• 제목/요약/키워드: indirect heating system

검색결과 36건 처리시간 0.034초

리튬이온 배터리 방전 시 발열 특성 및 냉각 실험과 유한요소 해석 (Thermal Characteristics and Cooling Experiments and Analysis of Finite Elements in the Discharge of Lithium-Ion Batteries)

  • 김석일;강신유
    • 산업기술연구
    • /
    • 제43권1호
    • /
    • pp.15-23
    • /
    • 2023
  • Lithium-ion batteries are predominantly employed in electric vehicles and energy storage devices, offering the advantage of high energy density. However, they are susceptible to efficiency degradation when operated at high temperatures due to their sensitivity to the external environment. In this study, we conducted experiments using an indirect cooling method to prevent thermal runaway and explosions in lithium-ion batteries. The results were validated by comparing them with heat transfer simulations conducted through a commercial finite element analysis program. The experiments included single-cell exothermic tests and cooling experiments on a battery pack with 10 cells connected in series, utilizing 21700 lithium-ion batteries. To block external temperature influences, the experimental environment featured an extrusion method insulation in the environmental chamber. The cooling system, suitable for indirect cooling, was constructed with copper tubes and pins. The heat transfer analysis began by presenting a single-cell heating model using commercial software, which was then employed to analyze the heating and cooling of the battery pack.

간접열탈착방식을 이용한 원유오염토양 정화효율 평가 (The Study of Crude Oil Contaminated Soil Remediation by Indirect Thermal Desorption)

  • 이인;김종성;정태양;오승택;김국진
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제21권3호
    • /
    • pp.14-20
    • /
    • 2016
  • Remediation of crude oil contaminated soil is complicate and hard to apply traditional methods because of its persistency, durability, and high viscosity. Therefore, in this study, the efficiency of crude oil contaminated soil remediation was tested by developing a pilot-scale thermal desorption system using the indirect heating method with an exhaust gas treatment. Under optimal condition drawed by temperature and retention time, the remedial efficiency of crude oil contaminated soil and treatability of exhaust gas were analyzed. Total Petroleum Hydrocarbon (TPH) concentration of crude oil contaminated soil was decreased to 69.7 mg/kg on average and the remedial efficiency was measured at 99.60%. Through the exhaust gas, 86.0% of Volatile Organic Compounds (VOC) was degraded and 97.16% of complex malodor was reduced under the suggested optimum operation condition. This study provides important basic data to be useful in scaling up of the indirect thermal desorption system for the remediation of crude oil contaminated soil.

An Experimental Study on the Performance of Air/Water Direct Contact Air Conditioning System

  • Yoo, Seong-Yeon;Kwon, Hwa-Kil
    • Journal of Mechanical Science and Technology
    • /
    • 제18권6호
    • /
    • pp.1002-1009
    • /
    • 2004
  • Direct contact air conditioning systems, in which heat and mass are transferred directly between air and water droplets, have many advantages over conventional indirect contact systems. The purpose of this research is to investigate the cooling and heating performances of direct contact air conditioning system for various inlet parameters such as air velocity, air temperature, water flow rate and water temperature. The experimental apparatus comprises a wind tunnel, water spray system, scrubber, demister, heater, refrigerator, flow and temperature controller, and data acquisition system. The inlet and outlet conditions of air and water are measured when the air contacts directly with water droplets as a counter flow in the spray section of the wind tunnel, and the heat and mass transfer rates between air and water are calculated. The droplet size of the water sprays is also measured using a Malvern Particle Analyzer. In the cooling conditions, the outlet air temperature and humidity ratio decrease as the water flow rate increases and as the water temperature, air velocity and temperature decrease. On the contrary, the outlet air temperature and humidity ratio increase in the heating conditions as the water flow rate and temperature increase and as the air velocity decreases.

