• Title/Summary/Keyword: indirect

Search Result 6,760, Processing Time 0.039 seconds

A Study of Comparing Thermal Stimulation between Commercial Indirect Moxibustion and Traditional Indirect Moxibustion (격물구와 상용 간접구의 온열자극 비교 연구)

  • Jang, Min-Ki;Kim, Eun-Jung;Jung, Chan-Yung;Yoon, Eun-Hye;Hwang, Ji-Hoo;Kim, Kap-Sung;Choi, In-Hwa;Lee, Seung-Deok
    • Journal of Acupuncture Research
    • /
    • v.27 no.3
    • /
    • pp.35-45
    • /
    • 2010
  • Backgrounds : Recently, commercial indirect moxibustion has been widely used as a substitute for traditional indirect moxibustion by clinicians due to its convenience in using. But, there has been lack of studies about the similarity of thermal stimulation between commercial indirect moxibustion and traditional indirect moxibustion. Objectives : To demonstrate commercial indirect moxibustion can substitute for traditional indirect moxibustion by comparing thermal stimulation between the two. Methods : We measured bottom temperature of commercial indirect moxibustion and traditional indirect moxibustion with various thicknesses of ginger and garlic. A clinical trial was performed on 18 healthy subjects to evaluate thermal stimualtion. The subjects were randomly assigned into two groups, traditional indirect moxibustion with ginger and garlic. The skin temperature and heating time were measured. They received moxibustion therapy with commercial indirect moxibustion and traditional indirect moxibustion according to their groups. Acupoint Chogcoe($LU_6$), Zusanli($ST_{36}$) and Tianshu($ST_{25}$) were used in each group for 3 times. Results : There was no difference in bottom temperature among commercial indirect moxibustion, traditional indirect moxibustion with 2mm ginger and 3mm garlic. No major difference was detected in the subjects' baseline data. There was no difference in skin temperature and heating time among these 3 type of moxibustions. Also, No major difference was detected in VAS score of thermal stimulation and frequency of burns among these 3 type of moxibustions. But, most subjects regarded their sensation weren't identical because of its own distinct characteristics. Conclusions : Commercial indirect moxibustion, traditional indirect moxibustion with 2mm ginger and 3mm garlic have same thermal stimulation. Thus, commercial indirect moxibustion can substitute for traditional indirect moxibustion.

Determinants of the Indirect Cost Rates of the Government-Funded Research Institutes in Korea (정부출연연구소의 간접비율 결정요인에 관한 연구)

  • 조성표;권선국;박구선;김재식
    • Journal of Technology Innovation
    • /
    • v.5 no.2
    • /
    • pp.155-177
    • /
    • 1997
  • Since 1995 the Korean Ministry of Science and Technology has introduced and implemented a project based system (PBS) for awarding R&D funds. While capital investments for national laboratories such as buildings and research facilities are supported by the government, normal operating expenses including personnel expenses should be earned by national laboratories through open competition under PBS. The project budget includes both direct research costs and indirect costs. The purpose of this paper is to examine the components of indirect costs and to examine determinants of indirect costs of national laboratories in Korea. The indirect costs of nineteen national laboratories are examined. The direct personnel costs and indirect personnel costs out of total personnel costs are 72% and 28%, respectively. The average indirect cost rate is 74.1% of direct personnel costs. Major components of indirect costs are general operating costs, indirect personnel costs, taxes and dues, and expenses related to the usage of equipment. The significant determinants of indirect cost are indirect personnel ratio. the ratio of unique projects, the type of national laboratories (pure research laboratories or other), and asset activity ratio measured as research divided by total assets. The high indirect personnel ratio, the high ratio of unique projects, the laboratories classified as other, the low asset activity ratio are related to high indirect cost rates.

  • PDF

Indirect Cost Rates and Influence Factors of Steel Factory (철골 공장제작의 간접비율 도출 및 영향요인 분석)

  • Tae, Yong-Ho;Huh, Young-Ki;Kim, Kyung-Won;Ahn, Bang-Ryul
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.05a
    • /
    • pp.180-181
    • /
    • 2013
  • In order to draw indirect cost rates, theories of indirect cost were investigated, and recent field data were collected from steel factories. As a result, it was found that the ratio of indirect labor productivity compared to the direct labor ratio was approximately 17% and the ratio of indirect cost compared to direct cost was approximately 93%. Furthermore, 'The economy of construction industry' and 'size of steel factory' were found to be influence factors of the indirect cost ratio.

