Browse > Article
http://dx.doi.org/10.11112/jksmi.2013.17.3.145

Survey Research on Thermal Situation of Office Buildings  

Jung, Ui In (공주대학교 건축학부)
Kim, Bong Joo (공주대학교 건축학부)
Publication Information
Journal of the Korea institute for structural maintenance and inspection / v.17, no.3, 2013 , pp. 145-152 More about this Journal
Abstract
This study is to evaluate the thermal insulation of the curtain wall of the buildings constructed since the 1990s to the buildings currently under construction in 2011 and to provide the basic data for repairing and reinforcing and designing the thermal insulation. To this effect, the temperature difference by part was analyzed through measuring the inside and outside surface temperature of the curtain wall of the office building, and thereafter, the conditions of the thermal insulation and the thermal bridge part were examined. The result of the study is as follows; Not only in the winter season when the temperature difference between the indoor-outdoor is over $20^{\circ}C$, but also in the summer season when there is a small temperature difference, the temperature difference between the inside and outside of the frame is $2^{\circ}C{\sim}4^{\circ}C$ equally. Under such conditions as stated above, the thermal bridge occurred, which resulted from the heat flow of the steel frame part (mullion, transom), and therefore, the reinforcement of the thermal insulation is considered to be needed.
Keywords
Curtain wall; Frame; Mullion bar; Spandrel bar; Anchor unit; Heat bridge;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 Kim, B. J., Kim, K. A., Park, J. M., "Insulation Method and Performance Evaluation for Fastening Unit of ALC Pannel- Curtain wall", Academic Journal of the Korea Institute of Building Construction, vol. 11, No. 1, 2011, pp.107-110. (in Korean)
2 Kim, K. A., Kim, B. J., "Heat Loss the Case Study of Office Building", Academic Journal of the Korea Institute of Building Construction, vol. 11, No. 1, 2011, pp.51-54. (in Korean)   DOI   ScienceOn
3 Kim, Y. J., "Study on the energy conservation in residential complex by insulating the fastening unit of curtain wall system", paper of masters degree, Ewha womans Univ., 2005, pp.8-32. (in Korean)
4 Koo, S. Y., Ku, H. Y., Yeo, M. S., Kim, K. W., "Thermal Performance of Opaque Part of the Curtain walls in Buildings", Journal of Architectural Institute of Korea, vol. 28, No. 1, 2008, pp.559-562. (in Korean)
5 Kwon. Y. C., Seo. S. Y., Kim. S. Y., "Thermal Property and Fire Resistance of Cellulose Insulation", Journal of the Korea institute for structural maintenance inspection, vol. 9, No. 3, 2005, pp.203-212. (in Korean)
6 Lee, M. W,, Lee, S. W., Yeo, M. S., Song, S. Y., Kim, G. W., "A Study on the Construction Detail of Joints for Stone Panel Curtain Wall Considering the Prevention of Condensation", Journal of Architectural Institute of Korea, vol. 22, No. 4, 2006, Apr, pp.277-284. (in Korean)   과학기술학회마을
7 Lee, T. C., Yoon, S. H., "Review on Radiation Temperature Distribution of a Multipurpose High-rise Building by Infrared Rays Camera", Journal of Asian Architecture and Building Engineering, vol. 2012, No. 3, 2012, pp.77-80. (in Korean)
8 Lee, Y. G., Lee, S. H., Lee, S. Y., "Effect of Components Assembly and Sizing on the Thermal Performance of Windows", Journal of Architectural Institute of Korea, vol. 22, No. 7, 2006, pp.215-222. (in Korean)   과학기술학회마을
9 Song, S. Y., Kang, K. Y., Yeo, M. S., Kim, G. W., "Influence of Damaged Inside Finish Material for Insulation on the Condensation and Efficient Finish Material to Prevent Interstitial Condensation in Curtain Wall System", Journal of Architectural Institute of Korea, vol. 22, No. 8, 2006, pp.241-249. (in Korean)   과학기술학회마을
10 Song, S. Y., Koo, B. K., Seok, H. T., "Performance Evaluation of the Various Insulation Schemes for Fastening Unit in Aluminum Curtain Wall System of Residential Complex", Journal of Architectural Institute of Korea, vol. 26, No. 1, 2006, pp.609-612. (in Korean)
11 Choi, G. S., Jeong, Y. S., Kang, J. S., Lee, S. E., "Developemnt of In-site Evaluation Method for Building Insulation Performance Using Infra-red Camera", Journal of Architectural Institute of Korea, vol. 24, No. 1, 2004, pp.762-765. (in Korean)
12 Choi, M. Y., Kim, W. T., "The Utilization of Nondestructive Testing and Defects Diagnosis using Infrared Thermography", Journal Of The Korean Society For Nondestructive Testing, vol. 24, No. 5, 2004, pp.525-531. (in Korean)   과학기술학회마을
13 Lee, M. J., Lee, S. W., Yeo, M. S., Kim. G. W., "An Experimental Study on Insulation and Preventing Condensation Performance of Ventilated Curtain Wall", Academic Journal of Air-Conditioning and Refrigeration Engineering of Korea, vol. 2006, No. 6, 2006, pp.1081-1086. (in Korean)