• Title/Summary/Keyword: indoor air environment

Search Result 1,059, Processing Time 0.025 seconds

A Study on Indoor Thermal Environment in an Tower Type Apartment House at Tropical Nights (여름철 열대야 발생시 탑상형 아파트의 실내온열환경에 대한 연구)

  • Chang, Hyun-Jae;Kim, Hyung-Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.1
    • /
    • pp.20-25
    • /
    • 2010
  • In this study, As a basic research for improving indoor thermal environment at tower type apartment houses, specifications of heat storage and heat emission in the structures of apartment houses were investigated, and the ratio of indoor and outdoor air velocity at tower type apartment house was examined, too. Indoor temperature at night time was higher than outdoor air temperature because heat emission from the structure of wall, ceiling and floor those are constructed by use of reinforced concrete which has large heat capacity. The ratio of indoor and outdoor air velocity was lower than 0.1 and this was caused by the plan of tower type apartment house. PMV was in the range of 0.3~1.9, and was about 1.0 (it means slightly warm) at 10 : 00 p.m.. To improve indoor thermal environment in summer season at tower type apartment houses, it needs more investigation on specifications of heat storage and heat emission in the structure including winter season, and on the improvement of the ratio of indoor and outdoor air velocity.

Recent Advances in Titania-based Composites for Photocatalytic Degradation of Indoor Volatile Organic Compounds

  • Raza, Nadeem;Kim, Ki-Hyun;Agbe, Henry;Kailasa, Suresh Kumar;Szulejko, Jan E.;Brown, Richard J.C.
    • Asian Journal of Atmospheric Environment
    • /
    • v.11 no.4
    • /
    • pp.217-234
    • /
    • 2017
  • Indoor air pollutants can cause severe health problems, specifically in terms of toxicological impacts on human. Every day, a complex mixture of many air pollutants is emitted from various sources and subject to atmospheric processes that can create varied classes of pollutants such as carboxylic acids, aldehydes, ketones, peroxyacetyl nitrate, and hydrocarbons. To adhere to indoor air quality standards, a number of techniques such as photocatalytic oxidation of various volatile organic compounds (VOCs) have been employed. Among these techniques, titania ($TiO_2$) based photocatalytic reactions have proven to be the best benchmark standard approach in the field of environmental applications. Over the last 45 years, $TiO_2$-based photocatalytic reactions have been explored for the degradation of various pollutants. This review discusses the indoor air quality profile, types of indoor pollutants, available indoor air cleaning approaches, and performance of $TiO_2$-based catalysts. Finally, we have presented the perspectives on the progress of $TiO_2$ induced photocatalysis for the purification of indoor air.

Assessment of Conscious Coginition Degree and Survey on Oxyen Generators using the Indoor Environment (실내환경중의 산소발생기 사용에 대한 인식도 평가)

  • 손종렬;조윤수;이규현;황상용
    • Journal of environmental and Sanitary engineering
    • /
    • v.18 no.4
    • /
    • pp.64-69
    • /
    • 2003
  • Recently, Indoor air quality(IAQ) in workplace, residential environments and office has been concern of people, scientists and related the public. The oxygen in air was very important and essential element in every aspect of life. This study was performed on a questionnaire survey of 400 people about their awareness of indoor air quality, oxygen generators and measured of oxygen concentration in indoor environment. The results obtained were as follows; As respondents are having their 90% of daytime indoors a day, and 80% of them can feel indoor air pollutions degrees directly by particle matters. The control of most important problems of IAQ was the poor ventilation. We know that 22% of the respondents was recognized the oxgen generator. And for the installation of indoor pollution control equipment, 20% of all respondents installed oxygen generators because almost respondents was not satified the trust of ability purified indoor air pollutants. In the experimental results, it was found that the oxygen concentration of sampling sites were in the range of 20~23.5%. Therefore, it was recommended that the government related IAQ was suggested the guideline and control of oxygen generators. Finally, it appeared that the oxygen generators using indoor environment can be applied to new technology for cleaning of indoor air.

