• 제목/요약/키워드: indoor and outdoor

검색결과 1,344건 처리시간 0.03초

안전교육에 대한 초등학교 교과서 내용 분석 (Contents Analysis of Textbook Related to Safety Education in Elementary School)

  • 송미경;이정은;문선영;양숙자;김신정
    • 지역사회간호학회지
    • /
    • 제16권2호
    • /
    • pp.205-220
    • /
    • 2005
  • Purpose: The purpose of this study was to provide basic data to develop safety education programs in elementary school. Method: Analysis is made based on textbooks for $1st-{\sim}6th-grade$ elementary school students published by Korea Ministry of Education & Human Resources Development. Results: 1) Among the textbooks. only , . , and courses dealt with safety education. 2) The contents of safety education included traffic safety, water safety, indoor and outdoor safety, fire, emergency measures, misuse and abuse of drug, smoking, toy safety, sports safety, leasure safety and disasters. However, the contents were theoretical, fragmentary, local and limited. Conclusion: These results suggest that the consents of safety education must be strengthened, and more practical and more behavior-oriented in consideration of activities.

  • PDF

무선 마이크에 대한 DTV 서비스 간섭 영향 분석 (The Interference Effect of DTV Service on Radio Microphone)

  • 심용섭;이일규;정연명
    • 한국인터넷방송통신학회논문지
    • /
    • 제10권2호
    • /
    • pp.19-24
    • /
    • 2010
  • 본 논문은 방송통신위원회의 정책에 따라 DTV 전환시 예상할 수 있는 DTV 서비스가 인접채널에 할당될 무선 마이크에 간섭을 주는 영향을 분석하였다. 분석을 위해 DTV 서비스가 채널 51(692 MHz ~ 698 MHz)에 할당되고 무선 마이크가 채널 52(698 MHz ~ 704 MHz)에 할당되는 시나리오를 가정하였다. Minimum Coupling Loss(MCL)를 이용하여 보호 이격거리를 산출하고 몬테 칼로(Monte Carlo) 분석을 이용하여 간섭 확률 0 %를 위한 보호 대역을 산출하였다. 그 결과 실내의 경우 1.71 km의 보호 이격거리와 2.4 MHz의 보호 대역이 산출되었고 실외의 경우 18.86 km의 보호 이격거리와 5.7 MHz의 보호 대역이 산출되었다.

지역난방 2차측 유량변화가 내부 열유속 및 에너지소비량에 미치는 영향에 관한 실험적 연구 (The Experimental Study of the Heat Flux and Energy Consumption on Variable Flow Rate for Secondary Side of DHS)

  • 홍성기;조성환
    • 설비공학논문집
    • /
    • 제27권5호
    • /
    • pp.247-253
    • /
    • 2015
  • The presented work demonstrates the effects of flow rate on the secondary side of DHS (District Heating System). Increasing flow rate at the secondary side of DHS decreases energy consumption and time to reach the set-point of the heated room while increasing heat flux on the floor in the heating space. When flow rate increases, the overall heat transfer rate of radiant floor also increases. However, the results also show overall heat transfer rateto not increased linearly and thus the existence of an optimal flow rate for the secondary side of DHS. Control of the radiant floor with hot water may be more effectively accomplished with a combined control strategy that includes heat flux and a temperature set-point. This experimental analysis has been performed using a lab-scaled DHS pilot plant located at Jeonju University in Korea.

Service Life Estimation of ACQ-treated Wood Based on Biodeterioration Resistance

  • Pang, Sung-Jun;Hong, Jung-Pyo;Lee, Jun-Jae;Oh, Jung-Kwon
    • Journal of the Korean Wood Science and Technology
    • /
    • 제43권5호
    • /
    • pp.641-651
    • /
    • 2015
  • The aim of this study was to estimate the service life of alkaline copper quaternary (ACQ)-treated wood. The service life of preservative-treated wood was estimated by comparing a residual quantity of ACQ in wood with toxic threshold to fungi. Indoor and outdoor leaching tests were carried out in order to predict residual ACQ quantity within wood. As a result, the leaching ratio of ACQ from treated wood above ground via precipitation was 18.1% for 50 years. When the H4 treated wood, which is traditionally used in contact with the ground and fresh water, is used above-ground, the leaching ratio of ACQ for 50 years is 18.1% and the residual quantity of ACQ is $4.2kg/m^3$, which is higher than the toxic threshold of ACQ. Thus, the H4 treated wood used above-ground will be resistant to biodeterioration for at least 50 years.

