• Title/Summary/Keyword: indoor and outdoor

Search Result 1,344, Processing Time 0.029 seconds

Community Shared Space Planning for Vitalization of For-Profit Urban Elderly Welfare Housing (도시형 유료노인복지주택의 활성화를 위한 공용공간 계획)

  • Jang, Eun-Hye;Kim, Mi-Kyoung
    • Korean Institute of Interior Design Journal
    • /
    • v.22 no.1
    • /
    • pp.318-327
    • /
    • 2013
  • Elderly welfare housing refers to a residential facility with diverse medical and welfare services for cohabitation of elderly. Especially, community shared spaces in the elderly welfare housing plays an important role as a place for community and leisure activities that enhance vitality of elderly life. The purpose of this study was to investigate types, planning characteristics and actual utilization of community shared spaces in for-profit elderly welfare housing. Eight for-profit elderly welfare housing facilities in Seoul and Gyeonggi province were selected for this study and categorized into small-, medium- and large-scale facilities based on the number of housing units. Community shared spaces in the elderly welfare housing were classified into six space types: social space, education space, exercise space, medical space, convenience space and leisure space. Findings are as follows. Small-scale elderly welfare housing facilities with less than 100 housing units had fitness centers, clinics, restaurants, convenience stores and hobby rooms which were required by law. All community shared spaces were planned on a single level. Fitness centers was found the most frequently used while the other spaces were not used very frequently. Medium-scale facilities with 100 to 299 housing units had multi-purpose halls, libraries, swimming pools, indoor and/or outdoor driving ranges, physical therapy centers, saunas, karaokes and so on. Most community shared spaces were found frequently used. Large-scale facilities with 300 or more housing units had religion rooms, community halls, hair salons, pharmacies, etc. In most facilities, community shared spaces were planned in distributed locations.

Application of Natural Dyes for Developing Colored Wood Furniture (III) - Prevention of Discoloration of Chestnut Wood by Natural Dyes - (색채 목가구 개발을 위한 천연염료의 이용에 관한 연구(제3보) - 천연염색 밤나무 목재의 변색 방지 -)

  • Moon, Sun-Ok;Kim, Chul-Hwan;Kim, Gyeong-Yun;Jung, Ho-Gyeong;Shin, Tae-Gi;Kim, Jong-Gab;Park, Chong-Yawl
    • Journal of the Korean Wood Science and Technology
    • /
    • v.35 no.3
    • /
    • pp.79-87
    • /
    • 2007
  • This study investigated the effects of lacquer-finishing to prevent discoloration of coloring chestnut wood coated with natural dyes from deteriorating factors such as lights (indoor, 500 lux and outdoor, 50,000~70,000 lux), acid, alkali, and heat through measurement of color difference. Lacquer-finishing coating contributed to protection of intrinsic color of the natural dyeing woods in spite of severe treatment. In particular, dyeing liquor with alkali pH played a great role in prevention of light discoloration.

Influence of Stack Effect in High-Rise Buildings on Wind Effect in Jeju (Comparative Analysis of Seoul and Jeju) (제주지역 고층건축물에서의 바람의 영향이 굴뚝효과에 미치는 영향 분석 (서울과 제주지역간의 비교 분석))

  • Lim, Chae-Hyun
    • Fire Science and Engineering
    • /
    • v.29 no.6
    • /
    • pp.6-12
    • /
    • 2015
  • This study used CONTAM modeling to analyzed analyze the stack effect in high-rise buildings for the terrain and weather conditions of Seoul and Jeju. The differential pressure caused by the stack effect is a function of the indoor and outdoor temperature difference and the height of the vertical shaft. Jeju is considered more stable than Seoul, because it is warmer than Seoul in winter. The differential pressure in Jeju is about 60% that of Seoul in for the same height of buildings in winter. However, Jeju is an island and the neutral plane is raised by over 56% by strong winds, although there is less differential pressure caused by the stack effect in Jeju than in Seoul. Due to the raised neutral plane, the region and magnitude of negative pressure in the lower part is larger in Jeju than in Seoul.

A Study on the Performance Characteristics of a Heat Pump System using Stack Wast Heat in Fuel Cell Vehicles (스택 폐열을 이용한 연료전지 자동차용 열펌프 시스템의 성능 특성에 관한 연구)

  • Jeon, Byungyong;Ko, Wonbin;Park, Youn Cheol
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.8
    • /
    • pp.325-330
    • /
    • 2016
  • This study was conducted to develop a heating system for a fuel cell-driven electric vehicle. The system consists of a compressor, an expansion device and three heat exchangers. A conventional air source heat exchanger is used as primary heat exchanger of the system, and an additional water source heat exchanger is used as a pre-heater to supply heat to the upstream air of the primary heat exchanger. On the other hand, the third heat exchanger consists of a water-to-refrigerant heat exchanger. The heat source of the pre-heater and the water-refrigerant heat exchanger is the waste heat from the fuel cell's stack. In the experiment, the indoor and the outdoor air temperature were fixed, and the compressor speed, EEV opening and waste heat temperature were varied. The results indicate that the $COP_h$ of the proposed system is 3.01 when the system is operating at a 1,200 rpm compressor speed, 50% EEV opening, and $50^{\circ}C$ waste heat source temperature in air pre-heater operation. However, when the system uses a water-refrigerant heat exchanger, the $COP_h$ increases to up to 9.42 at the same compressor speed and waste heat source temperature with 75% EEV openings.

