• Title/Summary/Keyword: increase of detecting distance

Search Result 16, Processing Time 0.022 seconds

Numerical Analysis on the Signal Characteristics for Scattered Far-field of Ultrasonic SH-Wave by the Internal Cavity (재료내 기공결함에 의한 SH형 초음파 원거리 산란장의 신호특성에 대한 수치해석)

  • Lee, Jun-Hyeon;Lee, Seo-Il;Park, Yun-Won
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.1 s.173
    • /
    • pp.163-172
    • /
    • 2000
  • In this study, the scattered far-field due to a cavity embedded in infinite media subjected to the incident SH-wave was calculated by the boundary element method. The effects of cavity shape and distance between internal cavity and internal point in infinite media were considered. The scattered far-field of the frequency domain was transformed into the signal of the time domain by using the Inverse Fast Fourier Transform(IFFT). It was found that the amplitude of scattered signal in time domain decreased with the increase of the distance between the detecting points of ultrasonic scattered field and the center of internal cavity in media. In addition, the time delay was clearly found in time domain waveform as the distance between the detecting points of ultrasonic scattered field and the center of internal cavity was gradually increased.

Mitigation of Adverse Effects of Malicious Users on Cooperative Spectrum Sensing by Using Hausdorff Distance in Cognitive Radio Networks

  • Khan, Muhammad Sajjad;Koo, Insoo
    • Journal of information and communication convergence engineering
    • /
    • v.13 no.2
    • /
    • pp.74-80
    • /
    • 2015
  • In cognitive radios, spectrum sensing plays an important role in accurately detecting the presence or absence of a licensed user. However, the intervention of malicious users (MUs) degrades the performance of spectrum sensing. Such users manipulate the local results and send falsified data to the data fusion center; this process is called spectrum sensing data falsification (SSDF). Thus, MUs degrade the spectrum sensing performance and increase uncertainty issues. In this paper, we propose a method based on the Hausdorff distance and a similarity measure matrix to measure the difference between the normal user evidence and the malicious user evidence. In addition, we use the Dempster-Shafer theory to combine the sets of evidence from each normal user evidence. We compare the proposed method with the k-means and Jaccard distance methods for malicious user detection. Simulation results show that the proposed method is effective against an SSDF attack.

Distance Detection Using Wavelet in Stereo Images (스테레오 영상에서 웨이블릿을 이용한 거리정보 검출)

  • 양석주;백중환
    • Proceedings of the Korea Institute of Convergence Signal Processing
    • /
    • 2000.12a
    • /
    • pp.77-80
    • /
    • 2000
  • In this paper, we propose a method of detecting the distance between two vehicles by computing the disparity of the close-rang vehicle stereo image using two digital cameras. The boundary(or edge) of the object considered the vehicle is obtained by using the modified wavelet transform which has multi-resolution characteristics. We analyze the histogram using the coarse-to-fine method considering a whole feature and increase the resolution to obtain the exact disparity. From the results, the distance of the close-range vehicle is detected effectively by using our proposed method.

  • PDF

An Ultrasensitive FRET-based DNA Sensor via the Accumulated QD System Derivatized in the Nano-beads

  • Yang, Lan-Hee;Ahn, Dong June;Koo, Eunhae
    • BioChip Journal
    • /
    • v.12 no.4
    • /
    • pp.340-347
    • /
    • 2018
  • $F{\ddot{o}}rster$ resonance energy transfer (FRET) is extremely sensitive to the separation distance between the donor and the acceptor which is ideal for probing such biological phenomena. Also, FRET-based probes have been developing for detecting an unamplified, low-abundance of target DNA. Here we describe the development of FRET based DNA sensor based on an accumulated QD system for detecting KRAS G12D mutation which is the most common mutation in cancer. The accumulated QD system consists of the polystyrene beads which surface is modified with carboxyl modified QDs. The QDs are sandwich-hybridized with DNA of a capture probe, a reporter probe with Texas-red, and a target DNA by EDC-NHS coupling. Because the carboxyl modified QDs are located closely to each other in the accumulated QDs, these neighboring QDs are enough to transfer the energy to the acceptor dyes. Therefore the FRET factor in the bead system is enhancing by the additional increase of 29.2% as compared to that in a single QD system. These results suggest that the accumulated nanobead probe with conjugated QDs can be used as ultrasensitive DNA nanosensors detecting the mutation in the various cancers.

