• Title/Summary/Keyword: impressions

Search Result 425, Processing Time 0.02 seconds

Clinical comparison of marginal fit of ceramic inlays between digital and conventional impressions

  • Franklin Guillermo Vargas-Corral;Americo Ernesto Vargas-Corral;Miguel Angel Rodríguez Valverde;Manuel Bravo;Juan Ignacio Rosales Leal
    • The Journal of Advanced Prosthodontics
    • /
    • v.16 no.1
    • /
    • pp.57-65
    • /
    • 2024
  • PURPOSE. The aim of this stuldy was to compare the clinical marginal fit of CAD-CAM inlays obtained from intraoral digital impression or addition silicone impression techniques. MATERIALS AND METHODS. The study included 31 inlays for prosthodontics purposes of 31 patients: 15 based on intraoral digital impressions (DI group); and 16 based on a conventional impression technique (CI group). Inlays included occlusal and a non-occlusal surface. Inlays were milled in ceramic. The inlay-teeth interface was replicated by placing each inlay in its corresponding uncemented clinical preparation and taking interface impressions with silicone material from occlusal and free surfaces. Interface analysis was made using white light confocal microscopy (WLCM) (scanning area: 694 × 510 ㎛2) from the impression samples. The gap size and the inlay overextension were measured from the microscopy topographies. For analytical purposes (i.e., 95-%-confidence intervals calculations and P-value calculations), the procedure REGRESS in SUDAAN was used to account for clustering (i.e., multiple measurements). For p-value calculation, the log transformation of the dependent variables was used to normalize the distributions. RESULTS. Marginal fit values for occlusal and free surfaces were affected by the type of impression. There were no differences between surfaces (occlusal vs. free). Gap obtained for DI group was 164 ± 84 ㎛ and that for CI group was 209 ± 104 ㎛, and there were statistical differences between them (p = .041). Mean overextension values were 60 ± 59 ㎛ for DI group and 67 ± 73 ㎛ for CI group, and there were no differences between then (p = .553). CONCLUSION. Digital impression achieved inlays with higher clinical marginal fit and performed better than the conventional silicone materials.

Three dimensional accuracy analysis of dental stone casts fabricated using irreversible hydrocolloid impressions (알지네이트 인상체에서 제작된 치과용 석고 모형의 정확도에 대한 삼차원 디지털 분석)

  • Joo, Young-Hun;Lee, Jin-Han
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.4
    • /
    • pp.316-328
    • /
    • 2015
  • Purpose: The objects of this study was to evaluate the accuracy of the dental stone casts made from alginate impressions according to storage condition and stone pouring time. Materials and Methods: Each of upper and lower impressions of dental model was taken. The dental stone models were made immediately, 10, 30, 60, 180, 360 minutes after the impressions were taken at each storage condition. 3D models were constructed by scanning the stone model using 3D laser scanner. With Reference points, positioned on digital models, linear measurements of the dimensional change were compared by 3D metrology software, 3D average models were made and superimposition to identify the specific site of dimensional change and to measure surface deviation (mm). Results: Dental stone models which were made immediately after taking the impression showed the smallest linear dimensional change. As the stone pouring time was prolonged, the linear dimensional change was increased. More than 180 minutes after impression taking, linear dimensional change and surface distortion increased in the posterior molar region, regardless of the storage condition. Conclusion: For the optimum accuracy of the dental stone casts, alginate impression should be poured as soon as possible. If there were a need for storing, a humidor with 100% relative humidity must be used and be stored less than 180 minutes to fabricate the accurate dental model.

Accuracy of Digital Impression Made from Different Elastomeric Impression Materials: Three-Dimensional Superimpositional Analysis (치과용 탄성 인상재를 기반으로 채득된 디지털 모형의 정확성 연구: 3차원 중첩 분석)

  • Kim, Ki-Baek;Jung, Jae-Kwan;Kim, Jae-Hong
    • Journal of dental hygiene science
    • /
    • v.14 no.2
    • /
    • pp.94-100
    • /
    • 2014
  • The purpose of this study was to evaluate the accuracy of digitized elastomeric impression materials of crown abutment, using non-contact white light scanner and virtual three-dimensional superimpositional analysis. The stone models and impressions were digitized white light scanner to create three-dimensional surface models. Stone models were used as CAD reference model (CRM). The resulting point clouds (ASC file) from digitization of impressions using converting software. Discrepancies between the points in the point clouds and CRM were measured by superimpositional software. Mean and standard deviation of values of discrepancies were analyzed by one-way ANOVA and multiple comparison (${\alpha}=0.05$). The mean discrepancy between the impressions for the extra-light body (XLB), light body (LB), and heavy body (HB) group were $5.10{\pm}1.45{\mu}m$, $6.30{\pm}1.87{\mu}m$, $9.80{\pm}1.52{\mu}m$, respectively. The different impression materials affected the digitization of impressions significantly (p<0.05). As a result, digitization of elastomeric impression materials on dental scanner was influenced by material sort.

