Evaluation of Indoor Radon Levels in a Hospital Underground Space and Internal Exposure

의료기관 지하시설의 라돈가스 측정과 내부피폭 조사

  • Received : 2011.06.14
  • Accepted : 2011.10.20
  • Published : 2011.10.31

Abstract

Radium is rock or soil of crust or uranium of building materials and thorium after radioactivity collapse process are created colorless and odorless inert gas that accrue well in sealed space like mine or basement. It inflow to lung circulate respiratory organ and caused lung cancer because of deposition of lung or bronchial tubes. Radium sheath of medical institution treat person's life is possible big danger to professional regarding radioactivity who has much amount exposed radioactivity and weaker immune patient. so we do this test. Using measuring instrument at test is real time radium measuring instrument, Professional Continuous Radon monitor, and measuring places are basement first floor and second floor of two hospitals and measure from 10 a.m to 3 p.m. Measurement result of Professional Continuous Radon monitor is minimum 14.8 Bq/$m^3$ to maximum 70.3 Bq/$m^3$ and show domestic baseline below 148 Bq/$m^3$, effective dose-rate is minimum 0.296 mSv to maximum 1.406 mSv that show 2.4 mSv, 10~58.3% level, exposed radiation amount from nature radiation one year.

라돈($^{222}Rn$)은 지각의 암석이나 토양 또는 건축자재 중에 들어 있는 우라늄($^{238}U$)과 토륨($^{232}Th$)이 몇 단계의 방사성붕괴과정을 거친 후 생성되는 무색무취의 불활성기체로 광산이나 지하같이 밀폐된 공간에 잘 축적된다. 호흡기를 통하여 폐로 유입되고 라돈의 딸핵종이 폐나 기관지에 침적되어 폐암을 일으키는 원인이 된다. 사람의 생명을 다루는 의료기관에서의 라돈피폭은 평상시 방사선피폭량이 많은 방사선관계종사자와 면역력이 약한 환자에게 큰 위험이 될 수 있다는 판단에 이 실험을 실시하였다. 실험에 쓰인 계측기는 실시간 라돈측정기인 Professional Continuous Radon monitor이며 계측장소는 두 개의 병원 지하1층에서 지상2층까지 층별로 오전 10시부터 오후 3시까지 측정 하였다. Professional Continuous Radon monitor계측결과는 최소 14.8 Bq/$m^3$에서 최대 70.3 Bq/$m^3$로 국내기준치인 148 Bq/$m^3$이하로 나타났으며 유효선량은 최소 0.296 mSv에서 최대 1.406 mSv로 일년간 자연방사선으로부터 피폭되는 방사선량인 2.4 mSv의 10~58.3% 수준으로 나타났다.

Keywords

Acknowledgement

Supported by : 한국연구재단

References

  1. Sources and Effects of Ionizing Radiation, 2000, Report UNSCEAR 2000, Vol. 1, pp.1-13, 2006.
  2. Recommendations of the International Commission on Radiological Protection Publication (Korean), Vol. 103, pp.1-418, 2007.
  3. EPA Assessment of Risk from Radon in Homes(EPA 402-R-03-003)
  4. WHO, Handbook on Indoor Radon, pp.3-14, 2009.
  5. 방사선방호 등에 관한 기준 고시 : 교육과학기술부고시 제2009-37호.
  6. 고상기 전국 라돈 실태 조사 : 부산대학교, pp.1-145, 2009.

Cited by

  1. Elementary School in Gwangju Gwangsan Radon gas Density Measurement vol.8, pp.4, 2014, https://doi.org/10.7742/jksr.2014.8.4.211
  2. Radon Concentration at N-Kindergarten in G-City vol.9, pp.6, 2015, https://doi.org/10.7742/jksr.2015.9.6.421
  3. 대학의 실내 라돈가스 농도의 변화 평가 vol.40, pp.1, 2011, https://doi.org/10.17946/jrst.2017.40.1.18
  4. 대학 내 학습공간과 공동 생활공간에 대한 실내 라돈 농도 측정과 유효선량 산출 vol.12, pp.3, 2011, https://doi.org/10.7742/jksr.2018.12.3.329
  5. Influence of soil and building materials on indoor radon in underground buildings vol.18, pp.3, 2011, https://doi.org/10.15250/joie.2019.18.3.272
  6. 일상생활에서 사용하는 마스크의 라돈 차단 효과 vol.14, pp.3, 2020, https://doi.org/10.7742/jksr.2020.14.3.313