Prevalence study of respiratory pathogens in Korean cats using real-time polymerase chain reaction

  • Lee, Mi-Jin;Park, Jin-ho
    • Korean Journal of Veterinary Service
    • /
    • v.45 no.3
    • /
    • pp.145-153
    • /
    • 2022
  • Pathogens such as feline herpesvirus, feline calicivirus, Bordetella bronchiseptica, Chlamydia felis, Mycoplasma felis and Pasteurella multocida usually cause feline upper respiratory tract disease (URTD). Real-time PCR was used to analyze the detection and prevalence of the most common respiratory pathogens in cats with (n=69) and without respiratory signs (n=31). Pathogens were detected in 53 cats, divided into 37 (69.8%) with a single pathogen, 15 (28.3%) with two pathogens, and 1 (1.9%) with three pathogens. M. felis had the highest detection rate in 29 (42.0%) cats, P. multocida was detected in 18 (26.1%), FHV in 10 (14.5%), FCV in 7 (10.1%), B. bronchiseptica in 3 (4.3%), and C. felis in 2 (2.9%). M. felis was the most frequently detected pathogen in cats living outdoors without vaccination. Of the 37 cats infected with single pathogen, nasal discharge was observed in 13 (35.1%), ocular signs in 6 (16.2%), drooling in 5 (13.5%), dyspnea in 3 (8.1%), and asymptomatic in 10 (27.0%). In 51 outdoor and 49 indoor cats, pathogens were detected in 35 (68.6%) and 18 (36.7%) cats, respectively. Of the 29 cats infected with M. felis, 22 (75.9%) showed respiratory signs, and 7 (24.1%) were healthy. In the age of the 53 positive cats, 10 (18.9%) were under the age of 1 year, 26 (49.1%) were aged 1~3 years, and 17 (32.1%) were aged 3 years or older. Although the number of cats in the study was small, the results can provide valuable data on the prevalence of URTD in Korean cats.

Radiometric examination of fertilizers and assessment of their health hazards, commonly used in Pakistan

  • Hannan Younis;Sumbilah Shafique;Zahida Ehsan;Aleena Ishfaq;Khurram Mehboob;Muhammad Ajaz;Abdullah Hidayat;Wazir Muhammad
    • Nuclear Engineering and Technology
    • /
    • v.55 no.7
    • /
    • pp.2447-2453
    • /
    • 2023
  • The radioactivity concentrations of Naturally Occurring Radioactive Materials (NORM) i.e., 226Ra, 232Th, and 4K in various chemical fertilizers being used in the agricultural soil of Pakistan were determined utilizing gamma spectrometry by employing a High Purity Germanium (HPGe) detector. The radioactivity concentrations of 226Ra, 232Th, and 4K extended from 2.58 ± 0.8-265.7 ± 8.8 Bq kg-1, 1.53 ± 0.14-76.6 ± 1.07 Bq kg-1 and 36.5 ± 1.34-15606.7 ± 30.2 Bq kg-1 respectively. The radiological hazard parameters such as internal and external indices and annual effective dose rates were calculated, while excessive lifetime cancer risk factors for the indoor and outdoor areas were found in the range from 0.3×10-3 to 10.723×10-3 and 0.03×10-3 to 2.7948×10-3 of most fertilizers, however, some values were slightly higher than the UNSCEAR (The United Nations Scientific Committee on the Effects of Atomic Radiation) recommended values for potash-containing fertilizers such as MOP (Muriate of Potash).

Survey Research on Thermal Situation of Office Buildings (사무소 건축물의 단열상황에 관한 조사연구)

  • Jung, Ui In;Kim, Bong Joo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.3
    • /
    • pp.145-152
    • /
    • 2013
  • This study is to evaluate the thermal insulation of the curtain wall of the buildings constructed since the 1990s to the buildings currently under construction in 2011 and to provide the basic data for repairing and reinforcing and designing the thermal insulation. To this effect, the temperature difference by part was analyzed through measuring the inside and outside surface temperature of the curtain wall of the office building, and thereafter, the conditions of the thermal insulation and the thermal bridge part were examined. The result of the study is as follows; Not only in the winter season when the temperature difference between the indoor-outdoor is over $20^{\circ}C$, but also in the summer season when there is a small temperature difference, the temperature difference between the inside and outside of the frame is $2^{\circ}C{\sim}4^{\circ}C$ equally. Under such conditions as stated above, the thermal bridge occurred, which resulted from the heat flow of the steel frame part (mullion, transom), and therefore, the reinforcement of the thermal insulation is considered to be needed.