감압 튜브 및 팽창헤더를 이용한 직접식 태양열 온수기의 설계 및 제작에 관한 연구 (Design and Manufacture of Direct Solar Hot Water Heating System Using Pressure Relief Tube and Expandable Header)

  • 천원기;김형택
    • 태양에너지
    • /
    • 제20권3호
    • /
    • pp.51-60
    • /
    • 2000
  • This paper deals with the design, construction and operation of a direct solar hot water heating system developed to harness the solar energy more effectively. The system introduced here uses a unique network of riser tubes and header pipes apart from the existing concept to exploit the physical properties of water which expands when it freezes. It also employs a special pressure relief mechanism for the header to prevent its breakage due to freezing. A number of tests are made to assure its functional reliability during frigid weather conditions and its superior performance over indirect systems.

  • PDF

간접유도가열용 고주파 공진형 인버터 시스템에 관한 연구 (A Study on the High-Frequency Resonant Inverter System for Indirect Induction Heating)

  • 권혁민;신대철;김기환;김용주
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 전력전자학술대회 논문집
    • /
    • pp.322-325
    • /
    • 2002
  • In this paper are described the indirect induction heated boiler and induction heated hot air producer using the voltage-fed series resonant high-frequency inverter which can operate in the frequency range from 20kHz to 50kHz. A specially designed induction heater, which is composed of laminated stainless assembly with many tiny holes and interconnected spot welding points between stainless plates, is inserted Into the ceramic type vessel with external working coil. This working coil is connected to the inverter and turbulence fluid through this induction heater to moving fluid generates in the vessel. The operating performances of this unique appliance in next generation and its effectiveness are evaluated and discussed from a practical point of view.

  • PDF

전압형 고주파 인버터를 이용한 간접유도가열 열유체 에너지시스템과 그 성능평가 (Electromagnetic Indirect Induction Fluid Heating System using High-Frequency Inverter and Its Performance Evaluations)

  • 김용주;신대철;김기환
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.483-486
    • /
    • 2001
  • This Paper the state-of-the art indirect induction heated boiler and induction heated hot air producer using the voltage-fed series resonant high-frequency inverter whice can operate in the frequency range from 20kHz to 50kHz. A specially-designed induction heater composed of laminated stainless assembly with many tiny holes and interconnected spot welding points between stainless plates is inserted into the ceramic type vessel with external working coil connected to the inverter and tubelence fluid through this induction heater in moving fluid generates in the vessel. The operating performances of this unique appliance in next generation and its effectiveness are evaluated and discussed from a practical point of view.

  • PDF

개방형 지열 히트펌프 시스템의 운전 특성 (Operation Characteristics of Open Type Geothermal Heat Pump)

  • 임효재;공형진;송윤석;박성구
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.701-706
    • /
    • 2006
  • Groundwater heat pump systems are the oldest of the ground-souce systems and it has various type. Standing column well type are must be located in hard rock geology site and produce sufficient water for the conventional open loop system. These system are indirect type(the building circulating loop and ground water are intercept). Existence of the exchanger the foundation protect water quality to use of open loop. The design of open loop system are concern on the power requirements. An experimental study was analysis the extremely heating operation COP of ground water heat pump system. Operation efficiency of the 50RT systems shows that, COP $2.9{\sim}5.0$ in heating operation. And generally it shows 3.4.

  • PDF

Developing Polyclonal Antibody-based Indirect-ELISA to Detect Anthracnose Inocula Prior to Soybean Sprout Rot

