• Title/Summary/Keyword: indirect comparison

Search Result 362, Processing Time 0.043 seconds

A Comparison Study on the Separation Process of TaCl5 from the Chlorinated Reaction Product (염화반응법으로 제조된 TaCl5의 분리공정에 관한 비교 연구)

  • Cho, Jung-Ho;Park, So-Jin;Choi, Young-Yoon
    • Korean Chemical Engineering Research
    • /
    • v.44 no.3
    • /
    • pp.259-264
    • /
    • 2006
  • The separation and purification of $TaCl_5$is indispensable in the synthetic process of $TaCl_5$by chlorination of tantalum oxide. The reaction products are mainly $TaCl_5$, $NbCl_5$, $TiCl_4$ and $FeCl_2$. However, we need to separate $TaCl_5/NbCl_5$ mixture from the reaction product, because $TaCl_5$ and $NbCl_5$ are easily separated each other by distillation or hydrogen reduction process. In this work, a comparison study was carried out between direct sequence and indirect sequence to obtain $TaCl_5/NbCl_5$ mixture from the reaction product by removing light component, $TiCl_4$ and heavy component, $FeCl_2$ using two distillation columns. It was concluded that the direct sequence gave better results than indirect sequence in the aspect of initial capital costs and the associative operating costs.

An Experimental Study on the Performance of a Cross-Flow-Type, Indirect Evaporative Cooler Made of Paper/Plastic Film (종이와 플라스틱 필름의 이종 재질로 구성된 직교류형 간접증발소자의 성능에 대한 실험적 연구)

  • Kwon, Mi-Hye;Go, Min-Geon;Kim, Nae-Hyun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.9
    • /
    • pp.475-483
    • /
    • 2015
  • In Korea, a typically hot and humid summer means that air-conditioners consume a large quantity of electricity; accordingly, the simultaneous usage of an indirect evaporative cooler may reduce the sensible-heat level and save the amount of electricity that is consumed. In this study, the heat-transfer and pressure-drop characteristics of an indirect evaporative cooler made of paper/plastic film were investigated under both dry and wet conditions; for the purpose of comparison, an indirect evaporative cooler made of plastic film was also tested. Our results show that the indirect evaporative efficiencies under a wet condition are greater than those under a dry condition, and the efficiencies of the paper/plastic sample (109% to 138%) are greater than those (67% to 89%) of the plastic sample; in addition, the wet-surface, indirect evaporative efficiencies of the paper/plastic sample are 32% to 36% greater than those of the plastic sample. Further, the wet-surface pressure drops of the paper/plastic sample are 13% to 23% larger than those of the plastic sample, and this might have been caused by the surface roughness of the samples. A rigorous heat-transfer analysis revealed that, for the plastic sample, 30% to 37% of the wet channels remained dry, whereas all of the channels were wet for the paper/plastic sample.

Detection of antibodies against infectious Borna disease virus -a comparison of three serological methods- (보르나병 바이러스 항체검출을 위한 연구 -세 가지 혈청진단법의 비교-)

  • Lee, Du-sik
    • Korean Journal of Veterinary Research
    • /
    • v.32 no.1
    • /
    • pp.57-61
    • /
    • 1992
  • To determin the accuracy of serological methods in detecting Borna-disease(BD) viral antibodies, 273 experimentally infected rabbit sera were compared by using indirect immunofluorescence antibody test(IFA), serum neutralization test(SN) and enzyme-linked immunosorbent assay(ELISA). One hundred twenty-three serum samples had BD viral antibodies detected by IFA. CELISA antibodies to BD virus were also present in the same one hundred twenty-three serum samples. However, neutralization test antibodies to BD virus were present in 27 of the in rabbit serum samples. Neutralization test was sensitive in comparison with KFA and CELISA. In comparison with IFA, CELISA was both sensitive and specific in detecting BD viral antibodies. These results extend observations made with laboratory animals to the diagnosis of naturally infected animals.

  • PDF

Analysis of Line of Sight Stabilization Performance based on Direct vs. Indirect of a 2-axis Gimbaled Servo System for Millimeter Wave Seeker (밀리미터파 탐색기 2축 직구동 김발 서보 시스템의 직접 및 간접 시선안정화 성능 분석)

  • Shin, Seungchul;Lee, Sung-Yong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.11
    • /
    • pp.1555-1561
    • /
    • 2018
  • Tracking and detecting targets by the millimeter wave seeker is affected by movement of platform. Stabilization equipments use an inertial sensor to compensate for disturbance of stabilizing gimbal or platform. In the direct line of sight stabilization system, an inertial sensor is mounted on inner gimbal to compensate the disturbance directly, so the performance is excellent and the implementation method is simple. However gimbal design requires somewhat larger volume. Since an inertial sensor is mounted on gimbal base in the indirect line of sight stabilization system, additional space of gimbal is not required for the gimbal design. However, this method does not directly compensate for the disturbance of the line of sight stabilization axis, which can degrade performance. In order to perform the tracking performance, two methods are analyzed for line of sight stabilization performance based on direct and indirect of a 2-axis gimbaled servo system for millimeter wave seeker in this study. The simulation and experimental results validate the performance comparison of two methods.

