• 제목/요약/키워드: indoor $PM_{2.5}$

검색결과 268건 처리시간 0.025초

다중이용시설의 위생상태에 관한 조사연구 (A Study on the Sanitation Condition of Public Facility)

  • 김종오;정용택
    • 환경위생공학
    • /
    • 제24권1호
    • /
    • pp.47-55
    • /
    • 2009
  • Indoor air Quality in public facility same as bus terminal and subway station is very important for civil health. The purpose of this study was to investigate the concentration and distribution of PM10 and falling microorganism at the 5 subway stations and bus terminals from Summer 2003 to Summer 2005 in Kyunggi Province. The results were as follows. 1. The highest concentration of PM10 was $187ug/m^3$ at Bucheon Bus Terminal in 2005 while the lowest concentration of PM10 was $78ug/m^3$ at Suwon Bus Terminal in 2003. The year variation of PM10 concentration at the bus terminals in Kyunggi Province was in order of 2005 > 2004 > 2003. The average concentration of PM10 at the five Bus Terminal was $127ug/m^3$. 2. The highest concentration of PM10 was $225ug/m^3$ at Euijungbu Station l in 2004 while the lowest concentration of PM10 was $115ug/m^3$ at Suwon Station in 2003. The year variation of PM10 at the subway stations in Kyunggi Province was in order of 2004 > 2005 > 2003. The average concentration of PM10 at the five subway stations was $164ug/m^3$. 3. The average amount of falling microoganism at the five bus terminal in Kyunggi Provinc was 201CFU/plate. The minimum is 124 CFU/plate at Seongnam Bus Terminal in 2004 while the maximum is 268CFU/plate at Euijungbu Bus Terminal in summer 2005. The higher concentration of PM10 was 206CFU/plate in 2004 than 199CFU/plate in 2003 and 2005. 4. The minimum is 107CFU/plate at Anyang station in 2003 while the maximum was 263CFU/plate at Euijungbu station in 2003. The average amount of falling microoganism at the five subway stations in Kyunggi Province was 179 CFU/plate. The year variation of falling microorganism at the subway stations in Kyunggi Province was in order of 2004 > 2005 > 2003.

다중이용시설 내 식생바이오필터 시스템의 PM10, PM2.5 저감효과 및 측정방법에 대한 연구 (Study on PM10, PM2.5 Reduction Effects and Measurement Method of Vegetation Bio-Filters System in Multi-Use Facility)

  • 김태한;최부헌
    • 한국조경학회지
    • /
    • 제48권5호
    • /
    • pp.80-88
    • /
    • 2020
  • 2019년 3월 미세먼지 비상저감조치가 일주일 동안 발령되면서, 미세먼지로 인한 국민의 불안감은 점차 가중되고 있다. 본 연구는 공기정화식물이 적용된 바이오필터의 다중이용시설 내 적용성 평가를 위해 입자상 오염원의 실내 연속방출환경을 조성하여 오염원 저감효과에 대한 측정방법을 제안하고, 시스템의 실내공기질 개선 여부를 확인할 수 있는 기초연구를 진행하였다. 강의실을 대상으로 춘절기에 모니터링 1시간 전 모기향을 오염원으로 배경농도를 조성한 후, 스케줄에 따라 2시간 관수, 1시간 송풍하여 미세먼지의 저감능을 확인하였으며, 바이오필터 2m 전방에 PM10, PM2.5 및 온습도 센서를 설치하고, 3개 송풍구 중 중앙에 풍속 프로브를 설치하여 시계열 모니터링을 수행하였다. 바이오필터에 구비된 총 3개소의 송풍구 평균 면풍속은 0.38±0.16 m/s로 댐퍼 면적이 제외된 송풍구별 면적 0.29m×0.65m을 적용한 총 공조풍량이 776.89±320.16㎥/h로 산출되었다. 시스템 가동으로 평균온도 21.5~22.3℃, 평균상대습도 63.79~73.6%를 유지하여, 선행연구의 다양한 조건별 온습도 범위에 부합하는 것으로 판단된다. 시스템 공조부 구동을 통해 급격하게 상대습도를 상승시키는 효과를 효율적으로 운용할 경우, 계절에 따른 실내 미세먼지 저감과 적정한 상대습도 확보도 가능할 것으로 판단된다. 미세먼지 농도는 바이오필터 시스템 가동 전의 모든 주기에서 상승 현상이 동일하게 집계되었으며, 시스템 가동 후 1주기 송풍구간(B-1, β=-3.83, β=-2.45)에서 미세먼지(PM10)는 최대 28.8% 수준인 560.3㎍/㎥, 초미세 먼지(PM2.5)는 최대 28.0% 수준인 350.0㎍/㎥까지 저감되었다. 이후 미세먼지(PM10, PM2.5)의 농도는 2주기 송풍구간 감소(B-2, β=-5.50, β=-3.30)로 각각 최대 32.6% 수준인 647.0㎍/㎥, 32.4% 수준인 401.3㎍/㎥까지 저감되었고, 3주기 송풍구간감소(B-3, β=5.48, β=-3.51)로 최대 30.8% 수준인 732.7㎍/㎥, 31.0% 수준인 459.3㎍/㎥까지 저감된 것으로 확인되었다. 본 연구는 식생 바이오필터의 다중이용시설 내 설치와 유관한 관련 표준 및 규정을 참조하여, 객관적인 성능평가환경의 구축 방안을 제시할 수 있었다. 이를 통해 일반 강의실 환경 내에 보다 객관화된 모니터링 인프라를 조성하여, 상대적으로 신뢰성 있는 데이터 확보가 가능했던 것으로 판단된다.

