• Title/Summary/Keyword: improvement factor

Search Result 3,547, Processing Time 0.026 seconds

A Systematic Power Factor Improvement Method for an Electro Acoustic Transducer with Low Coupled Dual Resonances (상호 결합이 적은 두 개의 공진점을 갖는 광대역 전기 음향 변화기를 위한 역률 개선 회로 설계 방법 연구)

  • Lim, Jun-Seok;Pyeon, Yong-Guk
    • The Journal of the Acoustical Society of Korea
    • /
    • v.31 no.7
    • /
    • pp.480-486
    • /
    • 2012
  • In the design of electro acoustic transducer, power factor improvement circuit is more required rather than impedance matching if the driving power amplifier has little inner resistance. Many research results have been focused on the power matching circuit designing for transferring maximum power in the wideband. There are few results in the designing study on the power factor improvement for the wide band electro acoustic transducer. In this paper, we propose a new design method on the power factor improvement for the wide band electro acoustic transducer. The proposed method consists of two steps, the chebyschev matching method and the constrained optimization, respectively.

The Design and Experiment of Power Factor Improvement Circuit for a Underwater Electro Acoustic Transducer with Low Coupled Dual Resonances (상호 결합이 적은 두 개의 공진점을 갖는 수중용 광대역 전기 음향 변화기를 위한 역률 개선 회로 설계 및 실험)

  • Lim, Jun-Seok;Pyeon, Yong-Guk
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38B no.12
    • /
    • pp.967-975
    • /
    • 2013
  • In the design of underwater electro acoustic transducer, power factor improvement circuit is more required rather than impedance matching if the driving power amplifier has little inner resistance. Many research results have been focused on the power matching circuit designing for transferring maximum power in the wideband. There are few results in the designing study on the power factor improvement for the wide band underwater electro acoustic transducer. In this paper, we set up a new design method on the power factor improvement for the wide band electro acoustic transducer, and confirm its feasibility by the experiments.

Power Factor improvement of Power Conversion Equipment for High Pressure Sodium Lamps (고압 나트륨 램프 구동용 전력변환장치의 역률 개선)

  • Lee, S.H.;Suh, K.Y.;Lee, H.W.;Lee, S.H.;Mun, S.P.
    • Proceedings of the KIEE Conference
    • /
    • 2002.04a
    • /
    • pp.147-150
    • /
    • 2002
  • HPSL(High Pressure Sodium lamp)have attracted much attention in recent years, because they offer high luminous efficiency and very long life. Recently, AC-DC converters have been widely as power factor improvement circuits in the power conversion equipment An application of the ZVT-PWM(Zero Voltage Transition Pulse Width Modulation) boost converter, which has great advantage on miniaturization and high power density, to the power factor improvement circuit of the HPSL inverter are described to identify the power factor correction characteristics of the inverter. In this paper the series-parallel resonant inverter(electronic ballast) for driving a HPS lamp is discussed. Finally, a power factor corrector is cascaded in front of the electronic ballast. Consequently, a high power factor above 0.99 and low THD on the line current can be achieved.

  • PDF

Optimal Preventive Maintenance Policy with Cost-dependent Improvement Factor (비용 종속적인 개선지수를 고려한 최적 예방보전 정책)

  • Hong, Seok-Soo;Park, Jong-Hun;Lie, Chang-Hoon
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.36 no.2
    • /
    • pp.108-116
    • /
    • 2010
  • The maintenance of a deteriorating system is often imperfect. Previous studies have shown that the imperfect preventive maintenance (PM) can reduce the wear out and aging effects of deteriorating systems to a certain level between the conditions of as good as new and as bad as old. In this paper, we employ the concept of the improvement factor in investigating two optimal PM policies; failure limit policy and periodic PM policy. We redefine the improvement factor model as a function of the cost of PM, using this concept, we derive the conditions of optimal PM policies and formulate expressions to compute the expected cost rate. Based on this information, the determination of the maintenance policies which minimize the cost rate is examined. Numerical examples for the Weibull distribution case are also given.

A Affect on Quality Management Factors and Performance - Focus on Construction Industry - (품질경영의 활동요인과 경영성과와의 관련성에 관한 연구 - 건설업을 중심으로 -)

  • Lee, Lae Hyung;Kim, Byeong Chan
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.9 no.3
    • /
    • pp.195-209
    • /
    • 2013
  • Purpose of this study is to empirically consider relation between QM activity factor and management result. For this, following 6 major variables of QM activity were established as independent variable; CEO's leadership, communication, process control, standardization, full participation and education/training while satisfaction of members and improvement of quality were established as dependent variable. And, a model was set up and hypothesis verification was conducted on the basis of data collected through questionnaires. The results are summarized as follows; First, QM factors which influenced satisfaction of members in management result were CEO's leadership, communication, process control, full participation and education/training but 'standardization' factor was not statistically significant. Second, QM factors which influenced improvement of quality in management result were CEO's leadership, communication, standardization, full participation and education/training but 'process control' factor was not statistically significant. Third, among main factors of QM activity, the factor which preferentially influenced satisfaction of members was 'full participation' factor while the factor which preferentially influenced improvement of quality was 'standardization' factor. According to such results, it is required to seek a statistical method regarding QM activity with focus on the factor of 'full participation' and 'standardization' among other things for the purpose of satisfaction of members as well as improvement of quality. It is believed that implication of this study can be useful information to realize management result considering main factors of QM activity and that it also can be basic reference data to seek a statistical method for satisfaction of members and improvement of quality by grasping core factors having influence over QM activity.

