• 제목/요약/키워드: indoor radon concentration

검색결과 86건 처리시간 0.023초

라돈 환경계통의 제어 매개변수 모델링 (Modeling a Radon Environment System with Dose Sensitivity to the Controllable Parameters)

  • 주운표;김건중;장시영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.753-756
    • /
    • 1991
  • This paper aimed to analyse dose sensitivity to the controllable parameters of in-door radon $(^{222}Rn)$ and its decay products(Rn-D) by applying the input-output linear system theory. Physical behaviors of $^{222}Rn$ & Rn-D were analyzed in terms of $^{222}Rn$ gas generation, -migation and - infiltration to indoor environments, and the performance output-function(i.e. mean dose equivalent to Tracho-Bronchial(TB) lung region was assessed to the following ranges of the controllable parameters; a) the ventilation rate constant $({\lambda}_v)$ : $0{\sun}500[h^{-1}]$. b) the attachment rate constant$({\lambda}_a)$ : 0-500 $[h^{-1}]$. c) deposition rate constant $({\lambda}{_{d}^{u}})$: 0-50$[h^{-1}]$. A linear input-output model was reconstructed from the original models in literatures, as follows, which was modified into the matrices consisting of 111 nodal equations. a) indoor ${222}Rn$ & Rn-D Behaviour: jacobi- Porstendorfer- Bruno model. b) lung dosimerty : Jacobi-Eisfeld model. Some of the major findings, which identify the effectiveness of this model, were as follows. a) ${\lambda}_v$ is most effective, dominant controllable parameters in dose reduction, if mechanical ventilation is applied. b) ${\lambda}_v$, depending on the air particle-concentration, reduces the dose somewhat within ${\lambda}_v$<1 $h^{-1}R range. However, the dose increases conversely, ${\lambda}_v$>1 $h^{-1}R range range. c) ${\lambda}{_{d}^{4}}$ reduces the dose linearly as ${\lambda}_v$ dose. Such dose(z-axis) sentivities are shown with three-dimensional plots whoes x,y-axes are combined 2out the 3 parameter${\lambda}_v{\lambda}_s,\;{\lambda}_d^s$.

  • PDF

의료기관 지하시설의 라돈가스 측정과 내부피폭 조사 (Evaluation of Indoor Radon Levels in a Hospital Underground Space and Internal Exposure)

  • 송재호;진계환
    • 한국방사선학회논문지
    • /
    • 제5권5호
    • /
    • pp.231-235
    • /
    • 2011
  • 라돈($^{222}Rn$)은 지각의 암석이나 토양 또는 건축자재 중에 들어 있는 우라늄($^{238}U$)과 토륨($^{232}Th$)이 몇 단계의 방사성붕괴과정을 거친 후 생성되는 무색무취의 불활성기체로 광산이나 지하같이 밀폐된 공간에 잘 축적된다. 호흡기를 통하여 폐로 유입되고 라돈의 딸핵종이 폐나 기관지에 침적되어 폐암을 일으키는 원인이 된다. 사람의 생명을 다루는 의료기관에서의 라돈피폭은 평상시 방사선피폭량이 많은 방사선관계종사자와 면역력이 약한 환자에게 큰 위험이 될 수 있다는 판단에 이 실험을 실시하였다. 실험에 쓰인 계측기는 실시간 라돈측정기인 Professional Continuous Radon monitor이며 계측장소는 두 개의 병원 지하1층에서 지상2층까지 층별로 오전 10시부터 오후 3시까지 측정 하였다. Professional Continuous Radon monitor계측결과는 최소 14.8 Bq/$m^3$에서 최대 70.3 Bq/$m^3$로 국내기준치인 148 Bq/$m^3$이하로 나타났으며 유효선량은 최소 0.296 mSv에서 최대 1.406 mSv로 일년간 자연방사선으로부터 피폭되는 방사선량인 2.4 mSv의 10~58.3% 수준으로 나타났다.

