• Title/Summary/Keyword: insertion

Search Result 4,218, Processing Time 0.034 seconds

Clinical Analysis of Spontaneous Pneumothorax (자연기흉의 임상적 고찰)

  • Son, Ji-Woong;Park, Jae-Yong;Kim, Kwan-Young;Chae, Sang-Chul;Kang, Tae-Kyong;Park, Ki-Su;Kim, Chang-Ho;Jung, Tae-Hoon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.3
    • /
    • pp.374-382
    • /
    • 1999
  • Background: The aim of this study was to investigate etiologic factor, treatment, prognosis of spontaneous pneumothorax (SP). Material and Methods: The medical records of 225 cases of SP experienced at Kyungpook University Hospital from Jan. 1996 to Dec. 1997 were retrospectively analyzed. Results: The patients were 128 primary SP and 97 secondary SP. The mean age was $30{\pm}15.5$ years in primary SP and $51{\pm}7.4$ years in secondary SP. The ratio of male to female was 8:1 in primary SP and 5.5:1 in secondary SP. Smoker was more common in seconday SP (71.1 %) than primary SP (34.4%). About 70% of patients with primary and secondary SP was underweighted. The previous history of SP was present in 28.9% and 25.8% of primary and secondary SP, respectively. The main underlying lung diseases in secondary SP were inactive tuberculosis (68%), active tuberculosis (12.4%) and COPD (11.3%). Tube thoracostomy was performed in 96.8% and 97.9% of primary and secondary SP, respectively. The duration of chest tube insertion was longer in seconday SP ($18.2{\pm}19.59$ days) than primary SP ($7.5{\pm}6.57$ days). The open thoracotomy were performed in 22.7% and 10.3% of primary and secondary SP, respectively. The most com- mon indication of open thoracotomy was recurrence in primary SP and persistent air leak in secondary SP. During following-up of $17{\pm}7.8$ months, the recurrence rate in patients with conservative treatment was 16.5% and 11.8% of primary and secondary SP, respectively. The recurrence was most common within 1 month after discharge. Conclusion: Greater attention and research about SP are necessary for more efficient patient care.

  • PDF

The Effect of Yunkyopaedocksangamibang on Allergic Contact Dermatitis : Based on the mitigation of skin damage and distributive change of mast cell on DNCB re-expasure region of Mice (연교패독산가미방(連翹敗毒散可味方)이 알러지성 접촉피부염에 미치는 영향(影響) - DNCB 재노출부위의 생쥐 피부손상완화와 비만세포 분포 변화를 중심으로 -)

  • Kwon, Oh-Sung;Kim, Jin-Tack;Park, In-Sick;Ahn, Sang-Hyun;Lee, Hai-Poong;Kim, Ho-Hyun;Gang, Yun-Ho
    • The Journal of Dong Guk Oriental Medicine
    • /
    • v.8 no.1
    • /
    • pp.77-91
    • /
    • 1999
  • After allergic contact dermatitis elicitated by Dinitrochlorobenzene(DNCB) treatment, ICR female mice administered Yunkyopaedocksangamibang(YPGM) extract were observed to investigate the effect of YPGM on allergic contact dermatitis. This study investigated that contact hypersensitivity assay, abdominal skin morphologic changes including mast cells. At contact hypersensitivity assay, the right ear swelling in YPGM group were probability decreased than DNCB group. At observation of abdominal skin morphologic change, the infiltration of lymphocyte, lymphocyte insertion to epithelium, enlarged capillary, angiogenesis, and damages of epithelium as cytoplasmic vacuolation and enlarge of inter cellular space in YPGM were diminished than DNCB group. The number of mast cell was increased both DNCB and YPGM group. The shape of mast cell in DNCB group was mainly appeared degranulated type, but granulated type in YPGM group. The number of serotonin positive cell was increased both DNCB and YPGM group. The shape of serotonin positive cell in DNCB group was mainly appeared degranulated type, but granulated type in YPGM group. As results indicated that the YPGM extract administration work on the mitigation of skin damages in mouse with allergic contact dermatitis.

