• Title/Summary/Keyword: input-output

Search Result 8,740, Processing Time 0.028 seconds

Study of D2 cell simulation by using WRspice (WRspice를 이용한 D2 cell의 simulation 연구)

  • 남두우;강준희
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.02a
    • /
    • pp.92-94
    • /
    • 2003
  • In superconductive digital logic circuits, D2 cells can be used to compose a decoder an important component of an Arithmetic Logic Unit (ALU). In this wor, we simulated D2 cell by using WRspice. D2 cell has one input, one switch input, and two outputs (output1 and output2). D2 cell functions in such way that output1 follows the input and output2 is the complement of the input data, when the switch input is "0, ". However, when there is a switch input "1, " the opposite output signals are generated. In this paper, we optimized a D2 cell by using WRspice, and obtained the minimum margin of 26%. Our optimized D2 cell will play a key role in the ALU fabrication.the ALU fabrication.

  • PDF

RSFQ DFFC Circuit Design for Usage in developing ALU (ALU의 개발을 위한 RSFQ DFFC 회로의 설계)

  • 남두우;김규태;강준희
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.123-126
    • /
    • 2003
  • RSFQ (Rapid Single Flux Quantum) circuits are used in many practical applications. RSFQ DFFC (Delay Flip-Flop with complementary outputs) circuits can be used in a RAM, an ALU (Arithmetic Logic Unit), a microprocessor, and many communication devices. A DFFC circuit has one input, one switch input, and two outputs (output l and output 2). DFFC circuit functions in such way that output 1 follows the input and output 2 is the complement of the input when the switch input is "0." However, when there is a switch input "1."the opposite output signals are generated. In this work, we have designed an RSFQ DFFC circuit based on 1 ㎄/$\textrm{cm}^2$ niobium trilayer technology. As circuit design tools, we used Xic, WRspice, and Lmeter After circuit optimization, we could obtain the bias current margins of the DFFC circuit to be above 32%.

  • PDF

지하수 오염저감기술 연구사업의 성과 체계화를 위한 Input-Output-Outcome Roadmap의 작성

  • 안은영;김성용;이재욱;손병국
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.04a
    • /
    • pp.421-425
    • /
    • 2004
  • 연구개발의 성과를 체계적으로 가시화하는 데는 많은 어려움이 존재한다. 이러한 적용상의 문제점은 연구개발의 input, output, outcome의 개념을 도입하여 Input-Output-Outcome Roadmap 작성으로 해소될 수 있다. 본 연구에서는 지하수 오염저감기술 연구사업에 대한 적용을 통하여 사업의 경쟁력 및 사업성을 확보를 위한 연구개발 성과의 체계적 지표를 제시하였다.

  • PDF

A Study on the Step-up PWM Cycloconverter (승압형 PWM 싸이크로 콘버터에 관한 연구)

  • 박민호;홍순찬;김기택
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.38 no.6
    • /
    • pp.431-440
    • /
    • 1989
  • This paper proposes a new PWM cycloconverter which can step up input voltage. With input reactors ac power supply acts as current source, and with output capacitors the balanced output voltage is build-up. The converter is modeled with fourth order state equation using dq transformation and the steady state characteristics are evaluated. It is shown that the proposed converter can generate the output voltage 2-5 times greater than input voltage. The output voltage and input current have sinusoidal and smooth waveforms and the converter is capable of voltage build-up. The characteristics of the proposed converter is verified simulation and experiment.

  • PDF

A Study on Estimation of Distribution Rate of R&8 Input on R&D Output (R&D성과에 대한 R&D투입요소의 분배율 계측에 관한 연구)

  • Lee, Jae-Ha;Chang, Kyung
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.20 no.44
    • /
    • pp.129-134
    • /
    • 1997
  • The purpose of this study is to estimate the distribution rate of R&D input on R&D output in major manufacturing industrial sector. The distribution rate is estimated on time-series data for the period 1980 to 1996. The data used in this study can be divided into the two categories. 1) R&D output data (Patent, Utility) 2) R&D input data (R&D expenditure, R&D workers) The raw data of R&D expenditure is transformed into R&D stock. And the specific production function is used to represent the interaction between R&D input and output. The production function shows the maximum rate of R&D output that can be achieved by certain given, technologically possible, R&D input combinations. The main findings can be summarized as follows. 1) There was a diminishing return between R&D input and output$(\alpha+\beta<1). 2) R&D output growth was more affected by R&D expenditures than R&D workers. 3) R&D workers were more contributed highly to Patent granted than Utility model.

