• Title/Summary/Keyword: in-site test

Search Result 3,237, Processing Time 0.039 seconds

An Experimental Study for Establishment of On-Site Quality Control of Repair Material by the mechanized construction (기계화시공에 의한 보수재료의 현장품질관리확립을 위한 실험적 연구)

  • Cho Bong Suk;Jang Jae Bong;Kim Yong Ro;Kang Suk Pyo;Hong Sung Yun;Kim Moo Han
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.160-163
    • /
    • 2004
  • In domestic, various repair materials and method systems to keep up with these reinforced concrete deteriorated due to salt damage, carbonation, chemical decay et. developed and applied. However, on-site quality control of various repair materials and method systems isn't achieved desirably because it is depend completely on a men of experience' opinions above all else regardless of various on-site environments. In this background, mock up test with due regard to real on-site environments was performed to secure fundamental data for establishment of desirable on-site quality control. Mock up test using repair mortar analyzed from angles of construction methods, mechanical spraying pressures, W/M. Construction methods were designed manpower method and spraying method, spraying pressures were designed 32, 42, 52 psi, W/M were designed 14.4, 15.4, $16.4\%$. And compressive strength, Chloride ion diffusion coefficient, bond strength, SEM. of mock up test specimens were evaluated. In conclusion, we confirmed excellency of mechanical spraying pressures, fined extremely excellency of condition of spraying pressure 42 ps, W/M $14.4\%$ within this study. therefore the results of this study will be useful to provide fundamental data for establishment of desirable on-site quality control.

  • PDF

Field Application of New Seismic Site Characterization Using HWAW(Harmonic Wavelet Analysis of Wave) Method (HWAW(Harmonic Wavelet Analysis of Wave) 방법을 이용한 새로운 탄성파 지반조사기법의 현장 적용)

  • 박형춘;김동수;이병식
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.6
    • /
    • pp.51-59
    • /
    • 2004
  • The evaluation of shear modulus is very important in various fields of civil engineering. In this paper, the site characterization method using HWAW method is applied to determine shear wave velocity profile of two test sites in order to verify the field applicability of HWAW method. Shear wave velocity profiles by HWAW method are compared with shear wave velocity profiles by SASW test and PS-Suspension Logging test. Through field applications, it is shown that HWAW method can minimize the effect of noise and lateral non-homogeneity of the site and determine detailed local shear wave velocity profile of site.

The Field Application of Miniature Cone Penetration Test System in Korea (소형콘관입시험(Miniature Cone Penetration Test)의 국내현장 적용)

  • Yoon, Sung-Soo;Ji, Wan-Goo;Kim, Jun-Ou;Kim, Rae-Hyun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.349-360
    • /
    • 2009
  • The cone penetration test(CPT) has gained its popularity in site characterization indebted by its reliability, speed, economy, and automatic measurement system since its development in the 1930s. The CPT results, commonly consisting of cone tip resistance, sleeve friction, and pore water pressure measurements, allow us to classify soils as well as to reveal their engineering characteristics. The site condition at which the CPT is allowable is often dependent on the capacity of a CPT system. In Korea, it has been considered that the CPT could be appled only to soft soils in most cases because CPT systems available for stiff soils are very rare due to their expensive procurement and maintenance cost. Luoisiana Transportation Research Center(LTRC) has developed and implemented a field-rugged continuous intrusion miniature cone penetration test(CIMCPT) system since the late 1990s. The miniature cone penetrometer has a sectional cone area of $2cm^2$ allowing system capacity reduction compared to the standard $10cm^2$ cone penetrometer. The continuous intrusion mechanism allows fast and economic site investigation. Samsung Engineering & Construction has recently developed and implemented a similar CIMCPT system based on its original version developed in LTRC. The performance of the Samsung CIMCPT system has been investigated by calibration with the standard CPT system at a well-characterized test site in Pusan, Korea. In addition, scale effect between the miniature cone penetrometer and the standard cone penetrometer has been investigated by comparing the field test results using the both systems.