  • PDF

A Study on Electron Dose Distribution of Cones for Intraoperative Radiation Therapy (수술중 전자선치료에 있어서 선량분포에 관한 연구)

  • Kang, Wee-Saing;Ha, Sung-Whan;Yun, Hyong-Geun
    • Progress in Medical Physics
    • /
    • v.3 no.2
    • /
    • pp.1-12
    • /
    • 1992
  • For intraoperative radiation therapy using electron beams, a cone system to deliver a large dose to the tumor during surgical operation and to save the surrounding normal tissue should be developed and dosimetry for the cone system is necessary to find proper X-ray collimator setting as well as to get useful data for clinical use. We developed a docking type of a cone system consisting of two parts made of aluminum: holder and cone. The cones which range from 4cm to 9cm with 1cm step at 100cm SSD of photon beam are 28cm long circular tubular cylinders. The system has two 26cm long holders: one for the cones larger than or equal to 7cm diamter and another for the smaller ones than 7cm. On the side of the holder is an aperture for insertion of a lamp and mirror to observe treatment field. Depth dose curve. dose profile and output factor at dept of dose maximum. and dose distribution in water for each cone size were measured with a p-type silicone detector controlled by a linear scanner for several extra opening of X-ray collimators. For a combination of electron energy and cone size, the opening of the X-ray collimator was caused to the surface dose, depths of dose maximum and 80%, dose profile and output factor. The variation of the output factor was the most remarkable. The output factors of 9MeV electron, as an example, range from 0.637 to 1.549. The opening of X-ray collimators would cause the quantity of scattered electrons coming to the IORT cone system. which in turn would change the dose distribution as well as the output factor. Dosimetry for an IORT cone system is inevitable to minimize uncertainty in the clinical use.

  • PDF

The effects of pregnancy on alveolar bone turnover during experimental tooth movement in rats (백서에서 실험적 치아이동시 임신이 치조골 교체(Turnover)에 미치는 영향에 대한 연구)

  • Kim, Young-Sun;Lee, Ki-Soo
    • The korean journal of orthodontics
    • /
    • v.30 no.4 s.81
    • /
    • pp.413-421
    • /
    • 2000
  • The purpose of this study was to observe the effects of pregnancy on the experimental tooth movement and alveolar bone turnover process of Sprague-Dawley female rat. Sixty rats were divided into pregnant-tooth movement group(P-Tm), normal-tooth movement group(N-Tm) and normal group(N). Maxillary first molar appliances were inserted bilaterally and activated to 40grams. To measure the amount of tooth movement, x-ray was taken 2 times after appliance insertion and before sacrifice. Animals were sacrificed at 1,3,7,14 days(N=5). Just after sacrifice, alveolar bones were collected and frozen immediately for biochemical analysis. Tooth movement was assessed cephalometrically and tartrate-resistant acid(TRAP) and alkaline phosphatase (ALP) activities were measured in extracts of paradental alveolar bone. The results were as follows: 1. The amount of tooth movement in P-Tm group was greater than that of N-Tm group(p<0.01). 2. Alveolar bone ALP of normal tooth movement group was not significantly different from the control, TRAP was significantly different from the control(p<0.01). In normal tooth movement group, alveolar bone ALP was increased gradually and peak(day 7) fell off significantly at day 14(p<0.05). The Peak of alveolar bone TRAP(day 7) fell off slightly, sustained day 14(p<0.01). 3. Alveolar bone ALP and TRAP of pregnant tooth movement group were not significantly different from that of normal tooth movement group. In pregnant tooth movement group, alveolar bone ALP was increased at day 3(p<0.01) and fell off significantly at day 7-14, alveolar bone TRAP were increased at day 3 and sustained day 14. 4. The peak of alveolar bone phosphatases in pregnant tooth movement group(day3) preceded the peak in normal tooth movement group(day7) (p<0.01). According to the above results, we suggested that bone resorption activity was increased in alveolar bone of pregnant rat, and the degree of tooth movement in pregnancy may be greater than that of normal group because of high bone turnover of alveolar bone in pregnant rat.

  • PDF

Synthesis and Electrochemical Properties of Carbon Coated Li4Ti5O12 using PVC (PVC를 원료로 탄소코팅한 Li4Ti5O12의 합성 및 전기화학적 특성)

  • Hyun, Si-Cheol;Na, Byung-Ki
    • Clean Technology
    • /
    • v.24 no.1
    • /
    • pp.77-84
    • /
    • 2018
  • In this study, $Li_4Ti_5O_{12}$ anode materials for lithium ion battery were synthesized by dry ball-mill method. Polyvinyl chloride (PVC) as a carbon source was added to improve electrochemical properties. When the PVC was added after $Li_4Ti_5O_{12}$ formation, the spinel structure was well synthesized and it was confirmed by X-ray diffraction (XRD) experiments. When the carbon material was added before the synthesis and the heat treatment was performed, it was confirmed that a material having a different crystal structure was synthesized even when a small amount of carbon material was added. In the case of $Li_4Ti_5O_{12}$ without the carbon material, the electrical conductivity value was about $10{\mu}S\;m^{-1}$, which was very small and similar to that of the nonconductor. As the carbon was added, the electrical conductivity was greatly improved and increased up to 10,000 times. Electrochemical impedance spectroscopy (EIS) analysis showed that the size of semicircle corresponding to the resistance decreased with the carbon addition. This indicates that the resistance inside the electrode is reduced. According to the Cyclic voltammetry (CV) analysis, the potential difference between the oxidation peak and the reduction peak was reduced with carbon addition. This means that the rate of lithium ion insertion and deinsertion was increased. $Li_4Ti_5O_{12}$ with 9.5 wt% PVC added sample showed the best properties in rate capabilities of $180mA\;h\;g^{-1}$ at 0.2 C-rate, $165mA\;h\;g^{-1}$ at 0.5 C-rate, and $95.8mA\;h\;g^{-1}$ at 5 C-rate.