Injury and inflammation detection by the application of microcurrent through the skin

  • Hui, Timothy;Petrofsky, Jerrold
    • Physical Therapy Rehabilitation Science
    • /
    • v.2 no.1
    • /
    • pp.31-38
    • /
    • 2013
  • Objective: To determine the efficacy and reliability of measuring direct current microcurrent applied through the skin to determine injury in the underlying tissues. Design: Case control study. Methods: First, microcurrent was measured as decreased blood flow induced hypoxia in healthy subjects. Next, reliability was assessed by measuring over ten days with set variations in pressure and distance between the electrodes. Finally, measurements over sprained ankle were compared to measurements over comparable uninjured areas on the same injured subject. Results: For the blood flow test phase, microcurrent significantly decreased an average of 17% after 5 minutes (p<0.05), remained decreased for 30 seconds, and returned to non-occlusive levels after 2 minutes of normal circulation. The results indicate that the microcurrent decrease was not due to blood flow, and most likely from hypoxic cellular damage. For the reliability phase, the coefficients of variation averaged 10.3% for the shoulder, 14.8% for the low back, and 29.1% for the knee. Changing distance 2.5 cm between the electrodes resulted in insignificant changes. Changes in pressure had some significant effect after an increase in force of 2.6 N, affirming the need for consistent pressure for measurement. For the injury test phase, a significant 69% decrease occurred comparing injured areas to the same area on the uninjured side, and a significant 74% occurred comparing injured and non-injured areas on the same limb. Conclusions: Microcurrent through the skin shows promise as an objective method of assessing a soft tissue injury by detecting damage likely due to hypoxia.

  • PDF

A Study on the In-process Measurement of Metallic Surface roughness in Cylindrical Grinding by Diode Laser (원통연삭가공시 반도체 레이저 빔을 이용한 금속표면거칠기의 인프로세스 측정)

  • 김희남
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1995.03a
    • /
    • pp.1-8
    • /
    • 1995
  • This paper proposed a simple method for measuring surface roughness of ground surface. utilizing non-contact in-process measuring system using the diode laser. The measurement system is consisted of a laser unit with a diode laser and a cylindrical lens a detecting unit with polygon mirror and CCD array sensor. and a signal processing unit with a computer and device. During operation, this measuring system can provide information on surface roughness in the measuring distance with a single sampling and simultanilusly monitor the state of the grind wheel. The experimental results, showed that the increase of the feed rate and the dressing speed an caused increase in the surface roughness and when the surface roughness is 4Rmax-10Rmax, the cutting speed is 1653m/min-1665m/min. the feed rate is 0.2m/min-0.9m/min, the dressing speed is 0.2mm/rev-0.4mm/rev, the stylus method and the in-process method can be obtained the same results. thus under limited working conditions. using the proposed system. the surface roughness of the ground surface during cylindrical grinding can be obtained through the in-process measurement method using the diode laser.

  • PDF

A Study on the In-Process Measurement of Metallic Surface Roughness in Cylindrical Grinding by Diode Laser (원통연삭가공시 반도체 레이저 빔을 이용한 금속표면거칠기의 인프로세스 측정)

