및 응용 (Measurement and Application of J-R Curves of Cr-Mo Steel and Cr Steel)

  • 안승균;허용학;박재학
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집A
    • /
    • pp.328-332
    • /
    • 2000
  • Following the method described in ASTM E1737, J resistance curves are measured for Cr-Mo steel SA387, and Cr steel A240 which are used as piping materials in nuclear industry. Crack driving force diagrams are generated in order to find out instability points in crack growth. The $J_{appl}$ curves, which are used in the crack driving force diagram, are obtained from EPRI J estimation method and the finite element analysis. Crack growth instability points are plotted in load-crack length plane and the results are discussed.

  • PDF

고정밀 백금저항온도계를 이용한 교정기관의 온도교정능력 수행평가 (Performance Assessment on Temperature Calibration Capability of the Calibration Laboratories Using High-Precision Platinum Resistance Thermometers)

  • 감기술;이영희;양인석
    • 센서학회지
    • /
    • 제22권6호
    • /
    • pp.415-420
    • /
    • 2013
  • Calibration capabilities for thermometer calibration by comparison method were assessed using high-precision industrial platinum resistance thermometers (IPRT). It was found in the performance assessment that out of 31 laboratories who participated, 28 laboratories resulted magnitude of En number less than 1 at every calibration points they submitted results in the range from 50 to $500^{\circ}C$. The results of about 75% of the laboratories showed the difference from the assigned values less than 1/10 of the tolerance level of the class B IPRT. This indicates that the participating calibration laboratories performed with satisfactory level that was enough to calibrate IPRTs to significant precision. The sensors used in this work were manufactured and chosen by the criteria of long-term instability less than 4 mK and hysteresis less than 8 mK in the temperature range used in this work. Furthermore, the change in the resistance of the sensors in the calibration temperature range were less than the uncertainty of the calibration, 25 mK (k=2).

열원 냉각용 루프 써모사이폰의 작동 특성 (Performance Characteristics of a Loop Thermosyphon for Heat Source Cooling)

  • 최두성;송태호
    • 대한기계학회논문집B
    • /
    • 제28권12호
    • /
    • pp.1475-1483
    • /
    • 2004
  • Loop thermosyphon(LTS) has many good characteristics such as low thermal resistance, no power consumption, noiseless operation and small size. To investigate the overall performance of LTS, we have performed various experiments varying three parameters: input power of the heater, working fluid(water, ethanol, FC3283) and filling ratio of the working fluid. At a combination of these parameters, temperature measurements are made at many locations of the LTS. The temperature difference between the evaporator and the condenser is used to obtain the thermal resistance. In addition, flow visualization using a high speed camera is carried out. The thermal resistance is not constant. It is lower at higher input power, which is one of the distinct merits of LTS. Flow instabilities are frequently observed when changing the working fluid, the input power and the filling ratio. The results show that the LTS can be readily put into practical use. Future practical application in electronic cooling is recommended.

Control Strategy of Smoothing Arc for DC Arc Furnace

  • Jung, Kyungsub;Suh, Yongsug;Lee, Yongjoong;Kim, Taewon;Park, Taejun
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 전력전자학술대회 논문집
    • /
    • pp.354-355
    • /
    • 2013
  • Fundamental features of the arc stability in DC arc furnace of 720V/100kA/72MW have been investigated. Cassie-Mayr arc model has been employed and applied for the target dc arc furnace. In order to characterize the parameters of Cassie-Mayr arc model and the behavior of unstable arc dynamics, the advanced arc simulations of magneto-hydrodynamics (MHD) has been performed. The MHD based arc simulation has been validated in the subcomponent level, for the free burning arc set up in the laboratory. From the results of MHD simulation, dc arc dynamic resistance is proposed to be an effective arc stability function reflecting the instability of dynamic arc behavior. The experimental result confirms the usefulness of proposed dynamic arc resistance as arc stability function. The proposed arc stability function can be regarded as an effective criterion for the overall power conversion system to maintain highly stable arcing operation leading to better productivity and reliability.

  • PDF

Control Algorithm of Thyristor Rectifier to Improve Arc Stability in DC Arc Furnace

  • Jung, Kyungsub;Suh, Yongsug;Kim, Taewon;Park, Taejun
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 전력전자학술대회 논문집
    • /
    • pp.371-372
    • /
    • 2012
  • In this paper fundamental features of the arc stability in DC arc furnace of 720V/100kA/72MW have been investigated. Cassie-Mayr arc model has been employed for the target dc arc furnace. In order to characterize the parameters of Cassie-Mayr arc model and the behavior of unstable arc dynamics, the advanced arc simulations of magneto-hydrodynamics (MHD) has been performed. Based on the results of MHD simulation, dc arc dynamic resistance is proposed to be an effective arc stability function reflecting the instability of dynamic arc behavior. The experimental result confirms the usefulness of proposed dynamic arc resistance as arc stability function. The proposed arc stability function can be regarded as an effective criterion for the overall power conversion system to maintain highly stable arcing operation leading to better productivity and reliability.