Evaluating Comfort of Indoor Environment Based on Residents' Responses (신도시 아파트 거주자의 실내환경 쾌적성 평가)

  • 이지숙
    • Journal of the Korean Home Economics Association
    • /
    • v.35 no.5
    • /
    • pp.213-219
    • /
    • 1997
  • The purpose of this study is to propose a model for evaluating comfort of indoor environment based on residents' subjective respones. The questionnaire survey was given to the residents at apartment complex located in Ilsan, Kyunggi-Do. The following are the results obtained in this thesis. The results of path analysis on comfort revealed that direct effects to comfort were the satisfaction on thermal environment, indoor air environment and sound environment, and the cognition on indoor air environment and sound environment. An evaluation formula of comfort by the factors of direct effects was given. This formula is recommended to evaluate comfort for pp.O.E(post occupancy evaluation)by residents.

  • PDF

Development and Evaluation of a PMV Sensor for the Control of Indoor Thermal Environment (실내 온열환경 제어를 위한 PMV 센서의 개발 및 적용성 평가연구)

  • 윤동원;강효석;안병욱
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.10
    • /
    • pp.870-878
    • /
    • 2003
  • The maintenance of thermal equilibrium between the human body and its environment is one of the primary requirements for health, wellbeing and comfort. For the effective control of indoor thermal environment, thermostat or humidistat is used. But, it is not sufficient to control the indoor thermal environment using only one or two parameters as human response for the indoor comfortable environment. So an environmental thermal index is required for the control of indoor thermal environment effectively. In this study, a PMV sensor has been developed which has integrated from various kinds of individual sensors for temperature, humidity, air velocity, radiant temperature. After applying the PMV and PPD equation, it is possible to monitor the indoor thermal environment with the sensor system, which is adopted to the circuit for optimization according to the human response with the metabolic rate and activities. The measurement was carried out to verify the performance of the integrated sensor system in comparison with existing measurement system, the PMV meter. As a result, the possibility of applying the PMV sensor to control the indoor thermal environment simultaneously was examined.

A study on the effect on indoor air quality by ventilation system operation in buses (고속버스 운행시 공조시스템 조건에 따른 객실 내 실내공기질 변화)

  • An, Sun-Min;Lee, Jung-Sub;Shim, In-Keun;Kim, Ho-Hyun
    • Journal of odor and indoor environment
    • /
    • v.17 no.4
    • /
    • pp.346-354
    • /
    • 2018
  • In this study, the condition of the hazardous materials in the bus was monitored according to the ventilation mode of the air conditioning system during bus service. The bus was surveyed using the indoor air quality measurement method of public transportation vehicles within one year of delivery. We evaluate the $CO_2$ and $PM_{10}$, which are the controlled parameters in buses by the Ministry of Environment, and VOCs and HCHO, the non-controlled parameters. The $PM_{10}$ concentration increased due to outdoor air intake; however the $CO_2$ concentration was found to decrease. In addition, the concentration of VOCs and HCHO was found to decrease due to the forced ventilation system and the outdoor air intake. These results show that the concentration of the other materials except $PM_{10}$ can be changed due to the outside air concentration and forced ventilation system. Therefore, through indoor air quality characteristics of the bus according to air condition system are intended to be used as the basis of an operation manual.

Risk Assessment of Volatile Organic Compounds for Vapor Intrusion Pathway Using Various Estimation Methodology of Indoor Air Concentration (다양한 실내 침투 휘발물질 농도 예측 방법을 이용한 토양오염물질의 실내흡입 위해성평가)

  • Jung, Jae-Woong;Nam, Taekwoo;Nam, Kyoungphile
    • Journal of Soil and Groundwater Environment
    • /
    • v.20 no.4
    • /
    • pp.51-65
    • /
    • 2015
  • Indoor inhalation of vapors intruded into buildings is an important exposure pathway in volatile organic compoundscontaminated sites. Site-specifically measured indoor air concentration is preferentially used for risk assessment. However, when indoor air concentration of VOC is not measured, the indoor air concentration needs to be estimated from soil concentration or measured soil gas concentration of the VOC. Some risk assessment guidance (e.g., Korea Ministry of Environment (KMOE) and American Society for Testing and Materials (ASTM) International guidance) estimate the indoor air concentration from soil concentration while other guidances (e.g., United States Environmental Protection Agency (USEPA) and Dutch National Institute for Public Health (RIVM)) estimate it from measured soil gas concentration. This study derived indoor inhalation risks of intruded benzene in two benzene-contaminated residential areas with four different risk assessment guidances (i.e., KMOE, USEPA, ASTM, and Dutch RIVM) and compared the derived risks. The risk assessment results revealed that indoor air estimation approach from soil concentration could either underestimate (when the contaminant is not detected in soil) or overestimate (when the contaminant is detected in soil even at negligible concentration) the indoor air inhalation risk. Hence, this paper recommends to estimate indoor air concentration from soil gas concentration, rather than soil concentration. Discussions about the various indoor air concentration estimation approaches are provided.