Job Stress of Mobile Communication Network Construction Workers

  • Lee, Dong-Gu;Yoon, Hoon-Yong
    • Journal of the Ergonomics Society of Korea
    • /
    • v.34 no.6
    • /
    • pp.549-561
    • /
    • 2015
  • Objective: The purpose of this study was to investigate the job stress factors of mobile communication network construction workers using survey based on 'Job stress factors evaluation tool for Koreans' that was developed by KOSHA in 2003. Background: Due to the rapid growth of penetration rate of smartphone, the necessity of LTE service changing from 3G network was brought up. The demand of LTE network construction in a short period of time leads to the aggravation of the job stress of mobile communication network construction workers. Method: Two hundred and fifty workers who were in the mobile communication network industry participated in this study, and among them 206 responses were analyzed for this study due to the unreliability and insincerity of responses. The eight job stress factors which are physical environment, job demand, job autonomy, relation conflict, job instability, organizational system, inadequate compensation, workplace culture were analyzed. Results: The job stress factors of mobile communication network construction workers were compared to those of other industry workers, and other work related characteristics were analyzed. The results showed that the stress level of a physical environment and job requirement were relatively higher than those of manufacturing industry workers, meaning that mobile communication network construction workers have rough working conditions and increased amount of work due to the demand of LTE network construction. The stress level of physical environment for outdoor job workers was relatively higher than that of indoor job workers. With the analytical result for level of job satisfaction, significant difference was observed (p <0.05) with every factor, and the job stress was found the highest with those not satisfied with every factor Conclusion: From the results of this study, the work loss due to the job stress could be prevented, and accurate stress factors could be removed at the workplace. Application: The results of this study may not represent the whole mobile network construction workers, the effort for job stress management is needed to improve the work efficiency and the workers' quality of life.

Playground Facilities for Physically Challenged Children (지체장애 아동을 위한 옥외 놀이시설)

  • 김학범;이은희
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.30 no.4
    • /
    • pp.47-65
    • /
    • 2002
  • The purpose of this paper is to study and propose playground facilities for physically challenged children to cultivate adaptability in society and advances the opportunity of participate in physical exercise. This study carried out site investigations by visiting and inspecting various facilities: a recreational walking path for physically challenged people, a care facility for physically challenged children, a special school for physically challenged children, and "Madel Park", a private-use playground for physically challenged children. The result of the site investigation found that, overall, play facilities are difficult to use for physically challenged children. In addition, because park space is often small and narrow, children who are restricted to wheelchairs find it impossible to access such facilities. By carefully inspecting each of the facilities, the author found suitable elements to apply for outside play space. These elements include the introduction of an essential slope way to allow for safe movement, the provision of special seats which support the body to outside play equipment and the adaptation of treatment room instruments that assist balance to outdoor playground facilities. On the basis of the site investigation the interview and the indoor education program for physically challenged children the author completed an outside play program. Each item in this program was classified as belonging to either a "sense play" program or and "exercise play" program. Finally, the author designed suitable play equipment for physically challenged children corresponding to each item in the exercise programs in order to research the appropriateness of the equipment to its intended use. This research is the first step. From this point the author expects that specific applications will be developed through a practical space plan and sufficient clinical experiments involving use of the new equipment.

Analysis of Tapered Slot Antenna for UWB with Directivity Characteristic (지향성 특성을 갖는 UWB 용 테이퍼드 슬롯 안테나 분석)

  • Kim, Sun-Woong;Choi, Dong-You
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.4
    • /
    • pp.691-697
    • /
    • 2016
  • In this paper, we propose the antenna to appropriate for a UWB communication system, and it meets characteristics for location recognition in predetermined range. Proposed tapered slot antenna was designed through the HFSS simulation tool of Ansys. Inc., it was produced by Taconic TRF-45 based on dielectric constant of 4.5, loss tangent 0.0035, thickness 1.62mm. The tapered slot antenna is analyzed the standing wave ratio and reflection coefficient, radiation pattern in the frequency domain. The impedance bandwidth range of the produced tapered slot antenna is from 3.8 ~ 8.9GHz to 5.1GHz, E-plane and H-plane radiation pattern meet directional antenna characteristics for indoor and outdoor location recognition in predetermined range. The antenna gain is 7.4 dBi(6GHz)in the simulation, the result of measurement demonstrated 7.4 dBi(6 GHz) of antenna maximum gain. Proposed tapered slot antenna meets UWB communication system but simulated and measured results were slightly different.