국내 일부학교 건축물의 실내공기질 평가 (The Assessment of Survey on the Indoor Air Quality at Schools in Korea)

  • 손종렬;노영만;손부순
    • 한국환경보건학회지
    • /
    • 제32권2호
    • /
    • pp.140-148
    • /
    • 2006
  • Recently, indoor air quality (IAQ) in workplace, residential environments and schools has been concerned of people, scientists and related the public, and has recognized the health effects related to indoor air pollution. Therefore, this study was performed to investigate the characteristics of IAQ in 55 kindergartens, elementary school, middle schools, and high schools from June, 2004 to May, 2005 in Korea. We measured indoor air pollutants($PM_{10},\;CO_2$, HCHO, total bacteria colony(TBC), CO, radon, TVOCs, asbestos, and $O_3$), and physical factors(noise, temperature, relative humidity, and illumination) with necessary of management for IAQ in school. We classified into 5 kinds of the school by period since building completion, <1 year, 1-3 years, 3-5 years, and 5-10 years. The concentration of pollutants and the level of physical factors compared with standards and guidelines of IAQ on the Ministry of Environment, the Ministry of Health and Welfare, and the Ministry of Education and Human Resources Development. The major results obtained from this study were as follows. Temperature, relative humidity and illumination among the physical factors did not exceed the standards, but noise exceeded it. Asbestos and $O_3$ did not detect in surveyed classrooms. CO, TBC, TVOCs, and HCHO in kindergartens, TBC in elementary schools, TBC, TVOCs dnd HCHO in middle schools, and HCHO in high schools detected the standards. This study is conducted as a part of efforts to provide a foundational data for further relative researches on management of IAQ of school. Therefore, we suggest that country plan for management of IAQ in school should be established through long-term and continuous investigation for assessment on IAQ in school and health risk assessment for students.

가계의 이질적 선호가 비시장재 가치의 추정에 미치는 영향 (The Effect of Heterogeneous Preference on Non-market Valuation)

  • 김용주
    • 자원ㆍ환경경제연구
    • /
    • 제16권4호
    • /
    • pp.873-900
    • /
    • 2007
  • 비시장재의 가치를 추정하는 많은 연구들은 비시장재에 대한 선호가 모든 경제주체에 있어서 동질적이라고 가정한다. 그러나 현실적으로 비시장재에 대한 선호가 경제주체마다 다를 수 있기 때문에 경제주체간 선호의 이질성을 가정하는 것이 합리적이며 가치추정의 편의를 감소시키게 될 것이다. 본 연구는 방사성 오염 물질인 라돈 가스 농도의 저감에 대한 선호와 도로교통 및 원자력발전의 안전에 대한 선호가 각각 가계들 사이에 이질적일 것인지, 그리고 가계들의 선호가 동질적임을 가정하는 경우에 비해 모형 및 비시장재 가치 추정에 어떠한 영향을 미치는지 분석하였다. 속성가치선택법(choice experiments)과 중첩로짓(mixed logit) 모형을 이용한 결과, 이질적 선호를 허용하는 것이 이를 배제하는 것보다 설명력 있는 모형을 가져다 주었다. 그리고 라돈 농도 저감 및 도로교통 안전 각각에 대하여 이질적 선호가 가계들 사이에 뚜렷이 존재하는 것으로 나타났다. 그러나 원자력발전 안전에 대한 선호의 이질성은 뚜렷이 존재하지 않았다. 이질적 선호를 배제하는 경우와 비교할 때 이를 허용하는 경우의 지불의사액은 라돈 농도 저감의 경우에 평균 2.44배 증가하였으며, 도로교통 안전의 경우에는 1.74배 증가하였다.