  • PDF

International Joint Research for the Colloid Formation and Migration in Grimsel Test Site: Current Status and Perspectives

  • Sang-Ho Lee;Jin-Seok Kim;Bong-Ju Kim;Jae-Kwang Lee;Seung Yeop Lee;Jang-Soon Kwon
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.20 no.4
    • /
    • pp.455-468
    • /
    • 2022
  • Colloid Formation and Migration (CFM) project is being carried out within the Grimsel Test Site (GTS) Phase Ⅵ. Since 2008, the Korea Atomic Energy Research Institute (KAERI) has joined CFM to investigate the behavior of colloid-facilitated radionuclide transport in a generic Underground Research Laboratory (URL). The CFM project includes a long-term in-situ test (LIT) and an in-rock bentonite erosion test (i-BET) to assess the in-situ colloid-facilitated radionuclide transport through the bentonite erosion in the natural flow field. In the LIT experiment, radionuclide-containing compacted bentonite was equipped with a triple-packer system and then positioned at the borehole in the shear zone. It was observed that colloid transport was limited owing to the low swelling pressure and low hydraulic conductivity. Therefore, a postmortem analysis is being conducted to estimate the partial migration and diffusion of radionuclides. The i-BET experiment, that focuses more on bentonite erosion, was newly designed to assess colloid formation in another flow field. The i-BET experiment started with the placement of compacted bentonite rings in the double-packer system, and the hydraulic parameters and bentonite erosion have been monitored since December 2018.

유류오염토양 복원을 위한 설계인자 선정에 관한 연구

  • 조장환;전권호;서창일;박정구
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.04a
    • /
    • pp.293-296
    • /
    • 2004
  • The objective of this study was to decide the designing factor for remediaton of the contaminated site. The soil and ground-water samples were analyzed and hydro- geological characteristics was assayed for the survey of pollution level. Also air-permeability test and MPN(most probable number) test were conducted for selecting the designing factor. The contaminants were mainly found in north-west part of the site and were expected to move toward the south. Ex-situ technology was expected more useful than in-situ one with the results of air-permeability test saying that air permeability was relatively low. Additional microbes were expected for remediation efficiency because residual microbes were loosely populated. The choosing of the designing factor was requisite for remediation of contaminated site.

  • PDF

Analysis of the Normalized Site Attenuation Using the Moment Method (정규화 시험장감쇠량의 모멘트 법 해석)

  • Ki Chai Kim
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.30A no.11
    • /
    • pp.48-57
    • /
    • 1993
  • The ANSI recently adopted normalized site attenuation(NSA) as a validation procedure of open area test sites. In this paper, the theoretical NSA values specified in the truth vlues of NSA were calculated for an ideal test site when tuned dipoles are used. A method of moments technique is employed to evaluate these NSA values. The calculated NSA values are more accurate than that of the ANSI.

  • PDF

Study of Selection Plan of Circuit breakers, Cables and Modeling of Korean Low Voltage Electrical Installation integration Test Site based on IEC 60364 (IEC 60364 기반의 한국형 저압전기설비 통합 실증단지 모델링 및 차단기와 케이블의 선정 방안 고찰)

  • Kim, Doo-Ung;Ryu, Kyu-Sang;Kim, Han-Soo;Shin, Dae-Sung;Ryu, Ki-Hwan;Kim, Chul-Hwan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.9
    • /
    • pp.59-64
    • /
    • 2015
  • IEC is an international standards which are used in many countries with Europe as the center. IEC standard is introduced in Korea according to WTO/TBT agreements, however until now there are no buildings in Korea which are designed applying IEC standard. Therefore, KEA(Korea Electric Association) is scheduled to construct Korean low voltage electrical installation integration test site which is designed applying IEC standard. In this paper, before being under construction of Korean low voltage electrical installation integration test site, power substation is modeled based on real design parameters and method to select circuit breakers and cables is presented applying IEC standard in the modeled power substation. EMTP(ElctroMagnetic Transient Program) is used for simulation program. EMTP which is power system analysis program is easy to model power system and power substation.