Indoor and Outdoor Air Quality and Its Relation to Allergic Diseases among Children: A Case Study at a Primary School in Korea

  • Kim, Ho-Hyun;Kim, Chang-Soo;Lim, Young-Wook;Suh, Min-A;Shin, Dong-Chun
    • Asian Journal of Atmospheric Environment
    • /
    • 제4권3호
    • /
    • pp.157-165
    • /
    • 2010
  • The purpose of this study is to investigate allergic diseases related to allergy caused by the exposure to indoor and outdoor sources of air pollution in primary schools. The symptoms questionnaire of allergic diseases based on the International Study of Asthma and Allergies in Childhood (ISAAC) was completed by the participants. The past and present status of asthma, allergic rhinitis, eczema, and allergic conjunctivitis were investigated by providing a questionnaire to all the participating children. Questionnaires were sent to a total of 61,350 children from 438 primary schools. A total of 40,522 children responded to the questionnaire, which represents a 66.1% return rate. Volatile Organic Compounds (VOCs), $\underline{A}$ldehydes, and Particulate Matter ($PM_{10}$) were measured and analyzed from October to December of 2006, in 82 primary schools. The final study population comprised 35,168 children with complete data which excluded incomplete questionnaire responded by 5,354 children. Based on the survey, the level of indoor air contamination did not appear to be high, but 27.2% of the schools evaluated had exceeded the $PM_{10}$ level specified by the school health guidelines ($100\;{\mu}g/m^3$). The overall mean concentration of formaldehyde was $22.07\;{\mu}g/m^3$ and 1.0% of schools (1 school) exceeded the $100\;{\mu}g/m^3$. Statistically significant relationships have been observed between indoor air quality and prevalence rate of allergic rhinitis and conjunctivitis of primary schools in Korea.

국내 일부학교 건축물의 실내공기질 평가 (The Assessment of Survey on the Indoor Air Quality at Schools in Korea)

  • 손종렬;노영만;손부순
    • 한국환경보건학회지
    • /
    • 제32권2호
    • /
    • pp.140-148
    • /
    • 2006
  • Recently, indoor air quality (IAQ) in workplace, residential environments and schools has been concerned of people, scientists and related the public, and has recognized the health effects related to indoor air pollution. Therefore, this study was performed to investigate the characteristics of IAQ in 55 kindergartens, elementary school, middle schools, and high schools from June, 2004 to May, 2005 in Korea. We measured indoor air pollutants($PM_{10},\;CO_2$, HCHO, total bacteria colony(TBC), CO, radon, TVOCs, asbestos, and $O_3$), and physical factors(noise, temperature, relative humidity, and illumination) with necessary of management for IAQ in school. We classified into 5 kinds of the school by period since building completion, <1 year, 1-3 years, 3-5 years, and 5-10 years. The concentration of pollutants and the level of physical factors compared with standards and guidelines of IAQ on the Ministry of Environment, the Ministry of Health and Welfare, and the Ministry of Education and Human Resources Development. The major results obtained from this study were as follows. Temperature, relative humidity and illumination among the physical factors did not exceed the standards, but noise exceeded it. Asbestos and $O_3$ did not detect in surveyed classrooms. CO, TBC, TVOCs, and HCHO in kindergartens, TBC in elementary schools, TBC, TVOCs dnd HCHO in middle schools, and HCHO in high schools detected the standards. This study is conducted as a part of efforts to provide a foundational data for further relative researches on management of IAQ of school. Therefore, we suggest that country plan for management of IAQ in school should be established through long-term and continuous investigation for assessment on IAQ in school and health risk assessment for students.