Comparison between Isokinetic Peak Torque and Isotonic 1RM on the Knee Joint

  • Jaehyun Yoo
    • Physical Therapy Rehabilitation Science
    • /
    • v.12 no.2
    • /
    • pp.201-205
    • /
    • 2023
  • Objective: Resistance exercise is a necessary element to improve quality of life, and measurement and evaluation of muscle strength provide important information for prescription and management of rehabilitation and exercise programs. This study analyzed the correlation between direct and indirect 1RM for isokinetic maximum torque of the knee joint in order to provide useful information in the field of exercise programs. In addition, the flexion-extension ratio and the difference in left-right deviation were verified. Design: A cross-sectional study Methods: The subjects of this study were 33 healthy adult men and women without medical problems who participated in the health exercise class program at S University in Seoul. The correlation between isokinetic maximum torque and direct and indirect 1RM was analyzed, and a dependent t-test was performed to analyze the flexion-extension ratio and left-right deviation. Results: There was a high correlation between the isokinetic maximum torque and direct and indirect 1RM, and no statistically significant difference was shown between the test methods in the analysis of the flexion-extension ratio and left-right deviation. Conclusions: Isokinetic muscle function measuring equipment is expensive, so it is difficult to use it in local exercise rehabilitation and training sites. Through this study, it was found that direct and indirect 1RM isokinetic maximum torque showed a high correlation, and there was no difference in evaluating muscle function such as flexion-extension ratio and left-right deviation. Therefore, it is considered that the muscle function evaluation using 1RM in general field can be usefully utilized.

A Study on Intrinsic Noise of Capacitively Coupled Active Electrode (용량성 결합 능동 전극의 내부 잡음 분석)

  • Lim, Yong-Gyu
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.13 no.1
    • /
    • pp.44-49
    • /
    • 2012
  • The indirect-contact ECG measurement is a newly developed method for unconstrained and nonconscious measurement in daily Life. This study is the first step to reducing the large background noise appearing in indirect-contact ECG. This study built the thermal noise model of capacitively coupled active electrode which is used in indirect-contact ECG. The results show that the level of thermal noise estimated by the thermal noise model is much the same as that of actual background noise for the capacitively coupled active electrode alone. By applying the actual electrical properties of a sample cotton cloth to the thermal noise model, the theoretical level of thermal noise in the indirect-contact ECG was estimated. The results also show that the level of op-amp's intrinsic noise is so small that it can be negligible in comparison with thermal noise of resistors. The relationship between the level of thermal noise and the resistance of the bias resistor was derived, and it is the base for the further study how to choice the optimal resistance for the bias resistor.

Effects of Self-Esteem, Physical Appearance Comparison, and Media Concern on Sociocultural Attitude toward Appearance, Body Attitudes, and Life Satisfaction (자아존중감, 외모 비교, 미디어 관심이 외모의 사회문화적 태도, 신체 태도 및 삶의 만족에 미치는 영향)

  • Lee, Ji Young;Park, Hye-Jung
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.15 no.3
    • /
    • pp.1-17
    • /
    • 2013
  • The purpose of this study was to identify the relationships among self-esteem, physical appearance comparison, media concern, sociocultural attitude toward appearance, body attitudes, and life satisfaction. Data were collected from a convenience sample of 232 female undergraduate students. Data were analyzed using factor analysis, correlation, and multiple regression. The result showed that there was a correlation between physical appearance comparison and media concern. Self-esteem, physical appearance comparison, and media concern had an indirect influence on body attitudes through sociocultural attitude toward appearance. Self-esteem and physical appearance comparison had a direct effect on body attitude. All variables did not have an influence on life satisfaction, except self-esteem.

  • PDF

Comparison of Complications in Direct and Indirect Osseointegration of Prosthetic Auricular Reconstruction (인조귀 부착술에서 직접 및 간접골통합법의 합병증에 대한 비교)

  • Park, Mu Shik;Han, Ki Hwan;Kim, Jun Hyung
    • Archives of Plastic Surgery
    • /
    • v.32 no.3
    • /
    • pp.293-298
    • /
    • 2005
  • Osseointegrated prosthetic auricular reconstruction can be classified as either direct or indirect. In the $Br{\aa}nemark $ system of direct osseointegration, implants are placed into the mastoid process of the temporal bone. In the Epitec system of indirect osseointegration, implants are inserted into a three-dimensional carrier plate that is fixed to the mastoid by means of screws. We experienced forty-four cases using the indirect system and seventeen cases using the direct system. We compared with two systems by complications, such as skin reaction, implant loosening, implant loss. There were no specific differences in the skin reaction around the implants and abutments in relation to age or system used. The degree of skin reaction was different according to the conditions around the implant: in cases of virgin microtia, a skin flap was used to cover the implant, in contrast to grafted skin coverage for failed autogenous reconstruction. In both systems, the skin reaction was more severe and frequent in skin flap than in grafted skin. Loosening of the implant was more frequent in the direct system; however, accidental detachment of the implant from the abutment was more frequent in the indirect system. To reduce complications of skin reaction in osseointegrated prosthetic auricular reconstruction, it is important for soft tissue around implant to immobilize. Therefore, grafted skin is better than skin flap as soft tissue around implant. And immobilization of soft tissue around implant by wound dressing is major facter.