Analysis of Application Cases and Evaluation of Effectiveness on Portable Dynamic Cone Penetration Test (DCPT) to Identify the Deterioration Cause of Damaged Reinforced Earth Walls (보강토옹벽의 피해원인 규명을 위한 휴대형 동적콘관입시험(DCPT) 적용사례 분석 및 효용성 평가)

  • Lee, Kwang-Wu;Cho, Sam-Deok
    • Journal of the Korean Geosynthetics Society
    • /
    • v.19 no.4
    • /
    • pp.95-109
    • /
    • 2020
  • In this study, a total of six site cases were reviewed to assess the site applicability of portable dynamic cone penetration test (DCPT) by identifying the cause of damage to the damaged reinforced earth wall using portable dynamic cone penetration test. An improved dynamic concrete penetration tester was used at the site to enable ground surveys of more than 6 meters. The test results were compared with the results of the standard penetration test (SPT) and the correlation was analyzed. Through the analysis of various field application cases, it was found that portable dynamic cone penetration test was very convenient to apply at the site of the damaged reinforced earth wall, and DCPT could play a major role in identifying the cause of damage and verifying stability of the retaining wall by continuously identifying the ground strength. In addition, it was found that the results of the dynamic cone penetration test and the standard penetration test showed a correlation of N≒(1/3~2/3)·Nd in sandy soil.

The Quantitative Analysis of Alternative-Decision in Missile Test: Focusing on Selecting a Foreign Test Site through Data Envelopment Analysis (미사일 시험을 위한 대안결정의 정량적 분석: 자료포락분석을 이용한 국외 시험장 선정을 중심으로)

  • Han, Seung Jo
    • Convergence Security Journal
    • /
    • v.20 no.4
    • /
    • pp.3-12
    • /
    • 2020
  • Although the related regulations or guidelines are not specified in the defense weapon system R&D process, R&D authorities frequently encounter problems that require rational decision-making. If the rational process is not applied in the matter of alternative choice, the project could be disrupted, which can result in longer project periods or more resource provision. In particular, a variety of decision-making methods are needed for test&evaluation of missile R&D. The issue of selecting a test site is one of the representative decision-making problems. If it is needed to determine the priority of multiple sites, Delphi Method and Analytic Hierarchy Process(AHP) will be applied. However, if the input of cost is to be considered, Data Envelopment Analysis(DEA) is more valuable to solve the problem. This paper proposes a solution to handle quantitatively various decision-making problems that can occur in missile flight test, and shows how DEA is applied through a simulated case study of selecting a foreign test site.

Development of Conformance Test Tools for Terrestrial DMB Broadcast Web Site Services (지상파 DMB 방송웹사이트 서비스 송수신 정합 시험 도구 개발)

  • Kim, Yong-Han;Moon, Su-Han;Chae, Young-Seok
    • Journal of Broadcast Engineering
    • /
    • v.12 no.3
    • /
    • pp.214-221
    • /
    • 2007
  • In this paper, we presents conformance test tools for the broadcast web site (BWS) service which is one of the data services for terrestrial digital multimedia broadcasting (T-DMB). First, the methodology for the conformance test is established for both transmitters and receivers of T-DMB BWS services. The test tools consist of three parts: BWS bitstream analyzer, BWS reference decoder (software) module, and BWS test bitstreams. For testing transmitted BWS bitstreams, we developed the bitstream analyzer. For testing BWS receivers, we developed the reference Ifecoder module and created the test bitstreams. Actually the bitstream analyzer developed in this paper was used for the verification of the test bitstreams. The same test bitstreams are fed to a BWS decoder module under test and the reference decoder module and the results from the two are compared for verification. The test tools can be used for the test of all the protocol and textual/image specifications related to BWS including MOT protocol, HTML, PNG, MNG, JPEG, and Ecma Script.