  • PDF

ANALYSIS OF STRESS DEVELOPED WITHIN THE SUPPORTING TISSUE OF ABUTMENT TOOTH WITH INDIRECT RETAINER ACCORDING TO VARIOUS DESIGNS OF DIRECT RETAINER AND DECREE OF BONE RESORPTION (편측성 후방연장 국소의치에서 직접유지장치의 설계와 지대치 골흡수에 따른 간접유지장치 지대치 주위조직에 발생하는 응력분석)

  • Lee, Suk-Hyun;Lee, Cheong-Hee;Jo, Kwang-Hun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.1
    • /
    • pp.150-165
    • /
    • 1998
  • For the purpose of evaluating the effect of both direct retainer design and bony absorption degree around abutment of indirect retainer on the supporting tissue of abutment of indirect retainer, dislodging force was transmitted to unilateral distal extension RPD bases. Analysis of stress distributed within the supporting tissue around abutment of indirect retainer was carried out. Using three-dimensional photoelastic stress analysis method and the conclusion is a follows. 1. According to the extent of force which the direct retainer of the most distal abutment tooth, the amount of force transmitted to the abutment tooth of indirect retainer was small. 2. Of all the cases, Mandibular first premolar which was used abutment tooth of indirect retainer, buccal, mesial and distal sides represented compression stress and lingual side represented tensile stress. 3. The more bone resorption of abutment tooth of indirect retainer, the more distortion of buccal and distal side of abutment tooth was existed and the extent of compression stress which was existed and distal side to abutment tooth was large. 4. When the alveolar bone around the abutment with indircet retainer is normal. The amount of force transmitted on abutment with indirect retainer was small in the order of Akers clasp, RPA clasp, RPI clasp. 5. When the alveolar bone around the abutment with indirect retainer has been absorbed 20% and 30%, the amount of force transmitted on abutment with indirect retainer was small in the order of RPA calsp, RPI clasp, Akers clasp. 6. When denture is displaced, shape of the direct retainer reciprocating abutment affect much the function of indirect retainer.

  • PDF

Accuracy Comparison of Blood Pressure among the Direct Measurement Method and Two Automatic Indirect Measurement Methods in the Patients with Various Blood Pressure (다양한 혈압상태에서 직접혈압을 기준으로 HP 자동혈압기와 국산자동혈압기의 정확도 비교)

  • Song Hyo-Sook;Jun Tae-Gook;Choi Eun-Jung;Kim Mi-Jung
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.8 no.3
    • /
    • pp.366-378
    • /
    • 2001
  • Objective: The purpose of this study was to identify differences in measurement methods for blood pressure (Direct measurement, HP automatic indirect measurement, and SE 7000 Korean made indirect measurement), and to evaluate the clinical trial of the Korean made automatic indirect blood pressure measurement. Material & Methods: From June, 1999 to February, 2000, fifty five consecutive patients were randomized into hypertension group (n=20), normotension group (n=20), and hypotension group (n= 15). Measuring blood pressure by indirect methods (HP NIBP M 1008B and SE 7000 NIBP Korean made) was done simultaneously in the same arm with arterial line for direct blood pressure measurement (HP M1006A). The procedures were repeated ten times at intervals of 2 minutes. Statistical analysis was Performed using SPSS (version 8.0 for windows) software package. Values were expressed as means and standard deviation and means were compared using t-test. Statistical significance was considered present with a p value less than 0.05. Results: In the hypertension group and noromotension group, the disparity between HP direct measurement and indirect SE 7000 NIBP did not show any differences compared to the disparity between HP direct measurement and indirect HP NIBP. In the hypotension group, the disparity in the diastolic pressure between HP direct measurement and indirect SE 7000 NIBP was significantly different compared to the disparity between HP direct measurement and indirect HP NIBP (p<0.001), however, disparities in systolic pressure did not showed any differences. Conclusion: Direct blood pressure measurement (HP M1006A) can be replaced with indirect blood pressure measurements (HP NIBP M 1008B & SE 7000 NIBP) in normotension and hypertension patients. Korean made indirect measurement was found to be more accurate compared to HP indirect measurement in hypotension Patients, but more study is needed.

  • PDF

An Ergonomic Analysis on Working Posture Associated with Dental Treatment Using Indirect Viewing Method (간접보기 도구를 이용한 치과 진료 관련 작업자세에 대한 인간공학적 분석)

  • Son, Chang-Won;Choi, Soon-Young;Park, Dong-Hyun
    • Journal of the Korea Safety Management & Science
    • /
    • v.12 no.2
    • /
    • pp.55-64
    • /
    • 2010
  • This study tried to focus on nontraditional job that has not been studied in terms of the subjects associated with MSDs(Musculoskeletal Disorders). Specifically, dental procedure was the job to be analyzed in this study. An alternative method as well as a traditional method for viewing teeth while performing simulated dental procedures. Four graduated students did both methods(direct view and indirect view) as the subjects in this study. The method based on indirect view used a video camera and monitor to view the teeth. The experiment was conducted five times for each subject. The major findings in this study were as follows; 1) Job speed was increased with the repetitions for both methods, 2) Difference of Neck flexion between direct and indirect methods was statistically siginificant(Neck flexion for indirect method was dramatically decreased), 3) Difference of job speed between direct and indirect methods was statistically significant(Job speed for direct method was faster than that of indirect method), 4) Difference of error rate between direct and indirect methods was statistically significant(error rate for direct method was lower than that of indirect method), 5) Even though indirect method did not provide better performance in terms of job speed and error rate yet, it seemed to need a trade-off between two methods in the future since indirect method provided better working postures than that of direct method.