  • 김희남;이주상
    • Journal of the Korean Society of Safety
    • /
    • v.10 no.3
    • /
    • pp.30-41
    • /
    • 1995
  • This paper proposed a simple method for measuring surface roughness of ground surface. Utilizing non-contact in-process measuring system using the diode laser. The measurement system is consisted of a laser unit with a diode laser and a cylindrical lens, a detecting unit with polygon mirror and CCD array sensor, and a signal processing unit with a computer and device. During operation, this measuring system can provide information on surface roughness in the measuring distance with a single sampling and simultaniously monitor the state of the grind wheel. The experimental results, showed that the Increase of the feed rate and the dressing speed an caused increase in the surface roughness and when the surface roughness is 4Rmax-10Rmax, the cutting speed is 1653m/min-1665m/min, the table speed is 0.2n1/min -0.9m/min, the dressing speed is 0.2mm/rev~0.4mm/rev, the stylus method and the in-process method can be obtained the same results. Thus, under limited working conditions, using the proposed system, the surface roughness of the ground surface during cylindrical grinding can be obtained through the in-process measurement method using the diode laser.

  • PDF

A Weak Signal Detection Algorithm in Clutter Environment for Indoor Location Estimation based on IR-UWB Radar (IR-UWB 레이더 기반의 실내 위치 추정을 위한 클러터 환경에서 미약신호 검출 알고리즘)

  • Younguk Yun;Jung-woo Sohn;Youngok Kim
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.1
    • /
    • pp.10-17
    • /
    • 2023
  • Purpose: In this paper, a distance estimation technique for indoor location estimation using IR-UWB is proposed and researched. We propose an algorithm that can increase the SNR lowered due to clutter or noise in an indoor environment. Method: In order to clutter suppression and detect weak signals, we analyze the existing studies of background remover, correlation, and singular vector decomposition techniques and propose an algorithm. Result: The proposed algorithm, the average error was 0.57m up to 11.5m, and the error were 0.49m from 6m to 11.5m. the average error rate was reduced by about 1m compared to the previous study. Conclusion: It can be used as a technique for detecting weak signals in clutter and noise environments for distance or location estimation, and can also be used as a human life detection technique to reduce damage to people in a disaster situation by using UWB radar which has highly transparent.

A Study on the Practice of Engineering Education through the Design and Production of Drones for Detecting Objects in Disaster Area (재난 지역의 물체를 탐지하기 위한 소형 무인기 설계와 제작을 통한 공학 교육의 실천에 관한 연구)

  • Kang, Byeong-Ju;Lee, Dae-Hee;Chang, Eun-Young
    • Journal of Practical Engineering Education
    • /
    • v.9 no.1
    • /
    • pp.15-21
    • /
    • 2017
  • In order to satisfy the graduation requirements, the graduation work should be presented as an engineering dissertation system of the produced work and an outline of the procedure made by the major unit in accordance with the graduation thesis submission rules, and suggests necessary matters for improvement. The design content relates to a small unmanned aerial vehicle configuration for detecting personnel or objects in a disaster area. It is equipped with an infrared sensor and a GPS in the drone, the drone is control by using Blutooth communications. The drones detect the target and use the GPS to determine the location. As a result of the experiment, it was possible to detect the structure object within the range of 3~4 m, confirm the transmission of the position value in real time, and increase the communication distance by using RF communication.

Design and Implementation of Cattle Behavior Detection System based on Internet of Things (사물 인터넷 기반 소 행동 특성 관찰 시스템 설계 및 구현)

  • Lee, Ha-Woon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.12 no.6
    • /
    • pp.1159-1166
    • /
    • 2017
  • Cattle behavior detection system based on Internet of Things is designed and implemented by using gyroscope and acceleration sensor, Arduino pro-mini and bluetooth module. The implemented system measures cattle's moving and the measured data are transmitted to smart phone by bluetooth module. They are displayed by 2-dimensional graph on the smart phone and the number of cattle's step are calculated from the graph. The detected and gathered data from the system are analyzed by the proposed algorithm to decide which cows are in the estrus or not, and the proposed system can be used to increase the success rate of artificial insemination in normal estrus by detecting cow's behaviors such as the number of steps and jumping. In this paper, the implemented cattle behavior detecting system are strapped on cattle's leg and it measures cattle behaviors for determining that a cattle is estrus or not by the proposed algorithm. In the future research, the system which lengthens communication distance and increases the number of cattle under the test will be considered and also the measured data will be database for cattle research.