  • PDF

지상과 지하역사의 실내공기질 특성과 외기영향 평가 (Characteristics of indoor air quality in the overground and underground railway stations)

  • 남궁형규;송지한;김수연;김희만;권순박
    • 한국산학기술학회논문지
    • /
    • 제17권5호
    • /
    • pp.17-25
    • /
    • 2016
  • 본 연구에서는 지하역사와 지상역사에서의 실내공기질을 측정하고, 외부 공기에 의한 영향 정도를 확인하고자 하였다. 측정된 물질은 '실내공기질 관리법'상에서 유지기준과 권고기준으로 지정된 항목 중, 농도가 검출되지 않은 석면을 제외한 미세먼지($PM_{10}$), 이산화탄소($CO_2$), 일산화탄소(CO), 이산화질소($NO_2$), 폼알데하이드(HCHO), 오존($O_3$), 총부유세균(TAB), 총휘발성유기화합물(TVOC), 라돈 등 9종이다. 또한 미세먼지, 이산화질소, 오존 등 세 가지 물질은 I/O ratio를 통해 외기에의한 영향을 확인하였다. 공기질 측정결과 지상역사에 비해 지하역사에서 미세먼지, 폼알데하이드, 총휘발성유기화합물, 이산화질소, 라돈 등이 높은 농도로 검출되었으며, 이는 지하역사 내부에 그 오염물질의 발생요소가 존재하기 때문으로 판단된다. 오존 농도는 지상역사에서 지하역사보다 높은 농도로 검출되었으며, 특히 외부로 노출되어있는 지상역사 승강장에서 높은 농도를 보임으로써 외기 유입에 의한 영향이 있는 것으로 확인되었다. 따라서, 외기에 의한 영향을 받는 오염물질은 역사의 기계환기시 제거 과정을 거쳐 오염물질의 실내유입을 차단하고, 지하역사에서 기인한 미세먼지 등의 물질들은 실내에서 그 발생원에 따른 별도의 처리가 필요할 것으로 판단된다.

광주지역 다중이용시설에서 실내공기질 농도와 상관성 분석 (The Concentration of Indoor Air Quality and Correlations of Materials at Multiple-use Facilities in Gwangju)

  • 이대행;이세행;배석진;김난희;박강수;김도술;백계진;문용운
    • 대한환경공학회지
    • /
    • 제32권11호
    • /
    • pp.1001-1010
    • /
    • 2010
  • 광주지역 다중이용시설 54개소와 공중이용시설 15개소에 대한 입자상물질(미세먼지, 석면), 가스상물질($CO_2$, CO, $NO_2$, HCHO, Rn, VOCs), 총부유세균의 농도에 대해서 조사하고 각 항목간의 상관성분석을 실시하였다. 미세먼지($PM_{10}$)는 실내주차장에서 평균 $69.2\;{\mu}g/m^3$로 가장 높았고, 이어서 보육시설, 대규모점포, 지하역사 순이었다. 일산화탄소는 실내주차장에서 평균 2.7 ppm으로 가장 높았고, 이산화탄소는 의료시설에서 604.1 ppm으로 가장 높았으며, 이산화질소는 실내주차장에서 0.036 ppm으로 가장 높았다. 포름알데하이드는 54개 전체시설에서 기하평균 $3.6\;{\mu}g/m^3$이었으며, 미술관은 $631.8\;{\mu}g/m^3$로 가장 높았다. 휘발성유기화합물질(VOCs)은 모든 시설에서 기하평균 $24.14\;{\mu}g/m^3$이었고, 이 중 톨루엔이 $15.30\;{\mu}g/m^3$로 가장 높았으며, 이어서 자일렌, 에틸벤젠, 벤젠, 스티렌 순으로 조사되었다. 총부유세균은 찜질방에서 평균 $625.3\;CFU/m^3$로 가장 높았고, 보육시설, 의료기관, 대규모점포 순이었다. 석면은 보육시설에서, 라돈은 미술관에서 높은 것으로 조사되었다. 보육시설에서 미세먼지와 총부유세균은 로그함수의 결정계수($R^2$) 0.5332로 양의 상관성을 보여주었고, 이산화탄소와 일산화탄소는 보육시설과 실내주차장에서 양의 상관성을 보여주었다. 휘발성물질간의 상관식은 모든시설에서 직선함수보다는 로그함수에 의해 잘 설명되었다.