Clinical Characteristics of Aspergilloma (국균종의 임상적 고찰)

  • Kim, Ki-Up;Gil, Hyo-Wook;Lee, Suk-Ho;Kim, Do-Jin;Na, Moon-Jun;Uh, Soo-Taek;Kim, Yong-Hoon;Park, Choon-Sik
    • Tuberculosis and Respiratory Diseases
    • /
    • v.52 no.1
    • /
    • pp.46-53
    • /
    • 2002
  • Background: Pulmonary aspergilloma is relatively common in korea. It arises from the colonization and proliferation of Aspergillus in preexisting lung parenchymal cavities, in particular tuberculosis. The most common symptom in this disorder is hemoptysis, which mayor may not be massive and life threatening. A routine chest radiography and computed tomography (CT) are the most important diagnostic procedures. A surgical resection of the aspergilloma has recently been recommended, because of the relatively low incidence of postoperative complications than in the past. A more concentrated sample of patients with aspergilloma, who either underwent a thoracotomy or tested positive for aspergillus antibodies, were reviewed. Method : The medical records of twenty-two patients with aspergilloma, who had a proven thoracotomy (9 cases), or who tested positive for the diagnostic procedure and/or aspergillus antibodies (13 cases) from January 1995 to December 2000, were reviewed retrospectively. Results : The most common underlying lung disease was a current or old healed tuberculosis, and 3 patients had cultures of mycobacterium other than tuberculosis (MOTT). The mean time until the aspergilloma was detected 5.91 years in the healed tuberculosis cases. The others cases involved a lung abscess, bronchiectasis and without lung disease. The extrapulmonary disease was alcoholism and diabetes. Hemoptysis was most common in 72.7%. A computed tomography (CT) is useful for diagnosis. The right upper lobe, especially the posterior segment, is the most common location. Bronchial artery embolization is ineffective for a long term follow-up. A lobectomy is most common in a thoracotomy, and intra-operative and post-operative complications are rare. During follow-up, the mortality rate, not from the aspergilloma but from respiratory failure, was 13.6%. Conclusion : Aspergilloma is a common cavitary lung disease, It mainly arises from tuberculosis, either current or healed, but extra-pulmonary disease including alcoholism or diabetes are other possible risk factors. Their most common problem in aspergilloma is hemoptysis. Surgery has a low risk of post-operative complications and is recommended in relatively preserved lung function or healthy patients. Medical maneuvers including embolization, and the local insertion of certain materials needs to be studied more closely.

Detection of Pyrazinamide Resistance in Mycobacterium Tuberculosis by Sequencing of pncA Gene (pncA 유전자의 염기 서열 결정에 의한 결핵균의 Pyrazinamide 내성 진단)

  • Hwang, Jee-Yoon;Kwak, Kyung-Rok;Park, Hye-Kyung;Lee, Ji-Seok;Park, Sam-Seok;Kim, Yun-Seong;Lee, Jung-Yoo;Chang, Chul-Hun;Lee, Min-Ki;Park, Soon-Kew
    • Tuberculosis and Respiratory Diseases
    • /
    • v.50 no.1
    • /
    • pp.94-105
    • /
    • 2001
  • Background : Examining the biological susceptibility of Mycobacterium tuberculosis to pyrazinamide (PZA) in vitro is very difficult as PZA is inactive under normal culture conditions. The biological susceptibility test, an enzyme assay for Pzase activity, and a genetic test for pncA gene mutations, were performed in order to predict PZA resistance. Methods : 28 cultured clinical isolates of Mycobacterium tuberculosis were tested. The biological susceptibility was performed by the absolute concentration method using Lowenstein-Jensen media. The PZase activity was tested by means of Wayne's method. A 710-bp region includes the entire open reading frame of pncA was amplified and sequenced. Results : All six strains with positive PZase activity exhibited no pncA mutations with one strain showing a false resistance in the biological susceptibility test. Among the 22 strains with no PZase activity, 21 exhibited showed pncA mutations. In the biological susceptibility test, 20 strains were resistant, and one was susceptible, and the other flied to test. The mutation types varied with ten missense, one silent and one nonsense mutation 1 slipped-strand mispairing, and 6 frameshift mutations. Three strains had an adenine to guanine mutation at position -11 upstream of the start codon. Conclusion : The mutation at the pncA promotor region is frequent at -11 upstream position. Automatic sequencing of pncA is a useful tool for rapid and accurate detection of PZA resistant M. tuberculosis, and for demonstrating the epidemiological relatedness of the PZA resistant M. tuberculosis strains.