  • PDF

Control of Input Series Output Parallel Connected DC-DC Converters

  • Natarajan, Sirukarumbur Pandurangan;Anandhi, Thangavel Saroja
    • Journal of Power Electronics
    • /
    • v.7 no.3
    • /
    • pp.265-270
    • /
    • 2007
  • Equal rating DC-DC converter modules can be connected in series at the input for circuits requiring higher input voltages and in parallel at the output for circuits requiring higher output currents. Since the converter modules may not be practically identical, closed loop control has to ensure that each module equally shares the total input voltage and the load current. A control scheme consisting of a common output voltage loop, individual inner current loops and individual input voltage loops have been designed in this work to achieve input voltage and load current sharing as well as load voltage regulation under supply and load disturbances. The output voltage loop provides the basic reference for the inner current loops, which are also modified by the respective input voltage loops. The average of the converter input voltages, which is dynamically varying, is chosen as the reference for input voltage loops. This choice of reference eliminates interaction among different control loops. Type II compensators and Fuzzy Logic Controllers (FLCs) are designed and compared through MATLAB based simulation and FLC is found to be satisfactory. Hence TMS320F2407A DSP based FLC is implemented and the results are presented which prove the superiority of the FLC developed for this research.

Output Voltage Control of Z-Source Inverter by the Detection of the Input DC Voltage and Z-Network Capacitor Voltage (입력 직류 전압과 Z-네트워크 커패시터 전압 검출에 의한 Z-소스 인버터의 출력 전압 제어)

  • Kim, Se-Jin;Jung, Young-Gook;Lim, Young-Cheol;Choi, Joon-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.8
    • /
    • pp.1515-1522
    • /
    • 2011
  • This paper proposes the algorithm for the output AC voltage control of Z-source inverter by the detection of the input DC voltage and Z-network capacitor voltage. The actual modulation index of the proposed method is detected by the capacitor voltage in Z-network and input DC voltage of three-phase Z-source inverter. Control modulation index for the output voltage control is calculated by the detected actual modulation index and reference modulation index. And, calculated control modulation index is applied to the modified space vector modulation (SVM) for control the output voltage of Z-source inverter. To verify the validity of the proposed method, PSIM simulation was achieved and a DSP controlled 1[kW] three-phase Z-source inverter was producted. The simulation and experiment were performed under the condition that the load was changed in case of the constant input DC voltage and the input DC voltage was changed in case of the load was constant. As a result, we could know that the output phase voltage of Z-source inverter followed to the reference voltage 70[VRMS] despite the load or the input DC voltage were suddenly changed.

Output Signal Characteristics according to Input Signal Characteristics of Two Input Ports in 4-port Coupler Circuit (4단자 커플러 회로에서의 두 개 단자의 입력 신호 특성에 따른 출력 신호 특성)

  • Park, Ung-Hee
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.68-70
    • /
    • 2015
  • The four-port coupler circuit consists of input port, isolation port and two output ports. When it inserts a signal at the input port and the isolation port, the magnitude and phase of the output signal at two output ports are decided by the magnitude and phase of the input signal. This paper analyzes the output signal characteristic of two output ports due to the input signal magnitude and phase of two input ports using the typical 4-port coupler circuit, Branchline hybrid coupler and Ring-hybrid coupler. And, it studies about new way to use branchline hybrid coupler and ring-hybrid coupler on the basis of the this information.

  • PDF

A Study of the economic impacts of lodging industry on the Koran economy using the input-output model (I-O 분석을 이용한 숙박산업의 경제적 효과)

  • Kim, Un-Joung
    • Management & Information Systems Review
    • /
    • v.20
    • /
    • pp.137-156
    • /
    • 2007
  • This study had an objective to obtain a result of the economic impacts of lodging industry on the Koran economy. Using the input-output model(I-O model), lodging industry sectoral multipliers were derived from the effects of output, income, employment, value added. indirect tax, and import. According to results of this study, estimated economic impacts of the convention industry were $2,950 million in output, $712 million in income, 92,257persons in employment, $1,590 million in value added, $12 million in indirect tax, and $226 million in import sectors.

  • PDF

Input-Series Multiple-Output Auxiliary Power Supply Scheme Based on Transformer-Integration for High-Input-Voltage Applications

  • Meng, Tao;Ben, Hongqi;Wei, Guo
    • Journal of Power Electronics
    • /
    • v.12 no.3
    • /
    • pp.439-447
    • /
    • 2012
  • In this paper, an input-series auxiliary power supply scheme is proposed, which is suitable for high input voltage and multiple-output applications. The power supply scheme is based on a two-transistor forward topology, all of the series modules have a common duty ratio, all the switches are turned on and off simultaneously, and the whole circuit has a single power transformer. It does not require an additional controller but still achieves efficient input voltage sharing (IVS) for each series module through its inherent transformer-integration strategy. The IVS process of this power supply scheme is analyzed in detail and the design considerations for the related parameters are given. Finally, a 100W multiple-output auxiliary power supply prototype is built, and the experimental results verify the feasibility of the proposed scheme and the validity of the theoretical analysis.