시간활동도를 이용한 이산화질소 개인노출 예측 - 한국의 서울과 호주의 브리스베인의 비교 연구 - (Estimation of Personal Exposure on Nitrogen Dioxide Using Time Activity - Comparative Study between Seoul, Korea and Brisbane, Australia -)

  • 양원호;이기영;손현석;정문호
    • 환경위생공학
    • /
    • 제15권2호
    • /
    • pp.10-17
    • /
    • 2000
  • 현대 생활에서 대부분의 사람들은 90%이상을 실내(가정, 일반사무실, 실내작업장, 공공건물, 지하시설물, 상가, 음식점, 자동차, 지하철 등)에서 생활하기 때문에 실내공기질(indoor air quality)은 개인이 오염물질에 노출되는 주요한 요인이다. 이산화질소($NO_2$)는 고온의 연소과정에서 발생되는 부산물로써 차량, 발전소와 산업장 등에서 발생되고 있다. 실내에서 이산화질소의 농도는 가스레인지, 케로센(kerosene) 난방기, 흡연에 주로 영향을 받는다. $NO_2$는 호흡기 증상과 관련된 각종 질환을 유발시키는 것으로 보고되고 있다. 본 연구는 한국의 서울에서 직장인 95명의 시간활동도가 조사되었으며, 호주 브리스베인에서 직장인 57명의 시간활동도와 동시에 각 가정의 실내.외 및 직장의 $NO_2$ 농도를 측정하였다. 또한 개인 $NO_2$ 노출을 예상하여 각 도시의 빈도분포를 예상하였다. 본 연구의 결과를 보면 다음과 같다. 1. 서울의 95명의 직장인들은 실내에서 약 83.8%의 시간을 보냈으며, 브리스베인의 57명의 직장인들은 실내에서 약 88.3%의 시간을 보냈다. 2. 브리스베인에서 측정된 실내의 NO2 평균농도는 10.5ppb(${\pm}5.6$), 실외의 NO2 평균농도는 14.5ppb(${\pm}5.8$), 직장에서의 $NO_2$ 평균농도는 18.2ppb(${\pm}5.0$)였다. 개인의 $NO_2$ 노출은 평균 15.0ppb(${\pm}5.2$)였다. 개인의 $NO_2$ 노출은 실외의 $NO_2$ 농도(r=0.42)보다 실내의 $NO_2$ 농도(r=0.42)보다 실내의 NO2 농도(r=0.49)에 상관성이 더 높았다. 3. 시간 가중치 모델을 이용한 개인 $NO_2$ 노출은 측정된 개인 NO2 노출과 통계학적으로 상관성을 가지고 있었다(r=0.58). 예측된 개인 $NO_2$ 노출은 측정된 $NO_2$ 노출보다 낮게 나타났으며, 이것은 출퇴근 등에 의한 교통의 이동에 따른 노출 때문인 것으로 생각되었다. 4. $NO_2$ 농도 분포를 log-normal 분포, 시간활동도를 Normal 분포로 가정하고 Monte-Carlo 시뮬레이션을 했을 때 서울의 직장인의 개인 노출은 평균 36.7ppb(${\pm}10.9$)였으며, 브리스베인의 직장인의 개인 노출은 평균 13.7ppb(${\pm}4.1$)였다.