  • PDF

Biological stability of Zirconia/Alumina composite ceramic Implant abutment (지르코니아/알루미나 복합 지대주의 생물학적 안정성에 관한 연구)

  • Bae, Kyu-Hyun;Han, Jung-Suk.;Kim, Tae-Il;Seol, Yang-Jo;Lee, Yong-Moo;Ku, Young;Cho, Ki-Young;Chung, Chong-Pyoung;Han, Soo-Boo;Rhyu, In-Chul
    • Journal of Periodontal and Implant Science
    • /
    • v.36 no.2
    • /
    • pp.555-565
    • /
    • 2006
  • The purpose of the present study is to evaluate the biological stability of the zirconia/alumina composite abutment by histologic and radiographic examination in clinical cases. 17 partially edentulous patients (5 men and 12 women, mean age 47) were treated with 37 implants. The implants were placed following the standard two-stage protocol. After a healing period of 3 to 6 months, zirconia/alumina composite abutments were connected. All radiographs were taken using paralleling technique with individually fabricated impression bite block, following insertion of the prosthesis and at the 3-, 6-, 12 month re-examinations. After processing the obtained images, the osseous level was calculated using the digital image in the mesial and distal aspect in each implant. An ANOVA and t-test were used to test for difference between the baseline and 3-, 6-, 12 months re-examinations, and for difference between maxilla and mandible. Differences at P <0.05 were considered statistically significant. For histologic examination, sample was obtained from the palatal gingiva which implant functioned for 12 months. Sections were examined under a light microscope under various magnifications. Clinically, no abutment fracture or crack as well as periimplantitis was observed during the period of study. The mean bone level reduction(${\pm}standard$ deviation) was 0.34 rom(${\pm}\;0.26$) at 3-months, 0.4 2mm(${\pm}\;0.30$) at 6-months, 0.62 mm(${\pm}\;0.28$) at 12-months respectively. No statistically significant difference was found between baseline and 3-, 6-, 12-months re-examinations (p > 0.05). The mean bone level reduction in maxilla was 0.33(${\pm}0.25$) at 3-months, 0.36(${\pm}0.33$) at 6-months, 0.56(${\pm}0.26$) at 12-months. And the mean bone level reduction in mandible was 0.35(${\pm}0.27$) at 3-months, 0,49(${\pm}0.27$) at 6-months, 0.68(${\pm}0.30$) at 12-months. No statistical difference in bone level reduction between implants placed in the maxilla and mandible. Histologically, the height of the junctional epithelium was about 2.09 mm. And the width was about 0.51 mm. Scattered fibroblasts and inflammatory cells, and dense collagen network with few vascular structures characterized the portion of connective tissue. The inflammatory cell infiltration was observed just beneath the apical end of junctional epithelium and the area of direct in contact with zirconia/alumina abutment. These results suggest the zirconia/alumina composite abutment can be used in variable intraoral condition, in posterior segment as well as anterior segment without adverse effects.

A STUDY ON THE MEASUREMENT OF THE IMPLANT STABILITY USING RESONANCE FREQUENCY ANALYSIS (공진 주파수 분석법에 의한 임플랜트의 안정성 측정에 관한 연구)