Accuracy assessment of implant placement using a stereolithographic surgical guide made with digital scan (디지털 스캔을 이용하여 제작된 임플란트 수술가이드의 정확도)

  • Jeong, Seung-Mi;Fang, Jeong-Whan;Hwang, Chan-Hyeon;Kang, Se-Ha;Choi, Byung-Ho;Fang, Yiqin;Jeon, Hyongtae;An, Sunghun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.2
    • /
    • pp.111-119
    • /
    • 2015
  • Purpose: The objective of this study was to evaluate the accuracy of a stereolithographic surgical guide that was made with information from intraoral digital impressions and cone beam CT (CBCT). Materials and methods: Six sets of resin maxilla and mandible models with missing teeth were used in this study. Intraoral digital impressions were made. The virtual models provided by these intraoral digital impressions and by the CBCT scan images of the resin models were used to create a surgical guide. Implant surgery was performed on the resin models using the surgical guide. After implant placement, the models were subjected to another CBCT scan to compare the planned and actual implant positions. Deviations in position, depth and axis between the planned and actual positions were measured for each implant. Results: The mean deviation of the insertion point and angulation were 0.28 mm and $0.26^{\circ}$, apex point were 0.11 mm and 0.14 mm respectively. The implants were situated at a mean of 0.44 mm coronal to the planned vertical position. Conclusion: This study demonstrates that stereolithographic surgical guides created without the use of impressions and stone models show promising accuracy in implant placement.

Combined use of direct and indirect digital impression in temporary denture fabrication (직접 및 간접 디지털 인상을 병용한 임시 의치 제작 증례)

  • Ji-Su Park;Cheong-Hee Lee;Kyu-Bok Lee;Du-Hyeong Lee;Hyun-Ji Yu;So-Yeun Kim
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.40 no.3
    • /
    • pp.159-168
    • /
    • 2024
  • Through the use of intraoral scanners, it is possible to obtain intraoral scan impressions and produce prostheses. This approach is also being attempted not only in dentate patients but also in edentulous patients. However, obtaining scans of edentulous areas can be more challenging than scanning dental areas, and there may be limitations, especially in capturing the details of the mucosal tissues. On the other hand, when obtaining impressions with intraoral scanners, simultaneous recording of the occlusal relationship of the maxilla and mandible can reduce the number of patient visits and expedite the restoration process. In this case, we aimed to combine the advantages of direct intraoral scanning and indirect digital impressions obtained after traditional impression-taking by merging two types of scan files. Consequently, in patients with partially edentulous arches, we sought to provide effective interim prostheses through direct and indirect digital model impressions and report our findings accordingly.

The Effect of Sleeve and Skirt Width . Length Variation of Dress on Impression Formation (원피스드레스의 소매와 스커트폭.길이변화가 인상형성에 미치는 영향)

  • 이웅희;강경자
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.21 no.6
    • /
    • pp.1060-1071
    • /
    • 1997
  • The purpose of this study is to identify the effect of clothing cues(sleeve and skirt width, length) on female impressions. The experimental materials developed for this study are a set of stimuli and response scales. The stimuli are 16 pictures manipulated with sleeve and skirt width · length variations by computer drawing. The experimental design consists of 3 factorial design: (1) sleeve shapes(plain, upper expanded, below expanded, all expanded) (2) skirt width (wide, narrow) (3) skirt length(long, short) The 7-point semantic differential response scale designed for visual evaluation of female' s impression formation on sleeve shape and skirt width · length is 27 bipolar adjectives. The results of this study are as follows: 1. When we analize the impressions of female figure by sleeve shape and width · length of skirt, it becomes clear that maturity, modernity, attention, elegance and tenderness are proved to be important. Among these five factors, maturity, modernity and attention are identified as more important ones. 2. Sleeve shape have an effect on all factors except maturity and the effects of sleeve on the four factors are not striking. ' Width of skirt are most influential to the maturity and attention, but it does not have any effect on modernity. However two factor, that is width of skirt and sleeve have an effects on modernity, attention and tenderness. ' The length of skirt has an effects on the tenderness, elegance and modernity, but it dose not have any effect on attention. But width and length of skirt have an effects on attention, tenderness and modernity The length of skirt and sleeve have an effect on tenderness.