  • Park, Soo-Bong;Lim, Young-Ji;Lee, Jung-Han;Han, Ki-Soo;Lee, Sun-Cheol;Shim, Chang-Ki;Kang, Jin-Ho;Bae, Dong-Won;Kim, Dong-Kil;Kim, Hee-Kyu
    • The Plant Pathology Journal
    • /
    • 제20권4호
    • /
    • pp.252-257
    • /
    • 2004
  • We developed a polyclonal antibody based-ELISA system to monitor inocula accurately and rapidly before onset of anthracnose on soybean sprouts. Titer of mouse antisera against conidia of Colletotrichum gloeosporioides, determined by indirect ELISA, was high enough to be detectable up to ${\times}$25,600 dilutions. Both PAb1 and PAb2 had the highest level of reactivity to Colletotrichum gloeosporioides. Absorbance readings exceeded 0.15. Sensitivity of PAb to C. gloeosporioides was precise enough to detect spore concentration as low as 500 conidia/well by indirect ELISA. Both antibodies are very sensitive and highly specific to the target pathogen Colletotrichum gloeosporioides, apparently discriminating other unrelated pathogen, or epiphytes. This kit fulfills the requirements far detecting inocula before infection and onset of anthracnose. Our ELISA system should also be feasible to detect C. acutatum (Mungbean sprouts rot) and G. cingulata (C. gleosporioides), (apple, pepper). It was remarkable that absorbance value was not reduced even after 4 consecutive washings (Fig.4), suggesting that antigenic determinants are on the surface of conidia. Antigenic determinant was characterized by heating and enzyme treatment: Both PAb1 and PAb2 bind to protein epitope that does not contain residue of amino acid, arginine, and Iysine, even though more work needs to be done.

에너지, 환경 및 경제성을 통합 고려한 공동주택 설계요소 제어에 관한 연구 (A Study on the Control of Apartment House Design Factors considering Energy, Environment and Economical Efficiency)

  • 최두성;도진석
    • KIEAE Journal
    • /
    • 제12권6호
    • /
    • pp.29-38
    • /
    • 2012
  • The current building energy efficiency rating certification regulation on apartment houses evaluates only the saving rate of energy consumed during operation, i.e. use, of a building, but doesn't consider the energy consumptions and environmental load($CO_2$) emissions occurring during the whole lifetime of a building. So this study calculated the energy consumptions and environmental load emissions occurring during the whole lifetime of a building, selected reference schemes and alternative items by design variables to present a design draft considering energy efficiency and environmental performance, and evaluated the total cost by combining and calculating its direct cost(material and heating cost) and indirect cost(environmental cost), for an existing apartment house as an evaluation object. As a result of analysis, the change of heating cost by alternative items of design variables showed a 4~8% change rate compared to the reference scheme, and the material cost of design variable 7 showed a maximum 4.4 times change rate in the alternative plan 6 compared to the reference scheme. The environmental cost showed a similar change rate to the material cost change rate in general, but showed a similar environmental cost change rate to the heating cost change rate in case of design variables 4-1, 4-2, 7.

유도가열용 고주파 공진형 인버터를 이용한 과열증기 발생장치 개발에 관한 연구 (A Study on the Development of Superheater Using High-Frequency Resonant Inverter for Induction Heating)

  • 신대철;권혁민;김기환;김용주
    • 전력전자학회논문지
    • /
    • 제9권2호
    • /
    • pp.119-125
    • /
    • 2004
  • 본 논문에서는 간접 유도가열 되는 보일러 시스템과 주파수 범위가 20〔KHz〕에서 50〔KHz〕사이에서 작동되는 전압형 직렬공진 고주파인버터를 이용하여 열 기체를 발생시키는 전압형 공진형 인버터에 관하여 설명하였다. 얇은 스텐레스 판재가 서로 스폿 용접되어 연결되어있고 기포성 적층형 충진발열체로 특수하게 설계된 유도 가열기는 외부에 워크 코일로 감겨져 있는 불소수지계의 절연용기 안에 삽입되어있다. 이 워크 코일은 공진형인버터와 연결되어 있으며 유도가열기를 통해 흐르는 관 유체를 1단가열부에서 저압의 포화증기를 2단가열부에서 열방사성 증발유체를 생성하는 본 시스템의 성능 및 효용성을 실용적인 측면에서 논의하고 평가한다.