  • PDF

Dichlofluanid 저항성 잿빛곰팡이병균(Botrytis cinerea)의 저항성 불안정 및 감수성균과의 경합 능력 비교 (Instability of Dichlofluanid Resistance in Dichlofluanid-Resistant Botrytis cinerea Isolates and Comparison of Their Competitive Ability with Dichlofluanid-Sensitive Isolates)

  • 김병섭;박은우;임태헌;조광연
    • 한국식물병리학회지
    • /
    • 제12권4호
    • /
    • pp.415-421
    • /
    • 1996
  • 대전, 공주, 논산, 부여와 김해 등에서 병든 딸기, 토마토, 오이에서 총 992균주의 잿빛곰팡이병균을 분리하여 이들 균주로부터 dichlofluanid 저항성 5균주, 감수성 5균주를 임의로 선발하였다. 분리된 균의 dichlofluanid 저항성을 조사한 결과 105균주(10.6%)가 저항성이었다. 저항성균 균사의 최소 억제 농도(minimum inhibitory concentration)는 100~500$\mu\textrm{g}$/ml 이상이었으나 감수성균은 10 $\mu\textrm{g}$/ml 미만이었다. Dichlofluanid 저항성의 안정성 조사를 위하여 35$^{\circ}C$고온 처리 및 계대 배양할 때 조사된 저항성 5균주 중 3균주는 저항성이 감소하거나 상실되었다. 저온 저장 및 온실에 장기 보관할 때는 조사된 저항성 균주 모두가 저항성이 감소하거나 완전히 상실되는 것으로 나타났다. 이러한 결과는 이 약제에 대한 저항성이 불안정하다는 것을 나타낸다. 오이에 감수성균 및 저항성균을 혼합 접종한 후 재분리할 때 시간이 지날수록 감수성균이 더 많이 분리되어 저항성균의 경합 능력이 감수성 균주에 비하여 열등하였다.

  • PDF

전신-폐 단락술 후 산소포화도의 불안정성의 위험인자 분석 (Risk Factor Analysis for $SaO_2$ Instability after Systemic-pulmonary Shunt)

  • 정성호;윤석원;박정준;서동만;김영휘;고재곤;박인숙;윤태진
    • Journal of Chest Surgery
    • /
    • 제38권4호
    • /
    • pp.277-283
    • /
    • 2005
  • 다양한 선천성 심기형에서 전신-폐 단락술을 시행하는 경우 단락의 기술적 실패에 의한 폐색이 없이 수술 후 산소포화도가 불안정한 경우가 있다. 이에 전신-폐 단락술 후 산소포화도 불안정성의 빈도 및 위험 인자를 분석하고 그 원인 기전에 대해 고찰하였다. 대상 및 방법: 1996년 1월부터 2000년 12월까지 전신-폐 단락술을 받은 환자 중 폐동맥의 적절한 성장으로 단심실 혹은 양심실 교정을 받았거나 받을 예정인 93명의 환자를 연구 대상으로 하였다. 환자들의 연령, 수술 당시 체중, 수술 전혈색소치는 각각 3일-36세(중간 값: 1.8개월), 2.3-51kg (중간 값: 4.1kg), $10.7\~24.3$ gm/dL (중간 값: 15.2 gm/dL)이었다. 진단은 폐동맥 폐쇄나 협착을 동반한 기능적 단심실(39예), 활로씨 4징증(38예), 심실중격결손이 없는 폐동맥 폐쇄(16예)의 순이었고, 폐혈류 공급원은 동맥관이나 기존 단락(64예) 및 협착성 우심실 유출로를 통한 전방 혈류(29)였다. 수술 후 단락의 기술적 실패나 호흡 보조의 문제점이 없이 산소포화도가 1시간 이상 $50\%$ 미만으로 유지되었던 경우 산소 포화도 불안정성으로 정의하였다. 결과: 수술 후 10명$(10.7\%)$의 환자에서 산소포화도의 불안정성을 보였으며, 심초음파로 단락의 폐색 가능성을 배제한 뒤 폐혈관 저항을 감소시키는 치료를 통해 모두 수 시간 내에 산소포화도를 회복시킬 수 있었다. 산소포화도의 불안정성의 위험 인자로는 수술 시 연령의 증가(p=0.039),수술 전 낮은 산소 포화도(p=0.001) 및 응급 수술(p=0.0001) 등이었고, 협착성 우심실 유출로를 통한 전방 혈류에 의한 폐혈류 공급은 약간의 유의성을 나타내었다(p=0.065). 걸론: 단락이 필요한 선천성 심기형 환자가 수술 전 저산소증이 심하고 혈역학이 불안정한 경우 수술 후 폐혈관 저항의 일시적 상승에 의해 산소포화도의 불안정성이 나타날 수 있으며, 이 경우 폐혈관 저항을 감소시키는 치료를 통하여 산소포화도를 안정시킬 수 있다.

폴리실리콘 기판 위에 형성된 코발트 니켈 복합실리사이드 박막의 열처리 온도에 따른 물성과 미세구조변화 (Characteristics and Microstructure of Co/Ni Composite Silicides on Polysilicon Substrates with Annealing Temperature)

  • 김상엽;송오성
    • 한국재료학회지
    • /
    • 제16권9호
    • /
    • pp.564-570
    • /
    • 2006
  • Silicides have been required to be below 40 nm-thick and to have low contact resistance without agglomeration at high silicidation temperature. We fabricated composite silicide layers on the wafers from Ni(20 nm)/Co(20 nm)/poly-Si(70 nm) structure by rapid thermal annealing of $700{\sim}1100^{\circ}C$ for 40 seconds. The sheet resistance, surface composition, cross-sectional microstructure, and surface roughness were investigated by a four point probe, a X-ray diffractometer, an Auger electron spectroscopy, a field emission scanning electron microscope, and a scanning probe microscope, respectively. The sheet resistance increased abruptly while thickness decreased as silicidation temperature increased. We propose that the fast metal diffusion along the silicon grain boundary lead to the poly silicon mixing and inversion. Our results imply that we may consider the serious thermal instability in designing and process for the sub-0.1 um CMOS devices.