  • PDF

주방 조리시 미세먼지(PM2.5) 배출 특성과 관리방안 (Characteristics and Management of Particulate Matter(PM2.5) Emission on Cooking Condition)

  • 이명구;정명진;강민지
    • 문화기술의 융합
    • /
    • 제4권1호
    • /
    • pp.325-329
    • /
    • 2018
  • 실내 거주공간에는 건축 자재, 환기, 조리 등으로 인하여 많은 오염물질이 발생한다. 이중 미세먼지는 1급 발암물질로 인체에 매우 유해한 물질이며, 주로 조리시에 가장 많이 발생한다. 따라서 실내공기질을 잘 관리하기 위해서는 조리시 발생하는 미세먼지의 농도와 환기방법과의 관계를 평가할 필요가 있다. 이에 본 연구에서는 음식물의 종류 및 환기방법에 따른 미세먼지(PM2.5)의 농도변화를 측정하고 분석하여, 주방 조리시 발생하는 미세먼지의 관리방안을 제시하고자 하였다.

황복, Takifugu obscurus의 초기 발달 동안 성장 및 생존에 있어 먹이와 염분의 효과 (Effect of Food and Salinity on Larval Growth and Survival of the River Puffer, Takifugu obscurus)

  • 강희웅;강덕영;조기채;이진호;박광재;김종화
    • 한국양식학회지
    • /
    • 제17권3호
    • /
    • pp.221-227
    • /
    • 2004
  • 본 연구에서는 황복, T. obscurus의 초기발달동안 자치어의 성장과 생존에 미치는 먹이 종류와 염분별 영향을 조사하였다. 먹이별 실험에서는 Artemia공급 시기인 부화 25일의 자어를 이용해 Artemia (대조구)와 5가지의 먹이 (실지렁이, 물벼룩, 바지락육질, 배합사료, 곤쟁이)를 30일간 혼합 공급하여 실험구별 성장과 생존율을 비교하였다 염분별 실험에서는 일령 15일 자어(전장 5.8$\pm$0.4 mm: Stage I), 일령 36일 치어(전장 12.0$\pm$0.2 mm: Stage II) 및 일령 70일 치어(전장 44.5$\pm$0.7mm: Stage III)를 대상으로 4개의 염분 농도구(0, 10, 20 및 30 psu)를 설정하여 성장과 생존을 비교분석하였다. 먹이실험 결과, 성장도는 배합사료, 실지렁이, 물벼룩 공급구들이 비교적 양호하게 나타났으나, 생존율은 물벼룩 공급구가 가장 높게 나타났으며, 빠른 성장을 보였던 배합사료와 실지렁이 혼합 공급구는 오히려 낮은 생존율을 나타내었다. 염분별 실험에서는 Stage I 경우 성장에 있어 염분별 뚜렷한 차이를 찾아 볼 수 없었으나, 생존율은 10∼20 psu구에서 높게 나타났다. 또한 Stage II의 경우 성장과 생존 모두 10∼20 psu에서 양호하였으며, Stage III에서는 0∼30 psu의 모든 염분 조건에서 정상적인 성장과 생존을 나타내었다.

동갈돗돔, Hapalogenys nitens의 자연산란과 난발생 특성 (Natural Spawning and Characteristics of Egg Development of the Indoor Cultured Grunt, Haphlogenys nitens)

  • 강희웅;김종화;이권혁;김종식
    • 한국양식학회지
    • /
    • 제17권3호
    • /
    • pp.180-186
    • /
    • 2004
  • 본 연구는 동갈돗돔의 대량 인공종묘생산 기술개발을 위한 기초자료를 얻고자 자연산란을 유도하여 산란된 알의 특성을 조사하였다. 실험에 사용된 어미는 3년동안 실내사육한 자연산 7마리로서, 크기는 전장 34.0∼44.0 cm (38.6$\pm$4.0 cm), 체중 1.00∼2.23 kg (1.62$\pm$0.50 kg)이었다. 산란은 2000년도에는 9월 22일부터 10월 1일까지 9일간, 2001년도의 경우, 8월 22일부터 10월 3일까지 37일 동안 이루어졌다. 산란기간 중 수온은 19.8∼28.5$^{\circ}C$범위였다. 알의 ml당 수는 1,700개였고, 2년 간 총 산란량은 22,883,000개로, 이 중 부상률은 41.7% (9,539,000개)였다. 부상란에 대한 수정률은 85.0∼99.9%였으며, 부화율은 2.9∼93.0%였다. 수정란은 분리부성란으로 난경은 0.85∼0.98 mm였으며, 유구는 1∼5개가 존재하였다. 수온 26 $^{\circ}C$ 에서 수정 10분 후에 배반이 형성되었으며, 수정 후 50분에는 16세포기, 3시간 후에는 포배기, 7시간 30달 후에는 배체가 형성되었다. 부화는 수정 20시간 40달 후에 이루어졌으며,부화자어의 크기는 전장 1.81$\pm$0.18 mm이었다. 수온별 부화소요시간은 23$^{\circ}C$에서는 31∼34시간, 29$^{\circ}C$의 경우, 17∼20시간이 소요되었다.