Evaluation of Indoor Air Environment by Changing Diffuser Location and Air Temperature with Under Floor Air Conditioning System (바닥취출 및 흡입시스템 공조방식에서 취출조건 변경시 실내공기환경 평가)

  • Kim Se-hwan;Park Jong-Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.5
    • /
    • pp.397-403
    • /
    • 2005
  • The thermal comfort of occupants is directly related to several environmental factors such as velocity of air flow, turbulence intensity and temperature distribution of indoor air. The purpose of this study is to evaluate the indoor air flow and temperature distribution in office area using under-floor air-conditioning system (UFAC System) based on the results from physical measurements and to perform a Computer Fluid Dynamics (CFD) under the same condition of inlet and outlet as field measurement. The results from the CFD simulation are similar to those from the field measurement. The results show that UFAC system is provide proper indoor condition for occupants.

A Study on the Actual Conditions of Indoor Air Quality of Underground Dwellings and the Automatic Ventilating Fan Operated by CO2 Controller and Timer (지하주거의 실내공기환경 실태조사와 CO2 조절기 및 타이머에 의한 환기팬 자동운전에 관한 연구)

  • Kwon, Young Cheol;Park, Jin Chul
    • KIEAE Journal
    • /
    • v.8 no.4
    • /
    • pp.3-9
    • /
    • 2008
  • The rapid urbanization after 1970s caused the shortage of dwellings in urban areas. As the result, the underground dwellings were developed to compensate for the insufficient dwelling spaces. While the underground dwellings have some advantage in the respect of thermal and acoustic environment, they usually have the basic problems in the indoor air quality because of the lack of natural ventilation through small window areas. The purpose of this study is to investigate and to improve the indoor air quality of underground dwellings. Thirty Units in Seoul and Gyung-Gi Province were investigated into the indoor environmental conditions. For the purpose of the improvement of their indoor air quality, Automatically-operated ventilating fan was installed in a sample unit which has worst indoor environmental condition. Then the indoor air quality was monitored when it was operated by $CO_2$ control system and timer. Finally economic feasibility study was made considering the effect of the improvement of indoor air quality. The extra cost for installing timer could be paid back only in 10 months, so timer-installed automatic fan is recommended to improve the indoor air quality of underground dwellings.

The Indoor Thermal and Air Environment of General Apartment Houses during Winter in Cheongju City (청주시 아파트 일반가정의 겨울철 실내열·공기환경 현장측정조사)

  • Cho, Jun Haeng;Choi, Yoon Jung
    • KIEAE Journal
    • /
    • v.13 no.3
    • /
    • pp.111-120
    • /
    • 2013
  • The purposes of this study were to investigate the actual state of the indoor thermal and air environment in general apartment houses during winter in Cheongju City, to analyze the related factors with the indoor thermal and air environment, and to make suggestions for the improvement. A series of visiting field investigation was conducted in twenty units between 28th December, 2010, and 11th March, 2011. The field investigations included the measurement of physical indoor environmental conditions, the observation of architectural characteristics and resident's behavior, and the on-site questionnaire survey of residents. The measured values of each units were compared to evaluation standard and were categorized to group by the difference between units. Factors related to the difference of the measured values between the groups were analyzed. The findings are summarized as followed. The indoor temperature of apartment houses during winter in Cheongju City was generally suitable. The relative humidity was slightly dry, while the $CO_2$ concentration was found to be excessively high. The factors related indoor environment were analysed as heating operation, ventilation, gas range use, and hanging out the wash to dry in indoors.