Identification of indirect effects in the two-condition within-subject mediation model and its implementation using SEM

  • Eujin Park;Changsoon Park
    • Communications for Statistical Applications and Methods
    • /
    • v.30 no.6
    • /
    • pp.631-652
    • /
    • 2023
  • In the two-condition within-subject mediation design, pairs of variables such as mediator and outcome are observed under two treatment conditions. The main objective of the design is to investigate the indirect effects of the condition difference (sum) on the outcome difference (sum) through the mediator difference (sum) for comparison of two treatment conditions. The natural condition variables mean the original variables, while the rotated condition variables mean the difference and the sum of two natural variables. The outcome difference (sum) is expressed as a linear model regressed on two natural (rotated) mediators as a parallel two-mediator design in two condition approaches: the natural condition approach uses regressors as the natural condition variables, while the rotated condition approach uses regressors as the rotated condition variables. In each condition approach, the total indirect effect on the outcome difference (sum) can be expressed as the sum of two individual indirect effects: within- and cross-condition indirect effects. The total indirect effects on the outcome difference (sum) for both condition approaches are the same. The invariance of the total indirect effect makes it possible to analyze the nature of two pairs of individual indirect effects induced from the natural conditions and the rotated conditions. The two-condition within-subject design is extended to the addition of a between-subject moderator. Probing of the conditional indirect effects given the moderator values is implemented by plotting the bootstrap confidence intervals of indirect effects against the moderator values. The expected indirect effect with respect to the moderator is derived to provide the overall effect of moderator on the indirect effect. The model coefficients are estimated by the structural equation modeling approach and their statistical significance is tested using the bias-corrected bootstrap confidence intervals. All procedures are evaluated using function lavaan() of package {lavaan} in R.

Performance Comparison between Indirect Evaporative Cooler and Regenerative Evaporative Cooler made of Plastic/Paper (플라스틱/종이 재질의 간접 증발 소자와 재생 증발 소자 성능 비교)

  • Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.1
    • /
    • pp.88-98
    • /
    • 2016
  • The Korean summer is hot and humid, and air-conditioners consume considerable amounts of electricity. In such cases, the simultaneous use of indirect evaporative coolers may help reduce the sensible heat and save electricity. In this study, heat transfer and pressure drop characteristics of indirect or regenerative evaporative coolers made from plastic/paper are investigated. The results showed that heat and mass transfer model based on the ${\epsilon}-NTU$ method predicted the indirect evaporation efficiencies, cooling capacities and pressure drops adequately. Both for indirect or regenerative evaporative cooler, the indirect evaporation efficiency increased with increasing dry channel inlet temperature or relative humidity. The indirect evaporation efficiency of the regenerative evaporative cooler was larger than that of the indirect evaporative cooler.

Development of an Indirect Enzyme-Linked Immunosorbent assay for Rapid Detection of Adulteration of Food Allergen Mackerel in Processed Marine Foods (수산가공식품 중 알레르겐 고등어 혼입여부 신속 검출을 위한 간접효소면역분석법의 개발)

  • Lee, Jeong-Eun;Kim, Ah-Yoon;Kim, Sol-A;Kim, Hyo-In;Park, Ji-Hye;Shim, Won-Bo
    • Journal of Food Hygiene and Safety
    • /
    • v.33 no.3
    • /
    • pp.185-192
    • /
    • 2018
  • The purpose of this study was to develop an indirect enzyme-linked immunosorbent assay (indirect ELISA) based on a monoclonal antibody (MAb) that is specific to mackerel thermal stable-soluble protein (TSSP), that can be used for the rapid detection of mackerel in processed marine foods. Among the four MAbs (3A5-1, 2, 9, and 12) developed in previous studies, the 3A5-2 MAb that showed high specificity and sensitivity were selected and used to develop the indirect ELISA method. The detection range of the indirect ELISA was 0.02%-0.001% and the detection limit of 0.001% was shown. No cross-reaction to other marine products and food ingredients was observed by the indirect ELISA. Processed marine foods containing mackerel with ${\geq}0.3$ O.D. value at 405 nm were estimated as positive samples by the indirect ELISA. Therefore, the indirect ELISA can be used as a rapid and sensitive method to identify mackerel authenticity and adulteration in processed marine foods.

Indirect Composite Restoration (임상가를 위한 특집 1 - 간접 복합레진 수복의 이론과 실제)

  • Hwang, In-Nam;Jang, Ji-Hyun
    • The Journal of the Korean dental association
    • /
    • v.50 no.7
    • /
    • pp.368-376
    • /
    • 2012
  • The demand for tooth-colored restorations has grown considerably during the last decade. Posterior composite restorations have risen in popularity as a result of the development of improved resin composites, bonding systems and operating techniques. A major limitation of direct composite restoration is the difficulty of controlling the polymerization shrinkage. To overcome this limitation, the indirect fabrication of a composite restoration and cementation with resin cement has been advocated. Unfortunately, the current available resin cements with indirect restorations do not always bond to dentin as strongly as dentin adhesive systems bond with direct resin composite restorations. Several procedural strategies have been proposed for indirect composite restoration. In this regard, the rationale for the indication, characteristics and clinical application is described in this paper. As a result, we will try to suggest the evidence-based guidelines for indirect composite restorations by reviewing each available indirect composite products, technical procedure and pronosis.