인간동력항공기 조종사 훈련 및 성과 (Training and Performances of the HPA Pilot)

  • 장상현;이정원
    • 항공우주기술
    • /
    • 제12권2호
    • /
    • pp.202-208
    • /
    • 2013
  • 본 논문에서는 기계적 동력을 이용하지 않고 오직 인간의 근육에서 발생된 에너지를 이용하여 이착륙 및 비행을 할 수 있는 인간동력항공기의 조종사 훈련 계획 수립, 훈련 및 성과에 관해 기술하였다. 이를 위해 전문 트레이너는 각 조종사들의 신체적 특성을 고려하여 훈련 계획을 수립하였으며, 조종사들은 기초 체력 증진을 위한 실내 트레이닝, 균일한 동력 발생을 위한 실외 트레이닝, 조향 능력 습득을 위한 시뮬레이션 교육 및 경비행기 탑승을 실시하였다. 훈련을 통해 조종사의 몸무게 감소 및 체력 향상을 확인할 수 있었으며, 비행에 필요한 기본적인 비행 운용 능력을 습득하였다.

Evaluation of the effect of smart façade systems in reducing dynamic response of structures subjected to seismic loads

  • Samali, Bijan;Abtahi, Pouya
    • Earthquakes and Structures
    • /
    • 제11권6호
    • /
    • pp.983-1000
    • /
    • 2016
  • To date the engineering community has seen facade systems as non-structural elements with high aesthetic value and a barrier between the outdoor and indoor environments. The role of facades in energy use in a building has also been recognized and the industry is also witnessing the emergence of many energy efficient facade systems. This paper will focus on using exterior skin of the double skin facade system as a dissipative movable element during earthquake excitation. The main aim of this study is to investigate the potential of the facade system to act as a damper system to reduce earthquake-induced vibration of the primary structure. Unlike traditional mass dampers, which are usually placed at the top level of structures, the movable/smart double skin facade systems are distributed throughout the entire height of building structures. The outer skin is moveable and can act as a multi tuned mass dampers (MTMDs) that move and dissipate energy during strong earthquake motions. In this paper, using a three dimensional 10-storey building structure as the example, it is shown that with optimal choice of materials for stiffness and damping of brackets connecting the two skins, a substantial portion of earthquake induced vibration energy can be dissipated which leads to avoiding expensive ductile seismic designs. It is shown that the engineering demand parameters (EDPs) for a low-rise building structures subjected to moderate to severe earthquakes can be substantially reduced by introduction of a smart designed double skin system.

대전지역 사육견의 심장사상충 감염실태 조사 (Prevalence of Heartworm disease in Dogs of Daejeon Area)

  • 장승익;송운재;하숙희;이상준;정년기;문병천
    • 한국동물위생학회지
    • /
    • 제27권2호
    • /
    • pp.133-137
    • /
    • 2004
  • This study was attempted to survey on the prevalence of canine heartworm(Dirofilaria immitis) infections among 206 dogs (male 92, female 114) in Daejeon area from March to December 2003. Blood samples taken from dogs were examined for the presence of D immitis microfilaria by the modified Knott's test and an antigen test( $AGEN^{TM}$ canine heartworm). The result obtained from this experiment were summarized as follows; 1. Eighteen(8.7%) of the 206 examined dogs were microfilaria positive, while twenty five dogs(12.1%) were antigen test positive. 2. The infection rates of heartworm in dogs at the age of <2, 2∼4 and $\geq$5 were 3.8%, 18% and 25%, respectively. 3. The infection rates of heartworm in dogs by housing of indoor and outdoor were 3.3% and 36.4%, respectively. 4. The regional infection rates were Dong-gu(13/29, 44.8%), Seo-gu(7/92, 7.6%), Yuseong-gu(2/33, 6.1%), Jung-gu(1/17, 5.9%) and Daedeok-gu(2/35, 5.7%). 5. The seasonal infection rates were summer(June∼August, 16.7%), autumn (September∼October, 14%), spring(March∼May, 9.4%) and winter(November∼December. 7.7%).7.7%).