A Study on the Characteristic of Dye-sensitized Solar Cell by Controlling the Roughness Factor of Counter Electrode (염료감응형 태양전지의 상대전극 Roughness Factor 조절을 통한 셀 특성 연구)

  • Son, Min-Kyu;Seo, Hyun-Woong;Lee, Kyoung-Jun;Kim, Jeong-Hoon;Kim, Hee-Je
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.428-430
    • /
    • 2008
  • Dye-sensitized solar cell has many internal resistant components such as Pt counter electrode, $TiO_2$/dye/electrolyte, charge diffusion, sheet resistance of TCO. Among these, the resistance about the counter electrode can be reduced by increasing the roughness factor of Pt counter electrode. This causes the increase of fill factor and improvement of efficiency. And the amount of light reflection on the counter electrode also increases as the roughness factor goes up. In our experiment, we suggest a new deposition structure of Pt thin film that is a stepped-type structure. The more step lines are in the counter electrode, the more roughness factor is. As a result, we get the improvement of fill factor and efficiency by controlling the roughness factor of counter electrode.

  • PDF

Analysis of robust performance improvement using loop shaping and structured singular value (루프쉐이핑과 구조적 특이치를 이용한 견실성능 개선)

  • 방경호;오도창;박홍배
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.33B no.5
    • /
    • pp.17-24
    • /
    • 1996
  • In this paper, we present a robust performance improvement method for the NLCF(normalized left coprime factor) uncertain structure using loop shaping and the structure singular value. For this, we select weighting functions for a loop shaping considering condition numer, and transform the NLCF uncertain structure into the 4-block structure. However, we can't get a good performance on account of the restriction of weighting functions. To cope with this, we motivate the use of structured singular vlaue in the robust performance improvement procedure. After all, the robust performance improvement can be obtained by a factor W$_{a}$ and a scaling factor of D-K iteration.

  • PDF

Single-phase SRM Drive with Torque Ripple Reduction and Power Factor Improvement

  • Lee, D.H.;Ahn, J.W.;Lee, Z.G.
    • Proceedings of the KIEE Conference
    • /
    • 2006.04b
    • /
    • pp.57-61
    • /
    • 2006
  • In the single-phase switched reluctance motor (SRM) drive, the required DC source is generally supplied by the circuit consisting of bridge rectifier and large filter capacitor connected with DC line terminal. Due to the large capacity of the capacitor, the charged time of capacitor is very short from the AC source. Lead to the bridge rectifiers draws pulsating current from the AC source side, which results in reduction of power factor and low system efficiency. Therefore a novel single-phase SRM drive system is presented in this paper, which includes drive circuit realizing reduction of torque ripple and improvement of power factor with a novel switching topology. The proposed drive circuit consists of one switching part and diode, which can separate the output of AC/DC rectifier from the large capacitor and supply power to SRM alternately, in order to realize the torque ripple reduction and power factor improvement through the switching scheme. In addition, the validity of the proposed method is tested by some simulations and experiments.

  • PDF

A Method of ROL Improvement for the Motor Operated Gate Valve Operated in the High Differential Pressure Condition (고차압에서 운전되는 모터구동 게이트밸브의 부하율 향상 방안)

  • Kim, D.W.;Yoo, S.Y.
    • The KSFM Journal of Fluid Machinery
    • /
    • v.8 no.1 s.28
    • /
    • pp.16-22
    • /
    • 2005
  • This paper presents the method of ROL(Rate Of Loading) improvement for the Motor Operated Gate Valve operated in high differential pressure condition. ROL is one of the most important evaluation parameters for the valve ability. It is close to correlation in stem factor (SF) and appears different value by the differential pressure of fluid. ROL and SF are analyzed by the static test and dynamic test. The obtained result show that the modification of stem factor is very important factor for the ROL improvement. In order to obtain the same value of SF between static and dynamic test, stem and stem nut should be combined appropriately by the repetition test.

A Method of ROL Improvement for the Motor Operated Gate Valve Operating in the High Differential Pressure Condition (고차압에서 운전되는 모터구동게이트밸브의 부하율 향상 방안)

  • Kim, D.W.;Park, S.G.;Hong, S.Y.;Yooh, S.Y.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.562-567
    • /
    • 2003
  • This paper presents the method of Rate of Loading(ROL) improvement for the Motor Operated Gate Valve operating in high differential pressure condition. The character of ROL and Stem Factor is analyzed. Static test and dynamic test were performed and acquired the diagnosis signal for the valve closing stroke. The result of this study is the modification of stem factor is very important factor for the ROL improvement. In order to obtain the same value of dynamic test thread friction coefficient stem and stem nut should be combined appropriately.

  • PDF