  • Park Cheol;Lim Ju-Hwan;Cho In-Ho;Lim Heon-Song
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.2
    • /
    • pp.182-206
    • /
    • 2003
  • Statement of problem : Successful osseointegration of endosseous threaded implants is dependent on many factors. These may include the surface characteristics and gross geometry of implants, the quality and quantity of bone where implants are placed, and the magnitude and direction of stress in functional occlusion. Therefore clinical quantitative measurement of primary stability at placement and functional state of implant may play a role in prediction of possible clinical symptoms and the renovation of implant geometry, types and surface characteristic according to each patients conditions. Ultimately, it may increase success rate of implants. Purpose : Many available non-invasive techniques used for the clinical measurement of implant stability and osseointegration include percussion, radiography, the $Periotest^{(R)}$, Dental Fine $Tester^{(R)}$ and so on. There is, however, relatively little research undertaken to standardize quantitative measurement of stability of implant and osseointegration due to the various clinical applications performed by each individual operator. Therefore, in order to develop non-invasive experimental method to measure stability of implant quantitatively, the resonance frequency analyzer to measure the natural frequency of specific substance was developed in the procedure of this study. Material & method : To test the stability of the resonance frequency analyzer developed in this study, following methods and materials were used : 1) In-vitro study: the implant was placed in both epoxy resin of which physical properties are similar to the bone stiffness of human and fresh cow rib bone specimen. Then the resonance frequency values of them were measured and analyzed. In an attempt to test the reliability of the data gathered with the resonance frequency analyzer, comparative analysis with the data from the Periotest was conducted. 2) In-vivo study: the implants were inserted into the tibiae of 10 New Zealand rabbits and the resonance frequency value of them with connected abutments at healing time are measured immediately after insertion and gauged every 4 weeks for 16 weeks. Results : Results from these studies were such as follows : The same length implants placed in Hot Melt showed the repetitive resonance frequency values. As the length of abutment increased, the resonance frequency value changed significantly (p<0.01). As the thickness of transducer increased in order of 0.5, 1.0 and 2.0 mm, the resonance frequency value significantly increased (p<0.05). The implants placed in PL-2 and epoxy resin with different exposure degree resulted in the increase of resonance frequency value as the exposure degree of implants and the length of abutment decreased. In comparative experiment based on physical properties, as the thickness of transducer increased, the resonance frequency value increased significantly(p<0.01). As the stiffness of substances where implants were placed increased, and the effective length of implants decreased, the resonance frequencies value increased significantly (p<0.05). In the experiment with cow rib bone specimen, the increase of the length of abutment resulted in significant difference between the results from resonance frequency analyzer and the $Periotest^{(R)}$. There was no difference with significant meaning in the comparison based on the direction of measurement between the resonance frequency value and the $Periotest^{(R)}$ value (p<0.05). In-vivo experiment resulted in repetitive patternes of resonance frequency. As the time elapsed, the resonance frequency value increased significantly with the exception of 4th and 8th week (p<0.05). Conclusion : The development of resonance frequency analyzer is an attempt to standardize the quantitative measurement of stability of implant and osseointegration and compensate for the reliability of data from other non-invasive measuring devices It is considered that further research is needed to improve the efficiency of clinical application of resonance frequency analyzer. In addition, further investigation is warranted on the standardized quantitative analysis of the stability of implant.

Polymorphisms and Allele Distribution of Novel Indel Markers in Jeju Black Cattle, Hanwoo and Imported Cattle Breeds (제주흑우, 한우 및 수입 소 품종에서 새로운 indel 마커의 다형성과 대립인자 분포)

  • Han, Sang-Hyun;Kim, Jae-Hwan;Cho, In-Cheol;Cho, Sang-Rae;Cho, Won-Mo;Kim, Sang-Geum;Kim, Yoo-Kyung;Kang, Yong-Jun;Park, Yong-Sang;Kim, Young-Hoon;Park, Se-Phil;Kim, Eun-Young;Lee, Sung-Soo;Ko, Moon-Suck
    • Journal of Life Science
    • /
    • v.22 no.12
    • /
    • pp.1644-1650
    • /
    • 2012
  • The aim of this study was to screen the polymorphisms and distribution of each genotype of insertion/ deletion (indel) markers which were found in a preliminary comparative study of bovine genomic sequence databases. Comparative bioinformatic analyses were first performed between the nucleotide sequences of Bovine Genome Project and those of expressed sequence tag (EST) database, and a total of fifty-one species of indel markers were screened. Of these, forty-two indel markers were evaluated, and nine informative indel markers were ultimately selected for population analysis. Nucleotide sequences of each marker were re-sequenced and their polymorphic patterns were typed in six cattle breeds: Holstein, Angus, Charolais, Hereford, and two Korean native cattle breeds (Hanwoo and Jeju Black cattle). Cattle breeds tested in this study showed polymorphic patterns in eight indel markers but not in the Indel-15 marker in Charolais and Holstein. The results of analysis for Jeju Black cattle (JBC) population indicated an observed heterozygosity (Ho) that was highest in HW_G1 (0.600) and the lowest in Indel_29 (0.274). The PIC value was the highest in HW_G4 (0.373) and lowest in Indel_6 (0.305). These polymorphic indel markers will be useful in supplying genetic information for parentage tests and traceability and to develop a molecular breeding system for improvement of animal production in cattle breeds as well as in the JBC population.