고층건물에서 연돌효과를 활용한 자연환기시스템 설계를 위한 이론적 고찰 (A Theoretical Study for Stack Effect driven Natural Ventilation System in High-rise Building)

  • 윤성민;서정민;김양수;이중훈;송두삼
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.123-129
    • /
    • 2009
  • In these days, the green building movement caused by the energy crisis is increasing, passive design is getting mere and more attention as it provides many possibilities for energy conservation. Moreover, with the increasing social intention for healthy life, the demand for indoor air Quality is increasing in Korea. As result, the ventilation system which can provide the sound outdoor air constantly has been obliged in Korea. So, the hybrid system which using natural power and mechanical power and makes up for the shortage of mechanical and natural ventilation attracts people's attention in Korea. As a hybrid ventilation system, in this study, the stack effect driven hybrid ventilation system in high-rise residential building will be suggested. And in this paper, the theoretical review for hybrid ventilation system suggested in this study will be addressed. Especially, the characteristics of pressure distribution and airflow caused by stack effect in high-rise residential building and the possibility of natural ventilation as results of stack effect will be described.

  • PDF

양안식 3D 텔레비전 영상의 화질 평가와 분석 (Quality Assessment and Analysis of Stereoscopic 3D Television Pictures)

  • 박대철
    • 융합신호처리학회논문지
    • /
    • 제11권4호
    • /
    • pp.278-288
    • /
    • 2010
  • 본 논문에서는 ITU-R 기고문과 권고안에 따라 양안 업체 영상에 대한 화질, 깊이감, 명료성, 실재감 항목을 모노 영상에 대비하여 DSCQS(Double-Stimuli Continuous Quality Scale) 방법을 사용하여 평정척도법에 의해 분석하였다. 평가 결과는 자연 실외 영상, 그래픽 영상, 실내 영상으로 구성된 평가 대상 영상에 대하여 전반적인 화질의 차나 명료성은 모노인 경우나 입체 영상인 경우나 별 차이를 나타내지 않았으나(대강 3.0 이상 -4.0 이하), 입체 영상의 깊이감 인지와 실재감에 대해서는 업체 영상인 경우 모두 5.0등급 중 4.0 등급 이상을 나타내어 깊이감 및 실재감 정보가 주는 인상이 매우 큼을 시사해준다. 양안 3DTV 촬영이나 편집시 시차 등 휴먼 팩터로 평가결과가 고려되어져야 할 것이다.

청각장애인을 위한 웨어러블 기기의 위험소리 검출 엔진 설계 (A Design of Dangerous Sound Detection Engine of Wearable Device for Hearing Impaired Persons)

  • 변성우;이석필
    • 전기학회논문지
    • /
    • 제65권7호
    • /
    • pp.1263-1269
    • /
    • 2016
  • Hearing impaired persons are exposed to the danger since they can't be aware of many dangerous situations like fire alarms, car hones and so on. Therefore they need haptic or visual informations when they meet dangerous situations. In this paper, we design a dangerous sound detection engine for hearing impaired. We consider four dangerous indoor situations such as a boiled sound of kettle, a fire alarm, a door bell and a phone ringing. For outdoor, two dangerous situations such as a car horn and a siren of emergency vehicle are considered. For a test, 6 data sets are collected from those six situations. we extract LPC, LPCC and MFCC as feature vectors from the collected data and compare the vectors for feasibility. Finally we design a matching engine using an artificial neural network and perform classification tests. We perform classification tests for 3 times considering the use outdoors and indoors. The test result shows the feasibility for the dangerous sound detection.