  • PDF

A Study on Visual Comfort for Compound Lighting Control Method of Applied Daylighting (자연채광의 응용에 의한 합성조명방식의 시각적 쾌적성에 관한 연구)

  • Han, Sang-Pil;Jeon, Yong-Han;Han, Sang-Chul
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.spc3
    • /
    • pp.199-206
    • /
    • 2012
  • The purpose of this study is to understand the change of impression by comparing the uniformity lighting with the compound lighting. In previous study, we proposed a light controlling method to harmonize daylight from a window and artificial lights from a ceiling and obtained the results to support our method. We referred this method as the Adjusted Compound-Lighting Model (AC Model). The experiment is carried out with the scaled-models and mock-up spaces that were supposed to be an office space. One is lit by the uniform lighting and the other by the compound lighting in each experimental space. In order to present varying illuminance distributions, the two variables were used in this study. Subjects were asked to evaluate the point of difference by semantic differential rating on their overall impression after comparing with two rooms. The results showed that the impressions of compound lighting were more positive score than that of uniformity lighting on the items of 'dim-bright', 'dislike-like', 'artificial-natural' and 'closed-open', and that there was no significant difference in impressions between two spaces on other items.

Adaptation of zirconia crowns created by conventional versus optical impression: in vitro study

  • Cetik, Sibel;Bahrami, Babak;Fossoyeux, Ines;Atash, Ramin
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.3
    • /
    • pp.208-216
    • /
    • 2017
  • PURPOSE. The aim of this study was to compare the precision of optical impression (Trios, 3Shape) versus that of conventional impression (Imprint IV, 3M-ESPE) with three different margins (shoulder, chamfer, and knife-edge) on Frasaco teeth. MATERIALS AND METHODS. The sample comprised of 60 zirconia half-crowns, divided into six groups according to the type of impression and margin. Scanning electron microscopy enabled us to analyze the gap between the zirconia crowns and the Frasaco teeth, using ImageJ software, based on eight reproducible and standardized measuring points. RESULTS. No statistically significant difference was found between conventional impressions and optical impressions, except for two of the eight points. A statistically significant difference was observed between the three margin types; the chamfer and knife-edge finishing lines appeared to offer better adaptation results than the shoulder margin. CONCLUSION. Zirconia crowns created from optical impression and those created from conventional impression present similar adaptation. While offering identical results, the former have many advantages. In view of our findings, we believe the chamfer margin should be favored.

The Effects of Women's Clothing Styles on the Impression Formation -Focusing on the Characteristics of the Perceiver- (여성 의복스타일이 인상형성에 미치는 영향 - 지각자 특성을 중심으로 -)

  • 류숙희;류지은
    • The Research Journal of the Costume Culture
    • /
    • v.9 no.4
    • /
    • pp.639-650
    • /
    • 2001
  • The purpose of this study is to investigate whether characteristics of the perceiver make differences in impressions of clothing types in the situation of first impression formation. Questionnaire was used as major method of gathering data. A poll of 650 men h women between the ages of 20∼39 living in Daegu was taken by the author for this study. Factor analysis, cluster analysis, frequency, ANOVA-test and t-test were implemented with the SPSS-package. The characteristics of clothing types used in our experiments include: sexy, masculine, feminine, dramatic, elegant-classic and casual. The results are as follows; 1 . Men favored sexy clothes more than women, whereas women tended to like masculine clothes more than men. 2. Positive, open-minded men were accepting of masculine, feminine, dramatic and elegant-classic clothes, but gave unfavorable responses toward casual clothes. In contrast, positive open-minded women continued to show unfavorable impressions of sexy clothes. Attitude towards clothing affected the outlook towards clothing by the perceiver 3. Clothing-dependent/vain men favored sexy, dramatic and elegant-classic clothes, while clothing-indifferent men tended toward casual clothes. Furthermore, clothing-dependent/vain women were interested in the feminine style, but women in general continued to show negative responses toward sexy and dramatic clothes.

  • PDF

신개발 국산 부가중합 실리콘 인상재의 젖음성과 기포발생에 관한 비교 연구

  • 조리라;정경호;김경남
    • The Journal of the Korean dental association
    • /
    • v.41 no.1 s.404
    • /
    • pp.35-41
    • /
    • 2003
  • Wettability of addition silicone impression material is very important property for making an accurate restoration. This study examined theimpression quality in clinical condition and the wettability of impression material. Three commercially available addition silicone impression material (Imprint; 3M, USA, Examix; GC, Japan, Perfect; Handae, Korea) were studied. A total of 90 putty/wash impressions of semi-dried premolars and wet molar teeth were examined for void production in impression body. The percentae of the sulcus reproduction ability of each material was calculated from the sulcus depths of cross-sectioned casts from the impressions with stereomicroscope. Three impression materials were used to produce die stone casts from vcid entrapment die. Voids in the stone casts were counted with the stereomicroscpe. From the experiment, the following results were obtained: 1. In direct observation, Imprint showed greatest numbers of void in impression body (P<.001).However, correlations were not found between sulcus reproduction and void production. 2. Sulcus reproduction ability of additional silicone impression material was diminished in order of Imprint, Examix, Perfect. The significant difference was found between Imprint and other material (P<.001). 3. In void entrapment laboratory test, void productions was diminished in order of Examix, Imprint, Perfect. All voids in casts were less in delayed poured cast than immediately poured cast. 4. Especially, the stone pouring time of Perfect impression material should be delayed.

  • PDF