Browse > Article
http://dx.doi.org/10.6110/KJACR.2015.27.9.475

An Experimental Study on the Performance of a Cross-Flow-Type, Indirect Evaporative Cooler Made of Paper/Plastic Film  

Kwon, Mi-Hye (Division of Mechanical System Engineering, Incheon National University)
Go, Min-Geon (Division of Mechanical System Engineering, Incheon National University)
Kim, Nae-Hyun (Division of Mechanical System Engineering, Incheon National University)
Publication Information
Korean Journal of Air-Conditioning and Refrigeration Engineering / v.27, no.9, 2015 , pp. 475-483 More about this Journal
Abstract
In Korea, a typically hot and humid summer means that air-conditioners consume a large quantity of electricity; accordingly, the simultaneous usage of an indirect evaporative cooler may reduce the sensible-heat level and save the amount of electricity that is consumed. In this study, the heat-transfer and pressure-drop characteristics of an indirect evaporative cooler made of paper/plastic film were investigated under both dry and wet conditions; for the purpose of comparison, an indirect evaporative cooler made of plastic film was also tested. Our results show that the indirect evaporative efficiencies under a wet condition are greater than those under a dry condition, and the efficiencies of the paper/plastic sample (109% to 138%) are greater than those (67% to 89%) of the plastic sample; in addition, the wet-surface, indirect evaporative efficiencies of the paper/plastic sample are 32% to 36% greater than those of the plastic sample. Further, the wet-surface pressure drops of the paper/plastic sample are 13% to 23% larger than those of the plastic sample, and this might have been caused by the surface roughness of the samples. A rigorous heat-transfer analysis revealed that, for the plastic sample, 30% to 37% of the wet channels remained dry, whereas all of the channels were wet for the paper/plastic sample.
Keywords
Indirect Evaporative Cooler; Paper; Plastic; Performance;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Duan, Z., Zhan, C., Zhang, X., Mustafa, M., Zhao, X., Alimohammadisgvand, B., and Hasan, A., 2012, Indirect evaporative cooling : past, present and future potentials, Renew. Sustain. Energy Rev., Vol. 16, pp. 6823-6850.   DOI
2 Jaber, S. and Ajib, S., 2011, Evaporative cooling as an efficient system in Mediterranean region, Appl. Therm. Eng., Vol. 31, pp. 2590-2596.   DOI
3 Caliskan, H., Dincer, I., and Hepbasil, A., 2012, Exergoeconomic enviroecomomic and sustainability analyses of a novel air cooler, Energy Build., Vol. 55, pp. 747-756.   DOI
4 Costello, B. and Finn, D., 2007, Thermal effectiveness characteristics of low approach indirect evaporative cooling systems in buildings, Energy Build., Vol. 39, pp. 1235-1243.   DOI
5 Maheshwari, G. P., Al-Ragom, F., and Suri, R. K., 2001, Energy saving potential of an indirect evaporative cooler, Appl. Energy, Vol. 69, pp. 69-76.   DOI
6 Santamouris, M. and Kolokotsa, D., 2013, Passive cooling dissipation techniques for buildings and other structures : the state of the art, Energy Build., Vol. 57, pp. 74-94.   DOI
7 Watt, J. D. and Brown, W. K., 1997, Evaporative Air Conditioning Handbook, 3rd ed., The Fairmont Press Inc.
8 Pescod, D., 1979, A heat exchanger for energy saving in an air conditioning plant, ASHRAE Trans., Vol. 85, No. 2, pp. 238-251.
9 Maclaine-Cross, I. L. and Banks, P. J., 1981, A general theory of wet surface heat exchangers and its application to regenerative cooling, J. Heat Transfer, Vol. 103, pp. 578-585.
10 Kettleborough, C. F. and Hsieh, C. S., 1983, The thermal performance of the wet surface plastic plate heat exchanger used in an indirect evaporative cooler, J. Heat Transfer, Vol. 105, pp. 366-373.   DOI
11 Parker, R. O. and Treybal, R. E., 1962, The heat mass transfer characteristics of evaporative coolers, Chem. Eng. Prog. Symp. Ser., Vol. 57, No. 32, pp. 138-149.
12 Hasan, A. an Siren, K., 2003, Performance investigation of plain and finned tube evaporatively cooled heat exchangers, Appl. Therm. Eng., Vol. 23, No. 3, pp. 325-340.   DOI
13 Zalewski, W. and Gryglaszewski, P. A., 1977, Mathematical model of heat and mass transfer processes in evaporative coolers, Chem. Eng. Process, Vol. 36, No. 4, pp. 271-280.   DOI
14 Riangvilaikul, B. and Kumar, S., 2010, An experimental study of a novel dew point evaporative cooling system, Energy Build., Vol. 42, pp. 637-644.   DOI
15 Ren, C. and Yang, H., 2006, An analytical model for the heat and mass transfer processes in indirect evaporative cooling with parallel/counter flow configurations, Int. J. Heat Mass Transfer, Vol. 49, pp. 617-627.   DOI
16 Hasan, A., 2012, Going below the wet-bulb temperature by indirect evaporative cooling : Analysis using a modified ${\epsilon}$-NTU method, Appl. Energy, Vol. 89, pp. 237-245.   DOI
17 Cui, X., Chua, K. J., Islam, M. R., and Yang, W. M., 2104, Fundamental formulation of a modified LMTD method to study indirect evaporative heat exchangers, Energy Conservation Management, Vol. 88, pp. 372-381.   DOI
18 Zhao, X., Liu, S., and Riffat, S. B., 2008, Comparative study of heat and mass exchanging materials for indirect evaporative cooling systems, Build. Environ., Vol. 43, No. 11, pp. 1902-1911.   DOI
19 ASHRAE Standard 41.1, 1986, Standard Method for Temperature Measurement, ASHRAE.
20 ASHRAE Standard 41.2, 1987, Standard Method for Laboratory Air-Flow Measurement, ASHRAE.
21 KS-C-9306, 2010, Air Conditioner, Korean Standard Association.
22 Threlkeld, J. L., 1970, Thermal Environmental Engineering, 2nd ed., Prentice Hall Pub.
23 Wang, C.-C., Webb, R. L., and Chi, K.-Y., 2000, Data reduction for airside performance of fin-and-tube heat exchangers, Exp. Thermal Fluid Science, Vol. 21, pp. 218-226.   DOI
24 ASHRAE Standard 143, 2007, Method of test for rating indirect evaporative coolers, ASHRAE.
25 Eckels, P. W. and Rabas, T. J., 1987, Dehumidification : on the correlation of wet and dry transport process in plate finned-tube heat exchangers, J. Heat Transfer, Vol. 109, pp. 575-582.   DOI
26 Klein S. J. and McClintock, F. A., 1953, The description of uncertainties in a single sample experiments, Mech. Eng. Vol. 75, pp. 3-9.
27 Shah, R. K. and London, A. L., 1989, Laminar Flow in Ducts, Academic Press.
28 Wang, C.-C., Hsieh, Y.-C. and Lin, Y.-T., 1997, Performance of plate finned tube heat exchangers under dehumidifying conditions, J. Heat Transfer, Vol. 119, pp. 109-117.   DOI
29 Idem, S. A., Jacobi, A. M. and Goldschmidt, V. W., 1990, Heat transfer characterization of a finned-tube heat exchanger (with and without condensation), Journal of Heat Transfer, Vol. 112, pp. 64-70.   DOI
30 Kim, N.-H., 2015, Modeling of heat and moisture transfer in an indirect evaporative cooler made of plastic film/paper, submitted to Int. J. Air-Cond. Refrig.