청정환기장치 최적제어를 위한 IoT 기반 실시간 공기질 모니터링 플랫폼 구현 (IoT Based Real-Time Indoor Air Quality Monitoring Platform for a Ventilation System)

  • 수던 프라사드 우프레티;김유신
    • 인터넷정보학회논문지
    • /
    • 제21권6호
    • /
    • pp.95-104
    • /
    • 2020
  • 본 연구는 사물인터넷(IoT) 센서를 이용해 실내공기질에 주요한 영향을 미치는 미세먼지, 초미세먼지, 이산화탄소, 유기화학물과 온도, 습도 데이터를 실시간으로 수집/분석할 수 있는 실시간 실내공기질 모니터링 서비스를 클라우드 플랫폼으로 구현하였다. 이를 실내공기 정화시설인 청정환기장치와 연동하여 실시간 실내공기질 상태에 따라 환기장치 최적관리할 수 있도록 하였다. 본 플랫폼은 청정환기장치 내외부에 장착된 실내공기질 측정 센서로부터 실시간으로 데이터를 수집하는 IoT 데이터 수집부, 수집된 데이터를 클라우드 환경에서 가공/처리/적재하는 클라우드 데이터 처리부, 적재된 빅데이터를 분석하고 공기질 현황을 웹과 모바일에 시각화하여 보여주는 데이터 분석 서비스부로 구성된다. 그리고 이러한 플랫폼의 가동과 효과를 검증하기 위해 공기질에 민감한 영유아의 교육 생활환경인 국공립 어린이집 교실을 대상으로 실증을 실시하였다. 모든 분석 결과는 웹과 모바일에서 실시간으로 시각화 서비스될 수 있도록 실증 구현하였고, 환기장치의 실내공기질 개선효과는 실내공기질 측정 센서들의 측정값을 통계적으로 검증하여 공기질 개선에 기여하고 있음을 확인하였다.

스킨답서스에 LED와 Fan을 이용한 실내공기정화 시스템 (The Indoor Air Purification System Using LED and Fan for Epipremnum aureum)

  • 김태현;박준모;김수찬
    • 융합신호처리학회논문지
    • /
    • 제19권4호
    • /
    • pp.167-173
    • /
    • 2018
  • 빛이 부족하고 공기 순환이 원활하지 않은 실내에서 식물의 지상부와 지하부를 활용한 공기 정화 시스템을 제안한다. 제안된 시스템은 식물의 공기정화 효과를 극대화하고자 지상부는 청색과 녹색의 LED를 조합한 혼합광과 자연광에 가까운 고연색 LED를 각각 조사하고 지하부의 토양을 필터로 활용하고자 팬을 이용하여 강제 순환하였다. 광원과 팬이 결합된 실내공기정화 시스템이 식물만 배치된 경우보다 오염된 공기를 단시간에 가장 많이 제거하였다. 실내 공기정화 시스템의 혼합광과 고연색광 두 가지의 경우에서 식물만 배치된 경우보다 미세먼지는 각각 14%, 14.2%, TVOC는 7.5%, 9.4% 로 더 크게 감소하였다. 팬을 15분 동안만 가동한 실험에서도 TVOC가 97.8%로 크게 감소하였다. 식물의 광합성과 토양을 필터로 활용하는 것이 오염된 공기를 짧은 시간에 정화시킬 수 있었고 팬의 일시적인 가동으로도 지속적인 가동의 효과를 얻었다.